Transcript
NetApp Partner Training & Certification FY17 Selling ONTAP Marco Deveronico Sr Presales Consultant Milano, 31 Gennaio 2017 Ferrara, 7 Febbraio 2017 Soave (VR), 9 Febbraio 2017
[email protected]
Agenda Novita’ Certificazione Partner GOLD FY17 ONTAP 9.x Key Features FAS/AFF Platforms update Tech Refresh Tool (TRT) Esame Selling ONTAP 2
NetApp Partner Program FY17
3
FY17 EMEA Unified Partner Program Guide
4
Certificazioni necessarie per i Partner
5
NetApp Sales Promo Q4 FY17
6
FY17 EMEA Q4 Bundles and Express Pack
7
EMEA Top Seller Bundles FY17Q4 FAS2520
FAS2520
Essentials only or Premium SW
8
Bundle Nr.
Model
Controllers
HDDs
OS
1
FAS2520
Single
12x2TB
8.3 cDot
2
FAS2520
Dual
12x2TB
8.3 cDot
3
FAS2520
Dual
12x4TB
8.3 cDot
4
FAS2520
Dual
12x900GB
8.3 cDot
5
FAS2520
Dual
12x1200GB
8.3 cDot
NetApp Confidential – Limited Use
SW Essentials Only/Premium Essentials Only/Premium Essentials Only/Premium Essentials Only/Premium Essentials Only/Premium
Connectivity
4x 10G Base-T 8x 10G Base-T 8x 10G Base-T 8x 10G Base-T 8x 10G Base-T
Legacy Express Packs
Express Pack
OS/Software
Expansion Packs
Other Options
• • • • • • •
6 x 4TB HDD 12 x 6TB HDD 12 x 4TB HDD 12 x 900 GB HDD 24 x 900 GB HDD 12 x 1.2 TB HDD 24 x 1.2 TB HDD
SANtricity OS included (no Encryption <11.30)
Sold Separately
Power Cables
Other Options
9
FAS25xx
E2700
System
NetApp Confidential – Limited Use
• • • • • •
24x1.2GB HDD 24x800GB HDD 24x2TB HDD 24x4TB HDD 4x400GB SSD+ 20x2TB HDD 4x400GB SSD + 20x900 GB HDD
FAS8020 • •
48x1.2TB HDD 48x4TB HDD
FAS8040 • •
48x1.2TB HDD 48x4TB HDD
AFF8040 • •
12 x 960 GB SSD 24 x 960 GB SSD
• Base Bundle: Includes all protocols • Data Protection Bundle: SnapMirror SnapVault SnapRestore • Premium Bundle: Base + All optional software
Sold Separately
Configurable
Optics / Cables
NetApp® Support Edge or PartnerChoice Services
21 Next Gen Express Packs
Express Pack
OS/Software
• • • • •
12 x 800 GB SSD 24 x 800 GB SSD 12 x 900 GB SAS 12 x 4 TB NL SAS 12 x 8 TB NL SAS
24 x 900 GB SAS 24 x 1.2 TB SAS 12x1.2 TB SAS 20x900 GB + 4x960 GB Hybrid
Sold Separately
Power Cables
Other Options
10
• • • •
SANtricity OS included (w/Encryption 11.30+)
Expansion Packs
Other Options
FAS2650
E2800
System
NetApp Confidential – Limited Use
FAS8200 •
24 x 4TB NL SAS
AFF A300 •
12 x 3.8 TB SSD
AFF A200 • •
12 x 960 GB SSD 24 x 960 GB SSD
• Base Bundle: Includes all protocols • Premium Bundle: Base + All optional software
12 x 4TB NL-SAS
Optics / Cables
NetApp® Support Edge or PartnerChoice Services
Sold Separately
Q4 FY17 •
FAS 2620
ONTAP 9.x
11
Consolidate across environments with NetApp ONTAP 9
NetApp® ONTAP® 9 Common Data Services
12
Engineered
Converged
Third-Party
AFF + FAS
FlexPod®
FlexArray®
SDS
Near Cloud
Cloud
ONTAP Select
NetApp Private Storage
ONTAP Cloud
Lo sapevate che fino a ONTAP 8.3.x… https://library.netapp.com/ecm/ecm_download_file/ECMP12458217
13
© 2016 NetApp, Inc. All rights reserved.
Lo sapevate che invece con ONTAP 9…
14
Lo sapevate che…
N_Port ID Virtualization
15
Support GPS = Guided Problem Solving
16
Simple transition from any starting point
17
From third-party arrays
Accelerated import processes
From ONTAP 8.3
Nondisruptive update
From 7-mode
Proven tools and best practices
ONTAP 9.0 Delivery Themes
Lower $/GB and TCO Lower cost AFF storage with inline data compaction, 15.3TB SSD, ADP root-data-data partitioning
Performance More IOPs at <1ms latency, performance headroom, more consistent latency, Performance Capacity used %
Simplicity Data protection licensing, onboard encryption key management, AFF setup in <10 minutes
Added Protection and Compliance SnapLock, RAID-TEC, MetroCluster for AFF, NFS and CIFS authentication
Software-defined ONTAP ONTAP Select on commodity servers and ONTAP Cloud for AWS
18
ONTAP 9.1 Highlights
New platforms Support for more CPU cores, more memory, higher speed Ethernet and Fibre Channel
Solidify NAS leadership Massively scalable containers (FlexGroup)
Flexible encryption NetApp Volume Encryption with standard SSDs and HDDs
19
Radically change data center economics 1PB of storage <1ms latency performance to all data 11 times smaller footprint—8U vs. 2+ racks 11 times lower power consumption, 8kWh No tuning for performance
2+ racks
6-month payback
NetApp AFF 8U 10K high-performance HDDs 20
15TB SSDs, 4:1 efficiency
Proven efficiency Drive storage cost reductions: lower capex and opex Data growth NetApp® RAID-TEC™ and RAID DP® technologies
Storage Cost
NetApp Snapshot® technology Thin provisioning Cloning Inline deduplication Inline compression
Inline compaction (new)
Storage Capacity 21
Inline Adaptive Compression and Inline Data Compaction Default policy for AFF systems running ONTAP 9
Volume B
Volume A
4KB
8KB
8KB
8KB
50% compressible
80% compressible
80% compressible
55% compressible
4KB
4KB
4KB
4KB
4KB
Vol C 3x 1KB
Writes from hosts/clients
Without compression
4KB
4KB
4KB
4KB
4KB
4KB
4KB
11 blks After inline adaptive compression After inline data compaction 22
4KB
4KB
4KB
4KB
4KB
4KB
4KB
4KB
8 blks
4KB
4KB
4KB
4KB
4 blks
AFF Inline Storage Efficiency Workflow
Inline Zero-block Deduplication All-zero blocks are detected No user data is written to SSDs; only metadata is updated
23
Inline Adaptive Compression
Inline Deduplication
Compresses 8KB blocks written to storage
Deduplicates incoming blocks against recently written blocks
Aligned with I/O size used with most databases
Used in conjunction with background (postwrite) dedupe to achieve maximum space savings
Inline Data Compaction Combines 2 or more small logical blocks into a single 4KB physical block
RAID-TEC Triple Parity Protection ONTAP 9
RAID-TEC
Reducing the risk of data loss with ≥6TB HDDs requires more RAID protection Alternative: Support bigger RAID groups by adding a third parity drive RAID-TEC group sizes are 1.5–2x larger than RAIDDP for disk drives bigger than 6TB
RAID-TEC is the default for 6TB and 8TB NL-SAS HDDs RP = row parity (RAID 4)
DP = diagonal parity (RAID-DP = RP + DP) TP = triple parity (RAID-TEC = RP + DP + TP)
24
Required for 10TB and larger NL-SAS HDDs Also supported with 10k rpm SAS HDDs and SSDs
NetApp patent for triple parity (US7640484)
Advanced Drive Partitioning
25
Data ONTAP 8.3.x Root-Data (RD) Advanced Drive Partitioning Single-shelf AFF system configuration
Node A
DP
R
P
R
R
R
R
R
R
S
R
S
R
DP
R
P
R
R
R
R
S
R
S
R
DP
P
D
D
D
D
D
D
D
D
D
S
DP
P
D
D
D
D
D
D
D
D
D
S
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Node B
SSDs are partitioned into 1 small root partition and 1 large data partition Standard aggregate configuration per node: A root aggregate RAID group of 8 data + 2 parity partitions, and 2 spare root partitions A data aggregate RAID group of 9 data + 2 parity partitions, and 1 spare data partition
Total usable capacity is 18 data partitions out of a total of 24 – 75% efficiency 6 SSDs total are used for parity and spares
26
Drive Partitioning with External Shelf FAS2554 Active/Active HA configuration for 24 HDD (4T SATA) platform + External shelf Node 1 (Active)
Aggr1
Node 2 (Active)
r1 r1 r1 r1 r1 r1 r1 r1 p
p s s r2 r2 r2 r2 r2 r2 r2 r2 p
p s s
rg0 D D D D D D D D D P P S D D D D D D D D D P P S
rg1 1
External Shelf
2 3
4
5
6 7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
D D D D D D D D D D D D D D P P S
1
2
3
4
5
6 7
8
131414 15 17 16 17 2018 19 232024 9 10 11 12 13 15 16 18 19 21 22
21 22 27
23 24
ONTAP 9 Root-Data-Data (RD2) Advanced Drive Partitioning with single shelf Single-shelf AFF system configuration or FAS entry (FAS2552, FAS2650) all SSD DP
R
P
R
R
R
R
R
R
S
R
S
R
DP
R
P
R
R
R
R
S
R
R
S
DP
P
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
S
Node B
Node A DP
P
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
S
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Total usable capacity is 42 data partitions out of a total of 48 – 87.5% efficiency Partitions on 21 SSDs are used for storing data – 3 more than with RD partitioning 16.7% more usable capacity (0.875 / 0.75) 28
Root-Data-Data (R-D2) SSD partitioning – 2 shelves ONTAP 9.0
R-D2 SSD sharing with 2shelves provisions (3) partitions but slice ownership similar to Root-Data method Both Data partitions per SSD owned by (1) node (2) RAID-Groups are created for each node For AFF & FAS all SSD Use Cases with > 24 SSD, up to 48 Drives
29
Ma dove NON si puo’ usare il Partitioning? 7-mode MetroCluster FAS8000 FAS8200 FAS9000 FAS2600 EMPTY con solo cassetti esterni
30
ONTAP 9 SnapLock
31
SnapLock with ONTAP 9 NetApp WORM (Write Once Read Many) solution Single license for both solutions
New
SnapLock Compliance: SEC 17-a(4) compliant SnapLock Enterprise: supports privileged deletes Primary Storage
System Manager and Unified Manager support
SnapLock WORM Volumes
NetApp Storage Encryption (NSE) support
Archival Application
7MTT copy-based transition support at GA Not supported with initial release: Jun
30th
2040
Secondary Storage
32
New
Jun
30th
2040
DR Site
SnapLock Compliance with MetroCluster Compliance journal for SnapLock + SnapVault
New
MetroCluster
33
New with ONTAP 9 MetroCluster 8-node configuration
8-node MetroCluster™ (NAS only) 4-node (2 HA pair) cluster at each site HA pairs are replicated to respective pair at secondary site Fabric configuration only Up to 300km (FC); up to 200km (IP)
Benefits Optimize cluster configuration Mix AFF and FAS nodes and controller models Nondisruptively move data between nodes in cluster to load balance or service (changes are instantly replicated) 34
Cluster A Data Center A
Cluster B Data Center B
New with ONTAP 9 Nonmirrored aggregates
Mirror enabled/disabled at aggregate granularity Select aggregates to mirror or not mirror
Mix critical (RPO=0) and noncritical workloads in a single MetroCluster™ configuration Supported on all 2-node, 4-node, and 8-node MetroCluster configurations Example: Oracle and SAP data is synchronously replicated, and home directory data is not replicated
35
MetroCluster update Cosa e’ cambiato per le configurazioni MetroCluster 9.x e SAS3 con i nuovi FAS/AFF
ATTO 7500N per MC Stretch con SFP+ Long Wave New Stretch distance con ATTO 7500N: 500m
SAS3 cabling: Direct Optical max distance 100 metri FC-VI con porte UTA2 FAS8200/A300 Aggiornamento documenti Presales in corso
Processo di review delle nuove configurazioni
36
FlexGroup
37
What is NetApp FlexGroup FlexGroup is a scale-out file system constructed from a group of FlexVol® volumes FlexGroup looks and feels like a normal FlexVol volume to storage admins and clients FlexGroup intends to solve three problems with modern NAS in scale-out storage: Performance Consistently low latency
Capacity Essentially unlimited
Management Visually the same as FlexVol volumes /FlexGroup
38
Scale Out NAS Container – NetApp FlexGroup Single Namespace
Cluster scale container 20PB, 400 billion files, 200 constituents
Linear scaling for performance and/or capacity Consistent performance Seamlessly scalability of capacity
B A3
Operational simplicity
C1
C
C2
C3 B2
A1
A2 B1
Provision, manage, and monitor workflow behavior Out-of-box automated provisioning
Operational efficiency Leverage existing aggregates and SVMs Run NAS and SAN workloads in the same cluster
39
• • • •
Auto capacity balanced container Granular data management Multi-protocol support – NFS + SMB 2.x Foundation for emerging applications
Onboard Key Manager & Volume Encryption
40
Onboard Key Manager NetApp Storage Encryption (NSE) for AFF and FAS
Onboard Key Manager (OKM)
Onboard Key Manager
External Key Server (KMIP)
Simple
Compliance
Quickly deploy data at-rest encryption One-time passphrase configuration Passphrase protects keys
Integrated Included with ONTAP 9 at no cost Enables self-contained encryption solution
Automatic Creates all required keys Automatically generates AES-256 encryption keys where needed
Meets FIPS 140-2 requirement Higher FIPS compliance requires external key server appliance
Multi-Cluster Single key server supports many clusters Centrally manage all encryption keys
Industry Standard Supports industry KMIP standard Redundant HA key management NetApp qualified key servers – check IMT
NSE SSD
Only one type of key manager can be used per cluster 41
NetApp Volume Encryption Software-based data at-rest encryption
Encrypt data on storage with standard SSDs and HDDs
Write (encrypt)
Supported with AFF, FAS, MetroCluster, and ONTAP Select Data on existing systems can be encrypted using volume move
Read (decrypt)
request response Network
Zero-management encryption solution for data on disk
WAFL
Leverage storage efficiency features with encryption Encrypt on high capacity drives that don’t have an equivalent NSE model (e.g. 15.3TB SSD) Cryptographic Module (CM) encrypts volume data prior to writing to storage; data is decrypted before it reaches WAFL
42
Cryptographic Module
RAID Storage
Encryption Keys and Key Management NetApp Volume Encryption (NVE)
Unique protection for every data volume XTS-AES-256 data encryption key per volume Node root and SVM root volumes are not encrypted
NVE-capable ONTAP image required
$0 license required to enable NVE Encryption keys are stored and protected by Onboard Key Manager (OKM) OKM included with ONTAP 9 at no cost
43
Supported platforms AFF8000 and new AFF platforms FAS8000, FAS6280/90, and new FAS platforms NO FAS2500, FAS2200
Encrypting an existing volume Re-keying and decrypting a volume is done via a volume move operation
FIPS 140-2 Level 2 compliance NetApp Storage Encryption (NSE) systems and external KMIP server still required
Software Defined ONTAP
44
Software Defined Storage ONTAP Cloud versus ONTAP Select
ONTAP Cloud ONTAP running in a hyperscaler service provider environment Amazon Web Services (AWS) and Azure
License model designed for cloud consumption mentality Use cases Cloud replication/DR Dev/test, file services, database applications
45
ONTAP Select ONTAP running on-premise on commodity hardware NetApp-qualified major server vendors
Flexible capacity-based licensing Use cases Primary storage for Tier 2 and 3 workloads Private cloud storage services Disaster recovery/secondary storage
What’s New with ONTAP Select
…
VMs / Hosts
File Services
Software defined ONTAP ONTAP Select
What customer problems does ONTAP Select address? Reduce your TCO by leveraging commodity based hardware Business agility by deploying ONTAP Select in a few minutes Enterprise-class availability for biz apps – home directories, web apps,… Efficient and effective data protection with ONTAP values
ONTAP Select availability
Hypervisor Commodity
… iSCSI
9.0 RC1: Support for VMware vSphere 9.1 RC1: ONTAP Select Premium for license for SSDs (8 virtual CPUs, 64GB memory)
Starting from: 46
…
DAS
SMB/ CIFS
NFS
HA
Hypervisor
HA
Hypervisor
Hypervisor
2TB (single node) 3TB (multi node HA) Four-node configuration
Hypervisor
ONTAP Cloud for AWS and Azure AWS
Azure
High Availability for AWS
Deploy ONTAP operating system as software in the cloud
Max capacity per node support is 368TB
No HA capability
Protection against a single Availability Zone failure Max capacity per node support is 31TB
Further enable a common set of data services in the cloud Expand options to own and now lease or rent on demand 47
Performance
48
Optimized Resource Utilization Mix and match storage tiers on one controller SATA load impact on co-located SSD Aggr Avg Latency
8.3.1 SSD
8.3.1 SATA
9.0 SATA
9.0 SSD
With ONTAP 9 Flash aggrs and HDD aggrs can coexist happily on the same controller Application performance on Flash tier is isolated from the HDD tier
Performance of healthy aggrs is protected from slow aggrs
Simpler hybrid FAS setup – no need to isolate SSD aggrs on a separate node 49
Performance Capacity Metric, Optimal point, Performance Capacity used and Headroom Performance Capacity (%) Incorporates resource utilization and latency (response time) into a single performance metric Depends on resource physical hardware capabilities Workload mix Performance metric for node and aggregate
Optimal point 100% performance capacity used is called the “ optimal point” Point at which output of a resource is optimal within desired latency limits A little increase in utilization beyond optimal point has a bigger increase in latency
Performance Capacity used (%) Headroom = Performance Capacity free A resource remaining useful capacity when measured from optimal point 50
Available IOPS Absolute value
Available IOPS tells you the number of IOPS that can be added to the resource before reaching the maximum performance capacity
Available IOPS is the estimated amount of remaining average IOPS for a resource You can add workloads of a predetermined number of IOPS to a resource
Total IOPS based on physical characteristics of the node or disks Node: number of CPUs, CPU speed , amount of RAM Aggregate: SATA, SAS, SSD disk 51
Fast Failover with Prescriptive AFF SAN Configurations
Architected for >99.999% Availability Planned Failover
Unplanned
2-10
2-15
Secs
Secs
Innovation Patents Pending
52
Failover
More Deferred Processing Reduction in path-length
Finer Grain Data Management Increased Parallelization
Continuous Performance Improvement since Data ONTAP 8.3 Increased random read-write throughput at low latencies on AFF systems
Improvements in every release since AFF8000 was introduced with 8.3 30% throughput increase @ 1 ms (ONTAP 9.0 vs 8.3)
85% increase @ 600 µs (9.0 vs 8.3)
1 ms
Result of multiple optimizations of read-write data paths, resource scheduling, and message processing
+30%
1x
53
2x
3x
4x
5x
6x
7x
Nuovi sistemi FAS / AFF
54
Biggest Hardware Platform Refresh in NetApp History! Powered by ONTAP 9.1
Accelerate enterprise applications Deploy next-gen data center: 32Gb FC SAN and 40GbE networking Onboard NVMe flash for read caching High performance systems FAS2600: +200% vs FAS2500 running 8.3.x FAS8200: +50% vs FAS8040 running 8.3.x FAS9000: +50% vs FAS8080 EX running 8.3.x
FAS9000 Designed for business critical workloads Simplified serviceability Over 14 PB capacity
FAS8200 Built for enterprise workloads 5 PB capacity
Simplify deployment Simpler cluster setup via System Manager Easier serviceability
More flexible Massive NAS volumes – FlexGroup 12-node SAN clusters 55
FAS2650 FAS2620*
Optimized for small-enterprises and mid-size businesses FAS2650: 24 internal drives FAS2620: 12 internal drives* * Available 02/2017
NetApp FAS Hybrid Unified Scale-Out Storage Simplified unified scale-out portfolio
FAS9000
FAS8080 EX
FAS8200 FAS8060
FAS2650 FAS8040
FAS2620* FAS8020
New Portfolio
High-End
FAS2552
FAS2554 FAS2520
Mid-Range Current FAS
Entry * FAS2620 availability is targeted for Q1 CY2017 56
Storage ibrido unificato NetApp FAS Linea di prodotti completamente rinnovata
Aumento significativo di velocità e reattività
FAS9000
Performance migliorate fino al 200%
Carichi di lavoro business-critical
Flash Cache™ NVMe inclusa in tutti i modelli Connettività dalle performance elevate
Miglioramento della disponibilità e della sicurezza Riduzione del TCO
57
FAS8200 Carichi di lavoro enterprise
FAS2600
Piccole e medie imprese
FAS2600 ottimizzato per piccole e medie imprese FAS2620: 12 dischi LFF (3,5’’) interni per una maggiore capacità
FAS2650: 24 dischi SFF (2,5’’) interni per performance più elevate
FAS2620 12 dischi LFF interni da 3,5"
1,4 PB
Performance elevate Fino a 3 volte superiori Flash Cache™ NVMe integrata
Connettività potenziata 4 porte UTA-2 per controller tutte disponibili Nessuna porta std 1GbE
Scalabilità verticale fino a 1 PB, scalabilità orizzontale fino a 5 PB 2U rack space 58
144 dischi
FAS2650 24 dischi SFF interni da 2,5"
1,2 PB 144 dischi
Il nuovo FAS2600 Cosa cambia rispetto al FAS2500 1) 3x performance improvement HA pairs
12 CPU cores: 3x more physical cores 64GB memory: ~2x more memory 8GB NVMEM: 2x more NVMEM
2) Onboard 1TB (512GB x 2) NVMe M.2 Flash Cache™ FAS2600
3) Persistent write log (NVMEM destaging) 4) Enhanced I/O layout
59
2 SAS3 ports for external storage (miniSAS-HD) 2 10GbE dedicated cluster interconnect ports 4 UTA2 16Gb FC or 10GbE ports, also supports GbE USB port that works! New USB-based console port, 115K baud
FAS2600 HA configuration e controller I/O
Mini SAS3 Ports (2)
10GbE Cluster Interconnect Ports (2)
Micro USB
RJ45
Serial Console Port
Serial Console Port
UTA2 Ports (4)
USB Port
e0M Management Port
60
Unified Target Adapter 2 (UTA2) ports Overview
UTA2 ASICs are dual port Two ports on ASIC are call port pair
Port pair must be set the same: FC or Ethernet Two steps needed to set port personality in the field: Pick from FC or CNA personalities for ASIC ONTAP® 9 set port command: system node hardware unified-connect
Install appropriate SFP+ or twinax cable when using CNA Ethernet personality
When set to FC, both ports on ASIC can be set to either target or initiator When set to CNA, GbE and 10GbE SFPs can be used on same ASIC Reboot required to change personality or target/initiator mode 61
UTA2 transceivers GbE SFP part number
X6567-R6: SFP optical 1GB shortwave multimode X6568-R6: SFP copper 1GB RJ-45 NFS, CIFS, iSCSI supported; FCoE not supported Not supported for cluster interconnects GbE and 10GbE SFPs can be used on same ASIC
10GbE X6589-R6: XCVR, SFP+, optical, 10GbE, shortwave GbE and 10GbE SFPs can be used on same ASIC
16GB FC X6596-R6: XCVR, SFP+, optical, 16Gb, FC, shortwave Autoranges between 4Gb, 8Gb, and 16Gb
16Gb FC long-reach (LR) part number X65403 62
HWU: Hardware Universe (hwu.netapp.com)
63
© 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
FAS8200 progettato per carichi di lavoro enterprise Performance elevate Fino al 50% superiori Flash Cache™ NVMe integrata (1TB std, 2TB max x controller)
Connettività mai vista prima nel settore Fibre Channel 32 Gb Ethernet 40 Gb
Scalabilità verticale fino a 4,8 PB, scalabilità orizzontale fino a 57 PB Footprint 3U ridotto
64
FAS8200 4,8 PB 480 dischi Chassis 3U
Il nuovo FAS8200 Cosa cambia rispetto al FAS8040 HA pairs
~50% performance improvement 32 CPU cores: 2 times more cores 256GB memory: 4 times more memory
Onboard NVMe M.2 flash (up to 4TB x HA-pair)
Persistent write cache Enhanced I/O layout
FAS8200
65
4 mini-SAS3 ports for external storage 2 10GbE cluster interconnect ports 4 UTA2 16Gb FC or 10GbE ports; also supports GbE 2 10GbE Base-T ports PCIe Gen3 architecture USB port that works! New USB-based console port, 115K baud
FAS8200 HA configuration e controller I/O
e0M Mini-SAS3 Ports (4)
10GbE Cluster Interconnect Ports (2)
66
10GbE Base-T Ports (2)
UTA2 Ports (4)
Management
USB Port
Slots (2)
Port
RJ45
Micro USB
Serial Console Port
Serial Console Port
FAS9000 progettato per carichi di lavoro business-critical Design modulare intelligente RAS di livello superiore Il percorso di upgrade semplificato estende il ciclo di vita del sistema
Performance elevate Fino al 50% superiori Flash Cache™ NVMe integrata
Connettività mai vista prima nel settore
FAS9000
Fibre Channel 32 Gb Ethernet 40 Gb
Affidabilità garantita al 99,9999%
14,4 PB
Scalabilità verticale fino a 14,4 PB, scalabilità orizzontale fino a 172 PB
1.440 dischi Chassis 8U
Riduzione del TCO grazie a high availability, estensione della durata del prodotto e manutenzione semplificata
67
Il nuovo FAS9000 Cosa cambia rispetto al FAS8080 EX 1) ~50% performance improvement HA pairs
72 CPU cores: 80% more cores 1024GB memory: 4x increase DDR4 memory
64GB NVRAM: 2x more NVRAM High-speed HA interconnect, 80Gb bandwidth
2) Onboard NVMe-attached SSD flash 3) Enhanced I/O layout
FAS9000 68
I/O slots outside processor module PCIe Gen3 slots, X16 wide lanes for each I/O slot 10 I/O slots per controller (plus 2 NVMe slots) USB port that works New USB-based console port, 115K baud
FAS9000: HA configuration e controller I/O design modulare Due controller indipendenti con:
FAS9000 - Vista posteriore
10 slot I/O PCIe per controller Slot da 2 NVMe per ogni controller Schede I/O indipendenti dal servizio
NVRAM modules (behind NVMe)
I/O flessibile dalle performance elevate Aggiungi scalabilità ed esegui upgrade in base alle esigenze 40 GbE, 10 GbE 32Gb FC, 16Gb FC SAS-3 12 Gb
69
20 I/O modules
4 NVMe modules
FAS9000: progettato per un RAS di livello superiore FAS9000 - Vista posteriore Progettato per una disponibilità pari al 99,9999% Progettazione modulare per la serviceability Sostituzione indipendente di controller e schede I/O
Moduli I/O inseribili singolarmente Sostituzione senza alterazione del cablaggio Semplifica e accelera la manutenzione Riduce la probabilità di errore
Ventole, batterie NVRAM e alimentatori ridondanti Supporta un'estensione significativa della capacità Fino a 172 PB 70
FAS9000
Semplifica la scalabilità Scala i carichi di lavoro delle applicazioni senza downtime
Aggiungi nuovi carichi di lavoro delle applicazioni ai sistemi FAS in uso Fai scale-up e/o scale-out in base alle tue esigenze aziendali Fai scale-up della capacità fino a 14 PB Fai scale-out di performance e capacità fino a 172 PB Gli upgrade di performance e capacità sono trasparenti
71
Fai scale-out per SAN e NAS FAS2600 8 nodi e 576 dischi (SAN e NAS)
FAS8200
FAS9000
12 nodi e 2.880 dischi (SAN, unificati)
12 nodi e 8.640 dischi (SAN, unificati)
24 nodi e 5.760 dischi (NAS)
24 nodi e 17.280 dischi (NAS)
Next-generation controller performance HA pairs Next-Generation FAS Performance File System Workload (NFS) 600000
500000
IOPs
400000
300000
200000
100000
0 FAS2552
72
FAS2600
FAS8040
FAS8200
FAS8080 EX
FAS9000
Next-generation controller performance HA pairs Next-Generation FAS Performance OLTP Workload (FC) 300000
250000
IOPs
200000
150000
100000
50000
0 FAS2552
73
FAS2600
FAS8040
FAS8200
FAS8080 EX
FAS9000
DS460C: Shelf Overview
DSxxxx – Disk shelf DS4xxx – 4U DSx60x – 60 drives DSxxxC – 12Gb/s SAS (aggregate 48Gb/sec per SAS Domain) 74
DS460C - Shelf Front View Drawer 1 Electronic Shelf ID Power
Warning
Blue LED Beacon Drawer 5 Operator Display Panel Button
75
DS460C - Shelf Rear View PSU
IOM A
FAN
FAN
PSU
76
IOM B
Quotable SAS-3 Drive Configurations – Add-on Storage SAS-3 Drive Support Drive Category
Drive Type
Capacity
Capacity
SATA/NL-SAS – 7.2K RPM
*4TB, 6TB NSE, *8TB, *10TB, *10TB NSE
Performance
SAS – 10K RPM
900G, 1.2TB, 1.8TB, 1.8TB NSE
Ultra Performance SSD
Comments
77
800G NSE, *960G MSW, 3.8TB MSW, 3.8TB NSE, 15.3TB
MSW — Multi-stream write NSE — FIPS 140-2 compliant DS460C supported capacities * DS212C supports 6Gb/s Legacy Large Form Factor (LFF) drives DS224C supports 6Gb/s Legacy Small Form Factor (SFF) drives
12Gb SAS-3 IOM12 Expander Module 12Gb SAS-3 IOM12 Expander Module Enable 12Gbps SAS-3 support 12Gb SAS native speed to stack 48Gbs aggregated 4x wide per SAS channel – DS224C, DS212C, DS460C
IOM12 Upgrade path for 3 & 6 Gb/s shelves DS4246 + IOM12 DS4243 + IOM12 DS2246 + IOM12
Improved connectivity Supports four ports of Mini-SAS HD connectivity Dual and quad path cabling options
In-band Alternate Control Path (IBACP) only 78
Eliminates external ACP Ethernet connections Out-of-Band ACP (OOBACP) Note: IOM6 supports IBACP but requires minimum shelf firmware 0209
SAS-3 Examples Storage: New Shelves SAS-3 12Gb/s
DS224C
DS212C
DS460C
Performance
Capacity
Density
Rack Space
2U
2U
4U
Drive Slots
24
12
60
Drive Size
SFF - 2.5”
LFF- 3.5”
LFF-3.5”
Drive Types
SSD 10K SAS
Segment
79
SSD (Hybrid Only) SSD (Hybrid Only) 7.2K NL-SAS 7.2K NL-SAS
SAS Interface Speed
12Gb/s
12Gb/s
12Gb/s
Backplane Speed
12Gb/s
12Gb/s
12Gb/s
9.0 or later
9.0 or later
9.1RC2 or later
NetApp® ONTAP®
Upgrade Path: 3/6 Gb/s Shelves + IOM12 DS2246 + IOM12
DS4246 + IOM12
DS4243 + IOM12
Performance
Capacity
Capacity
Rack Space
2U
4U
4U
Drive Slots
24
24
24
Drive Size
SFF - 2.5”
LFF- 3.5”
LFF- 3.5”
Drive Types
SSD 10K SAS
SSD 7.2K NL-SAS
SSD 7.2K NL-SAS
SAS Interface Speed
12Gb/s
12Gb/s
12Gb/s
Backplane Speed
6Gb/s
6Gb/s
6Gb/s
9.0 or later
9.0 or later
9.0 or later
Segment
NetApp® ONTAP®
*All drives in support matrix for DS4243, DS2246 & DS4246 will be supported on 9.x in upgraded shelf + IOM12 (or +IOM6) configuration including 15k SAS; must be within 5 year window of original sale to qualify for service entitlement drive replacements 80
Upgrade Path: 3Gb/s Shelves + IOM6 DS4243 + IOM6 Segment
Capacity
Rack Space
4U
Drive Slots
24
Drive Size
LFF- 3.5”
Drive Types
SSD 7.2K NL-SAS
SAS Interface Speed
6Gb/s
Backplane Speed
6Gb/s
NetApp® ONTAP®
9.0 or later
All drives in support matrix for DS4243 will be supported on 9.x in upgraded shelf + IOM6 configuration including 15k SAS; must be within 5 year window of original sale to qualify for service entitlement drive replacements 81
Supported SAS-3 Use Case Example: Cables HBA/expander cable connectors – Support 12Gb/s connectivity: Native SAS-3 - both endpoints Mini-SAS HD Transitional Cable SAS-3 – (1) endpoint Mini-SAS HD & (1) endpoint QSFP
82
Next Generation High Speed Networking Infrastructure
secs
32Gb FC and 40GbE
3132Q-V
Brocade X6 Directors X6-4 and X6-8
Connectivity to 8 Gbps flash storage Source: Emulex/Broadcom TPC-H benchmark testing
32Gb SAN infrastructure First enterprise platforms to enable next generation 32Gb FC SAN 2-port 32Gb FC adapter
Nexus 9300 and 5600
End-to-end 40GbE infrastructure Nexus 5600 and Nexus 9300 series switches 2-port 40GbE cards
Deploy 40GbE cluster infrastructure with 32-port Cisco 3132Q-V switch High-density top-of-rack switch Optimized for ultra-low nominal latency
Flash storage demands maximum network speed and throughput 83
AFF (All Flash FAS) Systems Portfolio AFF A700
AFF A300
New platform planned
AFF A200
New Portfolio
AFF8080
AFF8040
Current Portfolio
Mid-Range Entry
84
High-End
All-Flash FAS (AFF) A200 New entry AFF platform
Based on the FAS2650 hardware 2U enclosure Two controllers in HA configuration 24 x 2.5” form-factor drive bays
85
AFF A200: New Entry AFF System Leverages new 12Gbps SAS enclosure architecture Full 12Gbps SAS connectivity to internal and external drives Design leveraged from the DS224C storage shelf
Based on latest Intel Broadwell-DE 6-core processor Significant performance increase over FAS8020 Enhanced I/O capabilities with more configuration flexibility in a 2U enclosure
86
Introducing the AFF A200 HA pairs
What’s New in the AFF A200 Processor and memory CPU: 12 cores (same core count as AFF8020) Memory: 64GB (50% more than AFF8020) 8GB is used as NVMEM
Onboard I/O ports (per controller) 2x 10GbE: Cluster interconnect 4x UTA2 (16Gbps FC or 10GbE): Host connectivity Also configurable as 1GbE
2x 12Gb mini-HD SAS: External storage attachment DS224C and DS2246 shelves are supported
1x Type micro-B USB console port: 115.2k baud rate Type-A USB port: Read-only for netboot and OS update
Persistent write log NVlog written to flash if unplanned power loss occurs 87
Supported SSDs and External Storage Shelves Configured systems Internal SSDs: 12 or 24 drives 960GB, 3.8TB, 15.3TB (restricted quoting) NSE: 800GB, 3.8TB
DS224C storage shelf: 12 or 24 drives 960GB, 3.8TB, 15.3TB (restricted quoting) NSE: 800GB, 3.8TB
External expansion storage Internal: 6-drive packs Non-NSE: 960GB, 3.8TB, 15.3TB NSE: 800GB, 3.8TB
DS224C storage shelf: 12 or 24 drives Non-NSE: 960GB, 3.8TB, 15.3TB NSE: 800GB, 3.8TB 6-drive packs are also available
DS2246 storage shelf: IOM6 or IOM12 Non-NSE: 400GB, 800GB, 1.6TB, 3.8TB NSE: 800GB, 1.6TB, 3.8TB
88
AFF A200 Performance AFF A200 versus AFF8040 Workload
AFF A200
AFF8040
100% 8KB random read @ 1 ms
148k IOPS
143k IOPS
OLTP (40% read, 60% write) @ 1 ms
60k IOPS
100k IOPS
File serving (read/write mix)
106k OPS
140k OPS
100% sequential read
5.0 GB/s
5.5 GB/s
100% sequential write
2.1 GB/s
2.5 GB/s
Random performance: 60 – 100% of AFF8040 Sequential performance: 85 – 90% of AFF8040
89
Systems at a Glance: AFF A-Series and AFF8000 Series HA pair specifications AFF8020
AFF A200
AFF8040
AFF8060
AFF A300
AFF8080
AFF A700
Form factor
3U
2U1
6U
6U / 12U2
3U
6U / 12U2
8U
CPU cores
12
12
16
32
32
40
72
Physical memory
48GB
64GB3
64GB
128GB
256GB3
256GB
1024GB
Max drive count
240
144
384
480
384
384 / 480
480
8GB
8GB
16GB
16GB
16GB
32GB
64GB
NVMEM / NVRAM
Onboard / Pre-Configured Ports 32Gb FC
-
-
-
-
-
-
-
40GbE
-
-
-
-
-
-
8
10GbE
4
4
8
8
4
8
-
UTA2
4
8
8
8
8
8
-
10GBase-T
-
-
-
-
4
-
-
1GbE
4
-
8
8
-
8
-
SAS
4 (6Gb)
4 (12Gb)
8 (6Gb)
8 (6Gb)
8 (12Gb)
8 (6Gb)
8 (12Gb)
4
-
8
8 / 242
4
6 / 242
16
8.3+
9.1RC2+
8.3+
8.3+
9.1RC1+
8.3+
9.1RC2+
I/O Expansion Slots Data ONTAP® support
90
1. 2. 3. 4.
Chassis includes 24 drive bays Higher rack unit size (U) and I/O card slots when configured with IOXM expanders A200: 8GB used for NVMEM; A300: 16GB used for NVMEM A700s: Platform is offered in 2 configurations: NAS & NAS/SAN. FC ports are available in SAN configurations only. 32Gb ports are also capable of running at 16Gb and 8Gb speeds.
“We protect and manage the World’s data”
[email protected]
https://setools.netapp.com/
99
Selling ONTAP exam
100
Buon Pranzo a tutti
[email protected]