Preview only show first 10 pages with watermark. For full document please download

New Spec Sheets

   EMBED


Share

Transcript

M7 (HEM-780-E) Fully Automatic Blood Pressure Monitor Product Features • Fully Automatic Upper Arm BPM • Oscillometric measurement with Fuzzy Logic • Dual size preformed cuff (22cm - 42cm arm circumference) included • 3 Line display for Sys, Dia and Pulse • Table top design for optimal viewing angle • 90 Measurement memory with date and time • Battery last approx 300 measurements. • 3 year OMRON guarantee • Error information messages OMRON M7 product specifications Type: Product code: Measuring range: Accuracy: Display: Inflation: Deflation: Pressure detection: Measuring Method: Memory: Power supply Battery life: Operating temperature: Operating humidity: Operating environment: Storage temperature: Storage humidity: Weight unit: Weight cuff: Outer dimensions: Cuff Dimensions: Accessories: Classification: CE mark: Optional Accessories: Manufacturer: OMRON M7 HEM-780-E Blood pressure: 0 mmHg – 299 mmHg, Pulse: 40 – 180 beats/minute Blood pressure: +/- 3 mmHg, Pulse: +/- 5% of reading Digital LCD Automatic inflation (Fuzzy-Logic control) Automatic air release by controlled air release valve. Electrostatic capacitive pressure sensor. Oscillometric method 90 measurements 4x AA size batteries / AC/DC adapter option New batteries will last for approximately 300 measurements. +10°C to +40°C 30% to max 85% relative humidity Free from excessive vibrations, Shocks, Magnetic fields, Electrical noise, ect. -20°C to +60°C 10% to max 95% relative humidity Approximately 400g excl. batteries Approximately 130g Approximately 165 mm wide Approximately 73 mm height Approximately 110 mm depth Approximately 150 cm wide x 582 cm length Arm circumference 22 – 42 cm Cuff HEM-Cuff-P (type CL21A P01) Arm circumference 22 – 42 cm Instruction manual Guarantee card Blood pressure pass 4 alkaline batteries Storage case type B CE0197 AC/DC adapter (OMRON F) 220V~50Hz / 55mA / 13VA 6V DC / 600mA / 3,6VA OMRON HEALTCARE Co.,Ltd. Kyoto, 615-0085 Japan EC Directive: European standard: 93/42/EEC (Medical Device Directive) EN1060, Non-invasive sphygmomanometers Part 1: General Requirements Part 3: Supplementary requirements for electromechanical blood pressure measuring systems. Note: Subject to technical specifications may be modified without prior notice. White Medical, Meranti Lodge, Hillmorton Lane, Clifton upon Dunsmore, Rugby, CV23 0BA. Tel: 01788 553904, Fax: 01788 560820, [email protected], www.white-medical.co.uk