Transcript
Installation Inst ruct io n s
NextGen Selectronic®
Integrated Faucet with Optional Above-Deck Mixing & SmarTherm™ Temperature Limiter
MODEL NUMBERS 7755.1xx 775B.1xx 7755.2xx 775B.2xx 7755.3xx 775B.3xx
CAUTION: Use only American Standard supplied transformers and cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
Product No’.s & Options
2
Specifications
3
Faucet Installation
3
Electrical Installation
4-5
Start-up / Maintenance
6-8
FAQ’s / Troubleshooting
9
Parts
10
Certified to comply with ASME A112.18.1
© 2016 AS America, Inc.
NOTE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com or e-mail us at:
[email protected] For Parts, Service, Warranty or other Assistance, please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369) (In Toronto Area only: 1-905-306-1093) © 2016 AS America Inc.
1
M965754 (9/16)
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING
All American Standard Products Are Water Tested At Our Factory. Some Residual Water May Remain In The Valve During Shipping.
Remove the fitting and loose items from the carton. The illustration below shows all the fittings and loose items after they have been removed from the carton. Some items may be packaged partially assembled to other items.
1. Installation Instructions 2. Spout Assembly (less mixing) 2a. Spout Assembly (mixing) 3. Mounting Kit 4. 4" and 8" Deck plate (optional, must be ordered separately)
5. 6. 7. 8.
Thermostatic Mixing Valve (optional, must be ordered separately) Filter Screen Assembly Parts Battery Back-Up Unit (optional, must be ordered separately)
POWER KITS SOLD SEPARATELY PWRX Power Kit PK00.WRK
Plug-In AC Power Kit PK00.PAC
Hard-Wired AC Power Kit
Multi-AC Power Kit
PK00.HAC
PK00.MAC
2
DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE.
2a
DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE.
3
1
Inst alla tion In stru ctions
6
7
NextGen Selectronic®
Integrated Faucet with Optional Above-Deck Mixing & Temperature Limiter
MODEL NUMBERS 7755.1xx 775B.1xx 7755.2xx 775B.2xx 7755.3xx 775B.3xx
Battery Back-Up Kit
CAUTION: Use only American Standard supplied transformers and cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
Product No’.s & Options
2
8
3 Faucet Installation
3
Electrical Installation
4-5
Start-up / Maintenance
6-8
FAQ’s / Troubleshooting
9
Parts
10
© 2016 AS America, Inc.
NOTE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Selectronic ® Products visit our website at: www.americanstandard-us.com or e-mail us at:
[email protected] For Parts, Service, Warranty or other Assistance, please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369) (In Toronto Area only: 1-905-306-1093) © 2016 AS America Inc.
1
M965754 (8/16)
PK00.BBU
4
605XTMV1070 Mixing Valve
Deck Plate 775P.400
5
775P.800
2
M965754 (9/16)
Roughing-in Dimensions
Note: All plumbing and electrical wiring must be installed in accordance with applicable codes, regulations and standards.
174 mm (6-7/8") FINISHED WALL OR BACKSPLASH CLEARANCE 25mm (min) - 127mm (max) (1" min - 5" max)
39 mm (1-1/2")
146 mm 126 mm (5-3/4") (5") 125 mm (4-15/16")
61 mm (2-7/16")
48 mm (1-7/8")
38 mm (1-1/2")
CAUTION: Use only American Standard supplied transformers and cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
28 mm (1-1/8")
597 mm (23-1/2")
RECOMENDED CONTROL BOX OR EQUIVALENT BY OTHERS 4" (102mm) SQ. X 3-1/2" (89mm) DEEP CONTROL BOX Hubbel-RACO #256 OR EQUAL (BY OTHERS).
(Used with Hard-Wired AC Transformer)
3/8" COMPRESSION CONNECTORS
RECOMMENDED TOOLS 1. 2.5 mm Hex Wrench (Included) 2. Adjustable Wrench 3. Plumbers’ Putty or Caulking
1
Fig. 2
4. Phillips Screwdriver 5. Tape Measure 6. 2.0 mm Hex Wrench (Included)
SPOUT ASSEMBLY INSTALLATION; Fig. 1
CAUTION
1
3
6
2 4
5
10'
Fig. 1 IMPORTANT: Do not use putty when installing faucet without escutcheon.
Turn off hot and cold water supplies before beginning
1. Make sure O-RING (1) is installed in spout base. IMPORTANT: Do not use putty when installing faucet without escutcheon.
1
2. If installing DECK PLATE (2) (optional): Apply a bead of putty to bottom edge of PUTTY PLATE (2). Install SCREW (11) into the MOUNTING BASE OF THE FAUCET (13) and allign SCREW (11) with HOLE (12).
4 13
2 (OPTIONAL)
11
3. Insert SUPPLY HOSES (3), SHANK (4) and SENSOR CABLE (5) (only included in base model) through hole in DECK PLATE with PUTTY PLATE (2) and mounting surface.
PUTTY (If required)
12
4. Assemble RUBBER WASHER (7), BRASS WASHER (8) and THREADED LOCKNUT (9) onto SHANK (4) from underside of sink or mounting surface. Hand tighten LOCKNUT (9).
5
MOUNTING SURFACE
3
5. Use a screwdriver to tighten SCREWS (10) on LOCKNUT (9). Work your way around LOCKNUT (9), tightening the screws slightly each time until all are snug to ensure even pressure.
7 8 9
3
TIGHTEN SPIN NUTS
IMPORTANT: Do not use sealent on threads 10
M965754 (9/16)
Fig. 1
ELECTRICAL INSTALLATION
4
Product
Page 3
PWRX Power Kit (PK00.WRK)
4
Plug-In AC Power Kit (PK00.PAC)
5
Hard-Wired AC Power Kit (PK00.HAC)
5
Multi-AC Power Kit (PK00.MAC)
5
4
3
2
1
Important: All product with standard battery come with electrical connections preaseambled at the factory. No further action necessary.
A PWRX 10 YEAR BATTERY
SYSTEM; Fig. 1
BRACKET INSTALLATION
PWRK™ VERSION; 1. Connect PWRX BATTERY PACK (1) to SENSOR CABLE (2). 2. Secure the connections by installing into CONNECTOR LOCKING DEVICE (3) as shown. Rotate the END CAPS (4) to secure the connection within the CONNECTOR LOCKING DEVICE (3). 3. Determine the mounting location of the PWRX BATTERY PACK (1) by marking center lines as shown.
1 HORIZONTAL C/L
4. Place the BRACKET (5) on the horizontal center line and mark the location of the mounting holes to be drilled. 5. Using 1/4" diameter drill bit, drill two mounting holes aproximately 1" deep. 6. Install the two ANCHORS (6) provided into the mounting holes.
6 5
7. Place the BRACKET (5) over the ANCHORS (6) and secure with the SCREWS (7) provided. Do not overtighten.
VERTICAL C/L
8. Insert PWRX BATTERY PACK (1) into BRACKET (5).
4
7
M965754 (9/16)
B AC VERSIONS (HARD-WIRED /
Fig. 2
PLUG-IN POWER SUPPLY); Fig. 2
Important: Turn off power to outlet or control box.
2
10' EXTENSION
1. Connect PLUG-IN AC POWER SUPPLY (5) or 10' EXTENSION CABLE (2) if using HARD-WIRED AC TRANSFORMER (7) to SINGLE AC ADAPTER (3).
6 4
2. Connect SENSOR CABLE (4) to the other terminal of the SINGLE AC ADAPTER (3).
7
3
3. Connect PLUG-IN AC POWER SUPPLY (5) to wall outlet, or connect other end of 10' EXTENSION CABLE (2) to the HARD-WIRED AC TRANSFORMER (7).
5
1 BLACK & WHITE POWER CONNECTIONS
WALL OUTLET
FOR HARD-WIRED VERSION; 4. Make Black and White power line connections to HARD-WIRED AC TRANSFORMER (7) and mount into CONTROL BOX (6).
4" CONTROL BOX OR EQUIVALENT BY OTHERS (6)
CAUTION: Use only American Standard supplied transformers and cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
7
CONNECTOR NOT USED IN THIS INSTALLATION
Recommended Control Box or Equivalent by others 4" (102 mm) SQ. x 3-1/2" (89 mm) DEEP ELECTRICAL BOX Hubbel-RACO #256 OR EQUAL (BY CONTRACTOR).
Fig. 3
Unit #1
(Already Installed)
Unit #2
Unit #3
Unit #4
4 2
BLACK & WHITE POWER CONNECTIONS
3 1
MAXIMUM OF 15 UNITS PER TRANSFORMER. 10' MAXIMUM CABLE LENGTH BETWEEN UNITS.
C MULTI-AC VERSION (DAISY-CHAIN); Fig. 3 Important: Disconnect the first unit’s Multi-AC Adapter from power supply before making daisy-chain connections. Note: For Unit #1 electrical instructions, refer to Figure 2 (above). For subsequent Units, refer to instructions below... 1. Connect one end of the 10' EXTENSION (1) to the available terminal of the previous unit’s MULTI-AC ADAPTER (2), and the other end to the single terminal of the current unit’s MULTI-AC ADAPTER (3). 2. Connect SENSOR CABLE (4) to either of the two available terminals of MULTI-AC ADAPTER (3). 3. Repeat Steps above for each additional Unit, for a Max. of 15 Units on one AC POWER SUPPLY. 5
M965754 (9/16)
D MAKE WATER SUPPLY
Fig. 4
CONNECTIONS; Fig. 4
1. Turn off hot and cold water supplies before beginning. 2. Place each SCREEN FILTER (3) on each wall supply outlet. Be sure that SCREEN FILTER (3) is inserted in the correct direction. (See Illustration) 3. Connect HOT FLEXIBLE SUPPLY (marked with red stripe) (1) to hot water control stop (4). Connect COLD FLEXIBLE SUPPLY (marked with blue stripe) (2) to cold water control stop (5). Use adjustable wrench to tighten connections. Do not over tighten. 4. Faucet supplies are 24" long from faucet base.
2
BULGE SIDE DOWN
1 3
(3) SCREEN FILTER
5
Note; If additional supply length is required, installer must purchase those parts separately.
COLD HOT
4
Important; If SUPPLY HOSES (1, 2) are too long, loop as illustrated to avoid kinking.
IMPORTANT: Do not use sealent on threads
Fig. 5
E INSTALL OPTIONAL MIXING
VALVE; Fig. 5
Note: An optional Thermostatic Mixing Valve (sold separately) may be installed on faucets 775X.1XX & 775X.2XX in addition to Above Deck Mixing valve. See setup diagram Fig. 5.
I n s t a l l a t i o n I n s t ru c t i o n s
Optional Mixing Valve (Sold Separately)
Tee fitting is not supplied with Faucet or Thermostatic Mixing valve and must be purchased separately. If faucet inlet hoses will not reach water supplies, longer hoses must be purchased separately. For complete detailed installation and operating instructions, see installations instructions (No. M968808) supplied with Thermostatic Mixing Valve.
SELECTRONIC™ Thermostatic Mixing Valve
605XTMV
TEMPERED WATER SUPPLY
Certified to comply with ASME A112.18.1M
© 2005 American Standard
Specifications
1
Installation
2
Adjust Temperature
3
Service
3
Replacement Parts
4
M968808
COLD WATER
NOTE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S. customer's e-mail us at:
[email protected] For Parts, Service, Warranty or other Assistance, please call 1-800-442-1902 (In Canada: 1-800-387-0369) (In Toronto Area only: 1-905-3061093)
No. M968808 HOT SUPPLY
MAINTENANCE A HAND WASH SENSOR
Fig. 1
OPERATION; Fig. 1
TEE FITTING
COLD SUPPLY
TION DETECNE ZO
REMOVE PROTECTIVE FILM FROM SENSOR EYE WHEN INSTALLATION IS COMPLETE. When the Sensor detects a user, the water immediately starts to flow. Water flow will stop 1.5 seconds after user is out of sensor range. This Comfort delay allows the user to comfortably move their hands without the water turning off.
PROTECTIVE FILM
As a precaution, a Safety Timer will turn off the water, after the sensor has been blocked for 59 seconds. The water will stay off until the blockage is removed from the detection zone. The Comfort and Safety time settings can be adjusted using the Optional Remote Control (605XRCT).
6
M965754 (9/16)
B REPLACE BATTERY; Fig. 5, 7
16
15
1. Remove COVER SCREW (1) and lift COVER (15) off.
17
2. Disconnect SENSOR CABLES (6) and (7) from the BATTERY and SOLENOID VALVE. (Fig. 7) 3. Push BATTERY (17) forward and Pull it out. (Fig. 5)
2
4. Replace the new battery with the same placement. (Insert terminal side first)
12
1 4
C REPLACE SENSOR; Fig. 5, 6, 7
14
1. Remove COVER SCREW (1) and lift COVER (15) off. 2. Disconnect SENSOR CABLES (6) and (7) from the BATTERY and SOLENOID VALVE. (Fig. 7)
9
3. Remove the AERATOR RETAINER SCREW (2) and BODY FIXATION SCREW (3). (Do not remove SPOUT TUBE 16) 4. FOR ABOVE DECK MIXING FAUCETS Remove FIXATION SCREW (13). Pull the HANDLE ASSEMBLY (11) to remove the shaft from the MANIFOLD (14).
Fig. 5
5. Lift BODY (12) off of MANIFOLD (14). 6. Remove SENSOR (9) by carefully pushing on the face of the sensor. Once removed, peal the SENSOR ADHESIVE off of the BODY and clean the remaining residue. 7. To install the new SENSOR, peal the paper liner from the double sided tape and carefully place the SENSOR in its original position so that the WIRES point upward. Press and hold the sensor for 5 - 10 seconds to ensure it sticks properly.
12
Note: To prevent damage to the wires, verify that they are tucked inside the hooks which are located on both sides of the sensor. 8. FOR ABOVE DECK MIXING FAUCETS Slide SPOUT (12) over the MANIFOLD (14) being careful to avoid interference between the SPOUT TUBE (16) and SENSOR (9). Tighten the BODY FIXATION SCREW (3). Insert HANDLE ASSEMBLY (11) into the MANIFOLD (14) and secure it with FIXATION SCREW (13). Move the SPOUT TUBE (16) and AERATOR RETAINER (2) into position and tighten the AERATOR RETAINING SCREW (2) to secure the assembly. Reconnect SENSOR CABLES (6 and 7) to the BATTERY and SOLENOID VALVE. Install COVER (15) and secure it with COVER SCREW (1). Tuck extra lengths of wire in the empty space located above FIXATION SCREW (13) 9. Slide SPOUT (12) over the MANIFOLD (14) being careful to avoid interference between the SPOUT TUBE (16) and SENSOR (9). Tighten the BODY FIXATION SCREW (3). Move the SPOUT TUBE (16) and AERATOR RETAINER (2) into position and tighten the AERATOR RETAINING SCREW (2) to secure the assembly. Reconnect SENSOR CABLES (6 and 7) to the BATTERY and SOLENOID VALVE. Install COVER (15) and secure it with COVER SCREW (1). Tuck extra lengths of wire in the empty space located above FIXATION SCREW (13) 7
11
13
10 3
Fig. 6
6
7
Fig. 7 M965754 (9/16)
D CHANGE SENSOR RANGE; Fig. 5, 6, 7 1
1. Remove the COVER SCREW (1). 2. Remove the COVER (15). 3. Disconnect the BLACK POWER SUPPLY CONNECTOR (7) and reconnect. Fig. 7. 4. While the SENSOR CONTROL LED (9) is blinking slowly, place your hand 1 - 2 in. (25.4-50.8mm) in front of the sensor. 5. When the LED stops blinking and stays “ON”, move your hand to the desired position and hold in place until the LED begins to blink again. 6. Once the SENSOR CONTROL LED (9) begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set. 7. Reassemble the COVER (15) and secure it with COVER SCREW (1).
E ADJUST HOT LIMIT STOP; Fig. 12, 14 To reduce the amount of hot water that can mix with cold, the installer can adjust hot limit stop (Four different settings). 1. Rotate LEVER HANDLE (3) counter-clockwise to its stop position (100% cold). 2. Remove LEVER SCREW (5) and pull off the LEVER HANDLE (3). 3. Pull out LIMIT STOP (1) from the VALVE STEM (5). 4. Rotate LIMIT STOP (1) between the shaded area and insert back onto VALVE STEM (5). 5. Each notch on the LIMIT STOP (1) will reduce the amount of hot water by approximately 3%. For example, the 2nd notch will have 97% of maximum temp, the 3rd notch will have 94% and the fourth will be 91%. 6. Replace LEVER HANDLE (3), LEVER HANDLE SCREW (5) and tighten.
2
Fig. 12
4
F ADJUST MAXIMUM OUTLET
TEMPERATURE; Fig. 13
Fig. 13
1. With the COVER off, the installer can reduce the maximum mixed water temperature by turning the VALVE CAP (4) clockwise with a screwdriver. WARNING • Do not turn the VALVE CAP (4) More than 1 turn. • The maximum mixed water temperature can not be increased due to ASSE 1070 requirements.
G GENERAL CLEANING 1. Only use a damp, soft cloth to clean the spout and the sensor. 2. For tougher dirt, use a soft cloth with diluted dish washing detergent. Wipe the area using a wet cloth and dry using a soft cloth. CAUTION Do not scratch the sensor when cleaning. Avoid using any abrasives or harsh detergents or chemicals.
3
5 Fig. 14
8
M965754 (9/16)
TROUBLESHOOTING FLOW CHARTS UNIT DOES NOT FUNCTION ARE EXTERNAL SUPPLY STOPS OPEN?
NO
OPEN EXTERNAL SUPPLY STOPS.
YES
CRITICALLY LOW BATTERY. INSTALL NEW BATTERY.
YES REPEATED DOUBLE FLASH ON SENSOR?
NO 1 RECONNECT BATTERY TO SENSOR. DOES SENSOR FLASH FOR 5 SECONDS?
2
NO NO
1 2
DEAD BATTERY. INSTALL NEW BATTERY. REPEAT. CHECK FOR DAMAGE TO SENSOR WIRE INSULATION. REPLACE SENSOR.
YES REPLACE SOLENOID
WATER IS CONTINUOUSLY RUNNING RECONNECT BATTERY TO SENSOR. DOES SENSOR FLASH FOR 5 SECONDS?
NO
CHECK FOR DAMAGE TO SENSOR WIRE INSULATION. REPLACE SENSOR.
NO
FULLY OPEN EXTERNAL SUPPLY STOPS BY TURNING COUNTER CLOCKWISE.
YES REPLACE SOLENOID
LOW FLOW ISSUES ARE EXTERNAL SUPPLY STOPS FULLY OPEN?
YES INSPECT FILTER ASSEMBLY, AERATOR AND SOLENOID VALVE. REMOVE, CLEAN AND INSERT BACK TO ORIGINAL POSITION.
CHECK FOR BLOCKAGE
HOT LINE FOR HELP For toll-free information and answers to your questions, call: (844) CRT-TEAM / (844) 278-8326 Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 10:00 a.m. to 4:00 p.m. EST IN MEXICO 01-800-839-1200 IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093) Weekdays 8:00 a.m. to 7:00 p.m. EST
P ro d u c t n a m e s l is t e d h erei n are t rad em ark s of A S A m eri ca, I n c . ©2 0 1 6
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com or e-mail us at:
[email protected]
9
M965754 (9/16)
NextGen Selectronic®
M970210-0070A SCREW
Integrated Faucet with Optional Above-Deck Mixing & SmarTherm™ Temperature Limiter MODEL NUMBERS 7755.1xx 775B.1xx 7755.2xx 775B.2xx 7755.3xx 775B.3xx
M910297-0070A 0.35 GPM AERATOR M910290-0070A 0.5 GPM AERATOR M964171-0070A 1.5 GPM AERATOR M923155-0070A HOT LIMIT STOP M954480-0070A SOLENOID VALVE
M903708-0070A SHAFT A912746-0070A SPOUT O-RING
M924107-0070A SENSOR
M970151-0020A LEVER HANDLE
PWRX Power Kit PK00.WRK M950361-0070A PWRX BATTERY PACK M950360-0070A CONNECTOR LOCKING DEVICE
M923290-0070A HOT/COLD SUPPLY HOSES
CR-P2 Lithium Battery 7755. Series
Appropriate finish code POLISHED CHROME
M964455-0070A BRACKET
002
A923654-0070A BATTERY 6V CR-P2
M910513-0070A FILTER SCREENS (2)
Plug-In AC Power Kit PK00.PAC M950338-0070A POWER SUPPLY
775P400.002 4" ESCUTCHEON M950360-0070A CONNECTOR LOCKING DEVICE
775P800.002 8" ESCUTCHEON
M950399-0070A SINGLE AC ADAPTER
Hard-Wired AC Power Kit PK00.HAC
M962061-0070A MOUNTING KIT
M950511-0070A 10' EXTENSION M950520-0070A POWER SUPPLY
M950360-0070A CONNECTOR LOCKING DEVICE M950399-0070A SINGLE AC ADAPTER
Multi-AC Power Kit PK00.MAC
HOT LINE FOR HELP For toll-free information and answers to your questions, call: (844) CRT-TEAM / (844) 278-8326 Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 10:00 a.m. to 4:00 p.m. EST IN MEXICO 01-800-839-1200 IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093) Weekdays 8:00 a.m. to 7:00 p.m. EST
M950511-0070A 10' EXTENSION M950512-0070A MULTI-AC ADAPTER
Produ ct n ames listed herei n are t rad emark s o f A S A meri ca, Inc. ©2016
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com or e-mail us at:
[email protected]