Nh3 Compliance With Unisearch Tdl

   EMBED


Share

Transcript

Cemtek Users Group 9 28 2016  New Developments in TDLAS  NH3 Monitoring Presented by John Pisano CEMTEK Environmental UCR (University of California at Riverside) Unisearch Associates Inc Cemtek Users Group 9 28 2016  Outline • • • • What is a tunable diode laser (TDL) The theory General overview of a TDL system Navigating LasIRView software – General overview – Accessing and Parsing data Cemtek Users Group 9 28 2016  What are Tunable Diode Lasers (TDL)? • Lasers made from Ga, As, Sb, P • Telecommunications grade – Long life – Rugged construction – Commercially available at low cost • Emits in near infrared region when power is  applied. Optical Light Source based Gas Analyzers Cemtek Users Group 9 28 2016  Tunable Diode Lasers (TDL) ? UNISEARCH uses TO-CAN PACKAGE OR Analyzer must be located at the measurement location 14-PIN BUTTERFLY PACKAGE Analyzer can be located far away from the measurement location Cemtek Users Group 9 28 2016  Wavelength Scale CO CO2 NH3 H2O NO2 SO2 NO SO3 O2 Near Infrared 1500 nm NIR TUNABLE DIODE LASER ABSORPTION SPECTROSCOPY Visible 700 nm Near UV 350 nm VIS-UV DIFFERENTIAL OPTICAL ABSORPTION SPECTROSCOPY Cemtek Users Group 9 28 2016  How do Tunable Diode Lasers (TDL)  Operate? • Laser center wavelength depends on material composition • Wavelength can vary based on laser temperature and current – Current: fine tune changes in wavelength (fast) – Temperature: coarse tune changes in wavelength (slow) • Laser current can be ramped rapidly – Permits the ability to rapidly scan over entire absorption spectrum • Scans the entire absorption feature – Removes interference from dust via continuous power level  monitoring Cemtek Users Group 9 28 2016  Determination of Concentration • Beer’s Law (‐Ϭ C L ) • I=Io e  – – – – – I = Energy Transmitted I0 = Energy Emitted σ = molecular cross‐section,  C = Concentration [ppm] L = Pathlength [m] • All parameters known  except for I, I0, and C. – σ unique for each molecule.  Experimentally determined. – I and I0 measured • Ideal Gas Law for  temperature and pressure  correction Cemtek Users Group 9 28 2016  Wavelength Scan (5 kHz) Radiation Power Absorption region Side wavelengths, without absorption Emission Wavelength Cemtek Users Group 9 28 2016  NIR Light Absorption When no gas present… Io When gas present… I Absorbed intensity, I = Io - I Cemtek Users Group 9 28 2016  Species Specificity with TDLs • Comes from unique molecular structure of  monitored specifies • Each species has a group of wavelengths at  which light is readily absorbed. – Ammonia: 1514 nm – HCl: ~1800 nm • Certain absorption peaks selected – Minimizes/eliminates interference due to other  compounds Cemtek Users Group 9 28 2016  Detection Limits • Factor of both path length and path  measurement time • Typical detection limit for ammonia:0.5 ppmv • Path Length – Longer path lengths yield higher absorption,  increased sensitivity and lower detection limit.  – Thus longer path lengths result in better  delectability of low concentrations. Cemtek Users Group 9 28 2016  Detection Limits • Measurement Time – Scales approximately to the square root of the  measurement time. – Example: Increasing the time from 1‐second to 1‐ min enhances the detection limit approximately  seven fold. Cemtek Users Group 9 28 2016  Multi-channel capability – single analyzer to measure multiple locations. They can be extractive, open path, in-situ stack or duct or any combination. Channels are independent with zero cross-talk between them. PORTABLE MULTI-CHANNEL ANALYZER GAS IN GAS OUT 1 - 150 m 1 2 EXTRACTIVE 1 - 75 m 10 - 500 m OPEN PATH 3 1 - 15 m 1 - 500m STACK/DUCT Cemtek Users Group 9 28 2016  TRANSMITTER OPTICS When using non fiber-coupled light source, need to locate the gas analyzer at the measurement location RECEIVER OPTICS Cemtek Users Group 9 28 2016  TRANSMITTER OPTICS GAS ANALYZER •Locate Laserthe temperature have toat bethe o measurement stabilized tolocation within +/-0.01 C • Laser temperature can be o o anywhere between 5 C to 45 C RECEIVER OPTICS Cemtek Users Group 9 28 2016  TRANSMITTER OPTICS Purge Air RECEIVER OPTICS Purge Air When using fiber-coupled light source, the analyzer can be located inside the a control room Armored Fiber Cable Coax Cable Cemtek Users Group 9 28 2016  NH3 Slip Measurements in Coal-fired Power Plants Coal-fired Power Plants Application - Ammonia slip measurement Cemtek Users Group 9 28 2016  NH3 slip measurement Cemtek Users Group 9 28 2016  NH3 slip measurement Cemtek Users Group 9 28 2016  NOX reduction in an SCR Coal-fired Boiler NH3/ Urea NOX NOX H2 O NH3 NOX Dirty Gas N2 NOX NOX NH3 NOX DeNOx Catalyst Cleaner Gas H2 O N2 NOX NOX H2 O NH3 N2 4NO  + 4NH3 2NO2 + 4NH3 4N2 + 6H2O 3N2 + 6H2O Cemtek Users Group 9 28 2016  NOX reduction in an SCR Coal‐fired Boiler NH NH33/ Urea NH3 NOX NOX H 2O NH3 NOX NH3 N2 NH3 Dirty Gas NOX NOX NH3 NOX DeNOx Catalyst N2 NH3 NOX NOX NH3 4NO  + 4NH3 2NO2 + 4NH3 4N2 + 6H2O 3N2 + 6H2O NH3 Slip H 2O H 2O NH3 N2 Cemtek Users Group 9 28 2016  In-situ NH3 measurement (Lowest Detection Limit ~0.5 ppm for a 5 meter duct diameter) Cemtek Users Group 9 28 2016  NOx Reduction in Power Plants Fiber cable Coax cable UNDER VERY HIGH DUST CONDITIONS… In-situ laser beam may not pass through the duct!!! Cemtek Users Group 9 28 2016  PIMS (Pseudo In-situ Measurement System) Cemtek Users Group 9 28 2016  Purge Control cable Cemtek Users Group 9 28 2016  Optics Heated & temperature-stabilized gas cell Optics Fiber IN Coax OUT V2  Pump TC V1  PR Filtered gas Extraction and optics enclosure Purging gas  DUCT Sampling tube Control Line IN Cemtek Users Group 9 28 2016  Sampling tube DUCT PURGE CONTROL LINE Analyzer located in Control Room COAX FIBER Cemtek Users Group 9 28 2016  NH3 Measurement in Power Plants with High Dust Loading PIMS installed in Duct Analyzer in Control Room Cemtek Users Group 9 28 2016  PIMS (Pseudo In-situ Measurement System) (China, USA, Canada, Europe, International patent pending) Cemtek Users Group 9 28 2016  EPRI PIMS Measurement at First Energy coal-fired Power Plant in US PIMS Cemtek Users Group 9 28 2016  5 4 3 2 1 Multi-point PIMS to measure NH3 inhomogeniety Cemtek Users Group 9 28 2016  Cemtek Users Group 9 28 2016  10 8 ppm 6 4 2 0 Cemtek Users Group 9 28 2016  Unisearch gas analyzer do not require field calibration. Audit Modules containing permanently sealed gas cells are available to check the validity of the measurements. Therefore, compressed gas cylinders are not required to check the performance or validity of the analyzer. Cemtek Users Group 9 28 2016  Fiber cable Audit module Coax cable Analyzer Offline Audit Cemtek Users Group 9 28 2016  Fiber cable Audit module Fiber cable Coax cable Analyzer Inline Audit  Cemtek Users Group 9 28 2016  Audit module Fiber cable GAS IN GAS OUT Gas in Fiber cable Coax cable Analyzer Inline Audit with Cylinder Gas  Cemtek Users Group 9 28 2016  Data logging: Internal compact flash card (4 GB) – can store ~5 years of data Analog: 4-20 mA outputs (for gas level and signal power) Digital: RS232 (ASCII), Ethernet, Modbus (TCP/IP) Alarms: 6 dry-contact relays (5 configurable by user) Examples: • Analyzer main power (fixed) • Software operation • Gas level alarm (low and high) • Instrument fault alarm