ADINSTRUMENTS MLT1406 Needle Microprobe Thermocouple Transducer Series Description The MLT1406 Needle Microprobe Thermocouple is a fast-response needle probe for instant temperature readings in tissue, semisolids and liquids. The probe consists of a 29 gauge, 1cm long needle. The needle tip is sealed to ensure only the stainless steel is in contact with the specimen. The MLT1406 is supplied with a 2-pin T-type thermocouple plug suitable for connection to the ML312 T-type Pod or ML290-V Thermometer for T-type thermocouples. Operation A copper-constantan sensor within the stainless steel shaft measures the temperature. The two dissimilar metals are joined at a junction which produces a small thermoelectric voltage when heated. This voltage is proportional to temperature. Application The MLT1406 Needle Microprobe Thermocouple is suitable for temperature measurements below 200 °C. Probe Diagram 1cm Caution Read “Statement of Intended Use” on our website or in “Getting Started with PowerLab” before use. • Intended for animal use only. • Do not autoclave. • To clean, wipe probe with alcohol or use a liquid sterilization medium such as Cidex (applied with a sterile wipe.) Specifications Operating range: Sensor element: Accuracy: Thermal response time: Probe type: Shaft length: Shaft size: Cable length: Connector: –273 to 200 °C Type T Thermocouple ±0.1 °C 0.125 seconds Non-isolated 10 mm (0.39") 29 gauge 1.5 m (5') T-type All specifications were tested at the time of printing and are subject to change. Ordering Information: MLT1406 Needle Microprobe Thermocouple For use with: ML312 T-type Pod ML290-V Thermometer for T-type thermocouples ADINSTRUMENTS.com ISO 9001:2008 Certified Quality Management System WARRANTY: ADInstruments PowerLab data acquisition units (Product Number Prefix: PL), Front-end Signal Conditioners (Product Number Prefix: FE) are warranted against defects in materials and workmanship for a period of 5 years from the date of purchase. Other PowerLab data acquisition units and ADInstruments manufactured Front-end and Pod Signal Conditioners, and Instruments are warranted of a period of 3 years from the date of purchase. Third party products are covered by the manufacturer’s warranty. Warranties are void if the product has been damaged due to negligence. Consumables and electrodes are not covered by a warranty. All questions regarding service and warranty should be directed to your nearest ADInstruments representative. MLT1406-DCW-15A