SPECIFICATIONS Contacts
Characteristics (at 25°C 77°F, 50% R.H. seal level)
Arrangement Max. Typical Movable contact Stationary contact Max. switching power Max. switching voltage Max. switching current Mechanical 2 A 30 V DC Electrical 1 A 30 V DC (Resistive) 0.5 A 30 V DC
Initial contact resistance (By voltage drop 6 V DC 1 A) Contact material Rating, (resistive load)
Expected life (min. operations)
2 Form C, 4 Form C 50 mΩ 25 mΩ Gold-clad silver Gold-clad silver 60 W 100 VA 220 V AC, DC 2A 108 2 × 105 106 107
Max. operating speed Initial insulation resistance*1 Contact/Contact Electrostatic Contact/Coil capacitance Contact/Ground Between open contacts Initial Between contact sets breakdown Between live parts and ground voltage*2 Between contacts and coil Operate time*3 (at nominal voltage) Release time (without diode)*3 (at nominal voltage) Contact bounce
Coil Nominal operating power, at 25°C
2C 4C
Max. operating power for continuous duty
Approx. 300 mW Approx. 480 mW
Shock resistance
Approx. 1 W at 40°C 104°F
Functional*
4
In de-energized condition In energized condition
Destructive*5
Remarks
* Specif cations will vary with foreign standards certif cation ratings. *1 Measurement at same location as "Initial breakdown voltage" section *2 Detection current: 10 mA *3 Excluding contact bounce time *4 Half-wave pulse of sine wave: 11ms; detection time: 10µs *5 Half-wave pulse of sine wave: 6ms *6 Detection time: 10µs *7 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT in catalog.
Vibration resistance
Functional*6
In de-energized condition In energized condition
Destructive Conditions for operation, Ambient temp. transport and storage*7 (Not freezing and condensHumidity ing at low temperature) 2C Unit weight 4C
50 cps 1,000 MΩ at 500 V DC Approx. 4 pF Approx. 7 pF Approx. 6 pF 750 Vrms 1,000 Vrms 1,000 Vrms 1,000 Vrms Max. 15 ms (Approx. 10 ms) Max. 10 ms (Approx. 3 ms) Approx. 1.5 ms Min. 29.4 m/s2 {3 G} (In contact direction) Min. 98 m/s2 {10 G} (perpendicular to contact) Min. 196 m/s2 {20 G} Min. 980 m/s2 {100 G} 29.4 m/s2 {3 G}, 10 to 55 Hz at double amplitude of 0.5 mm (in contact direction) 98 m/s2 {10 G}10 to 55 Hz at double amplitude of 1.6 mm (perpendicular to contact) 117.6 m/s2 {12 G}10 to 55 Hz at double amplitude of 2 mm 196 m/s2 {20 G}, 10 to 55 Hz at double amplitude of 3.3 mm –40°C to + 65°C –40°F to +149°F 5 to 85%R.H. Approx. 14 g .49 oz Approx. 15.5 g .55 oz
TYPICAL APPLICATIONS NF relays are widely acceptable in applications where small size and high sensitivity are required. Such applications include: Electronic equipment, Household applications, ds_61014_en_nf: 311011J
Alarm systems, Off ce machines, Communication equipment, Measuring equipment, Remote control systems, General control circuits, Machine tools, Industrial machinery, etc. 1
ORDERING INFORMATION
NF
ORDERING INFORMATION Ex. NF
4
EB
4M
48V
1
Contact arrangement
Type classification
-
Coil voltage (DC)
2: 2 Form C˜ 4: 4 Form C
EB: Standard
-
5, 6, 12, 24, 48 V
Contact material Nil: Gold-clad silver 1: Gold-cap over silver palladium
(Notes) 1. For VDE recognized types, add suffix VDE. (Notes) 2. For UL/CSA recognized type, add suffix-A, as NF2EB-12V-A whose ground terminal is cut off.˜ (Notes) 3. Standard packing Carton: 20 pcs.; Case: 200 pcs. *Less than 1,000 Ω: ±10% *More than 1,000 Ω: ±15%
TYPES AND COIL DATA (at 25°C 77°F) Part No.
Nominal voltage, V DC
Pick-up voltage, V DC (max.)
Drop-out voltage, V DC (min.)
Max. allowable voltage, V DC (at 40°C)
Coil resistance,* Ω
Nominal operating power, mW
NF2EB-5V NF2EB-6V NF2EB-12V NF2EB-24V NF2EB-48V NF4EB-5V NF4EB-6V NF4EB-12V NF4EB-24V NF4EB-48V
5 6 12 24 48 5 6 12 24 48
4.0 4.8 9.6 19.2 38.4 4.0 4.8 9.6 19.2 38.4
0.5 0.6 1.2 2.4 4.8 0.5 0.6 1.2 2.4 4.8
8.7 10.5 21 42 84 7 8.5 17.0 34 68
90 137 500 2,000 7,000 53 90 330 1,200 4,200
278 260 290 290 330 472 400 440 480 550
Inductance, H Armarure Open Close 0.071 0.071 0.093 0.094 0.338 0.344 1.29 1.31 4.12 4.18 0.029 0.029 0.070 0.071 0.22 0.23 0.77 0.79 2.22 2.25 mm inch
DIMENSIONS 2 Form C
3.3˜ .130
1.13˜ .044
6 3 2
N.O. N.C. Ground terminal
Common terminal Coil terminal
Terminal dimensions (except soldering)˜ Width: 0.8 .031˜ Thickness: 0.3 .012
3
4 10 7 13
1.13˜ .044
N.O. N.C. Ground terminal
Common terminal Coil terminal
2.1˜ .083
1.3˜+0˜ –0.3 .051 DIA. +0˜ –.012
1.13˜ .044
9 6
(2.54)˜ (.100)
5.1±0.2˜ .2±.008
12
2 Terminal dimensions (except soldering)˜ Width: 0.8 .031˜ Thickness: 0.3 .012
General tolerance: ±0.5 ±.020 (Except for the cover height)
2
(2.54)˜ (.100) 12.7±0.2˜ 7.6±0.2˜ .5±.008 7.6±0.2˜ .3±.008 .3±.008
1
5 11 8
13.6˜24.6˜ .535 .969
Resin rise˜ max. 0.5˜ max. .020 3.3˜ .130
14
4-0.8 dia.˜ .031 dia.˜ Stand-off
Relay˜ outline
PC board pattern (Copper-side view)
Schematic
30.2˜ 1.189 20.6˜ .811
1.13˜ .044
(2.54)˜ (.100)
5.1±0.2˜ .2±.008 4.9˜ .193
4 Form C 10.8±0.3˜ .425±.012 0.3˜ .012
1.3˜+0˜ –0.3 .051 DIA. +0˜ –.012
4.9˜ .193
1 13˜ 20˜ .512 .787
Resin rise˜ max. 0.5˜ max. .020
7 4
4-0.8 dia.˜ .031 dia.˜ Stand-off
PC board pattern (Copper-side view)
Schematic
30.2˜ 1.189 20.6˜ .811
8 5
10.8±0.3˜ .425±.012 0.3˜ .012
2.1˜ .083 Relay˜ outline
(2.54)˜ (.100) 12.7±0.2˜ 7.6±0.2˜ .5±.008 7.6±0.2˜ .3±.008 .3±.008
NF REFERENCE DATA 1. Life curve
2. Coil temperature rise (resistance method)
3. H2S gas test Gas density:˜ 2 to 5 ppm˜ Temperature: 40°C˜ Humidity: 90%
1,000
30 V DC Resistive
100
50Ω Contact resistance
Coil temperature rise, °C
No. of operations, ×104
100Ω 60
40
10Ω 5Ω 1Ω
500mΩ
20
Sealed NFEB relay
100mΩ 50mΩ
10 0.5
1
1.5
2
0.2 0.4 0.6 0.8 1.0 1.2 1.4
2.5
Load current, A
4. Contact reliability Test conditions:
1. Contact current/voltage: 10 µA 100 mV 1 kHz 2. Cycle rate 20 cps. 3. Miscontact detection level: 1 mW (= 100 Ω) 4. Detection method: Observation of all changeover contacts
5. High temperature test Test conditions: Ambient temperature: 80°C ±2°C Test method:
1. All contacts were switched for 100 operations on 2 A 30 V DC resistive load. 2. Samples then were exposed to 80°C temperature for 5,000 hours, continuous 3. Contact resistance was measured with HewlettPackard testing equipment.
Test result:
Amber relays showed a stable spread of contact resistance within the initially specif ed 50 mΩ after 5,000 hours exposure.
70 Contact resistance, mΩ
F(t)(%) 99.9 99.0 95.0 90.0 80.0 60.0 70.0 50.0 40.0 30.0 25.0 20.0 15.0 10.0 5.0 4.0 3.0 2.0 1.5 1.0 0.5 0.4 0.3 0.2 0.15 0.1 0.1
20 50 100 200 1,000 500 2,000 Exposure time, hrs
Operating power, W
60 50 40 30 20
N.C. contacts
N.O. contacts
Max. Min. Max. Min.
10 0.5 1.0 5.0 10.0 50 100 No. of operations, ×106
0
100 200 300 400 500 1,000 5,000 3,000 Exposure, hrs.
Test result:
m = 1.5 µ = 21.2 × 106 95% conf dence level = 3.1 × 106 17 contacts out of 20 achieved 10 million no miscontact operations.
NOTES 1. Prevention of vibration and shock To reduce the likelihood of vibration and shock, we recommend that you install so that the contact action is not in the direction of gravity. Top Common terminal Coil terminal
NC terminal NO terminal
Bottom
For Cautions for Use, see Relay Technical Information in catalog. ds_61014_en_nf: 311011J
3