Preview only show first 10 pages with watermark. For full document please download

Návod Na Obsluhu (en) Kern Ikt Fkt Pkt Univerzálna Váha S

   EMBED


Share

Transcript

KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: [email protected] Phone: +49-[0]7433- 9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Touch screen-Industrial Balance Váha s dotykovým displejom KERN FKT / IKT / PKT Version 3.4 01/2014 GB FKT_IKT_PKT-BA-e-1434 GB KERN FKT / IKT / PKT Version 3.4 01/2014 Operating instructions Touch screen-Industrial Balance Table of Contents 1 2 Technical Data...........................................................................................................4 Basic Information (General) ...................................................................................17 2.1 2.2 2.3 2.4 Proper use............................................................................................................................................ 17 Improper Use ....................................................................................................................................... 17 Warranty ............................................................................................................................................... 17 Monitoring of Test Resources ........................................................................................................... 17 3 Basic Safety Precautions .......................................................................................18 3.1 3.2 Pay attention to the instructions in the Operation Manual ............................................................. 18 Personnel training ............................................................................................................................... 18 4 Transportation & Storage .......................................................................................18 4.1 4.2 Testing upon acceptance ................................................................................................................... 18 Packaging / return transport .............................................................................................................. 18 5 Unpacking, Setup and Commissioning.................................................................19 5.1 5.2 5.2.1 5.3 5.4 5.5 5.6 5.7 5.8 Installation Site, Location of Use....................................................................................................... 19 Unpacking ............................................................................................................................................ 19 Placing................................................................................................................................................... 19 Mains connection ................................................................................................................................ 19 Connection of peripheral devices...................................................................................................... 19 Initial Commissioning ......................................................................................................................... 19 Adjustment........................................................................................................................................... 20 Adjustment........................................................................................................................................... 20 Verification ........................................................................................................................................... 20 6 Operation .................................................................................................................21 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.9 6.10 6.11 6.12 How to turn on/off balance ................................................................................................................. 21 Screen Operating mode Weighing..................................................................................................... 24 Screen operating mode Counting...................................................................................................... 25 Screen Operating mode Totalizing .................................................................................................... 27 Screen Operating mode Dispensing ................................................................................................. 29 Screen Operating mode Check weighing ......................................................................................... 31 Screen Operating mode Percentage ................................................................................................. 33 Screen Operating mode Animal weighing ........................................................................................ 35 Screen Operating mode Formulation ................................................................................................ 37 Screen Operating mode Surface weight ........................................................................................... 39 Screen Operating mode Density........................................................................................................ 41 Forms.................................................................................................................................................... 43 7 Print form .................................................................................................................44 7.1 7.2 Contents of the form impression....................................................................................................... 44 Arrangement of form printout ............................................................................................................ 45 FKT_IKT_PKT-BA-e-1434 2 8 Interfaces ................................................................................................................. 46 8.1 8.2 8.3 8.3.1 8.3.2 8.4 8.5 Digital I/O output - open collectors (only model FKT/IKT) .............................................................. 46 Data output RS 232 C .......................................................................................................................... 47 Interface RS 232C ................................................................................................................................ 47 There are 4 kinds of data output via RS 232C....................................................................................... 48 Explanation of the data transfer............................................................................................................. 48 Printer ................................................................................................................................................... 49 Underfloor weighing............................................................................................................................ 49 9 Service, maintenance, disposal............................................................................. 50 9.1 9.2 9.3 Cleaning................................................................................................................................................ 50 Service, maintenance .......................................................................................................................... 50 Disposal................................................................................................................................................ 50 10 11 Instant help.............................................................................................................. 51 Declaration of conformity....................................................................................... 52 3 FKT_IKT_PKT-BA-e-1434 1 Technical Data Models FKT: KERN FKT 6K0.02 FKT 6K0.05 FKT 6K0.1 FKT 12K0.05 Readability (d) 0.02 g 0.05 g 0.1 g 0.05 g Weighing range (max) 6 000 g 6 000 g 6 000 g 12 000 g Taring range (subtractive) 6 000 g 6 000 g 6 000 g 12 000 g Reproducibility 0.04 g 0.05 g 0.2 g 0.05 g Linearity ±0.1 g ±0.15 g ±0.2 g ±0.15 g Smallest piece weight 0.02 g 0.05 g 0.1 g 0.05 g 2/5/6 kg 2/5/6 kg 2/5/6 kg 2/5/10/12 kg 5 kg 5 kg 5 kg 10 kg Adjustment points Recommended adjusting weight F1 (not supplied) Humidity of air max. 80% rel. (non-condensing) Stabilization time (typical) 3 sec. Allowable ambient temperature +10 °C … + 40 °C Warm-up time Housing (B x D x H) mm Vibration filter 4h 2h 2h 270 x 345 x 106 yes Weighing plate stainless steel mm 253 x 228 Units see menu Weight kg (net) Data interface Master data storage for all operating modes Print forms with up to 20 informations Recipes with up to 10 components FKT_IKT_PKT-BA-e-1434 2h 3.3 yes (RS232) 80 16 99 4 KERN FKT 12K0.1 FKT 12K0.2 FKT 24K0.1 FKT 24K0.2 0.1 g 0.2 g 0.1 g 0.2 g Weighing range (max) 12 000 g 12 000 g 24 000 g 24 000 g Taring range (subtractive) 12 000 g 12 000 g 24 000 g 24 000 g Reproducibility 0.1 g 0,2 g 0.1 g 0.2 g Linearity ±0.3 g ±0.4 g ±0.3 g ±0.6 g Smallest piece weight 0.1 g 0.2 g 0.1 g 0.2 g 2/5/10/12 kg 2/5/10/12 kg 5/10/15/20/24 kg 5/10/15/20/24 kg 10 kg 10 kg 20 kg 20 kg Readability (d) Adjustment points Recommended adjusting weight F1 (not supplied) Humidity of air max. 80% rel. (non-condensing) Stabilization time (typical) 3 sec. Allowable ambient temperature +10 °C … + 40 °C Warm-up time Housing (B x D x H) mm Vibration filter 4h 2h 2h 270 x 345 x 106 yes Weighing plate stainless steel mm 253 x 228 Units see menu Weight kg (net) Data interface Master data storage for all operating modes Print forms with up to 20 informations Recipes with up to 10 components 5 2h 3.3 yes (RS232) 80 16 99 FKT_IKT_PKT-BA-e-1434 FKT 6K0.02L FKT 16K0.05L FKT 16K0.1L FKT 30K0.5L FKT 36K0.1L Readability (d) 0.02 g 0.05 g 0.1 g 0,5 g 0.1 g Weighing range (max) 6 000 g 16 000 g 16 000 g 30.000 g 36 000 g Taring range (subtractive) 6 000 g 16 000 g 16 000 g 30.000 g 36 000 g Reproducibility 0.04 g 0.1 g 0.1 g 0,5 g 0.2 g Linearity ±0.1 g ±0.25 g ±0.3 g ±1,0 g ±0.5 g Smallest piece weight 0.02 g 0.05 g 0.1 g 0,5 g 0.1 g 2/4/5/6 kg 5/10/15/16 kg 5/10/15/16 kg 10/20/30 kg 10/20/30/36 kg 10 kg + 5 kg 10 kg + 5 kg 20 kg+10 kg 20 kg + 10 kg KERN Adjustment points Recommended adjusting weight F1 (not supplied) 5 kg Humidity of air max. 80% rel. (non-condensing) Stabilization time (typical) 3 sec. Permitted environmental temperature Warm-up time Housing (B x D x H) mm Vibration filter +10 °C … + 40 °C 4h 4h 2h yes 340 x 240 Units see menu Data interface Master data storage for all operating modes Print forms with up to 20 informations Recipes with up to 10 components Battery operation with 6 x 1,5 V, Size C FKT_IKT_PKT-BA-e-1434 4h 350 x 390 x 120 Weighing plate stainless steel mm Weight kg (net) 2h 6.5 yes (RS232) 80 16 99 yes 6 KERN FKT 36K0.2L FKT 60K1L FKT 65K0.2L FKT 65K0.5L 0.2 g 1g 0.2 g 0.5 g Weighing range (max) 36 000 g 60 000 g 65 000 g 65 000 g Taring range (subtractive) 36 000 g 60 000 g 65 000 g 65 000 g Reproducibility 0.2 g 1g 0.4 g 0.5 g Linearity ±0.6 g ±2 g ± 1.0 g ± 1.5 g Smallest piece weight 0.2 g 1g 0.2 g 0.5 g Adjustment points 10/20/30/36 kg 20/50/60 kg 20/30/50/60 kg 20/30/50/60 kg Recommended adjusting weight F1 (not supplied) 20 kg + 10 kg 50 kg 50 kg 50 kg Readability (d) Humidity of air max. 80% rel. (non-condensing) Stabilization time (typical) 3 sec. Allowable ambient temperature +10 °C … + 40 °C Warm-up time Housing (B x D x H) mm Vibration filter 2h 2h 4h 350 x 390 x 120 yes Weighing plate stainless steel mm 340 x 240 Units see menu Weight kg (net) Data interface Master data storage for all operating modes Print forms with up to 20 informations Recipes with up to 10 components Battery operation with 6 x 1,5 V, Size C 7 2h 6,5 yes (RS232) 80 16 99 yes FKT_IKT_PKT-BA-e-1434 KERN FKT 6K1LM FKT 12K2LM FKT 30K5LM FKT 60K10LM Accuracy class III III III III Readability (d) 1g 2g 5g 10 g Verification value (e) 1g 2g 5g 10 g 6 000 g 12 000 g 30 000 g 60 000 g 20 g 40 g 100 g 200 g 6 000 g 12 000 g 30 000 g 60 000 g Reproducibility 0.5 g 1g 2.5 g 5g Linearity ±0.5 g ±1 g ± 2.5 g ±5g 1g 2g 5g 10 g 2/5/6 kg 2/5/10/12 kg 10/20/30 kg 20/50/60 kg 5 kg 10 kg 20 + 10 kg 50 kg Weighing range (max) Minimum load (Min) Taring range (subtractive) Smallest piece weight Adjustment points Recommended adjusting weight M1 (not supplied) Humidity of air max. 80% rel. (non-condensing) Stabilization time (typical) 3 sec. Allowable ambient temperature +10 °C … + 40 °C Warm-up time Housing (B x D x H) mm 2h 2h 270 x 345 x 106 Vibration filter Weighing plate stainless steel mm Data interface Master data storage for all operating modes Print forms with up to 20 informations Recipes with up to 7components Battery operation with 6 x 1,5 V, Size C FKT_IKT_PKT-BA-e-1434 2h 350 x 390 x 120 yes 253 x 228 Units Weight kg (net) 2h 340 x 240 see menu 3.3 6.5 yes (RS232) 40 1 5 yes 8 Models IKT: KERN IKT 3K0.01S IKT 10K0.1S IKT 6K0.1 IKT 8K0.05 Readability (d) 0.01 g 0.1 g 0.1 g 0.05 g Weighing range (max) 3 000 g 10 000 g 6 000 g 8 000 g Taring range (subtractive) 3 000 g 10 000 g 6 000 g 8 000 g Reproducibility 0.02 g 0.1 g 0.1 g 0.05 g Linearity ±0.05 g ±0.3 g ±0.3 g ±0.15 g Smallest piece weight 0.01 g 0.1 g 0.1 g 0.05 g 1/2/3 kg 2/5/10 kg 2/5/10 kg 2/4/5/7/8 kg 3 kg 10 kg 6 kg 5 kg + 2 kg Adjustment points Recommended adjusting weight F1 (not supplied) Humidity of air max. 80% rel. (non-condensing) Stabilization time (typical) 3 sec. Allowable ambient temperature +10 °C … + 40 °C Warm-up time Housing (B x D x H) mm 4h 2h 228 x 228 x 70 Vibration filter Weighing plate stainless steel mm Data interface Master data storage for all operating modes Print forms with up to 20 informations Recipes with up to 10 components 9 2h 315 x 305 x 70 yes 228 x 228 Units Weight kg (net) 2h 315 x 305 see menu 5.5 7.5 yes (RS232) 80 16 99 FKT_IKT_PKT-BA-e-1434 KERN IKT 12K0.2 IKT 16K0.1 IKT 30K0.1 IKT 30K0.5 IKT 36K0.2 Readability (d) 0.2 g 0.1 g 0.1 g 0.5 g 0.2 g Weighing range (max) 12 000 g 16 000 g 30 000 g 30 000 g 36 000 g Taring range (subtractive) 12 000 g 16 000 g 30 000 g 30 000 g 36 000 g Reproducibility 0.2 g 0.1 g 0.2 g 0.5 g 0.2 g Linearity ±0.6 g ±0.3 g ±0.5 g ±1.0 g ±0.6 g Smallest piece weight 0.2 g 0.1 g 0.1 g 0.5 g 0.2 g 5/10/12 kg 5/10/15/16 kg Adjustment points Recommended adjusting weight F1 (not supplied) 10 kg Humidity of air 10/15/20/30 10/15/20/30 10/15/20/30/ kg kg 36 kg 10 kg + 5 kg 20kg + 10kg 20kg + 10kg 20kg + 10kg max. 80% rel. (non-condensing) Stabilization time (typical) 3 sec. Allowable ambient temperature +10 °C … + 40 °C Warm-up time Housing (B x D x H) mm Vibration filter 2h 2h 4h yes 315 x 305 Units see menu Data interface Master data storage for all operating modes Print forms with up to 20 informations Recipes with up to 10 components FKT_IKT_PKT-BA-e-1434 2h 315 x 305 x 70 Weighing plate stainless steel mm Weight kg (net) 2h 7,5 yes (RS232) 80 16 99 10 KERN IKT 30K0.1L IKT 36K0.2L IKT 60K0.2L IKT 60K1L 0.1 g 0.2 g 0.2 g 1g Weighing range (max) 30 000 g 36 000 g 60 000 g 60 000 g Taring range (subtractive) 30 000 g 36 000 g 60 000 g 60 000 g Reproducibility 0.2 g 0.2 g 0.4 g 1g Linearity ±0.5 g ±0.6 g ±1.0 g ±2.0 g Smallest piece weight 0.1 g 0.2 g 0.2 g 1g Adjustment points 10/15/20/30 kg 10/15/20/30/36 kg 20/30/50/60 kg 20/30/50/60 kg Recommended adjusting weight F1 (not supplied) 20 kg + 10 kg 20 kg + 10 kg 50 kg 50 kg Readability (d) Humidity of air max. 80% rel. (non-condensing) Stabilization time (typical) 3 sec. Allowable ambient temperature +10 °C … + 40 °C Warm-up time Housing (B x D x H) mm Vibration filter 4h 2h 4h 450 x 350 x 115 yes Weighing plate stainless steel mm 450 x 350 Units see menu Weight kg (net) Data interface 9.5 yes (RS232) Master data storage for all operating modes 80 Print forms with up to 20 informations 16 Recipes with up to 10 components 99 11 2h FKT_IKT_PKT-BA-e-1434 KERN IKT 65K0.5L IKT 100K0.5L IKT 120K2L IKT 150K1L 0.5 g 0.5 g 2g 1g Weighing range (max) 65 000 g 100 000 g 120 000 g 150 000 g Taring range (subtractive) 65 000 g 100 000 g 120 000 g 150 000 g Reproducibility 0.5 g 0.5 g 2g 1g Linearity ±1,5 g ±1,5 g ±4 g ±3 g Smallest piece weight 0.5 g 0.5 g 2g 1g 20/30/50/60 kg 20/50/100 kg 20/30/50/60 kg 50/100/150 kg 50 kg 50 kg + 50 kg 50 kg 3 x 50 kg Readability (d) Adjustment points Recommended adjusting weight F1 (not supplied) Humidity of air max. 80% rel. (non-condensing) Stabilization time (typical) 3 sec. Allowable ambient temperature +10 °C … + 40 °C Warm-up time Housing (B x D x H) mm Vibration filter 2h 2h 2h 450 x 350 x 115 yes Weighing plate stainless steel mm 450 x 350 Units see menu Weight kg (net) Data interface 9.5 yes (RS232) Master data storage for all operating modes 80 Print forms with up to 20 informations 16 Recipes with up to 10 components 99 FKT_IKT_PKT-BA-e-1434 2h 12 KERN IKT 150K2XL IKT 300K5XL 2g 5g Weighing range (max) 150 000 g 300 000 g Taring range (subtractive) 150 000 g 300 000 g Reproducibility 2g 5g Linearity ±4 g ±10 g Smallest piece weight 2g 10 g 20/50/100 kg 20/30/50/60 kg 3 x 50 kg 3 x 100 kg Readability (d) Adjustment points Recommended adjusting weight F1 (not supplied) Humidity of air max. 80% rel. (non-condensing) Stabilization time (typical) 3 sec. Allowable ambient temperature +10 °C … + 40 °C Warm-up time Housing (B x D x H) mm Vibration filter 2h 2h 650 x 500 x 142 yes Weighing plate stainless steel mm 650 x 500 Units see menu Weight kg (net) Data interface Master data storage for all operating modes Print forms with up to 20 informations Recipes with up to 10 components 13 20 yes (RS232) 80 16 99 FKT_IKT_PKT-BA-e-1434 KERN IKT 6K1M IKT 12K2M IKT 30K5M IKT 60K10LM IKT 120K20LM Accuracy class III III III III III Readability (d) 1g 2g 5g 10 g 20 g Verification value (e) 1g 2g 5g 10 g 20 g 6 000 g 12 000 g 30 000 g 60 000 g 120 000 g 20 g 40 g 100 g 200 g 400 g 6 000 g 12 000 g 30 000 g 60 000 g 120 000 g Reproducibility 0.5 g 1g 2.5 g 5g 10 g Linearity ±0.5 g ±1 g ± 2.5 g ±5g ± 10 g 1g 2g 5g 10 g 20 g 20/50/60 kg 20/50/100/ 120 kg 50 kg 50kg+50kg Weighing range (max) Minimum load (Min) Taring range (subtractive) Smallest piece weight Adjustment points Recommended adjusting weight M1 (not supplied) 2/5/6 kg 10 kg Humidity of air 2/5/10/12 kg 10/20/30 kg 10 kg 20 + 10 kg max. 80% rel. (non-condensing) Stabilization time (typical) 3 sec. Allowable ambient temperature +10 °C … + 40 °C Warm-up time Housing (B x D x H) mm 2h 2h 315 x 305 x 70 Vibration filter Weighing plate stainless steel mm Data interface Master data storage for all operating modes Print forms with up to 20 informations Recipes with up to 7 components FKT_IKT_PKT-BA-e-1434 2h 2h 450 x 350 x 115 yes 315 x 305 Units Weight kg (net) 2h 450 x 350 see menu 7.5 9.5 yes (RS232) 40 1 5 14 Models PKT: KERN PKT 300-3 PKT 420-3 PKT 3000-2 PKT4200-2 0.001 g 0.001 g 0.01 g 0.01 g Weighing range (max) 300 g 420 g 3 000 g 4 200 g Taring range (subtractive) 300 g 420 g 3 000 g 4 200 g Reproducibility 0.002 g 0.002 g 0.02 g 0.02 g Linearity ±0.005 g ±0.005 g ±0.05 g ±0.05 g Smallest piece weight 0.001 g 0.001 g 0.01 g 0.01 g 50/100/200/300 g 100/200/300/ 400 g 1.0/1.5/2.0/3.0 g 1.0/2.0/3.0/4.0 g 200 g + 100 g 200 g + 200 g 2 kg + 1 kg 2 kg + 2 kg Readability (d) Adjustment points Recommended adjusting weight F1 (not supplied) Humidity of air max. 80% rel. (non-condensing) Stabilization time (typical) 3 sec. Allowable ambient temperature +10 °C … + 40 °C Warm-up time 4h 4h Housing (B x D x H) mm Units Weight kg (net) Data interface Master data storage for all operating modes Print forms with up to 20 informations Recipes with up to 10 components 15 4h 180 x 310 x 90 Vibration filter Weighing plate stainless steel mm 4h yes Ø 106 Ø 150 see menu 2.3 yes (RS232) 80 16 99 FKT_IKT_PKT-BA-e-1434 KERN PKT 12K0.05 PKT 16K0.1 PKT 24K0.1 0.05 g 0.1 g 0.1 g Weighing range (max) 12 000 g 16 000 g 24 000 g Taring range (subtractive) 12 000 g 16 000 g 24 000 g Reproducibility 0.05 g 0.1 g 0.1 g Linearity ±0.15 g ±0.3 g ±0.3 g Smallest piece weight 0.05 g 0.1 g 0.1 g 2/5/10/12 kg 5/10/15/16 kg 5/10/15/20/24 kg 10 kg 10 kg + 5 kg 20 kg Readability (d) Adjustment points Recommended adjusting weight F1 (not supplied) Humidity of air max. 80% rel. (non-condensing) Stabilization time (typical) 3 sec. Allowable ambient temperature +10 °C … + 40 °C Warm-up time Housing (B x D x H) mm Vibration filter 2h 2h 180 x 310 x 90 yes Weighing plate stainless steel mm 160 x 200 Units see menu Weight kg (net) Data interface Master data storage for all operating modes Print forms with up to 20 informations Recipes with up to 10 components FKT_IKT_PKT-BA-e-1434 2h 2.7 yes (RS232) 80 16 99 16 2 Basic Information (General) It is absolutely necessary that you read and understand the operating instructions prior to installation and commissioning and follow the instructions during the process! 2.1 Proper use The balance you purchased is intended to determine the weighing value of material to be weighed. It is intended to be used as a “non-automatic“ balance, i.e. the material to be weighed is manually and carefully placed in the centre of the weighing plate. As soon as a stable weighing value is reached the weighing value can be read. 2.2 Improper Use Do not use balance for dynamic weighing. In the event that small quantities are removed or added to the material to be weighed, incorrect weighing results can be displayed due to the “stability compensation“ in the balance (Example: Slowly draining fluids from a container on the balance.). Do not leave permanent load on the weighing plate. This may damage the measuring system. Impacts and overloading exceeding the stated maximum load (max) of the balance, minus a possibly existing tare load, must be strictly avoided. Balance may be damage by this. Never operate balance in explosive environment. The serial version is not explosion protected. The structure of the balance may not be modified. This may lead to incorrect weighing results, safety-related faults and destruction of the balance. The balance may only be used according to the described conditions. Other areas of use must be released by KERN in writing. 2.3 Warranty Warranty claims shall be voided in case - Our conditions in the operation manual are ignored - The appliance is used outside the described uses - The appliance is modified or opened - mechanical damage and damage caused by media, liquids - natural wear and tear - The appliance is improperly set up or incorrectly electrically connected - The measuring system is overloaded 2.4 Monitoring of Test Resources In the framework of quality assurance the measuring-related properties of the balance and, if applicable, the testing weight, must be checked regularly. The responsible user must define a suitable interval as well as type and scope of this test. Information is available on KERN’s home page (www.kern-sohn.com) with regard to the monitoring of balance test substances and the test weights required for this. Our accredited DKD calibration laboratory offers fast and inexpensive adjustment for test weights and weighing balances (reset to national normal weight). 17 FKT_IKT_PKT-BA-e-1434 3 Basic Safety Precautions 3.1 Pay attention to the instructions in the Operation Manual Carefully read this operation manual before setup and commissioning, even if you are already familiar with KERN balances. Versions in other languages are non-binding translations. The only binding version is the original document in German. 3.2 Personnel training The appliance may only be operated and maintained by trained personnel. 4 Transportation & Storage 4.1 Testing upon acceptance When receiving the appliance, please check packaging immediately, and the appliance itself when unpacking for possible visible damage. In case of visible damage have the damage verified by the messenger’s signature. Do not alter goods or packaging and do not remove any parts of the delivery. Report the damage immediately (within 24 hours) in writing to the parcel service. 4.2 Packaging / return transport  Keep all parts of the original packaging for a possibly required return.  Only use original packaging for returning.  Prior to dispatch disconnect all cables and remove loose/mobile parts.  Reattach possibly supplied transport securing devices.  Secure all parts such as the glass wind screen, the weighing platform, power unit etc. against shifting and damage. FKT_IKT_PKT-BA-e-1434 18 5 Unpacking, Setup and Commissioning 5.1 Installation Site, Location of Use The balances are designed in a way that reliable weighing results are achieved in common conditions of use. You will work accurately and fast, if you select the right location for your balance. Therefore, observe the following for the installation site: Place the balance on a firm, level surface; Avoid extreme heat as well as temperature fluctuation caused by installing next to a radiator or in the direct sunlight; Protect the balance against direct draughts due to open windows and doors; Avoid jarring during weighing; Protect the balance against high humidity, vapors and dust; Do not expose the device to extreme dampness for longer periods of time. Nonpermitted condensation (condensation of air humidity on the appliance) may occur if a cold appliance is taken to a considerably warmer environment. In this case, acclimatize the disconnected appliance for ca. 2 hours at room temperature. Avoid static charging of the material to be weighed, weighing container and windshield. If electro-magnetic fields or static charge occur, or if the power supply is unstable major deviations on the display (incorrect weighing results) are possible. In that case, the location must be changed. 5.2 Unpacking Carefully remove the balance from the packaging, remove plastic cover and setup balance at the intended workstation. 5.2.1 Placing Level balance with foot screws until the air bubble of the water balance is in the prescribed circle. 5.3 Mains connection Power is supplied via the external mains adapter. The stated voltage value must be the same as the local voltage. Only use original KERN mains adapters. Using other makes requires consent by KERN. 5.4 Connection of peripheral devices Before connecting or disconnecting of additional devices (printer, PC) to the data interface, always disconnect the balance from the power supply. With your balance, only use accessories and peripheral devices by KERN, as they are ideally tuned to your balance. 5.5 Initial Commissioning A warming up time of 2 hours after switching on stabilizes the measuring values. The accuracy of the balance depends on the local acceleration of gravity. Strictly observe hints in chapter “Adjustment”. 19 FKT_IKT_PKT-BA-e-1434 5.6 Adjustment As the acceleration value due to gravity is not the same at every location on earth, each balance must be coordinated - in compliance with the underlying physical weighing principle - to the existing acceleration due to gravity at its place of location (only if the balance has not already been adjusted to the location in the factory). This adjustment process must be carried out during the initial start-up, after change in location and variation of surrounding temperature. To receive accurate measuring values it is also recommended to adjust the balance periodically in weighing operation. 5.7 Adjustment With an adjustment weight, the weighing accuracy can be checked and re-adjusted at any time. Attention: In the verified balances the adjustment is not possible. Procedure when adjusting: Observe stable environmental conditions. A short warming up time of ca. 15 minutes is recommended for stabilization. 5.8 Verification General introduction: According to EU directive 90/384/EEC balances must be verified if they are used as follows (legally controlled area): a) For commercial transactions if the price of goods is determined by weighing. b) For the production of medicines in pharmacies as well as for analyses in the medical and pharmaceutical laboratory. c) For official purposes d) For manufacturing final packages In cases of doubt, please contact your local trade in standard. Verification instructions An EU type approval exists for balances described in their technical data as verifiable. If a balance is used where obligation to verify exists as described above, it must verified and re­ verified in regular intervals. Re-verification of a balance is carried out according to the respective national regulations. The validity for verification of balances in Germany is e.g. 2 years. The legal regulation of the country where the balance is used must be observed! FKT_IKT_PKT-BA-e-1434 20 6 Operation 6.1 How to turn on/off balance To turn on touch the screen surface Turn off by touching the OFF surface command All fields with rounded corners are touch fields. 21 FKT_IKT_PKT-BA-e-1434 FKT_IKT_PKT-BA-e-1434 22 23 FKT_IKT_PKT-BA-e-1434 6.2 Screen Operating mode Weighing Display 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Designation Date Time Battery or mains operation Operation modus Tare value Range display Unity of displayed value Tare and zero set button Print button Menu button „Switch-off“ button Weighing stoppage Zeroing display Gross value Info line for operator, article, etc. FKT_IKT_PKT-BA-e-1434 24 6.3 Screen operating mode Counting Display 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 25 Designation Date Time Battery or mains operation Operation modus Net value Range display Unity of displayed value Tare and zero set button Print button Selection button REF quantity Confirmation button for REF formation Menu button (memory locations) „Switch-off“ button Weighing stoppage Zeroing display Piece weight Info line for operator, article, etc. Ref quantity FKT_IKT_PKT-BA-e-1434 FKT_IKT_PKT-BA-e-1434 26 6.4 Screen Operating mode Totalizing Display 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 27 Designation Date Time Battery or mains operation Operation modus Sum value Range display Unity of displayed value Tare and zero set button Print button Delete key Addition button Menu button (memory locations) „Switch-off“ button Weighing stoppage Zeroing display Number of positions Info line for operator, article, etc. FKT_IKT_PKT-BA-e-1434 FKT_IKT_PKT-BA-e-1434 28 6.5 Screen Operating mode Dispensing Display 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 29 Designation Date Time Battery or mains operation Operation modus Tare value Range display for target weight Unity of displayed value Tare and zero set button Print button Tolerance default Target weight input Menu button (memory locations) „Switch-off“ button Weighing stoppage Zeroing display Gross value Info line for operator, article, etc. Target weight default FKT_IKT_PKT-BA-e-1434 FKT_IKT_PKT-BA-e-1434 30 6.6 Screen Operating mode Check weighing Display 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 31 Designation Date Time Battery or mains operation Operation modus Tare value Range display Input / evaluation field plus-tolerance Tare and zero set button Print button Input / evaluation field Setpoint value default Input / evaluation field Minus-tolerance Menu button (memory locations) „Switch-off“ button Weighing stoppage Zeroing display Gross value Info line for operator, article, etc. FKT_IKT_PKT-BA-e-1434 FKT_IKT_PKT-BA-e-1434 32 6.7 Screen Operating mode Percentage Display 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 33 Designation Date Time Battery or mains operation Operation modus Net value Range display Unity of displayed value Tare and zero set button Print button Input of REF weight Confirmation of nominal weight Menu button (memory locations) „Switch-off“ button Weighing stoppage Zeroing display REF weight Info line for operator, article, etc. Difference percentage FKT_IKT_PKT-BA-e-1434 FKT_IKT_PKT-BA-e-1434 34 6.8 Screen Operating mode Animal weighing Display 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 35 Designation Date Time Battery or mains operation Operation modus Tare value Measuring period Unity of displayed value Tare and zero set button Print button / deleting the mean value Start measurement Mean value for animal weighing Menu button (memory locations) „Switch-off“ button Weighing stoppage Zeroing display Gross value Info line for operator, article, etc. Net value FKT_IKT_PKT-BA-e-1434 FKT_IKT_PKT-BA-e-1434 36 6.9 Screen Operating mode Formulation Display 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 37 Designation Date Time Battery or mains operation Operation modus Tare value Range display Unity of displayed value Tare and zero set button Print button Confirmation of component / Transfer of new target weight Selection of formula Menu button (memory locations) „Switch-off“ button Weighing stoppage Zeroing display Gross value Info line for operator, article, etc. Target weight default FKT_IKT_PKT-BA-e-1434 FKT_IKT_PKT-BA-e-1434 38 6.10 Screen Operating mode Surface weight Display 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 39 Designation Date Time Battery or mains operation Operation modus Tare value Range display Unity of displayed value Tare and zero set button Print button Input of variable factor Selection of paper format Menu button (memory locations) „Switch-off“ button Weighing stoppage Zeroing display Gross value Info line for operator, article, etc. FKT_IKT_PKT-BA-e-1434 FKT_IKT_PKT-BA-e-1434 40 6.11 Screen Operating mode Density Display 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 41 Designation Date Time Battery or mains operation Operation modus Test equipment / water temperature Net value Range display Unity of displayed value Tare and zero set button Print button for printout and delete the density value Button for reference confirmation Menu button (memory locations) „Switch-off“ button Weighing stoppage Zeroing display Gross value Info line for operator, article, etc. FKT_IKT_PKT-BA-e-1434 FKT_IKT_PKT-BA-e-1434 42 6.12 Forms 43 FKT_IKT_PKT-BA-e-1434 7 Print form 7.1 Contents of the form impression FKT_IKT_PKT-BA-e-1434 44 7.2 Arrangement of form printout x = space character • • • • The fields „line“ and „column“ are position printing input fields Field „Variable“ is a selection field of fixed printing possibilities Field „Fix text“ offers the possibility to specify texts for printout. The field „designation“ is a text input field to add information such as gross, tare, net, pcs to the values. • Field „Activated: on“ takes over this line into the print form. 45 FKT_IKT_PKT-BA-e-1434 8 Interfaces 8.1 Digital I/O output - open collectors (only model FKT/IKT) Out 1 PIN 1 Diode connecting plug 5 pol. Typ Masei 5100 S version D 2 Out 2 5 4 2 3 Out 3 1 3 Performance data: + 12V Vcemax = 35 V DC Icmax = 80 mA DC 4 5 Out 1 = Limit 1 Out 2 = Limit 2 Out 3 = Limit 3 FKT_IKT_PKT-BA-e-1434 46 8.2 Data output RS 232 C Technical data: 8-bit ASCII Code  1 start bit, 8 data bits, 1 stop bit, no parity bit  Baud rate selectable from 2400, 4800, 9600 Baud (factory setting) and 19200 Baud.  Sub-D plug 9-channel required  For operation with interface faultless operation is only ensured with the correct KERN – interface cable (max. 2m) Pin allocation of the balance output socket (front view) Sub-D jack 9-channel 5 1 9 6 Pin 2: Transmit data Pin 3: Receive data Pin 5: Signal ground 8.3 Interface RS 232C Data output via interface RS 232C General The previous condition for the data transfer between balance and a peripheral device (e.g. printer, PC ...) is that the appliances are set to the same interface parameters (e.g. baud rate, parity ...). 47 FKT_IKT_PKT-BA-e-1434 8.3.1 There are 4 kinds of data output via RS 232C Data output using the PRINT key The printing process can be triggered by pressing the PRINT key. The settings AUTOPRINT and AUTOPRINT should be disabled for this process. AUTOPRINT (data output according to weight application) The setting AUTOPRINT is located on the PRINTER path where you can turn it on or off. When AUTOPRINT is active, the current weighing value will be sent via the RS 232 date interface after unloading and subsequent loading of the balance as soon as the balance is in resting position. Permanent PRINT (continuous data output) The setting permanent Print is located on the PRINTER path and where you can turn it on or off. When permanent Print is active, the current weighing values will be sent continuously via the RS 232 data interface. Data output and remote control commands Remote control commands transferred as ASCII characters to the balance can be used to trigger the following functions on the balance (always finish with CR, LF!): t Taring w The balance sends a weighing value (also unstable) via the serial interface. s The balance sends a stable weighing value via the serial interface. After receiving either character w or s, the balance will send without a printer pause between the characters. 8.3.2 Explanation of the data transfer Each data transfer is structured as follows: Bit.Nr. 1 N 2 3 N N 4 N 5 N 6 B 7 B 8 B 9 10 11 12 13 14 15 16 17 18 19 20 B B B B B B B B 0 • 0 0 Bit.Nr. 21 22 23 24 25 26 E E E E CR LF N B*: B, 0, ., g: E CR: LF: = = = = = = Numerator Blank or for autotare on in zero range. Blank or weighing value giving unit according to loading of the balance Unit Carriage Return Line Feed FKT_IKT_PKT-BA-e-1434 48 8.4 Printer The serial interface RS 232 facilitates the connection of a printer. The printout shows the weight in grams. In counting mode either the piece number or the weight details will be printed out. In percentage mode the percentage proportion or the weight details will be printed out. Printout will take place after pressing the PRINT key. It is possible to number each printout continuously with the help of the numerator. The numerator will be reset to (000) each time the balance is turned off or the CLEAR function is actuated. 8.5 Underfloor weighing Objects which are unsuitable for placement on the weighing tray due to their size or shape can be weighed with the help of the underfloor weighing facility. Proceed as follows: • • • • • • Switch off balance. Turn over the balance and in doing so take care that the weighing plate is not loaded. Open the closing lid on the bottom of your balance. Mount the hooks for underfloor weighing. Put the balance over an opening Suspend the goods to be weighed from the hook and carry out the weighing. ▬ ▬ CAUTION ▬ Always ensure that all suspended objects are stable enough to hold the desired goods to be weighed safely (danger of breaking). Never suspend loads that exceed the stated maximum load (max) (danger of breaking) Always ensure that there are no persons, animals or objects that might be damaged underneath the load. After completing the underfloor weighing the opening on the bottom of the balance must always be closed (dust protection). 49 FKT_IKT_PKT-BA-e-1434 9 Service, maintenance, disposal 9.1 Cleaning Before cleaning, please disconnect the appliance from the operating voltage. Please do not use aggressive cleaning agents (solvents or similar agents), but a cloth dampened with mild soap suds. Ensure that no liquid penetrates into the device and wipe with a dry soft cloth. Loose residue sample/powder can be removed carefully with a brush or manual vacuum cleaner. Spilled weighing goods must be removed immediately. 9.2 Service, maintenance The appliance may only be opened by trained service technicians who are authorized by KERN. Before opening, disconnect from power supply. 9.3 Disposal Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used. FKT_IKT_PKT-BA-e-1434 50 10 Instant help In case of an error in the program process, briefly turn off the balance and disconnect from power supply. The weighing process must then be restarted from the beginning. Help: Fault Possible cause The displayed weight does not glow. • The balance is not switched on. • The mains supply connection has been interrupted (mains cable not plugged in/faulty). • Power supply interrupted. The displayed weight is permanently • Draught/air movement changing • Table/floor vibrations • Weighing plate has contact with other objects. • Electromagnetic fields / static charging (choose different location/switch off interfering device if possible) The weighing value is obviously • The display of the balance is not at zero wrong • Adjustment is no longer correct. • Great fluctuations in temperature. • Electromagnetic fields / static charging (choose different location/switch off interfering device if possible) Should other error messages occur, switch balance off and then on again. If the error message remains inform manufacturer. 51 FKT_IKT_PKT-BA-e-1434 11 Declaration of conformity KERN & Sohn GmbH D-72322 Balingen-Frommern Postfach 4052 E-Mail: [email protected] Tel: 0049-[0]7433- 9933-0 Fax: 0049-[0]7433-9933-149 Internet: www.kern-sohn.de Declaration of conformity EC-Konformitätserklärung EC- Déclaration de conformité EC-Dichiarazione di conformità EC- Declaração de conformidade EC-Deklaracja zgodności D GB CZ E F I NL P PL RUS Konformitätserklärung Declaration of conformity Prohlášení o shode Declaración de conformidad Déclaration de conformité Dichiarazione di conformitá Conformiteitverklaring Declaração de conformidade Deklaracja zgodności Заявление о соответствии EC-Declaration of -Conformity EC-Declaración de Conformidad EC-Conformiteitverklaring EC- Prohlášení o shode EC-Заявление о соответствии Wir erklären hiermit, dass das Produkt, auf das sich diese Erklärung bezieht, mit den nachstehenden Normen übereinstimmt. We hereby declare that the product to which this declaration refers conforms with the following standards. Tímto prohlašujeme, že výrobek, kterého se toto prohlášení týká, je v souladu s níže uvedenými normami. Manifestamos en la presente que el producto al que se refiere esta declaración está de acuerdo con las normas siguientes Nous déclarons avec cela responsabilité que le produit, auquel se rapporte la présente déclaration, est conforme aux normes citées ci-après. Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si riferisce è conforme alle norme di seguito citate. Wij verklaren hiermede dat het product, waarop deze verklaring betrekking heeft, met de hierna vermelde normen overeenstemt. Declaramos por meio da presente que o produto no qual se refere esta declaração, corresponde às normas seguintes. Niniejszym oświadczamy, że produkt, którego niniejsze oświadczenie dotyczy, jest zgodny z poniższymi normami. Мы заявляем, что продукт, к которому относится данная декларация, соответствует перечисленным ниже нормам. Electronic Balance: KERN FKT / IKT / PKT EU Directive 2004/108/EC 2006/95/EC Datum Standards EN 55011: 2009/A1:2010 EN 55022: 2010/AC:2011 EN 61000-3-2 :2006-04 + A1 : 2009 + A2 : 2009 EN61000-3-3 :2008 EN 55024: 2010 EN45501 :1992-10+AC :1993-08 OIML R 76-1 :2006 EN60950 08.04.2013 Signatur Date Signature Ort der Ausstellung 72336 Balingen Place of issue Albert Sauter KERN & Sohn GmbH Geschäftsführer Managing director KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-[0]7433/9933-0 Fax +49-[0]7433/9933-149, E-Mail: [email protected], Internet: www.kern-sohn.com FKT_IKT_PKT-BA-e-1434 52