Transcript
NEC EXPRESS5800/R320c-M4 Configuration Guide VMware model
Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC EXPRESS5800 server.
June 2014 Revision 4.1 NEC Corporation
CONFIGURATION GUIDE – NEC EXPRESS5800/R320c-M4 / VMware model
Contents TECHNICAL SPECIFICATION ........................................................................................ 3 Key Features .......................................................................................................................................... 3 Specification .......................................................................................................................................... 3
EXTERNAL VIEWS ......................................................................................................... 5 Front and Rear Views ........................................................................................................................... 5 Dimensions (mm) .................................................................................................................................. 7
CONFIGURATION DIAGRAM ......................................................................................... 8 SERVER CONFIGURATION ........................................................................................... 9 1 2 3 4 5 6
7 8
Base Models ................................................................................................................................... 9 2nd Processor ................................................................................................................................ 9 Memory ........................................................................................................................................... 9 Internal Hard Disk Drives ............................................................................................................ 11 Optical Drive ................................................................................................................................. 11 PCI Card ........................................................................................................................................ 11 6.1 LAN Controller ..................................................................................................................... 11 6.2 Fibre Channel ...................................................................................................................... 12 Other Add-in Components .......................................................................................................... 12 7.1 Input Devices ....................................................................................................................... 12 Add-on Components ................................................................................................................... 13 8.1 17-inch LCD Console Drawer .............................................................................................. 13 8.2 KVM Switch ......................................................................................................................... 13 8.3 Flash FDD............................................................................................................................ 13 8.4 Operating System ................................................................................................................ 14 8.5 ft Server Control Software Support Service ........................................................................ 14 8.6 Tower Conversion Kit ........................................................................................................... 14
REFERENCES............................................................................................................... 15 Server Management ............................................................................................................................ 15 Supported PCI Cards and Installable Slots ...................................................................................... 16 Notes for using VMware vSphere 5.1 on Express5800/R320c ........................................................ 16 Copyright Notice and Liability Disclaimer ........................................................................................ 17
REVISION HISTORY ..................................................................................................... 18
NEC Corporation
Revision 4.1, June 2014
2
CONFIGURATION GUIDE – NEC EXPRESS5800/R320c-M4 / VMware model
Technical Specification Key Features
TM
Fault tolerant technology based on GeminiArchitecture Full manageability by integrated EXPRESSSCOPE Engine 3 High performance with the latest Intel® Xeon® processor E5-2600 product family Up to 256GB of high speed DDR3L-1600 memory
Specification Model
R320c-M4
Part Number Processor
NP8800-174FP1 Type
Intel® Xeon® processor E5-2670
Clock speed
2.60 GHz
Logical Number of Processors Cache
1 or 2
Cores and Threads
8C / 16T TM
Chipset Memory
Internal Storage
Expansion Slots [free] Video
20 MB Intel® C602 Chipset with GeminiEngine
Type
DDR3L-1600 Registered DIMM with ECC
Memory Clock
1333Mhz
Logical Standard Capacity Logical Maximum Capacity Memory protection
0GB
Standard Capacity
0GB
Maximum Logical Capacity Disk Controller
9.6 TB (8 x 1.2TB)
RAID
SAS : RAID 1 (Standard)
Hot Plug
Supported
Optical Disk Drive
DVD Super Multi drive
Optical Drive Bays [free] Logical Disk Drive Bays [free] Standard
1 [0]
Controller (VRAM)
Integrated in Server Management Controller (32MB)
Resolution / Color Supported
800 x 600 / 16.7M, 1024 x 768 / 16.7M, 1280 x 1024 / 65K
256GB (16 x 16 GB) ECC, x4 SDDC
SAS: 6Gb/s (Standard)
1
8 [8] Total: 4 slots available 2 Low-profile PCIe x4 Gen 2 (x8 connector) 2 Full-height PCIe x8 Gen 2 (x8 connector)
Interfaces
1 VGA (15-pin mini D-sub, 1 rear per system) 4 USB2.0 (1 front, 3 rear per system) 4 10GBASE-T LAN connector (RJ-45, 2 rear per module) 4 1000BASE-T LAN connector (RJ-45, 2 rear per module) 2 Management LAN connector (RJ-45, 1 rear per module)
Server Management
EXPRESSSCOPE Engine 3
Power Supply
2 x 800 Watt (1 per module, 80 PLUS® Platinum certified) 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
NEC Corporation
Revision 4.1, June 2014
3
CONFIGURATION GUIDE – NEC EXPRESS5800/R320c-M4 / VMware model Model Power (Max. Config, Consumption Operating) Dimensions (W x D x H )
1
R320c-M4 1,300 VA / 1,290 Watt 483.0 x 736.0 x 178 mm / 19.0 x 29.0 x 7.0 in (4U)
Weight (Minimum / Maximum)
45 kg / 51 kg, 99.21 lbs. / 112.44 lbs.
Temperature, Relative Humidity (non-condensing)
Operating: 10° to 35° C / 50° to 95° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
Regulatory and Safety
FCC, CE, BSMI, CCC, UL, CB, RoHS
Operating Systems
VMware ESXi 5.1, VMware ESXi 5.1 Update1
Writing software is not provided for this DVD drive.
NEC Corporation
Revision 4.1, June 2014
4
CONFIGURATION GUIDE – NEC EXPRESS5800/R320c-M4 / VMware model
External Views Front and Rear Views Front View B
A
C D
E F
G
H I J
A
N
B K
L
M
P
Q
R
O
S
T
U
Legend A.
Drive Bays
L.
CPU Fault LED
B.
UID Button
M.
Memory Fault LED
C.
DVD Super Multi Drive
N.
Module Power LED
D.
System Power LED
O.
SAFE TO PULL LED PRIMARY LED
E.
System Status LED
P.
F.
System FT LED
Q.
IO Module Fault LED
G.
UID LED
R.
Fan Fault LED
H.
USB Connector
S.
PSU Fault LED
I.
Pull-out Tab
T.
DC Power Fault LED
J.
Power Button
U.
Temperature Fault LED
K.
Module ID LED
NEC Corporation
Revision 4.1, June 2014
5
CONFIGURATION GUIDE – NEC EXPRESS5800/R320c-M4 / VMware model
Rear View B
C
D
D
E
E
A
F
H
I
J
G
Legend
1
A.
USB Connectors
B.
F.
AC Inlet
Management LAN Connector
G.
PCI Slots (Low-Profile)
C.
Module ID LED
H.
PCI Slots (Full-Height)
D.
Data LAN Connectors (10GBase-T)
I.
Serial Port Connector
E.
Data LAN Connectors (1000Base-T)
J.
VGA Connector
For service personnel only.
NEC Corporation
Revision 4.1, June 2014
6
CONFIGURATION GUIDE – NEC EXPRESS5800/R320c-M4 / VMware model
Dimensions (mm) Rack mount
748.5 736
177
448
485
688.5
Tower Conversion (Optional) 220
804
592
327
NEC Corporation
Revision 4.1, June 2014
7
CONFIGURATION GUIDE – NEC EXPRESS5800/R320c-M4 / VMware model
Configuration Diagram Server CHASSIS REAR
CHASSIS FRONT HDD Bay
HDD Bay HDD Bay
HDD Bay
HDD Bay
HDD Bay
HDD Bay
HDD Bay HDD Bay
HDD Bay
HDD Bay HDD Bay HDD Bay
HDD Bay
HDD Bay
Backplane
CPU/IO Module
HDD Bay
Optical Drive Bay
CPU/IO Module
PCIe 2.0 x8 (x8 socket) FH
HDD Bay
HDD Bay
CHASSIS FRONT
Drive Cage HDD Bay
DIMM #8 DIMM #7 DIMM #6 DIMM #5 DIMM #9 DIMM #10 DIMM #11 DIMM #12
PCI Riser
Cooling Fan #1 - #4
Processor
HDD Bay
DIMM #1 DIMM #2 DIMM #3 DIMM #4
HDD Bay
CHASSIS REAR
HDD Bay
CPU/IO module #0 :
Power Supply
DIMM #16 DIMM #15 DIMM #14 DIMM #13
HDD Bay
HDD Bay
Processor PCIe 2.0 x4 (x8 socket) LP PCIe 2.0 x4 (x8 socket) LP
HDD Bay HDD Bay HDD Bay HDD Bay
Drive Cage HDD Bay
PCIe 2.0 x8 (x8 socket) FH
HDD Bay
DIMM #8 DIMM #7 DIMM #6 DIMM #5 DIMM #9 DIMM #10 DIMM #11 DIMM #12
PCI Riser
Cooling Fan #1 - #4
Processor
HDD Bay
DIMM #1 DIMM #2 DIMM #3 DIMM #4
HDD Bay
CPU/IO module #1 :
Processor PCIe 2.0 x4 (x8 socket) LP PCIe 2.0 x4 (x8 socket) LP
Power Supply
Legend:
NEC Corporation
DIMM #16 DIMM #15 DIMM #14 DIMM #13
Minimum required components
Revision 4.1, June 2014
Standard components
8
CONFIGURATION GUIDE – NEC EXPRESS5800/R320c-M4 / VMware model
Server Configuration 1 Base Models Product Name / Description
Part Number
EXPRESS5800/R320c-M4 no RAM, no 2.5-inch HDD Including: Intel Xeon Processor E5-2670, 1 x DVD Super Multi, EXPRESSBUILDER DVD, ftSys for VMware vSphere5.1
NP8800-174FP1
2 2nd Processor Available logical sockets: 1 Product Name / Description
Part Number
Intel® Xeon® Processor E5-2670 2nd Processor Kit : 2.6 GHz / 8C-16T / 20 MB, 2 processors included
N8801-045
3 Memory Available logical slots: 8 per processor Product Name / Description
Part Number
4GB DDR3-1600 REG Memory Kit : 2 x 1 x 4GB DIMM included
N8802-057
32GB DDR3-1600 REG Memory Kit : 2 x 4 x 8GB DIMM included
N8802-058
64GB DDR3-1600 REG Memory Kit : 2 x 4 x 16GB DIMM included
N8802-059
NOTE:
Minimum one memory kit must be installed.
NEC Corporation
Revision 4.1, June 2014
9
CONFIGURATION GUIDE – NEC EXPRESS5800/R320c-M4 / VMware model
Memory Configuration Guideline See the table below for the number of memory kits required in accordance with logical main memory size and number of logical processors. Memory configurations which are not listed below are not supported in the system.
Number of Logical Processors
1
Logical Main Memory Size
4GB
2
1
4GB
32GB
64GB
1
-
-
8GB
2
-
-
12GB
3
-
-
16GB
4
-
-
20GB
5
-
-
24GB
6
-
-
28GB
7
-
-
32GB
8
-
-
-
1
-
48GB
4
1
-
64GB
-
2
-
64GB
-
-
1
96GB
-
1
1
128GB
-
-
2
1
-
-
2
-
-
4GB
1
8GB
1
12GB
1
Number of Memory Kits Required
1
3
-
-
16GB
4
-
-
24GB
6
-
-
32GB
8
-
-
40GB
10
-
-
48GB
12
-
-
56GB
14
-
-
64GB
16
-
-
-
2
-
96GB
8
2
-
128GB
-
4
-
-
-
2
192GB
-
2
2
256GB
-
-
4
Interleave is not supported.
NEC Corporation
Revision 4.1, June 2014
10
CONFIGURATION GUIDE – NEC EXPRESS5800/R320c-M4 / VMware model
4 Internal Hard Disk Drives Available bays: 8 Category
Product Name / Description
Part Number
SAS HDD
600GB 10K Hot Plug 2.5-inch SAS HDD : 1 x 600GB
N8850-047
900GB 10K Hot Plug 2.5-inch SAS HDD : 1 x 900GB
N8850-048
1.2TB 10K Hot Plug 2.5-inch SAS HDD : 1 x 1.2TB
N8850-051
146.5GB 15K Hot Plug 2.5-inch SAS HDD : 1 x 146.5GB
N8850-049
300GB 15K Hot Plug 2.5-inch SAS HDD : 1 x 300GB
N8850-050
200GB Hot Plug 2.5-inch SSD: 1 x 200GB
N8850-052
SAS SSD
NOTE: Hard drives must be installed in identical pairs to configure RAID 1. The 146.5GB HDD is recommended to install as the system drive in order to reduce the time to resynchronize.
5 Optical Drive Available bays: 1 Product Name / Description
Part Number
Internal DVD Super Multi Drive : 1 x DVD Super Multi drive, not including writing software
(Standard)
6 PCI Card 6.1 LAN Controller Category
Product Name / Description
Part Number
LAN Controller
1000BASE-T 2ch board kit : 2 x GbE NIC Intel® Gigabit ET Dual Port Server Adapter 10GBASE-T 1ch Adapter Kit : 2 x 10GbE NIC Intel® X540-T1 NOTE: - Up to one controller per module - Installation in full height slots only supported on R320c-M4 - FCoE functionality is not supported
N8804-009
NEC Corporation
Revision 4.1, June 2014
N8804-011
11
CONFIGURATION GUIDE – NEC EXPRESS5800/R320c-M4 / VMware model
6.2 Fibre Channel Category
Product Name / Description
Part Number
Fibre Channel Controller
Fibre Channel board kit (8Gbps) : 2 x FC Controller QLogic QLE2560 8Gbps Fibre Channel Adapters NOTE: Installation in full height slots only supported on R320c-M4
N8803-038
NOTE:
For supported NEC Storage products to connect with N8803-038, contact your sales representative or refer to the NEC Storage WEB site. (http://www.nec.com/global/prod/storage/)
7 Other Add-in Components 7.1 Input Devices Category
Product Name / Description
Part Number
Keyboard
USB Keyboard
N8870-002AF
Mouse
USB Optical Wheel Mouse
N8870-012
Cable
USB cable : 1.5m USB extension cable
K410-177(1A)
NEC Corporation
Revision 4.1, June 2014
12
CONFIGURATION GUIDE – NEC EXPRESS5800/R320c-M4 / VMware model
8 Add-on Components 8.1 17-inch LCD Console Drawer Category Drawer w/ KVM Switch
Product Name / Description
Part Number
Drawer
17inch LCD Console Unit (1U/8port) 17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM switch, 1U height
N8143-77F
Cable
Switch Unit Connection Cable Set (USB, 1.8m) 1.8 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 3m) 3 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 5m) 5 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin USB A 17inch LCD Console Unit 1U 17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 4-pin USB B to 4-pin USB A cable 2m, PS/2 Y-splitter cable 2m, 15-pin mini D-sub VGA cable 2m 17inch LCD Console Drawer (1port) 17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8 m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m Keyboard Unit (JP) JP 108-keys Keyboard with 10-key for N8143-84F 17inch LCD Console Drawer (1port) Keyboard Unit (UK) UK 104-keys Keyboard with 10-key, for N8143-84F 17inch LCD Console Drawer (1port)
K410-118(1A)
Drawer
Drawer w/o KVM Switch
Keypad
K410-118(03)
K410-118(05)
N8143-76F
N8143-84F
N8143-85
N8143-87
8.2 KVM Switch Category
Product Name / Description
Part Number
KVM Switch
Server Switch Unit (8 server) 1U USB 8 port KVM switch
N8191-12F
Switch Unit Connection Cable Set (USB,1.8m) 1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable 1.8 m 1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2
K410-118(1A)
Cable
KVM
Cascading
K410-118(03)
K410-118(05)
K410-119(1A)
8.3 Flash FDD Order the Flash FDD if you need to prepare an alternative for a floppy drive. Product Name / Description
Part Number
Flash FDD USB flash emulating USB floppy disk, Native capacity 1.44 MB
N8160-86
NEC Corporation
Revision 4.1, June 2014
13
CONFIGURATION GUIDE – NEC EXPRESS5800/R320c-M4 / VMware model
8.4 Operating System The R320c VMware models support VMware vSphere 5.1 and 5.1 Update 1. For installation, please download the image data from VMware website. Please note that the Part Number differs by the end user’s country. Part Number For APAC&LATAM
Part Number For Europe
Part Number For MEA & Russia
Part Number For China
UL1560-0A1E-I
UL1560-0B1E-I
UL1560-0D1E-I
UL1560-0G1E-I
ULH1S1560015E-I
ULH1S1560023E-I
ULH1S1560031E-I
ULH1S1560039E-I
UL1560-0A2E-I
UL1560-0B2E-I
UL1560-0D2E-I
UL1560-0G2E-I
ULH1S1560016E-I
ULH1S1560024E-I
ULH1S1560032E-I
ULH1S1560040E-I
UL1560-0A3E-I
UL1560-0B3E-I
UL1560-0D3E-I
UL1560-0G3E-I
ULH1S1560017E-I
ULH1S1560025E-I
ULH1S1560033E-I
ULH1S1560041E-I
UL1560-0A4E-I
UL1560-0B4E-I
UL1560-0D4E-I
UL1560-0G4E-I
ULH1S1560018E-I
ULH1S1560026E-I
ULH1S1560034E-I
ULH1S1560042E-I
UL1560-0A5E-I
UL1560-0B5E-I
UL1560-0D5E-I
UL1560-0G5E-I
ULH1S1560019E-I
ULH1S1560027E-I
ULH1S1560035E-I
ULH1S1560043E-I
VMware vCenter Server 5 Foundation
UL1560-0A7E-I
UL1560-0B7E-I
UL1560-0D7E-I
UL1560-0G7E-I
PPSupportPack(VMware vCenter Server 5 Foundation)(1year)
ULH1S1560021E-I
ULH1S1560029E-I
ULH1S1560037E-I
ULH1S1560045E-I
VMware vCenter Server 5 Standard
UL1560-0A8E-I
UL1560-0B8E-I
UL1560-0D8E-I
UL1560-0G8E-I
PPSupportPack(VMware vCenter Server 5 Standard)(1year)
ULH1S1560022E-I
ULH1S1560030E-I
ULH1S1560038E-I
ULH1S1560046E-I
Product Name / Description
VMware vSphere 5 license for Small Business: VMware vSphere 5 Essentials for 3 hosts ESX license for up to 3 Physical servers (Max 2 CPUs each) and VMware vCenter Server license for 3 ESX servers. PPSupportPack(VMware vSphere 5 Essentials for 3 hosts)(1year) VMware vSphere 5 Essentials Plus for 3 hosts ESX license for up to 3 Physical servers (Max 2 CPUs each) and VMware vCenter Server license for 3 ESX servers. Also, Data Recovery and HA license for 6 CPUs included. PPSupportPack(VMware vSphere 5 Essentials Plus for 3 hosts)(1year)
VMware vSphere 5 license for Medium and Large-sized Business VMware vSphere 5 Standard for 1processor Note: VMware vCenter Server license is not included. PPSupportPack(VMware vSphere 5 Standard for 1processor)(1year) VMware vSphere 5 Enterprise for 1processor Note: VMware vCenter Server license is not included. PPSupportPack(VMware vSphere 5 Enterprise for 1processor)(1year) VMware vSphere 5 Enterprise Plus for 1processor Note: VMware vCenter Server license is not included. PPSupportPack(VMware vSphere 5 Enterprise Plus for 1processor)(1year)
VMware vSphere 5 vCenter Server
8.5 ft Server Control Software Support Service For R320c VMware model, please also order below support product for ft Server Control Software support. Product Name / Description
Part Number
PPSupportPack(1year support of ftSys for VMware vSphere5.1)
ULH1S-1377-002F
Software support service for ft Server Control Software for vSphere 5.1
8.6 Tower Conversion Kit Product Name / Description
Part Number
Tower Conversion Kit 23 inch height pedestal with front bezel
N8843-004
NEC Corporation
Revision 4.1, June 2014
14
CONFIGURATION GUIDE – NEC EXPRESS5800/R320c-M4 / VMware model
References Server Management The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features listed in the table below.
Temperature/voltage/power/fan
Degeneration (memory/hard drive)
-
Hardware event log collection
Boot monitoring
Booting, BIOS/POST stall, OS stall, shutdown
Alerting
HW error, Boot error and OS panic (by SNMP, E-Mail)
Remote KVM
POST/BIOS setup, DOS utility
(via LAN)
Panic screen, Boot screen
Text-based screen (OS console)
GUI-based screen (OS console)
Remote console recording
-
Remote control
Remote reset/power on-off/ dump
(via LAN)
OS shutdown
Remote media (CD/DVD/FD)
Server Management Command Line Protocol (DMTF compliant)
Remote control via Web browser (without dedicated app)
Scheduling (without UPS)
-
Others
Set automatic IP address via DNS/DHCP
Industry standard
IPMI
2.0
Hardware monitoring
NEC Corporation
Revision 4.1, June 2014
15
CONFIGURATION GUIDE – NEC EXPRESS5800/R320c-M4 / VMware model
Supported PCI Cards and Installable Slots Part Number
Slots
Notes
Slot # :
#1
#2
#3
#4
PCI Slot:
x4
x4
x8
x8
Card height:
LP
LP
FH
FH
Slot type:
x8
x8
x8
x8
N8804-009
1000BASE-T 2ch board kit
N8804-011
10GBASE-T 1ch board set
-
-
N8803-038 1
Product Name
Fibre Channel board kit
-
-
1
Max. 1 1
Not installable when using Tower Conversion Kit.
Notes for using VMware vSphere 5.1 on Express5800/R320c Supported Guest OS Guest Operating Systems supported on NEC Express5800/ft series are the same as other general purpose servers. Refer to the VMware web site for the Supported Guest Operating Systems on VMware vSphere ESXi 5.1
VMware vSphere Client For maintenance of VMware ESX on the NEC Express5800/ft series, a dedicated terminal (e.g. a Windows PC) is required
Backup A dedicated server for data backup is recommended.
NEC Corporation
Revision 4.1, June 2014
16
CONFIGURATION GUIDE – NEC EXPRESS5800/R320c-M4 / VMware model
Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. VMware is a registered trademark or trademark of VMware, Inc. in the United States and/or other jurisdictions. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less.
NEC Corporation
Revision 4.1, June 2014
17
CONFIGURATION GUIDE – NEC EXPRESS5800/R320c-M4 / VMware model
Revision History Revision
Date
Description
4.1
2014.6.23
Others: Memory product name corrected
4.0
2014.6.16
New products added: 200GB Hot Plug 2.5-inch SSD N8850-052
3.0
2014.4.28
New products added: 1.2TB 10K Hot Plug 2.5-inch SAS HDD N8850-051 Others: ESXi5.1 Update 1 supported
2.0
2013.11.20
New products added: Memory Kit N8802-057/058/059 Discontinued products removed: Memory Kit N8802-054/055/056 Others: VMware vSphere license Part Numbers changed
1.0
2013.9.13
Initial release
NEC Corporation
Revision 4.1, June 2014
18