INSTALLATION NOTES MODEL: Quantum SONIC PIR PART NUMBER: 100-022 FEATURES • Passive Infra-Red motion sensor • Dual purpose PIR and SIREN • 15m x 15m wide angle coverage • Selectable High/Low range • Selectable Pulse Count • Vertical "Creep" coverage • High R.F. and E.S.D. immunity • High white light immunity • Low current draw • 9–15V DC operation • Loud 108dB Piezo screamer built-in Installation and setup notes. Revision 1 MOUNTING LOCATION INSTALLATION & TESTING This Passive Infra Red detector, (PIR), is designed for indoor use only and can be installed in wall or corner mount locations. 1 Open the detector’s front housing by unclipping the bottom of the lid and swing it open and away from the back housing. Always ensure the detector has a clear line of sight of the area to be protected as infra-red energy does not pass through solid objects, (including glass). 2 Remove the circuit board from the back housing. 3 The base can be corner or flat surface mounted. Drill holes as required for mounting and mount the base securely. Excess gaps or holes in the base can be filled with a flexible sealant such as silicone. 4 Replace the board. 5 Wire the PIR board and the Siren board as per the diagram opposite. 6 Set the RANGE and PULSE COUNT links to suit your application (see Program Links). 7 Replace the cover, (reverse the removal procedure). 8 After connecting power at the control panel wait approximately 30 seconds for the detector to read the environment. 9 MOUNTING HEIGHT Walk test the coverage by walking slowly across the protected area. The red alarm light should indicate detection at a maximum of 3 to 4 walking steps at a distance of 10m from the detector. The recommended mounting height for optimum performance is between 2.1 and 2.4 metres. Stop and wait for the red alarm light to turn off before continuing walk testing. Mount the detector in a location where an intruder is most likely to walk across the coverage pattern. Corner mounting usually gives the best coverage. As with all PIR detectors, it is advisable to choose mounting positions which avoid direct sunlight, heating or cooling sources and avoid areas of high humidity which may cause condensation on the lens. The mounting location of the Quantum Sonic is not critical for the operation of the onboard piezo siren - although as for the detector, corner mounting gives best results. Persons with sensitive hearing should be aware that the sound pressure levels generated when the siren is operating could be uncomfortable at close range. 10 The onboard piezo siren can be tested using your control panel's siren test procedure or by arming the system and simulating an alarm condition. If required, the optional 100-243 Quantum Bracket can be used to swivel the detector for best coverage if mounted above or below the recommended heights . 2 WIRING PROGRAM LINKS 1. Connect a regulated DC power source to the terminals marked +12V and 0V observing correct polarity. RANGE The RANGE link selects either 15m or 12m coverage range. RANGE Link ON: 15m range. RANGE Link OFF: 12m range. 2. Connect the ALARM terminals to a zone on your control panel using an End Of Line Resistor as shown in your control panel's installation manual. PULSE COUNT The PULSE COUNT link selects either of two pulse count positions. 2. Connect the SIREN +/- terminals to the RESET output on your Ness control panel. (Or any other resetting 12V DC alarm output which which can supply at least 120mA). PULSE COUNT Link ON: 1–2 Pulses or walk steps should cause an alarm. PULSE COUNT Link OFF: 3–4 Pulses or walk steps should cause an alarm. LED Remove this link to disable the walk test LED if required. QUANTUM SONIC circuit board QUANTUM SONIC wiring to a control panel. 3 COVERAGE SPECIFICATIONS Coverage is up to 15m x 15m @ 90° when mounted at a height of between 2.1 and 2.4 metres. Two vertical zones provide additional "creep zone" coverage directly below the detector. If required, the optional Quantum Bracket can used to swivel the detector for best coverage to suit the area. DIMENSIONS 109(h) x 80(w) x 50(d)mm MOUNTING HEIGHT 2.1 to 2.4m for best coverage. COVERAGE Up to 15m x 15m @ 90° plus 2 vertical creep zones. RANGE SELECT Selectable High/Low (15m/12m). PULSE COUNT Selectable 1–2 or 3–4. SENSOR Dual element pyroelectric. VISUAL DISPLAY Red alarm LED. ALARM OUTPUT Normally Closed relay, dry contacts. Max. 0.5A@24V. ONBOARD SIREN 12V Piezo Siren. ALARM PERIOD 5 seconds. TAMPER OUTPUT Normally Closed dry contacts. WARM UP PERIOD 30 seconds. OPERATING VOLTAGE 9-15V DC. CURRENT DRAW PIR: 15mA Use the optional 100-243 Quantum Bracket at other heights. SIREN: 120mA RF IMMUNITY 15V/m 10-1000MHz NESS SECURITY PRODUCTS Australian Communications Authority ELECTROMAGNETIC COMPATIBILITY COMPLIANCE QUANTUM SONIC PIR INSTALLATION NOTES Revision 1, February 2005 Document part number: 890-334 For products: 100-022 Quantum Sonic PIR © 2005 Ness Security Products Pty Ltd ABN 28 069 984 372 Optional accessory 100-243 Quantum Mounting Bracket for wall or ceiling mounting. Provides vertical and horizontal angle adjustment to provide best coverage if mounting detectors above or below recommended heights. Specifications may change without notice. 4