Transcript
Water Disinfection across the Globe
Chemicalfree Water Treatment
NECON GmbH
NECON GmbH — A company combining expertise with responsibility Founded in 1981 by Dr.-Ing. Klaus Gebhardt as an engineering company for automation technology and metal design, NECON GmbH is today a leading supplier worldwide in the area of chemical-free water disinfection and innovative swimming pool equipment. Dedicated to providing a safe, ecofriendly and cost-effective alternative to chemical water treatment, NECON GmbH has conducted intensive research for many years, in cooperation with renowned scientists and laboratories. With the „NECON System“, a centuries-old principle of electrophysical water treatment has been finally redefined, engineered to production-maturity and patented. NECON GmbH offers both private and public pool operators a broad range of products for numerous applications, including whirlpools, compact water tanks and swimming pools up to Olympic-size facilities.
-2-
NECON
C he m icalf r e e Wate r Tr e atment
Made in
Germany
TABLE OF CONTENTS
TABLE OF CONTENTS Functional Principle
Page 4-5
Comparison Chlorine / Ionisation
Page 6
Certificates / Laboratory Tests
Page 7
Representations / References
Page 8-11
Projects
Page 12-13
Legionella Treatment
Page 14
Water Treatment Systems
B21010, B21011, B21012
Page 15
Measuring and Control Technology
A1000, A2000, A7000, A8000
Page 16-27
Komplett-Technik
D1000, D7000
Page 28-31
N E C ON
C h e m i c a l f r e e Wate r Tr e atm e nt
M ade in
Germany
-3-
FUNCTIONAL PRINCIPLE
Due to intensive cooperation with renowned scientists and laboratories, NECON have successfully redefined the centuries-old principle of electrophysical water treatment. Every effort has been made to meet the specification of 100% chemical-free operation. With the use of innovative electrode materials and configurations, we have been able to overcome the problems of the fluctuation of pH values and the related for mation of limescale. Analytical data sampled from NECON GmbH projects in the public swimming pool sector worldwide attest best possible water quality. The NECON system consists of a state-of-the-art microprocessor-controlled electronic unit and the patented disinfection electrodes.
Within just fractions of a second, the positively charged copper and silver ions form electrostatic bonds with the negatively charged areas of the cell walls of the microorganisms. This process alters the permeability of their cell walls to such an extent that the normal nutrient intake of the microorganisms is impaired. Once copper and silver penetrate an algae or germ cell, they attack the sulphur-based amino acids in the cell proteins required by the cell for photosynthesis. As a result, the cells dies. For this reason, electrophysical water disinfection is one of the most common alternatives to the conventional „chemical warfare“.
-4-
NECON
C he m icalf r e e Wate r Tr e atment
Made in
Germany
FUNCTIONAL PRINCIPLE
Other advantages are that it provides natural, odourless, soft and skin-friendly water which is ideal for children and in health care. Silver has already been known for centuries to destroy bacteria and viruses, even those which are resistant to chlorine. Silver sulphate is frequently used in the antibacterial treatment of burns and open wounds and even protects newborns against infection. Copper as a trace element plays a vital role in human metabolism. Copper is essential to the activity of many proteins and enzymes. It promotes the formation of skin pigments and has important functions in bone metabolism and in the central nervous system. As the body is not itself capable of producing copper, it must obtain copper from nutrients (such as vegetables, wholemeal bread, nuts and oats), while copper intake through liquids is generally low.
The levels of copper required for swimming pool disinfection and prevention of algae vary between 0.5 and 0.7 mg/l. For comparison: While the German DIN standards for treatment of swimming pool water do not regulate this aspect at all, the country‘s rigid drinking water regulations decree a maximum copper concentration of 2 mg/l. Any surplus copper ions ingested by adults will be excreted. The most important advantage of copper and silver ions is that they persist in the water, providing complete protection by purifying the water without the use of any toxins over a lengthy period of time. Even after the filter system has been switched off, this depot effect lasts for several months. Thus, there is no need for repetitive monitoring and readjustments requiring attendance. The NECON water treatment system is straightforward to operate and requires only minimal maintenance. It has been demonstrated that copper and silver ions eliminate Cryptosporidium, E. coli, coliforms, Pseudomonas and legionellae as well as many other species of bacteria and germs. This water disinfection technique can be used in practically all situations where lasting disinfection of bacteria, viruses and algae is required. It is already employed in thousands of swimming pools and whirlpools.
N E C ON
C h e m i c a l f r e e Wate r Tr e atm e nt
M ade in
NECON systems are supplied for public as well as private sector swimming pools with sizes of up to 3000 m³. NECON is represented by international distributors in the following countries: China, Dominican Republic, Greece, Great Britain, India, Italy, Mallorca, Northern Cyprus, Kazakhstan, Kyrgyzstan, Russia, Rumania, Saudi Arabia, Spain, Taiwan, Thailand, Turkey, Ukraine and Uzbekistan.
Germany
-5-
COMPARISON CHLORINE / IONISATION Comparison with the standard water disinfection method Chlorine
-6-
Copper/Silver
1. Causes reddened, irritated eyes
1. No eye irritation
Average copper levels in food
2. Causes dry, rough skin
2. Silky-soft skin
3. Marked odour, particularly in indoor facilities
3. Odourless water
NECON-disinfected water: 0.5 – 0.7 mg/l
4. Potential irritation of respiratory tracts
4. Water contains no irritants
5. Chlorine is hazardous
5. Copper is healthy (essential element)
6. Requires application of flocculators
6. Natural flocculation
7. Requires additional agents during winter breaks
7. No additional agents required during winter breaks
8. Requires additional application of algaecides
8. No additional algaecidal agents required
9. Requires storage and frequent replenishment
9. No storage required
cow milk beef pork venison codfish poultry eggs white bread rye bread oat flakes rice potatoes cabbage dried vegetables nuts apples and pears banana
10. Requires weekly chlorine-level checks
10. Copper-level check every three months
11. Risk of chemical burns from liquid chlorine
11. Fully automatic and safe discharge of ions
12. Requires additional agents to regulate pH level
12. No additional agents required to regulate pH level
13. Corrosion risk for pool materials and environment
13. No corrosive effects
14. Low buffer capacity
14. Constant discharge of ions
15. Annual replacement of chlorinated water
15. Replacement of water not required
16. Replacement of filter sand every 2–3 years
16. Replacement of filter sand every 10 years
17. Rapid loss of efficacy if exposed to strong sunlight
17. Efficacy not affected by environmental conditions
18. Backwash water must be disposed
18. Backwash water ideally suited for irrigation of plants
NECON
C he m icalf r e e Wate r Tr e atment
Made in
0.4 mg/kg 0.9 mg/kg 2.0 mg/kg 2.1 mg/kg 5.5 mg/kg 3.4 mg/kg 2.5 mg/kg 2.0 mg/kg 3.5 mg/kg 8.8 mg/kg 1.8 mg/kg 2.2 mg/kg 1.5 mg/kg 9.0 mg/kg 5.0 mg/kg 0.9 mg/kg 1.3 mg/kg
Germany
CERTIFICATES / LABORATORY TESTS
N E C ON
C h e m i c a l f r e e Wate r Tr e atm e nt
M ade in
Germany
-7-
REPRESENTATIONS
NECON GmbH HEADQUARTERS D-79312 Emmendingen
NECON’s worldwide activities include the following countries: China, Dominican Republic, Greece, Great Britain, India, Italy, Kazakhstan, Kyrgyzstan, Uzebekistan, Mallorca, Northern Cyprus, Rumania, Russia, Saudi Arabia, Spain, Taiwan, Thailand, Turkey, Ukraine and United Arab Emirates.
-8-
NECON
C he m icalf r e e Wate r Tr e atment
Made in
Germany
REPRESENTATIONS NECON RUSSIA Company KIT-SV ul. Geroev Panfilovtsev 10, office 806-807 125363 Moskau Russia Tel. 007-495-225 50 50 www.necon.ru NECON UKRAINE Company UVENTA-Group Ul. Stezenko 55 04128 Kiev Ukraine Tel. 0038-044-22 30 101 www.necon.com.ua
[email protected] NECON MIDDLE ASIA Company MASTERPOOL ul. Satpaewa 90, office 506 050046 Almaty Kasakhstan Tel. 007-3272-601 133 Mobil 007-3332169296 www.masterpool.kz NECON EGYPT & MIDDLE EAST Hurghada - Dahar / El Kyadat Vicinity of Cinderella Hotel Tel. 0020-16-892 70 55
[email protected]
N E C ON
C h e m i c a l f r e e Wate r Tr e atm e nt
M ade in
Germany
-9-
REFERENCES
- 10 -
Dr. A. Riggenbach Engelgasse 102 CH- Basel Tel. +41 (0)61- 741 16 19
Martin Schmieder Geroldsecker Vorstadt 127 D- 77933 Lahr Tel. +49 (0)7821- 771 10
Peter Baral Lise-Meitner-Strasse 1 D- 79211 Denzlingen Tel. +49 (0)7666 - 91 03 33
Thomas Michel Ottostrasse 4 D- 82319 Starnberg Tel. +49 (0)8151- 890 91
Dr. Schulte-Vallentin Hans-Thoma-Strasse 9 D- 79110 Freiburg Tel. +49 (0)761- 726 81
Wolfgang Windecker Edelhalde 45 D- 72285 Pfalzgrafenweiler Tel. +49 (0)7445 - 13 16
Ludwig Heß Lossenweg 8 D- 64285 Darmstadt Tel. +49 (0)6151- 6 10 05
Christian Wangart Wiesentalstrasse D- 79110 Freiburg Tel. +49 (0)761- 45 90 30
Harald Erichsen Spemannplatz 1 D- 79100 Freiburg Tel. +49 (0)761 - 40 35 17
Dr. J. Nitsch Herrgasse 21 D- 79294 Sölden Tel. +49 (0)761- 40 20 77
Dr. Gauer Am Eselsberg 14 D- 97318 Kitzingen Tel. +49 (0)9321- 79 74
Klaus-J. Hilgers Waldweg 46 D- 52525 Heinsberg Tel. +49 (0)2455 - 93 99 30
Walter Riekert Wildtalstrasse D- 79194 Gundelfingen Tel. +49 (0)761- 59 20 30
Jürgen Schulz Untere Gewerbestrasse 16 D- 77791 Berghaupten Tel. +49 (0)7803 - 96 96 0
Hotel „Heimliche Liebe“ Herr Zöller Baldeney 33 D- 45134 Essen Tel. +49 (0)201- 43 52 00
Sigrid Rohwedder Baumschulweg 70 D- 55276 Oppenheim Tel. +49 (0)6133 - 92 53 20
Wolfgang Frömsdorf Salzstrasse 11 D- 87776 Memmingen Tel. +49 (0)8331- 44 11
Additional reference contacts on request
NECON
C he m icalf r e e Wate r Tr e atment
Made in
Germany
REFERENCES
N E C ON
C h e m i c a l f r e e Wate r Tr e atm e nt
M ade in
Germany
- 11 -
PROJECTS
- 12 -
Olympic Games 2004 in Athens Pentathlon pool in Goudi
Plant room for pentathlon pool 3000m³
Four NEC 4001.8 systems mounted in bypass assembly, Athens, 2004
Olympic Games 2004 in Athens Pentathlon pool in Goudi
National Sports Training Center Taiwan
50m long course swimming pool with 10 starting blocks 3000m³
50m long course swimming pool with 10 starting blocks 3000 m³, Taiwan
High diving pool at the Athletic Sports Center, equipped with NEC 4002.8, Taiwan
Plant room, Taiwan
Installation for long course pool, Taiwan
NEC 4002.8 mounted in bypass assembly for pool sizes up to 3000m³, Taiwan
High diving pool at the Athletic Sports Center, Taiwan
NECON
C he m icalf r e e Wate r Tr e atment
Made in
Germany
PROJECTS
Welcoming His Majesty at the exhibition booth in Abu Dhabi, UAE
Dubai hotel facility, 2006
Dubai hotel facility, 2006
Dubai hotel facility, 2006
Private facility, Dominican Republic
Aquafun Park, Dominican Republic
N E C ON
Private pool, Corsica
C h e m i c a l f r e e Wate r Tr e atm e nt
Trick fountains Europa Park Rust, Germany
M ade in
Private pool Freiburg, Germany
Germany
- 13 -
LEGIONELLA TREATMENT
Legionnaires’ disease The term Legionnaires‘ disease (Legionellosis) derives from an outbreak of pneumonia at the 1976 American Legion Convention in Philadelphia. Subsequently, the previously unknown causative bacterium was named Legionella. Without proper treatment, the disease may have mortal consequences especially for the elderly and people with immunodeficiencies. Natural habitat of Legionalla bacteria Legionella bacteria thrive primarily in warm water with temperatures between 30°C and 45°C (86–113°F). Hot water supplies are probably the most prolific of everyday sources of Legionalla and constitute a potentially serious health hazard especially in public facilities such as in hotels, swimming pools, school buildings, hospitals and retirement homes. Infection paths Legionalla are transmitted via aerosols, and may reach the lung system by inhalation or aspiration of mist droplets containing the bacteria. Infection sources include installations and devices like showers and whirlpools, air conditioners and air dampers or inhalators, but also facilities like cooling towers or greenhouses with overhead sprinkling. PREVENTIVE MEASURES The application of copper and silver ions is regarded as the most effective means of disinfection since it provides long-lasting protection. During employment in hospitals it proved to be nonpolluting and safe to use. Furthermore this methode is cost-efficient due to its straightforward usage and since piping systems will not become affected by corrosion.
- 14 -
NECON
Study excerpt
Corrosive Toxic damage to pipes
Tempera- pH-sen- Scale High Easy recolo- Resituresitive build-up energy nization after dual sensitive consump- treatment effect tion
Easy application
Thermal shock
yes
no
yes
yes
yes
yes
yes
no
no
Not suitable for big facilities Scalding dangerous
Constant maintenance of high temperature
yes
no
no
yes
yes
yes
yes
no
no
Not suitable for big facilities Scalding dangerous
Periodic chlorination
yes
yes
yes
yes
yes
no
yes
no
no
Handling precautions effluent restrictions
Shock hyperchlorination
yes
yes
yes
yes
yes
no
yes
no
no
Handling precautions effluent restrictions
Continuous chlorination
yes
yes
yes
yes
yes
no
yes
yes
no
Handling precautions effluent restrictions
Chlorine dioxide
yes
yes
yes
yes
yes
no
yes
yes
no
Handling precautions esp. as to explosion risk
Monochloramine
yes
yes
yes
yes
yes
no
yes
yes
no
Handling precautions under research
Ionisation
no
no
no
no
no
no
no
yes
yes
Very efficient including long term protection after treatment
Hydrogen peroxide + silver
no
yes
yes
yes
no
no
yes
yes
no
Further experimental validation required
Ultraviolet light
no
no
no
yes
no
yes
yes
no
yes
Insufficient as sole method due to lack of residual protection
C he m icalf r e e Wate r Tr e atment
Made in
Germany
MEASURING AND CONTROL TECHNOLOGY
Measurement system copper
No. B21012
Colour comparison test kit for copper level analysis, in set case.
Measurement system copper
No. B21010
Photometric test kit for copper level analysis, set case including digital display.
Measurement system silver
No. B21011
Colour comparison test kit for silver level analysis, in set case.
N E C ON
C h e m i c a l f r e e Wate r Tr e atm e nt
M ade in
Germany
- 15 -
WATER TREATMENT SYSTEMS
Water Treatment System Patented solution for antibacterial and algicidal filling of water tanks in caravans, on sailing and motor yachts, in camping and outdoor, as well as in holiday apartments, etc. 100% elimination of all germs and bacteria (esp. of E.coli, pseudomonads, and legionellae), as well as of algae, by means of ionisation. Thorough and long-lasting depot effect keeps water and tank clean, regardless of outside temperatures or exposure to sunlight. This means fresh-tasting, hygienic water for months – 100% chemical-free. Without the pain of regular tank cleaning. At considerably lower costs than comparable water treatment methods. Easy to utilize, flexible connectivity.
Technical Data: Electrode dimensioned for treating 50.000 liters water; system ships including 2 electrodes (1 built-in, 1 reserve) Connection threads: ¾ inch. Flow rate ca. 1m³/hour assuming conventional line pressure (2-3 bar) Processor-controlled max./min. current limiting to ensure ionisation operation 3 LEDs indicate operating status (green = ready, yellow = ionisation, red = failure) Monitoring of input voltage to prevent deep discharge of the external power source (battery) Dimensions: L = 345mm (430mm with flow monitor attached), H = 150mm, W = 40mm; fitting position freely adaptable Weight approx. 1kg, plus 1kg battery
- 16 -
NECON
C he m icalf r e e Wate r Tr e atment
Made in
Germany
WATER TREATMENT SYSTEMS
Water Treatment System
.1 A2000.1 + C21000
Due to its low weight and flexible connectivity, the device is ideally suited for mobile operation when traveling, but also when filling storage water tanks for example in campmobiles, on boats, or cisterns. Besides 2 electrodes, the system ships with 2 hose plug-in adaptors, 1 connector for 12V car battery, 1 line adaptor 110/230V – 12V 1000mA, complete in set case.
Water Treatment System
.2 A2000.2 + C21000
For fixed installation such as in campmobiles and boats, or intergration with the water treatment equipment of above-ground and whirl pools. Utilizing an integrated flow monitor, ionisation is automated to be active only as long as water is actually flowing, in systems with closed water intake piping.
N E C ON
C h e m i c a l f r e e Wate r Tr e atm e nt
M ade in
Germany
- 17 -
WATER TREATMENT SYSTEMS
Water Treatment System NEC-1000
No. B1000 NEC - 1000
The new “SCS – Self Cleaning System” prevents lime build-up on the electrodes. Concurrent with the SCS system, a new front panel has been designed that shows operating procedures clearly arranged on a touch-activated plastic foil control surface. The easy-to-read display shows the following items: time of day, disinfecting electrodes (Cu/Ag) with their polarisation, and operation status of the filter pump.
Technical data of control unit: 1. Operating voltage 230V 50/60 Hz 3 Amps 2. Operating power of the electrode treatment cell max. 15 Amps 3. Dimensions (W x H x D): 300 x 260 x 120 mm 4. Water conductivity 500 up to 2000 µS 5. Switching capacity of pump max. 1,1 kW 6. Protection class IP 54
- 18 -
NECON
C he m icalf r e e Wate r Tr e atment
Made in
Germany
WATER TREATMENT SYSTEMS
Water Treatment System NEC-1000.1
No. A1000.1 + C21031
For private indoor swimming pools up to 40 m³ For private open-air swimming pool up to 30 m³ Unfit for public swimming pools
Water Treatment System NEC-1000.2
No. A1000.2 + C21035
For private swimming pools up to 80 m³ For public swimming pools up to 50 m³
Water Treatment System NEC-1000.4
No. A1000.4 + C21039
For private swimming pools up to 160 m³ For public swimming pools up to 100 m³
N E C ON
C h e m i c a l f r e e Wate r Tr e atm e nt
M ade in
Germany
- 19 -
WATER TREATMENT SYSTEMS
Water Treatment System NEC-1000.5
No. A1000.5 + C21039 x 2
For private swimming pools up to 320 m³ For public swimming pools up to 250 m³
Water Treatment System NEC-1000.6
No. A1000.6 + custom electrode
For water disinfection, algae control as well as for treatment of calcareous water, esp. in situations involving high water pressures like in cooling towers and industry, gardening, etc. Adaption to varied applications by specific configuration of the electrode package.
- 20 -
NECON
C he m icalf r e e Wate r Tr e atment
Made in
Germany
WATER TREATMENT SYSTEMS
Water Treatment System NEC-7000
No. B7000 NEC - 7000
The new “SCS – Self Cleaning System” prevents lime build-up on the electrodes. Concurrent with the SCS system, a new front panel has been designed that shows operating procedures clearly arranged on a touch-activated plastic foil control surface. The easy-to-read display shows the following items: time of day, water temperature (adjustable), disinfecting electrodes (Cu/Ag) with their polarisation, and operation status of the filter pump.
Technical data of control unit: 1. Operating voltage 230V 50/60 Hz 3 Amps 2. Operating power of the electrode treatment cell max. 15 Amps 3. Dimensions (W x H x D): 300 x 260 x 120 mm 4. Water conductivity 500 up to 2000 µS 5. Switching capacity of pump max. 1,1 kW 6. Temperature control max. 40 °C 7. Protection class IP 54
N E C ON
C h e m i c a l f r e e Wate r Tr e atm e nt
M ade in
Germany
- 21 -
WATER TREATMENT SYSTEMS
Water Treatment System NEC-7000.1
No. A7000.1 + C21031
For private indoor swimming pools up to 40 m³ For private open-air swimming pools up to 30 m³ Unfit for public swimming pools
Water Treatment System NEC-7000.2
No. A7000.2 + C21035
For private swimming pools up to 80 m³ For public swimming pools up to 50 m³
- 22 -
NECON
C he m icalf r e e Wate r Tr e atment
Made in
Germany
WATER TREATMENT SYSTEMS
Water Treatment System NEC-7000.4
No. A7000.4 + C21039
For private swimming pools up to 160 m³ For public swimming pools up to 100 m³
Water Treatment System NEC-7000.5
No. A7000.5 + C21039 x 2
For private swimming pools up to 320 m³ For public swimming pools up to 250 m³
N E C ON
C h e m i c a l f r e e Wate r Tr e atm e nt
M ade in
Germany
- 23 -
WATER TREATMENT SYSTEMS
Water Treatment System NEC-8000
No. B8000 NEC - 8000
The new “SCS – Self Cleaning System” prevents lime build-up on the electrodes. Concurrent with the SCS system, a new front panel has been designed that shows operating procedures clearly arranged on a touch-activated plastic foil control surface. The easy-to-read display shows the following items: time of day, disinfecting electrodes (Cu/Ag) with their polarisation, and operation status of the filter pump. Technical data of control unit: 1. Operating voltage 230V 50/60 Hz 4 Amps 2. Operating power per electrode treatment cell max. 10 Amps 3. Dimensions (W x H x D): 500 x 500 x 210 mm 4. Water conductivity 500 up to 2000 µS 5. Protection class IP 54
- 24 -
NECON
C he m icalf r e e Wate r Tr e atment
Made in
Germany
WATER TREATMENT SYSTEMS
NEC-8000.4 for swimming pools up to 500 m³
No. A8000.4 + C21035 x 4
Compact water treatment plant, completely preassembled on an aluminium rack, including piping and 4 Maxi-Combi (Cu/Ag) treatment cells that are electrically wired. Bypass mounting of system recommended in order to ensure maintenance and servicing without interrupting water flow. Including measurement systems for copper and silver analysis. Standard fitting = ø 110 mm Dimensions: (L x W x H) 1000 x 600 x 1700 mm Weight – 140 kg
NEC-8000.5 for swimming pools up to 650 m³
No. A8000.5 + C21035 x 5
Compact water treatment plant, completely preassembled on an aluminium rack, including piping and 5 Maxi-Combi (Cu/Ag) treatment cells that are electrically wired. Bypass mounting of system recommended in order to ensure maintenance and servicing without interrupting water flow. Including measurement systems for copper and silver analysis. Standard fitting = ø 110 mm Dimensions: (L x W x H) 1500 x 600 x 1700 mm Weight – 150 kg
N E C ON
C h e m i c a l f r e e Wate r Tr e atm e nt
M ade in
Germany
- 25 -
WATER TREATMENT SYSTEMS
NEC-8000.8 for swimming pools up to 800 m³
No. A8000.8 + C21035 x 8
For system description refer to 8000.4, except that 8000.8 includes 8 Maxi-Combi (Cu/Ag) treatment cells. Bypass mounting of system recommended in order to ensure maintenance and servicing without interrupting water flow. Including measurement systems for copper and silver analysis. Standard fitting = ø 110 mm Dimensions: (L x W x H) 1000 x 600 x 1700 mm Weight – 180 kg
NEC-8000.10 for swimming pools up to 1500 m³
No. A8000.10 + C21035 x 10
For system description refer to 8000.4, except that 8000.10 includes 10 Maxi-Combi (Cu/Ag) treatment cells. Bypass mounting of system recommended in order to ensure maintenance and servicing without interrupting water flow. Including measurement systems for copper and silver analysis. Standard fitting = ø 110 mm Dimensions: (L x W x H) 1500 x 600 x 1700 mm Weight – 200 kg
- 26 -
NECON
C he m icalf r e e Wate r Tr e atment
Made in
Germany
WATER TREATMENT SYSTEMS
NEC-8001.8 for swimming pools up to 2500 m³
No. A8001.8 + C21039 x 8
For system description refer to 8000.4, except that 8001.8 includes 8 DoubleSize-Combi (Cu/Ag) treatment cells. Bypass mounting of system recommended in order to ensure maintenance and servicing without interrupting water flow. Including measurement systems for copper and silver analysis. Standard fitting = ø 110 mm Dimensions: (L x W x H) 1000 x 600 x 1700 mm Weight – 300 kg
NEC-8001.10 for swimming pools up to 3000 m³
No. A8001.10 + C21039 x 10
For system description refer to 8000.4, except that 8001.10 includes 10 DoubleSize-Combi (Cu/Ag) treatment cells. Bypass mounting of system recommended in order to ensure maintenance and servicing without interrupting water flow. Including measurement systems for copper and silver analysis. Standard fitting = ø 110 mm Dimensions: (L x W x H) 1500 x 600 x 1700 mm Weight – 360 kg
N E C ON
C h e m i c a l f r e e Wate r Tr e atm e nt
M ade in
Germany
- 27 -
KOMPLETT-TECHNIK
Water Treatment System NEC-1000-Komplett-Technik
No. D1000 NEC - 1000
The new “SCS – Self Cleaning System” prevents lime build-up on the electrodes. Consisting of: water treatment system NEC-1000 incl. treatment cell for the Combi (Cu/Ag) electrode, filter motor incl. pre-filter, sand filter (supply of filtration material like NECLEAR optional), and mechanical back wash system. Completely preassembled and wired on a zinc-coated adjustable palette. Including measurement system for copper analysis. Dimensions: (L x W x H) 1000 x 1000 x 1650–2000 mm Weight excluding filtration material – 110 kg
NEC-1000.1-Komplett-Technik
No. D1000.1 + C21031
For private indoor swimming pools up to 40 m³ For private open-air swimming pools up to 30 m³ Unfit for public swimming pools
NEC-1000.2-Komplett-Technik
No. D1000.2 + C21035
For private swimming pools up to 80 m³ For public swimming pools up to 30 m³
- 28 -
NECON
C he m icalf r e e Wate r Tr e atment
Made in
Germany
KOMPLETT-TECHNIK
NEC-1000.4-Komplett-Technik
No. D1000.4 + C21039
For private swimming pools up to 160 m³ For public swimming pools up to 50 m³
Available against extra charge in combination with the following items: Automatic Backwash
No. B21054
For quick installation on the 6-way plastic valve 1 ½ ” and for combination with the filter control, 230 V, ø 50 mm
Noiseless Filter Pump
No. B21049 No. B21051
Silent-running motor. Pump housing made of fibre glassreinforced polypropylene, extra large pre-filter. 0.75 kW, 230 V suitable for models: D1000.1, D1000.2 0.95 kW, 230 V suitable for models: D1000.4
N E C ON
C h e m i c a l f r e e Wate r Tr e atm e nt
M ade in
Germany
- 29 -
KOMPLETT-TECHNIK
Water Treatment System NEC-7000-Komplett-Technik
No. D7000 NEC - 7000
The new “SCS – Self Cleaning System” prevents lime build-up on the electrodes. Consisting of: water treatment system NEC-7000 incl. treatment cell for the Combi (Cu/Ag) electrode, filter motor incl. pre-filter, sand filter (supply of filtration material like NECLEAR optional), and mechanical back wash system. Completely preassembled and wired on a zinc-coated adjustable palette. Including measurement system for copper analysis. Dimensions: (L x W x H) 1000 x 1000 x 1650–2000 mm Weight excluding filtration material – 110 kg
NEC-7000.1-Komplett-Technik
No. D7000.1 + C21031
For private indoor swimming pools up to 40 m³ For private open-air swimming pools up to 30 m³ Unfit for public swimming pools
NEC-7000.2-Komplett-Technik
No. D7000.2 + C21035
For private swimming pools up to 80 m³ For public swimming pools up to 30 m³
- 30 -
NECON
C he m icalf r e e Wate r Tr e atment
Made in
Germany
KOMPLETT-TECHNIK
NEC-7000.4-Komplett-Technik
No. D7000.4 + C21039
For private swimming pools up to 160 m³ For public swimming pools up to 50 m³
Available against extra charge in combination with the following items: Automatic Backwash
No. B21054
For quick installation on the 6-way plastic valve 1 ½ ” and for combination with the filter control, 230 V, ø 50 mm
Noiseless Filter Pump Silent-running motor. Pump housing made of fibre glassreinforced polypropylene, extra large pre-filter.
No. B21049 No. B21051
0.75 kW, 230 V suitable for models: D7000.1, D7000.2 0.95 kW, 230 V suitable for model: D7000.4
Heat Exchanger incl. Heating Pump Compact heating block made of polished stainless steel with connection for central heating. Complete with plastic mounting, heating pump and back flow stop valve as well as temperature sensor.
No. B21081 No. B21083
Power — 40 kW suitable for models: D7000.1, D7000.2 Power — 70 kW suitable for model: D7000.4
N E C ON
C h e m i c a l f r e e Wate r Tr e atm e nt
M ade in
Germany
- 31 -
Chemicalfree Water Treatment M ade in
NECON GmbH Elzstrasse 26 D- 79312 Emmendingen Fon +49 (0) 7641 / 91 23 40 Fax +49 (0) 7641 / 91 23 45 Internet: www.necon.de e-Mail:
[email protected]
Ge r m any
Presented with compliments by: