NEC EXPRESS5800/R320d-M4 Configuration Guide Windows Server model
Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC EXPRESS5800 server.
April 2014 Revision 4.0 NEC Corporation
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
Contents TECHNICAL SPECIFICATION ........................................................................................ 3 Key Features .......................................................................................................................................... 3 Specification .......................................................................................................................................... 3
EXTERNAL VIEWS ......................................................................................................... 5 Front and Rear Views ........................................................................................................................... 5 Dimensions (mm) .................................................................................................................................. 7
CONFIGURATION DIAGRAM ......................................................................................... 8 SERVER CONFIGURATION ........................................................................................... 9 1 2 3 4 5 6
7 8
Base Models ................................................................................................................................... 9 2nd Processor ................................................................................................................................ 9 Memory ........................................................................................................................................... 9 Internal Hard Disk Drives ............................................................................................................ 11 Optical Drive ................................................................................................................................. 12 PCI Card ........................................................................................................................................ 12 6.1 LAN Controller ..................................................................................................................... 12 6.2 Fibre Channel / SAS Controller ........................................................................................... 12 Other Add-in Components .......................................................................................................... 12 7.1 Input Devices ....................................................................................................................... 12 Add-on Components ................................................................................................................... 13 8.1 17-inch LCD Console Drawer .............................................................................................. 13 8.2 KVM Switch ......................................................................................................................... 13 8.3 Flash FDD............................................................................................................................ 14 8.4 Operating System ................................................................................................................ 14 TM 8.5 Active Upgrade ................................................................................................................. 14 8.6 Tower Conversion Kit ........................................................................................................... 14 8.7 External Tape Drives ........................................................................................................... 15
REFERENCES............................................................................................................... 18 Server Management ............................................................................................................................ 18 Supported PCI Cards and Installable Slots ...................................................................................... 19 Notes for using Hyper-V ..................................................................................................................... 20 Copyright Notice and Liability Disclaimer ........................................................................................ 22
REVISION HISTORY ..................................................................................................... 23
NEC Corporation
Revision 4.0, April 2014
2
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
Technical Specification Key Features
TM
Fault tolerant technology based on GeminiArchitecture Full manageability by integrated EXPRESSSCOPE Engine 3 High performance with the latest Intel® Xeon® processor E5-2600 v2 product family Up to 256GB of high speed DDR3L-1600 memory
Specification Model
R320d-M4
Part Number Processor
N8800-185F Type
Intel® Xeon® processor E5-2670 v2
Clock speed
2.50 GHz
Logical Number of Processors Cache
1 or 2
Cores and Threads
10C / 20T TM
Chipset Memory
Internal Storage
Expansion Slots [free] Video
25 MB Intel® C602 Chipset with GeminiEngine
Type
DDR3L-1600 Registered DIMM with ECC
Memory Clock
1600MHz
Logical Standard Capacity Logical Maximum Capacity Memory protection
0GB
Standard Capacity
0GB
Maximum Logical Capacity Disk Controller
9.6 TB (8 x 1.2TB)
RAID
SAS : RAID 1 (Standard)
Hot Plug
Supported
Optical Disk Drive
DVD Super Multi drive
Optical Drive Bays [free] Logical Disk Drive Bays [free] Standard
1 [0]
Controller (VRAM)
Integrated in Server Management Controller (32MB)
Resolution / Color Supported
800 x 600 / 16.7M, 1024 x 768 / 16.7M, 1280 x 1024 / 65K
256GB (16 x 16 GB) ECC, x4 SDDC
SAS: 6Gb/s (Standard)
1
8 [8] Total: 4 slots available 2 Low-profile PCIe x4 Gen 2 (x8 connector) 2 Full-height PCIe x8 Gen 2 (x8 connector)
Interfaces
1 VGA (15-pin mini D-sub, 1 rear per system) 4 USB2.0 (1 front, 3 rear per system) 4 10GBASE-T LAN connector (RJ-45, 2 rear per module) 4 1000BASE-T LAN connector (RJ-45, 2 rear per module) 2 Management LAN connector (RJ-45, 1 rear per module)
Server Management
EXPRESSSCOPE Engine 3
Power Supply
2 x 800 Watt (1 per module, 80 PLUS® Platinum certified) 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
NEC Corporation
Revision 4.0, April 2014
3
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model Model Power (Max. Config, Consumption Operating) Dimensions (W x D x H )
1
R320d-M4 1,300 VA / 1,290 Watt 483.0 x 736.0 x 178 mm / 19.0 x 29.0 x 7.0 in (4U)
Weight (Minimum / Maximum)
45 kg / 51 kg, 99.21 lbs. / 112.44 lbs.
Temperature, Relative Humidity (non-condensing)
Operating: 10° to 35° C / 50° to 95° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
Regulatory and Safety
FCC, CE, BSMI, CCC, UL, CB, RoHS
Operating Systems
Microsoft Windows Server® 2008 R2 Enterprise SP1 Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter
Writing software is not provided for this DVD drive.
NEC Corporation
Revision 4.0, April 2014
4
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
External Views Front and Rear Views Front View B
A
C D
E F
G
H I J
A
N
B K
L
M
P
Q
R
O
S
T
U
Legend A.
Drive Bays
L.
CPU Fault LED
B.
UID Button
M.
Memory Fault LED
C.
DVD Super Multi Drive
N.
Module Power LED
D.
System Power LED
O.
SAFE TO PULL LED
E.
System Status LED
P.
PRIMARY LED
F.
System FT LED
Q.
IO Module Fault LED
G.
UID LED
R.
Fan Fault LED
H.
USB Connector
S.
PSU Fault LED
I.
Pull-out Tab
T.
DC Power Fault LED
J.
Power Button
U.
Temperature Fault LED
K.
Module ID LED
NEC Corporation
Revision 4.0, April 2014
5
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
Rear View B
C
D
D
E
E
A
F
H
I
J
G
Legend A.
1
USB Connectors
F.
AC Inlet
B.
Management LAN Connector
G.
PCI Slots (Low-Profile)
C.
Module ID LED
H.
PCI Slots (Full-Height)
D.
Data LAN Connectors (10GBase-T)
I.
Serial Port Connector
E.
Data LAN Connectors (1000Base-T)
J.
VGA Connector
1
For service personnel only.
NEC Corporation
Revision 4.0, April 2014
6
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
Dimensions (mm) Rack mount
748.5 736
177
448
485
688.5
Tower Conversion (Optional) 220
804
592
327
NEC Corporation
Revision 4.0, April 2014
7
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
Configuration Diagram Server CHASSIS REAR
CHASSIS FRONT HDD Bay
HDD Bay
HDD Bay HDD Bay
HDD Bay
HDD Bay HDD Bay
HDD Bay
HDD Bay
HDD Bay HDD Bay
HDD Bay HDD Bay HDD Bay
HDD Bay
Backplane
CPU/IO Module
HDD Bay
Optical Drive Bay
CPU/IO Module
PCIe 2.0 x8 (x8 socket) FH
DIMM #8 DIMM #7 DIMM #6 DIMM #5 DIMM #9 DIMM #10 DIMM #11 DIMM #12
HDD Bay HDD Bay
PCI Riser
Cooling Fan #1 - #4
Processor
CHASSIS FRONT
HDD Bay
#1 #2 #3 #4
Drive Cage HDD Bay
DIMM DIMM DIMM DIMM
HDD Bay
CHASSIS REAR
HDD Bay
CPU/IO module #0 :
Power Supply
#16 #15 #14 #13
DIMM DIMM DIMM DIMM
#1 #2 #3 #4
HDD Bay
DIMM DIMM DIMM DIMM
HDD Bay
Processor PCIe 2.0 x4 (x8 socket) LP PCIe 2.0 x4 (x8 socket) LP
HDD Bay HDD Bay
HDD Bay HDD Bay
HDD Bay
Drive Cage
HDD Bay
PCIe 2.0 x8 (x8 socket) FH
DIMM #8 DIMM #7 DIMM #6 DIMM #5 DIMM #9 DIMM #10 DIMM #11 DIMM #12
HDD Bay
PCI Riser
Cooling Fan #1 - #4
Processor
HDD Bay
CPU/IO module #1 :
Processor PCIe 2.0 x4 (x8 socket) LP PCIe 2.0 x4 (x8 socket) LP
Power Supply
Legend:
NEC Corporation
DIMM DIMM DIMM DIMM
#16 #15 #14 #13
Minimum required components
Revision 4.0, April 2014
Standard components
8
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
Server Configuration 1 Base Models Product Name / Description
Part Number
EXPRESS5800/R320d-M4 no RAM, no 2.5-inch HDD Including: Intel Xeon Processor E5-2670 v2, 1 x DVD Super Multi, EXPRESSBUILDER DVD
N8800-185F
2 2nd Processor Available logical sockets: 1 Product Name / Description
Part Number
Intel® Xeon® Processor E5-2670 v2 2nd Processor Kit : 2.50 GHz / 10C-20T / 25 MB, 2 processors included
N8801-047
3 Memory Available logical slots: 8 per processor Product Name / Description
Part Number
4GB DDR3-1600 REG Memory Kit : 2 x 1 x 4GB DIMM included
N8802-060
32GB DDR3-1600 REG Memory Kit : 2 x 4 x 8GB DIMM included
N8802-061
64GB DDR3-1600 REG Memory Kit : 2 x 4 x 16GB DIMM included
N8802-062
NOTE:
Minimum one memory kit must be installed.
NEC Corporation
Revision 4.0, April 2014
9
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
Memory Configuration Guideline See the table below for the number of memory kits required in accordance with logical main memory size and number of logical processors. Memory configurations which are not listed below are not supported in the system.
Number of Logical Processors
1
Logical Main Memory Size
4GB
2
1
4GB
32GB
64GB
1
-
-
8GB
2
-
-
12GB
3
-
-
16GB
4
-
-
20GB
5
-
-
24GB
6
-
-
28GB
7
-
-
32GB
8
-
-
-
1
-
48GB
4
1
-
64GB
-
2
-
64GB
-
-
1
96GB
-
1
1
128GB
-
-
2
1
-
-
2
-
-
4GB
1
8GB
1
12GB
1
Number of Memory Kits Required
1
3
-
-
16GB
4
-
-
24GB
6
-
-
32GB
8
-
-
40GB
10
-
-
48GB
12
-
-
56GB
14
-
-
64GB
16
-
-
-
2
-
96GB
8
2
-
128GB
-
4
-
-
-
2
192GB
-
2
2
256GB
-
-
4
Interleave is not supported.
NEC Corporation
Revision 4.0, April 2014
10
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
4 Internal Hard Disk Drives Available bays: 8 Category
Product Name / Description
Part Number
SAS HDD
600GB 10K Hot Plug 2.5-inch SAS HDD : 1 x 600GB
N8850-047
900GB 10K Hot Plug 2.5-inch SAS HDD : 1 x 900GB
N8850-048
1.2TB 10K Hot Plug 2.5-inch SAS HDD : 1 x 1.2TB
N8850-051
146.5GB 15K Hot Plug 2.5-inch SAS HDD : 1 x 146.5GB
N8850-049
300GB 15K Hot Plug 2.5-inch SAS HDD : 1 x 300GB
N8850-050
200GB Hot Plug 2.5-inch SSD: 1 x 200GB
N8850-052
SAS SSD
NOTE: Hard drives must be installed in identical pairs to configure RAID 1.
Required System Disk Capacity See the table below for minimum required system disk capacity to store whole memory dump data. It is recommended to install hard drives providing the minimum required system disk capacity to reduce the time to resynchronize after a hard drive replacement. (For Microsoft® Windows Server® 2008 R2 Enterprise SP1) Memory Size Up to 28GB 32GB to 48GB 56GB to 64GB 96GB to 192GB 256GB
Required System Disk Capacity HDD
SSD
146.5GB 300GB
200GB Not supported
600GB 900GB
(For Microsoft® Windows Server® 2012 Standard / Datacenter) Memory Size Up to 24GB 28GB to 40GB 48GB to 64GB 96GB 128GB to 256GB
Required System Disk Capacity HDD
SSD
146.5GB 300GB
200GB Not supported
600GB 900GB
Notes for BTO with SSD The smallest capacity HDD/SSD is installed in the 1st HDD bay (as system disk) at factory.
If you use 200GB SSD as system disk and want to use 146.5GB HDD as data disk, order the 146.5GB HDD separately and install it later. When the operating system is Windows Server 2008 R2 and the memory size is 56GB or more, system disk capacity should be at least 300GB. In that case, BTO with SSD is not possible. If you want to use 200GB SSD as data disk in such a system, order the 200GB SSD separately and install it later. When the operating system is Windows Server 2012 and the memory size is 48GB or more, system disk capacity should be at least 300GB. In that case, BTO with SSD is not possible. If you want to use 200GB SSD as data disk in such a system, order the 200GB SSD separately and install it later.
NEC Corporation
Revision 4.0, April 2014
11
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
5 Optical Drive Available bays: 1 Product Name / Description
Part Number
Internal DVD Super Multi Drive : 1 x DVD Super Multi drive, not including writing software
(Standard)
6 PCI Card 6.1 LAN Controller Category
Product Name / Description
Part Number
LAN Controller
1000BASE-T 2ch board kit : 2 x GbE NIC Intel® Gigabit ET Dual Port Server Adapter 10GBASE-T 1ch Adapter Kit : 2 x 10GbE NIC Intel® X540-T1 NOTE: - Up to one controller per module - Installation in full height slots only supported on R320d-M4 - FCoE functionality is not supported
N8804-009 N8804-011
NOTE:
For iSCSI (data) connection, only 1000BASE-T ports (Including standard LAN ports) are supported.
6.2 Fibre Channel / SAS Controller Category
Product Name / Description
Part Number
Fibre Channel Controller
Fibre Channel board kit (8Gbps) : 2 x FC Controller QLogic QLE2560 8Gbps Fibre Channel Adapters NOTE: Installation in full height slots only supported on R320d-M4
N8803-038
SAS Controller
SAS Controller : 1 x SAS Controller LSI SAS9212-4i4e Host Bus Adapter NOTE: Up to one controller per module
N8803-039
NOTE:
For supported NEC Storage products to connect with N8803-038, contact your sales representative or refer to the NEC Storage WEB site. (http://www.nec.com/global/prod/storage/)
7 Other Add-in Components 7.1 Input Devices Category
Product Name / Description
Part Number
Keyboard
USB Keyboard
N8870-002AF
Mouse
USB Optical Wheel Mouse
N8870-012
Cable
USB cable : 1.5m USB extension cable
K410-177(1A)
NEC Corporation
Revision 4.0, April 2014
12
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
8 Add-on Components 8.1 17-inch LCD Console Drawer Category Drawer w/ KVM Switch
Drawer
Cable
Drawer w/o KVM Switch
Drawer
Keypad
Product Name / Description
Part Number
17inch LCD Console Unit (1U/8port) 17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM switch, 1U height 17-inch LCD Console Drawer (8port) 17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM switch, 1U height, black Switch Unit Connection Cable Set (USB, 1.8m) 1.8 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 3m) 3 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 5m) 5 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin USB A 17inch LCD Console Unit 1U 17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 4-pin USB B to 4-pin USB A cable 2m, PS/2 Y-splitter cable 2m, 15-pin mini D-sub VGA cable 2m 17inch LCD Console Unit 1U 17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m, 15-pin mini D-sub VGA cable 2 m, black 17inch LCD Console Drawer (1port) 17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8 m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m 17inch LCD Console Drawer (1port) 17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8 m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m, black Keyboard Unit (JP) JP 108-keys Keyboard with 10-key for N8143-84F 17inch LCD Console Drawer (1port) Keyboard Unit (UK) UK 104-keys Keyboard with 10-key, for N8143-84F 17inch LCD Console Drawer (1port) Keyboard Unit (JP) JP 108-keys Keyboard with 10-key for N8143-108F 17inch LCD Console Drawer (1port) Keyboard Unit (UK) UK 104-keys Keyboard with 10-key, for N8143-108F 17inch LCD Console Drawer (1port)
N8143-77F
N8143-106F
K410-118(1A)
K410-118(03)
K410-118(05)
N8143-76F
N8143-105F
N8143-84F
N8143-108F
N8143-85
N8143-87
N8143-109
N8143-111
8.2 KVM Switch Category
Product Name / Description
Part Number
KVM Switch
Server Switch Unit (8 server) 1U USB 8 port KVM switch Server Switch Unit (8 server) 1U USB 8 port KVM switch, black Switch Unit Connection Cable Set (USB,1.8m) 1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
N8191-12F
Cable
NEC Corporation
KVM
Revision 4.0, April 2014
N8191-14F K410-118(1A)
13
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
Cascading
Switch Unit Connection Cable Set (USB,3m) 3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable 1.8 m 1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2
K410-118(03)
K410-118(05)
K410-119(1A)
8.3 Flash FDD Order the Flash FDD if you need to prepare an alternative for a floppy drive. Product Name / Description
Part Number
Flash FDD USB flash emulating USB floppy disk, Native capacity 1.44 MB
N8160-96
8.4 Operating System Product Name / Description
Part Number
Microsoft Windows Server 2012 Standard (2CPU, 2VM) with Windows Server 2008 R2 downgrade rights, English For Windows Server 2008 R2 Enterprise installation
UL1045-001E
NOTE:
Please note that this product can only be sold to users upon their requests. Access the following website and agree to the terms and conditions for this product before ordering. http://www.nec.com/en/global/prod/express/fault_tolerant/w2012/downFT.html For Microsoft® Windows Server® 2012 Standard / Datacenter, there is no special license for FT servers. Please arrange it locally, or contact your sales representative for the availability of this operating system from NEC in your region.
8.5 Active UpgradeTM Product Name / Description
Part Number
Active Upgrade for ft NOTE: Supported on Microsoft® Windows Server® 2008 R2 Enterprise SP1 only
UL1535-001E
8.6 Tower Conversion Kit Product Name / Description
Part Number
Tower Conversion Kit 23 inch height pedestal with front bezel
N8843-004
NEC Corporation
Revision 4.0, April 2014
14
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
8.7 External Tape Drives 8.7.1 Tape Drive Selection Refer to the section in accordance with your type of tape drives. LTO
NEC Corporation
LTO3
SAS
Refer to 8.7.2
LTO4
SAS
Refer to8.7.2
LTO5
SAS
Refer to 8.7.2
LTO6
SAS
Refer to 8.7.2
Revision 4.0, April 2014
15
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
8.7.2 LTO / SAS Category
Product Name / Description
Part Number
Controller Required
N8803-039
External Cable Required
SAS Controller LSI SAS9212-4i4e Host Bus Adapter 6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8, LP/FH NOTE: Up to one controller per module External SAS cable 2 m, for Tape Drive Enclosure connection
Tape Enclosure Required
2U Tape Drive Enclosure 4 x 5-inch media bays, two internal SAS cables included, black
N8141-75F
Power Module Recommended
Power Supply 1 x non-hot plug power supply unit for redundant configuration
N8181-54F
Internal Cable
SAS Cable For 2U Tape Drive Enclosure internal connection NOTE: Required when three or more SAS connections (including other general purpose servers) to the N8141-75F
K410-335(00)
Drive 2 bays available
Internal LTO (SAS) LTO3, Half height, Native capacity 400GB, black Internal LTO (SAS) LTO4, Half height, Native capacity 800GB, black Internal LTO (SAS) LTO5, Half height, Native capacity 1500GB, black Internal LTO (SAS)
N8151-126
K410-191(02)
N8151-127 N8151-128 N8151-129
LTO6, Half height, Native capacity 2.5 TB, black
8.7.3 Notes for Double Backup In a single backup configuration, in case a CPU/IO module or backup device fails, backup is not possible until the failed part is repaired or replaced. If this does not meet your system requirements, consider a double backup configuration. Refer to the following notes on double backup configuration.
When configuring two sets of a SAS controller, a SAS cable and a backup device, two backup devices are recognized separately by the OS. When scheduling an automatic backup job, make a job for each backup device so that the other backup device can backup in case one device fails. With BrightStor ARCserve Backup, backup is not executed if you enter an asterisk (*) in the group box under the destination tab when defining a job. Be sure to create two backup jobs by correctly selecting the device group for the group box, and entering an asterisk (*) or the name of the media in the media box.
NEC Corporation
Revision 4.0, April 2014
16
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
8.7.4 Supported Backup Software See the table below for the supported backup software on NEC EXPRESS5800/R320d.
For Microsoft® Windows Server® 2008 R2 Enterprise SP1 Tape drive
Backup software ARCserve
Product Name / Description
Part Number
Backup Exec
ARCserve r16.5
Backup Exec 2012
Backup Exec 2014
WS2008R2
WS2008R2
WS2008R2
Internal LTO (SAS) LTO3, Native capacity 400 GB
N8151-102/126
*a1
*b1
*b1
Internal LTO (SAS) LTO4, Native capacity 800 GB
N8151-90/127
*a1
*b1
*b1
N8151-103/128
*a1
*b1
*b1
N8151-106/129
*a1
*b1
*b1
Internal LTO (SAS) LTO5, Native capacity 1.5 TB Internal LTO (SAS) LTO6, Native capacity 2.5 TB
*a1: Do not disable the tape driver on the device manager. *b1: Do not install the Symantec driver. Apply the driver which comes with the tape drive. NOTE:
Disaster Recovery Option is not supported on the ft server system. It is not supported to backup from NEC Express5800/ft series to a backup device directly using NetBackup. However, NEC Express5800/ft series can be a backup-client machine of NetBackup.
For Microsoft® Windows Server® 2012 Standard / Datacenter Tape drive
Backup software ARCserve
Product Name / Description
Part Number
Backup Exec
ARCserve r16.5
Backup Exec 2012
Backup Exec 2014
WS2012
WS2012
WS2012
Internal LTO (SAS) LTO3, Native capacity 400 GB
N8151-102/126
*a1
- *b1
Internal LTO (SAS) LTO4, Native capacity 800 GB
N8151-90/127
*a1
- *b1
N8151-103/128
*a1
- *b1
N8151-106/129
*a1
- *b1
Internal LTO (SAS) LTO5, Native capacity 1.5 TB Internal LTO (SAS) LTO6, Native capacity 2.5 TB
*a1: Do not disable the tape driver on the device manager. *b1: The BackupExec 2012 is not supported as media server on WS2012. NOTE:
Disaster Recovery Option is not supported on the ft server system. It is not supported to backup from NEC Express5800/ft series to a backup device directly using NetBackup. However, NEC Express5800/ft series can be a backup-client machine of NetBackup.
NEC Corporation
Revision 4.0, April 2014
17
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
References Server Management The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features listed in the table below.
Temperature/voltage/power/ fan /degeneration (memory/hard drive)
Hardware event log collection
Boot monitoring
Booting, BIOS/POST stall, OS stall, shutdown
Alerting
HW error, Boot error and OS panic (by SNMP, E-Mail)
Remote KVM
POST/BIOS setup, DOS utility
(via LAN)
Panic screen, Boot screen
Text-based screen (OS console)
GUI-based screen (OS console)
Remote control
Remote reset/power on-off/ dump
(via LAN)
OS shutdown
Remote media (CD/DVD/FD)
Server Management Command Line Protocol (DMTF compliant)
Remote control via Web browser (without dedicated app)
Remote batch
Scheduling (without UPS)
Others
Set automatic IP address via DNS/DHCP
Remote wakeup
Wake On LAN, Wake On Ring
Centralized management Industry standard
Monitoring and control of multiple servers
IPMI
2.0
Hardware monitoring
NEC Corporation
Revision 4.0, April 2014
18
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
Supported PCI Cards and Installable Slots Part Number
Slots
Notes
Slot # :
#1
#2
#3
#4
PCI Slot:
x4
x4
X8
X8
Card height:
LP
LP
FH
FH
Slot type:
x8
x8
x8
x8
N8804-009
1000BASE-T 2ch board kit
N8804-011
10GBASE-T 1ch board set
-
-
N8803-038 N8803-039 1
Product Name
Fibre Channel board kit
SAS board
1
1
Max. 1
1
1
1
1
Max. 1
Not installable when using Tower Conversion Kit.
NEC Corporation
Revision 4.0, April 2014
19
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
Notes for using Hyper-V Brief system interruption during synchronization process In the synchronization process of CPU modules, a memory copy is performed to duplex memory on both CPU modules. Most of the memory area can be copied without interrupting the system through the so-called brownout copy method, and just a small portion requires the system to stop. However, with Hyper-V, the system cannot use the brownout copy method. Therefore, the system does not respond for a longer period of time during the synchronization process of the CPU modules than without Hyper-V. See the table below for the reference values of interruption during re-synchronization of CPU/IO modules in a Hyper-V system. It is recommended that your system design take the interruption into account. Model / Memory Size
8GB
16GB
64GB
128GB
256GB
R320d-E4
2 sec
3 sec
10 sec
18 sec
36 sec
R320d-M4
2 sec
3 sec
8 sec
14 sec
27 sec
About Guest OS Guest operating systems supported on NEC Express5800/ft series are the same as other Express5800 Servers. The tables below show the supported guest OS.
For Windows Server 2008 R2 Hyper-V OS Windows Server 2012 (x64)
*1
Edition
SP
Standard / Datacenter
RTM
Windows Server 2008 R2 (x64)
Standard / Enterprise
RTM/SP1
Windows Server 2008 (x86/x64)
Standard / Enterprise
RTM/SP2
Windows Server 2003 R2 (x86/x64)
Standard / Enterprise
SP2
Windows Server 2003 (x86/x64)
Standard / Enterprise
SP2
Server / Advanced Server
SP4
Pro
RTM
Windows 7 (x86/x64)
Professional
RTM/SP1
Windows Vista (x86/x64)
Business
SP1/SP2
Windows XP (x64)
Professional
SP2
Professional
SP2/SP3
SUSE Linux Enterprise Server 10 (x86/x64)
-
SP3
Red Hat Enterprise Linux 5.2 - 5.5 (x86/x64)
-
-
Windows 2000
*2
Windows 8 (x86/x64)
Windows XP (x86)
*1
*2
*3
*1: KB2744129 must be applied on the host OS. *2: Microsoft support has already ended since July 13, 2010. *3: Must be installed with the sp4-applied media
NEC Corporation
Revision 4.0, April 2014
20
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
For Windows Server 2012 Hyper-V OS
Edition
SP
Windows Server 2012 R2 (x64)
Standard / Datacenter
RTM
Windows Server 2012 (x64)
Standard / Datacenter
RTM
Windows Server 2008 R2 (x64)
Standard / Enterprise
RTM/SP1
Windows Server 2008 (x86/x64)
Standard / Enterprise
SP2
Windows Server 2003 R2 (x86/x64)
Standard / Enterprise
SP2
Windows Server 2003 (x86/x64)
Standard / Enterprise
SP2
Windows 8 (x86/x64)
Pro
RTM
Windows 7 (x86/x64)
Professional
RTM/SP1
Windows Vista (x86/x64)
Business
SP2
Windows XP (x64)
Professional
SP2
Windows XP (x86)
Professional
SP3
Backup When using Hyper-V on a FT server, prepare a separate server for backup in the same way as for other general purpose servers with Hyper-V. For backup patterns, refer to each backup software company's web site.
NEC ESMPRO Agent For monitoring guest operating systems, NEC ESMPRO Agent for Guest OS is required. Contact your sales representative for this software.
Active Upgrade (For Windows Server 2008 R2 only) A team assigned to the virtual network by Hyper-V Virtual Network Manager cannot be used in Active Upgrade. To use Active Upgrade, at least one team that is not assigned to virtual network is required.
NEC Corporation
Revision 4.0, April 2014
21
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less.
NEC Corporation
Revision 4.0, April 2014
22
CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server model
Revision History Revision
Date
Description
4.0
2015.4.28
New products added: 17-inch LCD Console Drawer (8port) N8143-106F 17inch LCD Console Unit 1U N8143-105F 17inch LCD Console Drawer (1port) N8143-108F Keyboard Unit (JP) N8143-109 Keyboard Unit (UK) N8143-111 Server Switch Unit (8 server) N8191-14F Flash FDD N8160-96 2U Tape Drive Enclosure N8141-75F SAS cable K410-335(00) Internal LTO (SAS) N8151-126/ N8151-127/ N8151-128/ N8151-129 Discontinued products removed: Flash FDD N8160-86 2U Tape Drive Enclosure N8141-59F Internal SAS cable K410-249(00) Internal LTO (SAS) N8151-102/ N8151-90/ N8151-103/ N8151-106
3.0
2014.12.2
New products added: WS2012 Standard with WS2008R2 downgrade right UL1045-001E Discontinued products removed: WS2008R2 Enterprise English UL0999-436EN WS2008R2 Enterprise Chinese Traditional UL0999-436CT WS2008R2 Enterprise Chinese Simplified UL0999-436CS WS2008R2 Enterprise Korean UL0999-436KR Others: Required System Disk Capacity updated Supported Backup Software information updated
2.0
2014.6.16
New products added: 200GB Hot Plug 2.5-inch SSD N8850-052 Others: Windows Server 2012 supported
1.0
2014.3.18
Initial release
NEC Corporation
Revision 4.0, April 2014
23