Transcript

FAN COIL 1206-6180658 FFC Series SELECTION MANUAL GB FFC FAST S.p.A. 35044 Montagnana (PD) Italia - Via Luppia Alberi, 170 Tel. (+39) 0429 806311 Fax 0429 806340 www.fastaer.com - [email protected] DECLARATION OF CONFORMITY We declare under our own responsability that this machine complies with the provisions of the following Standards: - Machine Directive 98/37 CEE; - Low tension Direttiva bassa tensione 73/23 CEE; - Electromagnetic Compatibility Directive EMC 89/36 CEE. FFC WITH ACCESSORIES It is forbidden to use the product, complete with accessories not supplied by FAST, before they are declared in conformity with the above-mentioned Directives. Montagnana, 07/12/2006 Managing Director REMARKS Keep the manual in a dry place, to avoid deterioration, for at least 10 years, for possible future references. Read carefully and thoroughly all the information included in this manual. Pay special attention to the usage norms accompanied by the labels "DANGER" and "WARNING" since, if unobserved, may cause damage to the machine and/or to people. For anomalies not referred to in this manual, please contact immediately your local Service Centre. The unit must be installed so that the maintenance and/or reparation operations may be properly carried out. The warranty for the unit does not cover, in any case, costs due to cranes, scaffolds, elevators or other lifting devices which ought to be necessary for interventions in warranty. FAST S.p.A. declines all responsability for whatever damages due to an impropoer use of the unit, to a partial or superficial reading of the information included in this manual. SAFETY SYMBOLS Danger: Power supply Danger: Moving parts Danger!!! Fan coil - FFC 1206-6180658 FEATURES Description of the unit Main components Description of the components Selection criteria Operating limits 4 5 5 6 6 TECHNICAL DATA Nominal technical data Cooling capacity Heating capacity Heating capacity 1 row coil (BA accessory) Correction factors for air flow and cooling/heating capacities Water pressure drops Fan performances Sound levels 7 8 9 10 11 12 13 14 DIMENSIONS Dimensions 17 ACCESSORIES Accessories compatibilty chart Accessories data 19 20 ELECTRICAL CONNECTIONS Electrical connections and wiring diagrams 25 PACKING AND TRANSPORT 28 Selection manual 3 GB English SUMMARY Fan coil - FFC 1206-6180658 DESCRIZIONE DELL’UNITÀ DESCRIPTION OF THE UNIT PURPOSE SCOPO DELLA OF THE MACCHINA UNIT Il ventilconvettore The fan-coil is a terminal è un terminale unit for the pertreatment il trattamento of thedell’aria air inside di un a room, ambiente both sia in winter nella stagione (heating) invernale and in summer sia in quella estiva. (cooling). GRANDEZZE DISPONIBILI AVAILABLE SIZES I ventilconvettori della serie FFC sono disponibili in 7 grandezze (tutte con batteria a 3 ranghi): The fan-coils of the FFC series are available in 7 sizes (all with 3-rows coil): FFC 12 FFC 16 FFC FFC FFC 12 13 FFC 16 18 FFC 13 FFC FFC 14 FFC 18 20 FFC FFC 20 FFC 14 15 FFC 15 VERSIONI VERSIONS W con mobile di copertura: installazione verticale a parete e ripresa dal basso, senza comandi a bordo. W covering cabinet: vertical wall installation bottom intake, without on-board control. FV with con mobile di copertura: installazione verticale aand parete e ripresa frontale, senza comandi a bordo. FV with covering cabinet: vertical wall installation and front intake, without on-board control. FO con mobile di copertura: installazione orizzontale a soffitto e ripresa frontale, senza comandi a bordo. FO with covering horizontal ceiling installation front intake, without on-board control. senza comanC senza mobile cabinet: di copertura: installazione verticale, and a parete o a pavimento, ed orizzontale, C di a bordo. without covering cabinet: vertical wall installation and horizontal installation, without on-board control. FFC W FFC FV FFC FO Vertical or horizontal installation FFC C Selection manual 4 GB Fan coil - FFC 1206-6180658 MAIN COMPONENTS FFC F 5 7 English 2 12 2 13 1 6 9 14 8 15 10 11 4 3 STANDARD The air flow can be reversed 180° by rotating the grille. 1) COVERING CABINET Covering cabinet made from galvanized steel sheet (colour white RAL 9010) finished by a polyvinyl chloride film and provided with an ABS supply air grille (colour grey RAL 7035) with two available positions. 2) MAIN FRAME Made from thick galvanized steel sheet with internal thermo-acoustical insulation (M1 class) and preset holes for wall or ceiling installation. 3-4) FAN ASSEMBLY It is constituted by double intake centrifugal fans (forward curved blades) directly driven by a 230V1ph-50Hz electrical motor. 5) HEAT EXCHANGE COILS Three-rows coil with copper tubes and aluminium fins. A one-row heating coil is available as accessory (BA) for 4-pipes installations. Selection manual 6) HYDRAULIC CONNECTIONS The connections, placed on the left side, are of the female type. It is possible to rotate the coil, if necessary. 7) AIR RELIEF VALVE Manual air relief valve. 8) WATER DISCHARGE VALVE Water discharge valve to empty the coil. 9) CONDENSATE DRAIN PAN Condensate drain pan with thermal insulation with discharge pipes (for vertical versions). ACCESSORIES 12) CONTROL BOARD Available in different versions is to be installed on the opposite side of the hydraulic connections. The standard fan-coils are provided with the terminal board only. 13) MIN. WATER TEMPERATURE THERMOSTAT Minimum water temperature thermostat. 14) ROOM THERMOSTAT Room thermostat. 15) AUXILIARY DRAIN PAN Auxiliary condensate drain pan for vertical installations. 10) CONDENSATE DRAIN Condensate drain pipe. 11) AIR FILTER Air filter in G3 class (EN779) and M1 class. 5 GB Fan coil - FFC 1206-6180658 SELECTION CRITERIA The versions with covering cabinet are available for ver tical installation and bottom intake (W) or front intake (FV) and horizontal installation and front intake (FO). air inlet temperature; the fan is considered at its max. speed, for lower speeds refer to the correction factors. Table 4 on page 10 show the heating capacity for the auxiliary 1-row coil depending on the water flow and on the temperature difference between water inlet and air inlet; the fan is considered at its max speed, for lower speeds refer to the correction factors. The hanging versions (C), without covering cabinet and bottom intake, are suitable for both vertical and horizontal installations. Table 1 on page 7 shows the technical data for the FFC units with 3-row coil for 2-pipes installation and with auxiliary 1-row coil for 4pipes installations. The tables on pages 17 and 18 shows the dimensions of the units in the various configurations, with indicated position and dimensions of the connections. From page 19 the various accessories, with their main dimension and performance characteristics, are shown. Page 11 shows the correction factors to determine the cooling and heating capacities at the different fan speeds and in case of glycoled water. Table 2 on page 8 show the total and sensible cooling capacities for the 3-row coil depending on the water temperatures and on the dry and wet bulb air temperatures; the fan is considered at its max. speed, for lower speeds refer to the correction factors. The diagrams on page 12 show the water pressure drops for the 3-row and the 1-row coils. The diagrams on page 13 show the fan curves. Table 3 on page 9 shows the heating capacity for the 3row coil depending on the water temperatures and the The diagrams on pages 14, 15, 16 show the sound pressure and power levels of the units. OPERATING LIMITS Max. water inlet temperature 80°C, max. operating pressure 15 bar. Choose the installation room respecting the allowed max. and min. room temperature limits: 10 ÷ 50°C (10%< R.H.<90%). Water minimum average temperature: the average water temperature has to be higher than the limits shown in the table below (depending on the temperature and humidity conditions of the room) to prevent condensate from forming on the external surface of the unit. The above mentioned limits refer to a fan at the minimum speed. In case of prolonged operation with the fan stopped and cold water still Room dry bulb air temperature °C MINIMUM WATER AVERAGE TEMPERATURE Room wet bulb air temperature °C 21 3 3 3 6 - 15 17 19 21 23 circulating in the coil, condensate may appear on the external surface of the unit, thus the installation of the accessory 3-way valve is strongly recommended. 23 3 3 3 5 8 25 3 3 3 4 7 27 3 3 3 3 6 29 3 3 3 3 5 31 3 3 3 3 5 Water flow limits for 3 R coil: MOD. Minimum water flow Maximum water flow FFC 12 FFC 13 FFC 14 FFC 15 FFC 16 FFC18 FFC 20 l/h l/h 50 1.009 60 1.205 72 1.431 69 1.384 77 1.542 124 2.478 152 3.050 Water flow limits for 1 R coil (BA accessory): MOD. Minimum water flow Maximum water flow Selection manual FFC 12 FFC 13 FFC 14 FFC 15 FFC 16 FFC 18 FFC 20 l/h l/h 38 766 38 766 6 54 1.070 54 1.070 56 1.130 59 1.176 68 1.362 GB Fan coil - FFC 1206-6180658 FFC - NOMINAL TECHNICAL DATA Mod. * Heating capacity max. med. min. Water flow Water pressure drop Heating capacity 1R (BA)max Water flow 1R (BA) Water pressure drop 1R (BA) Total cooling capacity max. Sensible cooling capacity Water flow Water pressure drop max. Air flow med. min. Fans number max. Sound pressure level med. min. max. Sound power level med. min. Max. motor power Max. input current Water content 3R coil connections 1R (BA accessory) coil connections Width Dimensions vers. W-FV-FO Depth Height Width Dimensions vers. C Depth Height Net weight versions W-FV-FO Net weight version C * * * * * ** ** ** ** FFC [W] [W] [W] [l/h] [kPa] [W] [l/h] [kPa] [W] [W] [l/h] [kPa] [m3/h] 3 [m /h] 3 [m /h] n° [dB (A)] [dB (A)] [dB (A)] [dB (A)] [dB (A)] [dB (A)] [W] [A] [l] ø ø [mm] [mm] [mm] [mm] [mm] [mm] [kg] [kg] 12 3.430 3.060 2.440 296 13,4 1.740 150 7,7 1.500 1.290 258 13,1 350 291 200 1 38 34 28 55 51 45 45 0,20 0,79 1/2” 1/2” 670 220 470 450 215 450 13,5 10,7 13 4.330 3.870 3.090 373 14,9 1.790 154 8,1 2.000 1.620 344 16,3 360 299 205 1 38 34 28 55 51 45 45 0,20 1,11 1/2” 1/2” 670 220 470 450 215 450 14,0 11,2 14 5.510 4.920 3.930 475 17,2 2.930 252 11,1 2.530 2.070 435 18,5 435 361 248 1 40 35 29 57 52 46 65 0,30 1,48 1/2” 1/2” 870 220 470 650 215 450 16,4 13,5 15 6.140 5.490 4.380 528 22,7 3.010 259 11,7 3.020 2.380 520 28,2 447 371 255 1 40 35 29 57 52 46 65 0,30 1,48 1/2” 1/2” 870 220 470 650 215 450 17,2 14,3 16 7.980 7.230 5.870 687 31,0 4.140 360 20,2 3.750 3.080 645 35,0 647 550 388 2 42 36 30 59 53 47 85 0,40 2,52 1/2” 1/2” 1.070 220 470 850 215 450 22,5 19,5 18 12.160 11.030 8.950 1.046 27,8 6.190 533 41,0 5.520 4.600 950 29,4 975 829 585 2 43 38 32 60 55 49 120 0,55 2,52 1/2” 1/2” 1.270 220 470 1.050 215 450 26,0 22,9 20 17.020 15.650 13.140 1.464 35,9 8.205 705 53,7 7.530 6.430 1.296 36,1 1.431 1.245 930 2 49 44 37 66 61 56 140 0,65 2,52 1/2” 1/2” 1.470 220 470 1.250 215 450 30,0 26,8 The performances refer to the following operating conditions: – supply voltage 230 V (±10%); heating: water inlet = 70 °C ; air inlet = 20°C; water ∆t = 10°C at the maximum fan speed; for average and minimum fan speed consider the water flow as it were at the max. speed; ** cooling: water inlet = 27 °C db.-19 °C wb.; water inlet = 7°C; water ∆t = 5°C at the maximum fan speed; for average and minimum fan speed consider the water flow as it were at the max. speed; Sound pressure level in free field, at a distance of 2 m. Values calculated on sound power levels measured in riverberating room (ISO 3741 and ISO 3742 norms). * Selection manual 7 GB English TAV 1 Fan coil - FFC 1206-6180658 TAV 2 - COOLING CAPACITY 3 ROWS COIL Tu (°C) Ta b.s. (°C) Ta b.u. (°C) Water outlet temperature Dry bulb room air temperature Wet bulb room air temperature 24 Tu= 20 Tu= 16 26 28 30 32 34 36 24 22 22 20 20 18 18 16 16 14 14 26 28 30 32 34 36 Tu= 12 Tu= 8 Tu= 4 0 2 4 6 8 10 12 14 16 18 20 22 24 Ti (°C) (W) Water inlet temperature 30.000 20.000 10.000 8.000 - 6.000 5.000 4.000 The diagram shows the FFC units performances at the max. fan speed (with available static pressure = 0 Pa). For medium and min. speeds and/or availabe static pressure >0 Pa apply the correction factors for the cooling capacity shown at page 11 3.000 2.000 1.000 800 600 500 400 300 200 Sensible cooling capacity (max speed) (W) Total cooling capacity (max speed) REMARK: If the sensible cooling capacity results higher or equal to the total cooling capacity, the cooling capacity of the unit has to be determined only on the sensible cooling capacity diagram. In these particular cases there is no dehumidification. Selection manual 8 GB Fan coil - FFC 1206-6180658 TAV 3 - HEATING CAPACITY 3 ROWS COIL Ta (°C) Room air temperature 50 40 30 20 10 0 English Tu (°C) Water outlet temperature -10 Tu= 100 Tu= 80 Tu= 60 Tu= 40 Tu= 20 0 10 20 30 40 50 60 70 80 90 100 110 120 Ti (°C) Water inlet temperature (W) 50.000 40.000 30.000 20.000 + 10.000 8.000 The diagram shows the FFC units performances at the max. fan speed (with available static pressure = 0 Pa). For medium and min. speeds and/or availabe static pressure >0 Pa apply the correction factors for the heating capacity shown at page 11 6.000 5.000 4.000 3.000 2.000 1.000 800 600 500 400 300 200 Heating capacity (max. speed) Selection manual 9 GB Fan coil - FFC 1206-6180658 TAV 4 - HEATING CAPACITY 1 ROW COIL (ACCESSORY BA) Tu (°C) Ta (°C) Water outlet temperature Room air temperature 50 40 30 20 10 0 -10 Tu= 100 Tu= 80 Tu= 60 Tu= 40 Tu= 20 0 10 20 30 40 50 60 70 80 90 100 110 120 Ti (°C) Water inlet temperature (W) Modello - Model 50.000 40.000 30.000 20.000 10.000 8.000 The diagram shows the FFC units performances at the max. fan speed (with available static pressure = 0 Pa). For medium and min. speeds and/or availabe static pressure >0 Pa apply the correction factors for the heating capacity shown at page 11 6.000 5.000 4.000 3.000 2.000 1.000 800 600 500 400 300 200 Heating capacity (max. speed) Selection manual 10 GB Fan coil - FFC 1206-6180658 CORRECTION FACTORS FOR AIR FLOW AND COOLING/HEATING CAPACITIES Available static pressure Fan speed 0 Pa Max 1 Med 20 Pa 40 Pa 60 Pa 0 Pa 20 Pa / 1 0,96 FFC 12-13-14-15 Total cooling capacity Sensible cooling capacity Heating capacity Air flow 40 Pa 60 Pa 0 Pa 20 Pa 0,71 1 0,97 FFC 16-18 40 Pa 60 Pa FFC 20 0,94 0,78 0,88 0,93 0,85 0,91 0,83 0,51 / 0,92 0,88 0,77 / 0,93 0,91 0,86 0,75 Min 0,75 0,63 / / 0,77 0,72 0,55 / 0,81 0,78 0,73 0,57 Max 1 0,92 0,73 / 1 0,95 0,85 0,64 1 0,97 0,91 0,82 Med 0,89 0,79 0,42 / 0,90 0,84 0,71 / 0,91 0,88 0,82 0,69 Min 0,69 0,55 / / 0,72 0,65 0,46 / 0,76 0,73 0,66 0,48 Max 1 0,93 0,74 / 1 0,95 0,86 0,66 1 0,97 0,92 0,83 Med 0,89 0,80 0,45 / 0,91 0,85 0,73 / 0,92 0,89 0,83 0,71 Min 0,71 0,58 / / 0,74 0,68 0,49 / 0,77 0,74 0,68 0,50 Max 1 0,88 0,61 / 1 0,92 0,78 0,5 1 0,95 0,87 0,73 Med 0,83 0,69 0,26 / 0,85 0,77 0,59 / 0,87 0,82 0,74 0,56 Min 0,57 0,40 / / 0,60 0,52 0,30 / 0,65 0,61 0,53 0,32 Correction factors according to the altitude With altitudes on the sea level higher than 500 m, the different pressure may modify the nominal performances of the units. While the air flow does not change, the cooling and heating capacities are to be calculated with the correction factors shown in the table below. Altitude m 0 500 1.000 1.500 2.000 Total cooling capacity 1 0,98 0,95 0,92 0,89 Sensible cooling capacity 1 0,96 0,93 0,90 0,87 Heating capacity 1 0,97 0,94 0,91 0,88 Correction factors for glycoled water Glycoled water is used to prevent the heat exchangers of the chillers from freezing and to protect the hydraulic circuits from possible damages during long winter stops. The glycoled water modifies the cooling and heating performances of the unit, the water flow and the water pressure drops.. Glycol (weight ratio) % 10 20 30 40 50 Freezing point °C -3,6 -8,7 -15,3 -23,5 -35,5 Total cooling capacity 0,986 0,980 0,973 0,966 0,960 Sensible cooling capacity 0,986 0,980 0,973 0,9660 0,87 Heating capacity 0,986 0,980 0,973 0,91 0,88 Glycoled water flow 1,023 1,054 1,092 1,140 1,200 Glycoled water pressure drop 1,122 1,249 1,335 1,373 1,468 Selection manual 11 GB English The unit performances depend on the fan speed and the available static pressure. Use the correction factor shown in the table below to calcultate the air flows and the cooling or heating capacities referring to the nominal data. Fan coil - FFC 1206-6180658 WATER PRESSURE DROPS The pressure drops shown in the following diagrams refer to an average water temperature of 10°C. For different temperatures apply the correction factor k shown in the table below. °C 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 k 1,00 0,98 0,96 0,94 0,92 0,90 0,88 0,86 0,84 0,82 0,80 0,78 0,76 0,74 0,71 FFC15 FFC14 3 rows coil Water pressure drop (KPa) 100 80 FFC16 60 FFC18 40 30 FFC12 FFC20 FFC13 20 10 8 6 4 3 2 1 80 100 200 300 400 500 600 800 1000 2000 3000 4000 Water flow (l/h) FFC14 and FFC15 FFC16 FFC18 1 row coil Water pressure drop (KPa) 100 80 60 FFC12 FFC20 40 30 20 10 8 6 4 3 2 1 80 100 200 300 400 500 600 800 1000 2000 3000 4000 Water flow (l/h) Selection manual 12 GB Fan coil - FFC 1206-6180658 FAN PERFORMANCES Model FFC 12 Max 60 Available static pressure (Pa) 70 Limite di lavoro Work Limit 50 Med 40 Min 30 Model FFC 13 Limite di lavoro Work Limit Max 60 Available static pressure (Pa) 70 20 10 50 Med 40 Min 30 20 10 0 0 0 100 200 300 0 400 100 Air flow (m³/h) Model FFC 14 (Pa) 70 Limite di lavoro Work Limit 60 Max 50 Med 40 Min 30 20 10 0 100 200 300 400 Limite di lavoro Work Limit 60 Max 50 Med 40 Min 30 20 10 500 0 100 Med 60 Min 50 40 30 20 10 0 0 150 300 450 600 Max Med Min 900 Limite di lavoro Work Limit Max 70 Med 60 Min 50 40 30 20 10 0 200 400 600 800 1000 REMARKS: do not select the units with an operating point on the left of the shown working limit. Do not select the units with an available static pressure higher than the limit value, the air flow would result strongly reduced thus the fan motor would operate in dangerous conditions because of possible overheatings. Limite di lavoro Work Limit 600 500 Air flow (m³/h) Model FFC 20 300 400 Model FFC 18 80 0 750 Air flow (m³/h) 0 300 90 Available static pressure Available static pressure 70 (Pa) Limite di lavoro Work Limit Max 200 Air flow (m³/h) Model FFC 16 80 Available static pressure 400 Model FFC 15 Air flow (m³/h) (Pa) 110 100 90 80 70 60 50 40 30 20 10 0 300 0 0 (Pa) 200 Air flow (m³/h) Available static pressure Available static pressure (Pa) 70 English The following diagrams show the fan performances including the internal air pressure drops (standard unit with fan, coil, filter, main casing). The curves refer to the 3 speeds directly connected in the factory. 1200 1500 Air flow (m³/h) Selection manual 13 GB Fan coil - FFC 1206-6180658 SOUND LEVELS The sound levels of the different models are shown in the following tables depending on the fan speeds. The total sound pressure level is in dB(A) scale in open space (direction factor Q=1) a 2 m while the values in octave band are in dB scale. The sound power level is in dB(A) scale while the values in octave band are in dB scale. The NR, NC and RC sound level curves express an index for the noise level depending on the sound intensity and frequency Total level Models FFC 12 and FFC 13 Sound pressure (2 m - open space) Sound power UNI EN 23741 UNI EN 23742 Frequencies - Hz dB(A) NR NC RC 125 250 500 Min 28 23 22 22 N 33 36 36 31 30 23 15 Med 34 29 27 28 N 39 43 43 37 36 31 24 Max 38 34 33 33 N 43 48 48 42 41 35 28 Min 45 / / / 50 53 53 48 47 40 32 Med 51 / / / 56 60 60 54 53 48 41 Max 55 / / / 60 65 65 59 58 52 45 dB dB NR 80 dB NC 80 70 60 50 40 Max NR 40 Max Med NR 35 Med Min NR 30 30 125 250 500 1K Hz 2K 4K Sound power UNI EN 23741 UNI EN 23742 125 250 500 Min 29 25 23 23 N 25 29 29 23 18 10 8 Med 35 30 30 30 N 31 35 35 29 25 19 12 Max 40 35 34 35 N 36 39 39 34 31 25 17 Min 46 / / / 42 46 46 40 35 27 25 52 / / / 48 52 52 46 42 36 29 Max 57 / / / 53 56 56 51 48 42 34 dB NC 80 NR 55 60 NC 60 NR 35 Min NR 30 NR 25 50 NC 50 NR 15 125 250 500 1K Hz Selection manual 2K 4K 8K RC 65 RC 60 50 RC 55 NC 45 40 NC 40 Max 30 Med NC 30 Min NC 25 20 10 63 40 NC 35 NC 20 NR 20 10 63 60 NC 55 NR 40 Med RC B 70 NR 50 NR 45 A 80 NC 65 NR 60 20 1.000 2.000 4.000 8.000 Med NR 65 Max 4K RC 70 40 2K NC 70 50 RC 20 125 250 500 1K Hz Frequencies - Hz dB 60 10 31,5 63 8K NR NR 80 RC 25 dB(A) dB 30 4K RC 30 Total level Models FFC 14 and 15 Sound pressure (2 m - open space) NC 15 2K RC 35 20 NC 20 125 250 500 1K Hz RC 40 Min NC 25 10 63 RC 45 Max Med 30 NC 30 20 8K C NC 35 NR 20 NR 15 RC 50 40 NC 40 Min NR 25 10 63 RC 55 NC 45 NR 45 20 RC 60 50 NC 50 NR 50 30 RC 65 NC 55 NR 55 40 60 NC 60 NR 60 50 RC B NC 65 NR 65 60 A 80 70 70 1.000 2.000 4.000 8.000 NC 15 125 250 500 1K Hz 14 2K 4K 8K 30 RC 50 C Max Med Min RC 40 RC 35 RC 30 20 10 31,5 63 RC 45 RC 25 RC 20 125 250 500 1K Hz 2K 4K GB Fan coil - FFC 1206-6180658 Total level Model FFC 16 Sound pressure (2 m - open space) Sound power UNI EN 23741 UNI EN 23742 dB dB(A) NR NC RC 125 250 500 Min 30 26 24 24 N 28 31 30 23 18 11 8 Med 36 32 31 31 N 35 37 36 31 25 18 14 Max 42 37 36 37 N 40 42 41 37 33 26 18 Min 47 / / / 45 48 47 40 35 28 25 53 / / / 52 54 53 48 42 35 31 Max 59 / / / 57 59 58 54 50 43 35 dB dB NC 80 70 60 50 Max NR 45 Med NR 40 Med 30 Min NR 35 30 Min 40 NR 30 NR 25 2K 4K Sound power UNI EN 23741 UNI EN 23742 dB NR 65 NR 55 NR 40 NR 35 NR 30 NR 25 20 RC 125 250 500 Min 32 27 26 27 N 29 31 32 26 22 17 11 Med 38 34 34 33 N 34 37 38 32 29 24 17 Max 43 38 37 38 N 38 41 42 37 34 29 22 NR 15 125 250 500 1K Hz Selection manual 2K 4K 8K 1.000 2.000 4.000 8.000 Min 49 / / / 46 48 49 43 39 34 28 Med 55 / / / 51 54 55 49 46 41 34 Max 60 / / / 55 58 59 54 51 46 39 dB NC 80 70 A RC B NC 65 60 NC 60 60 RC 65 NC 55 50 NC 50 RC 60 50 RC 55 NC 45 40 Max NC 40 Med NC 35 30 Min NC 30 NC 25 20 NC 20 NR 20 10 63 4K NC NR 50 NR 45 2K NR NR 60 30 Min RC 20 125 250 500 1K Hz Frequencies - Hz 70 Med RC 25 dB(A) 80 70 40 Max RC 35 RC 30 10 31,5 63 8K dB NR 50 Min Total level Sound pressure (2 m - open space) 60 RC 45 Med 20 NC 15 125 250 500 1K Hz RC 50 Max RC 40 30 NC 30 NC 20 Model FFC 18 80 C NC 35 NC 25 10 63 8K 40 NC 40 20 NR 15 4K RC 55 NC 45 Max NR 20 2K RC 60 50 NC 50 NR 50 125 250 500 1K Hz RC 65 NC 55 NR 55 10 63 60 NC 60 NR 60 20 RC B NC 65 NR 65 50 A 80 70 70 60 1.000 2.000 4.000 8.000 Med NR 80 40 Frequencies - Hz 10 63 NC 15 125 250 500 1K Hz 2K 4K 15 8K 40 30 RC 50 C Max RC 45 Med RC 40 Min RC 35 RC 30 20 10 31,5 63 RC 25 RC 20 125 250 500 1K Hz 2K 4K GB English SOUND LEVELS Fan coil - FFC 1206-6180658 SOUND LEVELS Total level Model FFC 20 Sound pressure (2 m - open space) Sound level UNI EN 23741 UNI EN 23742 Frequencies- Hz dB(A) NR NC RC 125 250 500 Min 37 33 31 32 N 33 36 36 31 30 23 15 Med 44 39 38 39 N 39 43 43 37 36 31 24 Max 49 44 44 44 N 43 48 48 42 41 35 28 Min 54 / / / 50 53 53 48 47 40 32 Med 61 / / / 56 60 60 54 53 48 41 Max 66 / / / 60 65 65 59 58 52 45 dB dB NR 80 dB NC 80 NR 65 70 NR 55 50 60 NC 60 NR 45 40 Med NR 40 Min NR 35 50 NC 50 Max NC 45 40 Med NC 40 Min NC 35 30 NC 30 NR 30 NR 25 20 NC 25 20 NC 20 NR 20 10 63 NR 15 125 250 500 1K Hz Selection manual 2K 4K 8K RC B 60 RC 65 NC 55 NR 50 Max A NC 65 NR 60 30 80 70 70 60 1.000 2.000 4.000 8.000 10 63 NC 15 125 250 500 1K Hz 16 2K 4K 8K RC 60 50 40 30 RC 55 Max RC 50 C Med RC 45 Min RC 40 RC 35 RC 30 20 10 31,5 63 RC 25 RC 20 125 250 500 1K Hz 2K 4K GB Fan coil - FFC 1206-6180658 DIMENSIONS 10 L A Hydraulic connections 115 φ 1/2" 115 40 60 115 = 450 35 260 190 120 H 335 = 230 H = 470 35 135 70 25 155 S S = 220 S = 220 Dimensions in mm Model 13 14 15 16 18 20 L mm 670 670 870 870 1.070 1.270 1.470 H mm 470 470 470 470 470 470 470 S mm 220 220 220 220 220 220 220 A mm 400 400 600 600 800 1.000 1.200 2 pipes installation kg 13,5 14,0 16,4 17,2 22,5 26,0 30,0 4 pipes installation kg 13,8 14,3 16,7 17,5 22,8 26,4 30,5 Dimensions Net weight 12 L A 115 10 155 115 60 115 450 160 25 25 190 S = 220 160 155 S Model 12 13 14 15 16 18 20 L mm 670 670 870 870 1.070 1.270 1.470 H mm 470 470 470 470 470 470 470 S mm 220 220 220 220 220 220 220 A mm 400 400 600 600 800 1.000 1.200 2 pipes installation kg 13,8 14,3 16,9 17,7 23,2 26,9 31,1 4 pipes installation kg 14,1 14,6 17,2 18,0 23,5 27,3 31,6 Dimensions Net weight Selection manual 10 Dimensions in mm S = 220 25 H 120 155 35 260 = 335 = 230 H = 470 35 135 25 70 L Hydraulic connections 40 φ 1/2" φ 20 Condensate drain Vertical version wall installation FFC FV 17 GB English L 155 φ 20 Condensate drain Vertical version wall installation FFC W Fan coil - FFC 1206-6180658 DIMENSIONS Horizontal version ceiling installation FFC FO 450 335 Dimensions in mm Hydraulic connections 70 φ 1/2" 135 10 115 25 60 115 S = 220 155 40 260 φ 20 Condensate drain L A 25 L H H = 470 210 230 S 10 25 115 40 20 155 95 25 155 25 φ 20 Condensate drain = 120 = 240 80 160 Model 13 14 15 16 18 20 L mm 670 670 870 870 1.070 1.270 1.470 H mm 470 470 470 470 470 470 470 S mm 220 220 220 220 220 220 220 A mm 400 400 600 600 800 1.000 1.200 2 pipes installation kg 15,0 15,5 18,5 19,3 25,2 29,3 33,9 4 pipes installation kg 15,3 15,8 18,8 19,6 25,5 29,7 34,4 Dimensions Net weight 12 Horizontal or vertical version without cabinet FFC C H = 450 335 260 25 70 φ 1/2" Hydraulic connections 135 A 115 115 S = 215 60 15 105 H 25 15 25 110 30 40 25 40 Condensate drain φ 20 L A 40 S 25 90 φ 20 = = 120 H = 450 L 210 230 25 240 105 Condensate drain Dimensions in mm Model 12 13 14 15 16 18 20 L mm 545 545 745 745 945 1.145 1.345 H mm 450 450 450 450 450 450 450 S mm 215 215 215 215 215 215 215 A mm 400 400 600 600 800 1.000 1.200 2 pipes installation kg 11,1 11,6 13,9 14,7 19,9 23,3 27,2 4 pipes installation kg 11,4 11,9 14,2 15,0 20,2 27,3 27,7 Dimensions Net weight Selection manual 18 GB Fan coil - FFC 1206-6180658 The following table shows the compatibility between the various available accessories and the different versions and sizes of the FFC fan coils. In the following pages the various accessories with their main characteristics are described. Accessories FFC Fan coil Versions Size 12 12 13 • • 15 16 18 • W-FV-FO-C • 16 W-FV-FO-C • 18 20 KV11 KV12 PC1 PC2 CR1 CR2 CR11 SDI SMT1 BCV BCO ZC 12 14 PCB • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • W-FV-FO-C • • • • • • • • • • • • • W-FV-FO-C W-FV-FO-C W-FV-FO-C W-FV-FO W-FV-FO W-FV-FO-C W-FV-FO-C W-FV-FO-C W-FV-FO-C W-FV-FO-C W-FV-C (vertical) FO-C (horizontal) W W (without feet)-FV • W (without feet)-FV • W (without feet)-FV • 16 W (without feet)-FV • 18 • 20 Selection manual 20 W-FV-FO-C • 14 BA 14 19 W (without feet)-FV GB English ACCESSORIES COMPATIBILITY CHART Fan coil - FFC 1206-6180658 ACCESSORIES BA 1 row coil for 4 pipes installations The 1 row hot water coil is to be installed on the fan coil units for 4 pipes installation, on top of the standard 3 rows coil. It is possible to control the coil capacity by means of the 3 way valve KV12 accessory and a control panel or a remote panel chosen on the required functions. KV11 - 3 way valve for 2 pipes installations 3-way valve (4 connections) for 2 pipes installations with actuator 230V ON/OFF. The kit includes the copper pipes for the installation on board the unit. Reference Cool./Heat. 1 2 X mm 105 155 Y mm 270 260 Z mm 95 95 IN OUT Water 1 2 Connections (*) 3/4" M 3/4" M Valve pressure drops Kvs 2,5 2,5 Y Z (*) M = hydraulic connections Gas Male 0 X KV12 - Two 3 way valves for 4 pipes installations Two 3-way valves (4 connections) for 4 pipes installations with actuator 230V ON/OFF for each valve. The kit includes the copper pipes for the installation on board the unit. Riferimento Cool. 1 2 3 4 X mm 105 155 135 175 Y mm 270 260 345 335 Z mm 95 95 110 110 IN OUT IN OUT 3/4" M 3/4" M 1/2" M 1/2" M Water Connections (*) M = hydraulic connections Gas Male Heat. Valve pressure drops (*) Kvs 2,5 2,5 1,7 3 1 4 2 Y Z 0 1,7 X 3-way valves technical data Selection manual 1.600 kPa 150 kPa 3 m/s 5-100 °C 5-50 °C -25 / +65 °C 50 % 5W 230 V (+/-15%) /1ph / 50-60 Hz 90 s / 30 s IP 31 100 80 60 Water pressure drop (KPa) Max. static pressure Max. differential pressure Max. water speed Water temperature limits Room temperature limits Stocking temperature limits Max glycol ratio Input power Supply voltage Opening/Closing time IP protection class 40 30 Valves pressure drops Kvs 1,7 Kvs =Kvs 2,5= 2,5 Elettrovalvola 3-way valve a 3 3/4" vie 3/4” M Kvs =Kvs 1,7= 1,7 Elettrovalvola 3-way valve a 3 1/2" vie 1/2” M Kvs 2,5 20 10 8 6 4 3 2 1 80 100 200 300 400 500 600 800 1000 2000 3000 4000 Water flow (l/h) 20 GB Fan coil - FFC 1206-6180658 ACCESSORIES Control panel with ON/OFF switch and 3 available speeds. The control panel is suitable for units destined to 2 or 4 pipes installations. The control panel does not include the room thermostat and summer/winter switch functions. English PC1 Control panel OFF/3 speeds 1 0 2 1 3 0 PC2 Control panel OFF/3 speeds, room thermostat, summer/winter switch Control panel with ON/OFF switch and 3 available speeds. The control panel includes a bulb thermostat installed on the fan intake to control the room temperature; a summer/winter switch completes the functions of the control panel. The control panel is suitable for units destined to 2 or 4 pipes installations 1 0 2 1 3 0 STM1 Min. water temperature thermostat The min. water temperature thermostat gives a signal to allow the fans to operate. In case the water temperature is lower than 40°C, the thermostat stops the fans. Example of combined instalation PC1+SMT1. In this case the summer/winter switch is included. Example of combined installation PC2+SMT1. 1 1 0 0 2 1 2 3 1 0 Selection manual 3 0 21 GB Fan coil - FFC 1206-6180658 ACCESSORIES CR1 Remote panel 220V with OFF/summer/winter switch, 3 speeds control 90 Remote panel 220V with OFF/summer/winter and control of the 3 speeds of the unit. 30 65 I OFF II III CR2 Remote panel 220V with OFF/summer/winter switch, 3 speeds control, electronic thermostat Remote panel 220V with OFF/summer/winter switch and control of the 3 speeds of the unit. REMARK: the installation of the min. water temperature thermostat SMT1 is suggested to stop the unit if the water temperature should be lower than 40°C. In case of control of more units (up to 4 fan coils) by means of the SDI card install an SMT1 thermostat for each unit. I II III 20° CR11 Remote panel 220V with OFF/summer/winter switch, 3 speeds, electronic thermostat, temperature display Remote control 220V with OFF/summer/winter switch, control of the 3 speeds of the unit, electronic thermostat and temperature display. REMARK: the installation of the min. water temperature thermostat SMT1 is suggested to stop the unit if the water temperature should be lower than 40°C. In case of control of more units (up to 4 fan coils) by means of the SDI card install an SMT1 thermostat for each unit. SDI Interface card to control up to 4 units Interface card to control up to 4 units with 3 different available speeds, voltage supply 230 V, operating limits 0°C..+40°C. Box in tecnopolymer V0 class grey coloured (RAL 7035). 105 90 70 Selection manual 22 GB Fan coil - FFC 1206-6180658 ACCESSORIES H = 470 10 Auxiliary drain pan to collect the condensate from the valves and the pipes for the connection to the unit. The drain pan is made in plastic with external thermal insulation (M1 class), discharge pipe Ø 20 mm. This accessory is suitable for all the units with vertical installation, with coil connections either left or right. 80 55 45 80 100 100 155 25 5 80 25 25 Auxiliary drain pan φ 20 = 5 = 205 10 S = 220 205 80 Auxiliary drain pan Dimensions in mm φ 20 BCO Auxiliary condensate drain pan for HORIZONTAL versions 155 10 Condensate drain Dimensions in mm φ 20 H = 470 420 210 25 20 120 95 10 15 25 35 10 Auxiliary drain pan to collect the condensate from the valves and the pipes for the connection to the unit. The drain pan is made in plastic with external thermal insulation (M1 class), discharge pipe Ø 20 mm. This accessory is suitable for all the units with vertical installation, with coil connections either left or right sided 420 25 240 95 80 φ 20 Condensate drain 140 φ 20 Condensate drain Selection manual 23 GB English BCV Auxiliary condensate drain pan for VERTICAL versions Fan coil - FFC 1206-6180658 ACCESSORIES PCB Back cover panel Back cover panel for units in version W (vertical units with bottom intake) and in version FV (vertical with front intake). The accessory is not compatible with the accessory ZC. Model Dimensions L PCB 12 13 14 15 16 18 20 mm 640 640 840 840 1.040 1.240 1.440 450 L ZC Prepainted feet 90 Feet H=90 mm suitable for units in W version 90 Installation 40 220 135 Selection manual 24 GB Fan coil - FFC 1206-6180658 WARNING: before performing any operation on the unit make sure that the power suppy is disconnected. WARNING: before performing any intervention it is necessary to have proper individual protection devices. WARNING: the electrical connections, the installation of the fan coils and their accessories have to be carried out exclusively by personnel having the technical and professional skills to perform the installation, transformation, extension and maintenance of the equipment, and capable of checking the plants in terms of safety and correct operation. Specifically, for the electrical connections, it is necessary to check the following: - Measurement of the insulation resistance of the electrical system. - Testing of the continuity of the protection conductors. S P E C I F I C AT I O N O F T H E CONNECTION CABLES Use H05V-K or N07V-K type with 300/500 V insulation, piped or ducted. The cables coming out of the pipe or duct must not be subject to stretching or twisting and, in any case, protected by external agents. Stranded wires may only be used with terminating sleeves. For all connections please refer to the wiring diagrams suppied togeter with the unit and specified in this document. To protect the fan-coils against short circuits, fit the power cable to the units with a 2A 250V (IG) thermomagnetic all-pole switch with a minimum contact gap of 3 mm. Each panel can control only one fan-coil. The installation site must have a protection class equal to IP30 of the control panel. The control panel may not be installed on a metal wall, unless this is permanenty connected to earth. The control panel consists solely of electrical circuits connected to a 230V power suppy; all probe and control inputs must therefore be insulated accordingly. The control panels PC1 and PC2 may be combined with minimum water temperature thermostat. The minimum water temperature thermostat allows to shut down the ventilation automatically, whene- ver the inlet water temperature falls under 40°C. Similar functions are performed by the remote control panels CR1, CR2 and CR11 according to their technical characteristics described in the previous pages. By means of the interface card SDI it is possible to control more units (up to 4) with one single remote control. The following pages show some examples of electrical wirings between the units and the control panels or the interface card SDI. WARNING: ELECTRICAL WIRING DIAGRAMS SUBJECT TO UPDATES OR CHANGES, ALWAYS REFER TO THE ELECTRICAL WIRING DIAGRAMS SUPPLIED WITH THE UNITS. ELECTRICAL WIRINGS: REMOTE PANEL CR1 I OFF II III 1 2 3 4 5 6 7 8 9 FAN-COIL IG-2p Ph N Terminal plate Ph T N T 6 5 BL BL Bridge Com 4 BL Com III 3 II 2 RO BI III II I 1 MA G/V I Not supplied T Mors1 L (Com) 1(max) 2 3 4 5 6(min) T 230V – 1Ph – 50Hz G/ V 230 V – 1 Ph – 50 Hz CR1 AUTR M MA M BL MV C The 3 speeds connected to the autotransformer can be different from those indicated in the present wiring diagram. KEY CR1 MV C AUTR Mors1 T N Ph Com I, II, III = Remote control (230V) with OFF/Summer/Winter switch + 3 speeds without thermostat = Motor-Fan = Capacitor = Autotransformer = Terminal plate = Earth = Neutral (line 230V -1ph) = Phase (line 230V - 1ph) = Common = Fan minimum, average, maximum speeds Selection manual 25 G/V MA BL NE RO BI GR VI AR E I = Yellow/Green = Brown = Blue = Black = Red = White = Grey = Purple = Orange = Summer = Winter GB English ELECTRICAL CONNECTIONS Fan coil - FFC 1206-6180658 ELECTRICAL WIRINGS: REMOTE PANEL CR2 CR2 II III 20° 1 2 3 4 5 6 7 8 9 10 11 12 13 EV-C 230V Ph N 10 9 BL 8 7 BL 6 5 MA BL Com 4 BL Com III 3 II 2 RO BI III II I 1 MA G/V I EV-C EV-F 230V EV-F Ph Not supplied T N FAN-COIL Terminal plate IG-2p EV-C MA EV-F MA T T TM Mors1 L (Com) 1(max) 2 3 4 5 6(min) G/V 230 V – 1 Ph – 50 Hz I AUTR M MA M MV BL C The 3 speeds connected to the autotransformer can be different from those indicated in the present wiring diagram. T 230V – 1Ph – 50Hz ELECTRICAL WIRINGS: REMOTE PANEL CR11 L N E/I 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Bridge Ph EV-C-230V N Ph EV-F-230V BL 8 7 BL TM 6 5 N Ph Com 4 BL Com III 3 Ph II 2 RO BI III II Ph I 1 I T T MA G/V Not supplied T N Ph 10 9 Ph N N FAN-COIL Terminal plate IG-2p EV-C-230V EV-F-230V TM 230V EV-C-230V MA 230V EV-F-230V MA BL TM MA Mors1 T L (Com) 1(max) 2 3 4 5 6(min) T 230V – 1Ph – 50Hz G/V 230 V – 1 Ph – 50 Hz CR11 AUTR M MA M BL MVC C The 3 speeds connected to the autotransformer can be different from those indicated in the present wiring diagram. KEY CR1 MV C AUTR Mors1 T N Ph Com I, II, III TM EV-F EV-C = Remote control (230V) with OFF/Summer/Winter switch + 3 speeds without thermostat = Motor-Fan = Capacitor = Autotransformer = Terminal plate = Earth = Neutral (line 230V -1ph) = Phase (line 230V - 1ph) = Common = Fan minimum, average, maximum speeds = Termostato minima temperatura acqua = 3 way valve for 3R coil = 3 way valve for 1R coil Selection manual 26 G/V MA BL NE RO BI GR VI AR E I = Yellow/Green = Brown = Blue = Black = Red = White = Grey = Purple = Orange = Summertm = Winter GB Fan coil - FFC 1206-6180658 ELECTRICAL WIRINGS: REMOTE PANEL CR2 + INTERFACE CARD SDI FAN-COIL n° 1 10 9 BL 8 7 BL 6 5 BL BL Bridge Com 4 BL Com III 3 II 2 RO BI III II I 1 MA G/V I II III 20° 1 2 3 4 5 6 7 8 9 10 11 12 13 IG-2p 230V M MA M BL MV C The 3 speeds connected to the autotransformer can be different from those indicated in the present wiring diagram. T II III 2 Com 3 I 4 II 5 III 6 9 10 11 IG-2p 12 Ph N 13 Ph 14 N Not supplied 15 Ph 16 N 17 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 8 7 BL 6 5 BL BL Bridge EV-C MA EV-F MA T 4 BL Com 3 II 2 RO BI III II I Com 1 MA G/V I T Mors1 III L (Com) 1(max) 2 3 4 5 6(min) AUTR M MA M BL MV C The 3 speeds connected to the autotransformer can be different from those indicated in the present wiring diagram. T II I Com FAN-COIL n° 3 III II I Com III II I Com 35 10 9 BL 8 7 BL 6 5 BL BL Bridge 4 BL Com 3 RO BI III II MA G/V I EV-F MA 2 1 N EV-C MA T T 230 V – 1 Ph – 50 Hz Mors1 L (Com) 1(max) 2 3 4 5 6(min) G /V I BL G/ V I II III Com 230 V – 1 Ph – 50 Hz Com 19 10 9 III 18 1 8 AUTR M MA M BL MV C The 3 speeds connected to the autotransformer can be different from those indicated in the present wiring diagram. T FAN-COIL n° 4 10 9 BL 8 7 BL 6 5 BL BL Bridge Com 4 BL Com III 3 II 2 RO BI III II I 1 MA G/V I T 230V – 1Ph – 50Hz EV-C MA EV-F MA T T N AUTR FAN-COIL n° 2 7 Ph L (Com) 1(max) 2 3 4 5 6(min) EV-F EV-F SDI Mors1 T L (Com) 1(max) 2 3 4 5 6(min) T G/V Ph T Mors1 N Ph Not supplied EV-F MA T EV-C 230V EV-C Ph N English 230 V – 1 Ph – 50 Hz I EV-C MA G/V CR2 AUTR M MA M BL MV C The 3 speeds connected to the autotransformer can be different from those indicated in the present wiring diagram. KEY CR1 MV C AUTR Mors1 T N Ph Com I, II, III TM EV-F EV-C = Remote control (230V) with OFF/Summer/Winter switch + 3 speeds without thermostat = Motor-Fan = Capacitor = Autotransformer = Terminal plate = Earth = Neutral (line 230V -1ph) = Phase (line 230V - 1ph) = Common = Fan minimum, average, maximum speeds = Termostato minima temperatura acqua = 3 way valve for 3R coil = 3 way valve for 1R coil Selection manual 27 G/V MA BL NE RO BI GR VI AR E I = Yellow/Green = Brown = Blue = Black = Red = White = Grey = Purple = Orange = Summertm = Winter GB Fan coil - FFC 1206-6180658 TRANSPORT DO NOT wet D O N OT l e ave l o o s e package during transport DO NOT trample DO NOT carry the unit alone if the weight is over 35 Kg PACKING The fan-coils are despatched in standard boxes, made from cardboard and polystirene shells. Selection manual 28 GB NOTES NOTES NOTES 1206 - 6180658 Manuale stampato su carta riciclata. Manual printed on recycled paper. Technical data shown in this booklet are not binding. FAST S.p.A. shall have the right to introduce at any time whatever modifications deemed necessary to the improvement of the product. FAST S.p.A. TRATTAMENTO DELL'ARIA 35044 Montagnana (PD) - Italy Via Luppia Alberi, 170 Tel. (+39) 0429 806311 - Fax 0429 806340 E-mail: [email protected] http://www.fastaer.com