Transcript
2015-11-23
Narrow beam LED in Mini MIDLED package (940 nm) Version 1.3
SFH 4441
Features: • Highly Efficient Infrared LED • Short switching times • Narrow halfangle (+-17°) • Low profile component Applications Sensor technology • • For control and drive circuits • Proximity sensor • Mobile devices Notes Depending on the mode of operation, these devices emit highly concentrated non visible infrared light which can be hazardous to the human eye. Products which incorporate these devices have to follow the safety precautions given in IEC 60825-1 and IEC 62471.
Ordering Information Type:
Radiant Intensity
Ordering Code
Ie [mW/sr] IF = 100 mA, tp= 20 ms SFH 4441 Note:
65 (≥ 25)
Q65111A4266
Measured at a solid angle of Ω = 0.01 sr
2015-11-23
1
Version 1.3
SFH 4441
Maximum Ratings (TA = 25 °C) Parameter
Symbol
Values
Operation and storage temperature range
Top; Tstg
-40 ... 85
°C
Reverse voltage
VR
5
V
Forward current
IF
100
Surge current (tp = 300 µs, D = 0)
IFSM
1
Power consumption
Ptot
180
ESD withstand voltage (acc. to ANSI/ ESDA/ JEDEC JS-001 - HBM)
VESD
2
Thermal resistance junction - ambient 1) page 13
RthJA
400
K/W
Thermal resistance junction - soldering point
RthJS
200
K/W
2) page 13
Unit
mA A mW kV
Characteristics (TA = 25 °C) Parameter
Symbol
Values
Unit
Peak wavelength (IF = 100 mA, tp = 20 ms)
(typ)
λpeak
950
nm
Centroid wavelength (IF = 100 mA, tp = 20 ms)
(typ)
λcentroid
940
nm
Spectral bandwidth at 50% of Imax (IF = 100 mA, tp = 20 ms)
(typ)
∆λ
42
nm
Half angle
(typ)
ϕ
± 17
Dimensions of active chip area
(typ)
LxW
Rise and fall time of Ie ( 10% and 90% of Ie max) (IF = 100 mA, RL = 50 Ω)
(typ)
tr, tf
Forward voltage (IF = 100 mA, tp = 20 ms) Forward voltage (IF = 1 A, tp = 100 µs)
2015-11-23
mm x mm
12
ns
(typ (max)) VF
1.5 (≤ 1.8)
V
(typ (max)) VF
2.3 (≤ 3)
V
Reverse current (VR = 5 V) Total radiant flux (IF=100 mA, tp=20 ms)
0.3 x 0.3
°
(typ)
2
IR
not designed for reverse operation
µA
Φe
50
mW
Version 1.3
SFH 4441
Parameter
Symbol
Values
Unit
Temperature coefficient of Ie or Φe (IF = 100 mA, tp = 20 ms)
(typ)
TCI
-0.5
%/K
Temperature coefficient of VF (IF = 100 mA, tp = 20 ms)
(typ)
TCV
-1.3
mV / K
Temperature coefficient of wavelength (IF = 100 mA, tp = 20 ms)
(typ)
TCλ
0.3
nm / K
Grouping (TA = 25 °C) Group
Min Radiant Intensity
Max Radiant Intensity
Typ Radiant Intensity
IF = 100 mA, tp= 20 ms
IF = 100 mA, tp= 20 ms
IF = 1 A, tp = 25 µs
Ie, min [mW / sr]
Ie, max [mW / sr]
Ie, typ [mW / sr]
SFH 4441-T
25
50
300
SFH 4441-U
40
80
480
SFH 4441-V
63
125
750
SFH 4441-AW
100
200
1200
Note:
measured at a solid angle of Ω = 0.01 sr Only one group in one packing unit (variation lower 2:1).
2015-11-23
3
Version 1.3
SFH 4441
Relative Spectral Emission 3) page 13 Irel= f (λ ), TA= 25 °C
Radiant Intensity 3) page 13 Ie / Ie(100 mA) = f(IF), single pulse, tp = 25 µs, TA= 25°C
OHF04134
100
OHF03821
101
I rel %
Ie I e (100 mA)
80
100 5
60
10-1
40
5
10-2
20
5
0 800
850
900
nm 1025
950
10-3 0 10
λ
5 10 1
5 10 2
mA 10 3
IF Forward Current 3) page 13 IF = f(VF), single pulse, tp = 100 µs, TA= 25°C
Max. Permissible Forward Current IF, max = f(TA), RthJA = 400 K / W OHF05494
110 I F mA
IF
OHF03822
100 A
90
10-1
80
5
70 60
10-2
50
5
40 30
10-3
20
5
10 0
0
20
40
60
10-4
80 ˚C 100
TA
2015-11-23
0
0.5
1
1.5
2 V 2.5
VF
4
Version 1.3
SFH 4441
Permissible Pulse Handling Capability IF = f(tp), TA = 25 °C, duty cycle D = parameter
IF
Permissible Pulse Handling Capability IF= f (tp), T A= 85 °C, duty cycle D = parameter
OHF05492
1.1 A
t
tP
IF
IF
D = TP
T
0.9
OHF05493
1.1 A
t
tP IF
D = TP
T
0.9
0.8
0.8
0.7
0.7
D= 0.005 0.01 0.02 0.05 0.1 0.2 0.5 1
0.6 0.5 0.4 0.3 0.2
0.6
D= 0.005 0.01 0.02 0.05 0.1 0.2 0.5 1
0.5 0.4 0.3 0.2
0.1
0.1
0 -5 10 10-4 10-3 10-2 10-1 100 101 s 102
0 -5 10 10-4 10-3 10-2 10-1 100 101 s 102
tp
tp
Radiation Characteristics 3) page 13 Irel = f(ϕ), TA= 25°C 40˚ 30˚ 20˚
10˚
ϕ
0˚
OHF05558
1.0
50˚ 0.8 60˚
0.6
70˚
0.4
80˚
0.2 0
90˚
100˚
2015-11-23
1.0
0.8
0.6
0.4
0˚
5
20˚
40˚
60˚
80˚
100˚
120˚
Version 1.3
SFH 4441
Package Outline
Dimensions in mm. Package Mini MIDLED, Silicone, colourless, clear Approximate Weight: 10 mg
2015-11-23
6
Version 1.3
SFH 4441
Recommended Solder Pad
Dimensions in mm (inch). Handling indication The package is casted with silicone. Mechanical stress at the surface of the unit should be as low as possible.
2015-11-23
7
Version 1.3
SFH 4441
Reflow Soldering Profile Product complies to MSL Level 2 acc. to JEDEC J-STD-020D.01 OHA04525
300 ˚C
T 250
Tp 245 ˚C
240 ˚C
tP
217 ˚C 200
tL
150
tS
100
50 25 ˚C 0
50
0
100
150
200
250
s 300
t OHA04612
Profile Feature Profil-Charakteristik
Symbol Symbol
Pb-Free (SnAgCu) Assembly Minimum
)
Ramp-up rate to preheat* 25 °C to 150 °C Time tS TSmin to TSmax
tS
60
Ramp-up rate to peak*) TSmax to TP
Recommendation
Maximum
2
3
100
120
2
3
Unit Einheit K/s s K/s
Liquidus temperature
TL
217
Time above liquidus temperature
tL
80
100
s
Peak temperature
TP
245
260
°C
Time within 5 °C of the specified peak temperature TP - 5 K
tP
20
30
s
3
6
K/s
10
Ramp-down rate* TP to 100 °C
480
Time 25 °C to TP All temperatures refer to the center of the package, measured on the top of the component * slope calculation DT/Dt: Dt max. 5 s; fulfillment for the whole T-range
2015-11-23
°C
8
s
Version 1.3
SFH 4441
Taping
Dimensions in mm (inch).
Tape and Reel 8 mm tape with 3000 pcs. on ∅ 180 mm reel W1 D0
P0
A N
F W
E
13.0 ±0.25
P2
Label
P1 Direction of unreeling
Direction of unreeling
W2
Leader: min. 400 mm * Trailer: min. 160 mm * *) Dimensions acc. to IEC 60286-3; EIA 481-D OHAY0324
2015-11-23
9
Version 1.3
SFH 4441
Tape dimensions [mm] Tape dim ensions in m m
W
P0
P1
P2
D0
E
F
8 + 0.3 / -0.1
4 ± 0.1
2 ± 0.05 or 4 ± 0.1
2 ± 0.05
1.5 ± 0.1
1.75 ± 0.1
3.5 ± 0.05
Reel dimensions [mm] Reel dim ensions in m m
A
W
Nmin
W1
W2max
180
8
60
8.4 + 2
14.4
Barcode-Product-Label (BPL) OSRAM Opto
EX A
RoHS Compliant
(6P) BATCH NO: 1234567890
(1T) LOT NO: 1234567890
BIN1: XX-XX-X-XXX-X
LX XXXX
Semiconductors
MP
ML Temp ST X XXX °C X
(9D) D/C: 1234
Pack: RXX
LE
DEMY
XXX
X_X123_1234.1234 X
(X) PROD NO: 123456789(Q)QTY:
9999
(G) GROUP:
XX-XX-X-X
OHA04563
Dry Packing Process and Materials
Moisture-sensitive label or print L VE el
LE
.
see lab e
If
ve ati
nk, bla cod bar
y
H)
(R .
dit mi hu e ed ag
RH % /60
Barcode label
˚C
rar ck rel 30 N s VE RS inf pa % ainITI TO of to ak 90 d ntNSUC < ns (pe TIO or d , cte itio U g coSEND an bje ing ˚C nd 5 ˚C su ss CO Ais baRE co ± ce y 40 be TU MI CThIS ˚C < tor ll pro SE _ <
urs ). urs Ho de urs Ho co 72 Ho urs te 48 e Ho 24 6 da e tim e th tim or ). 23 wi nt tim e or l wi fac ˚C Flo tim at or ca at re. Flo d tha ale el or nth nti Flo uiv du if: rea es l 4 5 Flo lab mo ide ce eq low g, l ve vic is be or de 24 tin en l 5a6 pro ve Le de , e te co , g: ve l un wh Le ke r se da ure ba ed low ba Le ve mo % ba e al d ure Le ist en ref e e 10 tim ure se for ist ale op se for > , Mo se 3 ist ure is or . , is ha se Mo nk be ist nk g rd -03 Mo in n Flo r-p RH g, bla Mo ba TD po If blathi % kin Ca life s (if ar t. wi 10 ba tor J-S thi, va p. elf Ye ar ks _ < e icat me , C 1 Ye ee urs Sh terlow tem ted at ed uir > 1 W no un DE Ho Af Ind 1. d e 4 8 uir ref dy reqy is 2. JE bo e Mo ore tim 16 req : C/ e es dit2b a) St tim or mi IP ed or g is tim e vic b) or e Hu Flo en tim or De 2a kin nc te Flo a) op or 3. b) baere Flo da e l 1 2 Flo If al ref tim ve l 4. se d l 2a3 ve Le g an ve l Le Ba te ure Le ve ure Le ist Da ure ist Mo ist ure Mo ist Mo Mo
MO TO OP
s
at
t
M RA OS
Humidity indicator Barcode label Please check the HIC immidiately after bag opening. Discard if circles overrun. Avoid metal contact. Do not eat. Comparator check dot
WET
If wet, examine units, if necessary bake units
15%
If wet, examine units, if necessary bake units
10% 5%
If wet, parts still adequately dry. change desiccant Humidity Indicator MIL-I-8835
AM OSR
Desiccant
OHA00539
Note: Moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card. Regarding dry pack you will find further information in the internet. Here you will also find the normative references like JEDEC.
2015-11-23
10
Version 1.3
SFH 4441
Transportation Packing and Materials
Barcode label
D/
8
Y M DE
R 18
-1 P -1 + Q
C:
99
D/
21 00
(9 D)
21 :
20 00
:
14 2
5
(Q )Q TY
O
H 12 34
S S em R ic AM on du O p ct to or H NO s TC
3G
BA (6 P)
NO : 12
11 00
LO T (1 T)
NO :
TY : 20
(Q
)Q
: NO
M
RA
OS
(X
)
PR O
D
5 14 2 110 0
Packing Sealing label
Dimensions of transportation box in mm Width
Length
Height
200 ± 5
195 ± 5
30 ± 5
2015-11-23
OD PR ) (X
(G
)
G
RO
UP
:
P
-1
+ Q
-1
R 18
DE M
Y
Bi n2 : Pn3 : Q 1: -1 20 M -2 2 L 0 Te 2a 22 m 3 24 0 p ST Ad 26 0 C R C R0 ditio 0 C R PA 77 na RT l TE CK VA XT R:
M u L lt S iT Y O T P 67 L 6 E Bi D Bi n1
00
C:
01
44
Muster
O
ct pto o rs u
M
(9 D)
d
A
n o
:
34
ic
S R
NO
O
BA TC H
3G H
(1
T)
LO
T
NO
(6
P)
S
8 12
2199
: 12
em
2100
01 44
el
OU P:
L
GR
E
V
LE see . lab e H) nk, cod (R bla r If ty ba . idi RH m hu 0% e /6 ive d ˚C re ag lat ra ck re 30 _ < inf pa % k s of to 90 ea ur s d ). < ns (p or ur s d Ho de , cteg itio ur s Ho an bje co ˚C 72 sin nd Ho ur 5 te 48 ˚C su es e Ho co ± 24 6 da e 40 be oc ry tim ˚C e r th < ll pr tim cto ). r OI oo 23 wi nt tim e at l wi fa r M TO Fl oo tim s at at ale ˚C at e. ica Fl th oo r th ur el OP nt Fl oo on es uiv if: read ed l 4 5 Fl , lab m ide eq low l oc ve vic is en ing be or de 24 l 5a6 pr ve Le de nt wh e te co , w, g: ve l Le ke r re ou se da ba ed flo Le ve tu re m % ba e ba al d Le r en re tu re e re 10 ois tim se fo tu re ale op se fo > , M r se ois 3 is , is ha se M ois tu nk be oo . 03 nk rd g M ois in r-p bla in Fl RH g, DM ba po If blath % kin Ca life is (if . ar ST p. wi 10 baator et Jelf r th va Ye ar ks s m _ < m ed 1 Ye ee ur d, C iredic t Sh te w, te at nt > 1 W Ho Af flody qu In no ire DE 1. e 4 8 ou re ed is re qu ty 2. JE bo e M or tim 16 re C/ : e es idi 2b r a) St tim mor is IP ed r oo tim e vic b) g e r Hu Fl en oo tim De 2a kin nc te Fl oo r a) op 3. b) ba re Fl oo da e fe l 1 2 Fl If al re tim ve l 4. se d l 2a3 ve Le g an ve l Le re Ba te Le ve tu re Le tu Da ois re tu re M ois M ois tu M ois M
Nns IVEORS ai IT ntNS CT TIO DU U g EcoSE ON A ba IC UR M CThisSTSE
(G )
M u L lt S iT Y O T67 P L 6
Muster
E Bi D Bi n1 Bi n2 : Pn3 : Q- 1: 1- 20 M 20 2 L Te 2a 22 m 3 24 0 p ST Ad 26 0 C R 0 C R0 dit ion C R PA 77 al RT CK TE VA XT R:
Barcode label
11
OHA02044
Version 1.3
SFH 4441
Disclaimer Language english will prevail in case of any discrepancies or deviations between the two language wordings. Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. If printed or downloaded, please find the latest version in the Internet. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components* may only be used in life-support devices** or systems with the express written approval of OSRAM OS. *) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. **) Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health and the life of the user may be endangered.
2015-11-23
12
Version 1.3
SFH 4441
Glossary 1)
Thermal resistance: junction -ambient, mounted on PC-board (FR4), padsize 16 mm2 each
2)
Thermal resistance: junction - soldering point, of the device only, mounted on an ideal heatsink (e.g. metal block)
3)
Typical Values: Due to the special conditions of the manufacturing processes of LED, the typical data or calculated correlations of technical parameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data and calculated correlations or the typical characteristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any further notice.
2015-11-23
13
Version 1.3
SFH 4441
Published by OSRAM Opto Semiconductors GmbH Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved.
2015-11-23
14