International
NetVanta 8044 Carrier Ethernet Network Termination
Product Features ■ Four
integrated 10/100/ 1000Base-T Ethernet ports
■ Four
SFPs to support both 100 Mbps and Gigabit Ethernet connections
■ MEF
9 and 14 Compliant Ethernet over Fibre services delivery
■ Configurable
Queuing, Scheduling, Traffic Policing and Shaping for CoS support
■ Configurable
EtherType and TPID for service flexibility
■ 1
RMU stackable with wallmount or rackmount options
■ Rapid
deployment via EZ-Ethernet Provisioning
■ Command
Line Interface (CLI)
■ Standards-based
supported
Carrier Ethernet (CE) or Metro Ethernet (ME) access continues to gain acceptance as a business class service delivery technology. Carrier Ethernet service dramatically reduces the complexity required to deploy Layer 2 services such as transparent LAN services and Layer 2 VPNs. In addition CE allows the delivery of managed Layer 3 services, such as voice and video. Carrier Ethernet enables carriers to lower operating costs as a result of a reduction in network management complexity. Carrier Ethernet provides operators the ability to effectively extend and scale customer deployment with reliable, flexible Class of Service (CoS) and Quality of Service (QoS) control.
Termination Unit (NTU) portfolio, which already includes Ethernet over Copper (EoCu) and Ethernet over TDM (EoTDM) solutions, introduces the NetVanta 8044. The NetVanta 8044 is a Gigabit Ethernet NTU or Ethernet Access Gateway (EAG). This NTU will support point to point deployment for Gigabit Ethernet services from the Total Access 5000 Carrier Ethernet Access Platform or any other Ethernet service platform that support standards based EoF implementations. The ADTRAN EoF solution is a MEF compliant solution supporting familiar operations tools based on both Connectivity Fault Management (CFM) and Performance Monitoring (PM) EthOAM standards as well as authentication standards such as RADIUS and TACACS+.
In order to support Ethernet over Fibre (EoF) services delivery, the ADTRAN NetVanta Carrier Ethernet Network
EthOAM GigE Metro Ethernet & IP Core
■ Fault
detection, notification, verification, isolation functions monitoring with threshold alarms
GigE
Total Access 5000
■ Performance
10 RU
■ Small
Form-factor Pluggable (SFP) 1000Base-X Ethernet
Unch. DS3 Ch. DS3 or E1
Fibre
Bonded e.SHDSL Pairs
Bonded e.SHDSL Pairs
TDM Transport
NetVanta 8044
DS3 1
PWR
10-40 Mbps Ethernet
ACO
DS3 STATUS 1
NetVanta 832 NET LOOP2 LOOP1
2-10 Mbps Ethernet
ACT
2
ALARM
3
EFM GIG E
4 x 10/100Base-T or GigE SFP
ETH
NetVanta 838 1172830G1
ILL068A
NetVanta 873 NetVanta 818
NetVanta 838 OSP
50-1000 Mbps Ethernet
Bonded DS3 Circuits
Bonded E1 Circuits
20-100 Mbps Ethernet 10 Mbps Ethernet
4G Base Station
4G Base Station
ADTRAN Ethernet Service Access Architecture. Ethernet over Fibre, e.SHDSL, DS1 or DS3.
DS3 2
DS3 3
NetVanta 873 1200639
ADTRAN, Inc. Global Department 901 Explorer Boulevard Huntsville, Alabama 35806 USA www.adtran.com/global U.S. Headquarters +1 256 963 8000 +1 256 963 6300 fax
[email protected] Global Customer Service +1 256 963 8716 voice Asia—Beijing, China +86 10 8527 5011 +86 10 8527 5010 fax
[email protected] Hong Kong +852 3187 7111 +852 2116 4084 fax
[email protected] Asia—Bangkok, Thailand +66 2 610 3724 +66 2 610 3601 fax
[email protected] Asia—Singapore +65 6232 2305 +65 6232 2888 fax
[email protected] Australia/New Zealand— Melbourne, Australia +61 3 9658 0500 +61 3 9658 0599 fax
[email protected] Australia/New Zealand— Sydney, Australia +61 2 8456 0101 +61 2 8456 0105
[email protected] Canada—Montreal, Quebec +1 877 923 8726 +1 514 940 2888 +1 514 989 3198 fax
[email protected] ADTRAN Networks Canada— Ottawa, Ontario +1 877 923 8726 +1 514 940 2888 +1 514 989 3198 fax
[email protected] Canada Headquarters— Toronto, Ontario +1 877 923 8726
[email protected] EMEA Regional Headquarters— United Kingdom +1 613-599-9698 +1 613-599-7457 fax
[email protected] Mexico/Central America/ Caribbean—USA +1 256 963 4833 +1 256 963 6300 fax
[email protected] [email protected] [email protected] [email protected] South America—USA +1 256 963 3113 +1 256 963 6300 fax
[email protected] [email protected] [email protected]
NetVanta 8044 Carrier Ethernet Network Termination Front Panel Interfaces
■ Four 10/100/1000 BaseT Ethernet interface via RJ-45
■ Four Gigabit Ethernet interface via SFP cages,
angled to reduce overall product depth and improve cable management ■ All Ethernet ports may be used for either network
WAN or customer-side LAN connections
■ 100BaseX SFP also supported to allow Fast Ethernet
fibre lease ■ DB9 local craft port for support of RS-232 interface
for local management
Physical Dimensions
■ Desk, rack and wall mountable ■ Rack mountable solution in 19” or 23” wide
telecom racks ■ Height: 44mm ■ Width: 1437mm ■ Depth: 254mm; 301mm with fibre guide ■ Weight: 2.75 kg
Power Supply and Power Consumption ■ Wide mouth AC powering version o
o
Configurable MTU from 1500 to 9k Jumbo frame in four bytes increments o 4k active MAC address; Ability to disable MAC learning o 1k EVC per device o Ingress policers (tr3CM) per device, CIR and EIR settings to 64kbps granularity, Configurable Burst through EBS, CBS settings o
o
Egress shaping per port
Fault and Performance Management ■ IEEE 802.3ah Link OAM
■ IEEE 802.1ag Connectivity Fault Management (CFM) ■ IETF TWAMP Layer 3 Performance Monitoring ■ ITU-T Y.1731 Layer 2 Performance Monitoring (2010)
Security
■ TACASC+ Authentication, Authorisation ■ RADUIS Authentication, Authorisation ■ SSHv1/v2 and SFTP (2010) ■ SNMPv1/v2 (today), SNMPv3 (2011)
Regulatory Agency Approvals
IEC cord set options for US/CDN, EU and Australian 10 A/240 V plug
■ FCC Part 15 Class A
100–250 V at 50 or 60 Hz
■ UL 60950, CAN/CSA C22.2 No. 60950
■ FCC Part 68
■ Ground/Earth provided via Post & Lug type connector
■ EN 60950, IEC 60950, AS 3260/ AS NZS60950
■ Typical power consumption is 14 to 18W maximum
■ NEBS Level 3
Environmental Hardening
■ Operating Temperature: -40°C to 65 °C ■ Storage Temperature: -40°C to 85 °C ■ Relative Humidity: GR-63-CORE 5% to 95%,
■ RoHS 2002/95/EC ■ ITU-T K21:2000 Basic
Device Management
■ Common operational model (i.e. FCAPS) used for
non-condensing
Ethernet Services Support
■ Classification of Traffic based on:
Per UNI port, CE VLAN ID (C-Tag) and/or CE VLAN P-bits, Soure and/or destination MAC address, DSCP fields ■ Single stack VLAN and double stack VLANs (Q-in-Q) o Manipulation based on 802.1p and DSCP fields o STAG TPID provisioning supports 802.1ad and 802.1Q standards o Port based service support ■ Services Scale and Flexibility o MEF 9, 14 compliant EPL, EVPL, ELAN, ETREE o 8 Queues and Strict Priority Schedulers o Configurable EtherType and TPID for service flexibility o VLAN IDs 0 – 4095; EVC configurable in the range of 1 – 4094
o
every Ethernet access method ■ Local management via DB-9 RS232 or via a
10/100/1000 copper port ■ Telnet via an IP-based connection
o
o
Inband management on any VLAN from 2 to 4094 Secure Shell (SSH) via any secure client/server application (2010)
■ Total Access EMS, element management system
o
SNMPv1/2, SNMPv3 (future)
o
TL1 or XML (future) gateway
Ordering Information Equipment
NetVanta 8044 AC version
I61172805G1-8A September 2010 Copyright © 2010 ADTRAN, Inc. All rights reserved.
1172805G1
Supported Small Form Factor Pluggables (SFPs) for this product may be found at www.adtran.com/sfp
TL19.1270
ADTRAN is an ISO 9001, ISO 14001, and a TL 9000 certified supplier.
Part #
ADTRAN believes the information in this publication to be accurate as of publication date, and is not responsible for error. Specifications subject to change without notice. ADTRAN and NetVanta are registered trademarks of ADTRAN, Inc. and its affiliates in the U.S. and certain other countries. All other trademarks mentioned in this document are the property of their respective owners. Five-year warranty applies only to products sold in North America. ADTRAN products may be subject to U.S. export controls and other trade restrictions. Any export, re-export, or transfer of the products contrary to law is prohibited. For more information regarding ADTRAN's export license, please visit www.adtran.com/exportlicense