Preview only show first 10 pages with watermark. For full document please download

Nitra Pneumatic Solenoid Pipeline Valve Dvp-2d, Dvp

   EMBED


Share

Transcript

Prices as of April 27, 2016. Check Web site for most current prices. Process Pipeline Solenoid Valves DVP-2D & DVP-3D Series The Nitra DVP-2D and DVP-3D Series valves are composite body solenoid valves offered in both 2-way and 3-way normally closed styles in three orifice sizes. Features include a direct acting solenoid utilizing a long-life spring compensated poppet at the heart of an all stainless solenoid operator. Body construction is glass filled nylon with Viton seals, making the valves compatible with air, oil, inert gas, water and caustics*. Operating voltages of 24VDC, 24VAC or 120VAC are available. Part No. DVP-2DC1D-24D Features • 2-way and 3-way poppet style valves • 1/8, 1/4 or 3/8” FNPT ports • 2-position, normally closed, spring return • 24VDC, 24VAC or 120VAC solenoids • DIN style wiring connector Valve Symbols 2-way, 2-pos, NC DVP-2DC1D-24D DVP-2DC1D-24A DVP-2DC1D-120A DVP-2DC2E-24D DVP-2DC2E-24A DVP-2DC2E-120A DVP-2DC3F-24D DVP-2DC3F-24A DVP-2DC3F-120A DVP-2D Series Solenoid Valve Specifications $40.00 $40.00 $40.00 $40.00 $40.00 $40.00 $40.00 $40.00 $40.00 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 Model Price Weight (lbs) Valve Type Acting Port Size Orifice Size Cv Media 2-way, 2-position Poppet valve, normally closed, spring return Poppet valve, normally closed, spring return 1/8” FNPT 1/4” FNPT 3/8” FNPT 0.062” [1.6 mm] 0.094” [2.4 mm] 0.118” [3.0 mm] 0.245 0.315 0.12 Air, oil, inert gas, water, caustics* Pressure Range Voltage (앐10%) Inrush AC Power Consumption Max Freq Insulation Min Response Temperature Lubrication Protection Connection Construction Life Cycle Agency Approvals 24VDC 24VAC 50/60 Hz 120VAC 50/60 Hz 24VDC 0–250 psi [0–17.2 bar] 24VAC 50/60 Hz 120VAC 50/60 Hz 24VDC 24VAC 50/60 Hz 120VAC 50/60 Hz – 26VA – 26VA – 26VA 10W 11.5 VA 10W 11.5 VA 10W 11.5 VA 25Hz Class F (continuous duty) 16–40 ms 14°F to 122°F [-10°C to 50°C] Not Required NEMA Type 4 18mm DIN terminal Glass filled nylon body; Viton seals; Operator Stainless Steel 10 million CE * Check the chemical compatibility of the valve materials with the process media being used. Book 2 (14.3) ePN-62 Pneumatics 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices. Process Pipeline Solenoid Valves DVP-2D & DVP-3D Series Company Information Drives Soft Starters Motors Valve Symbols Power Transmission Motion: Servos and Steppers Motor Controls 3-way, 2-pos, NC 3-way, 2-pos, Mixing 3-way, 2-pos, Diverting Sensors: Proximity Sensors: Photoelectric 0.6 0.6 $40.00 $40.00 $40.00 $40.00 $40.00 $40.00 0.6 0.6 0.6 0.6 0.6 Sensors: Limit Switches Sensors: Encoders Sensors: Current Sensors: Pressure 3-way, 2-position Sensors: Temperature Poppet valve, normally closed, spring return 1/8” FNPT 1/4” FNPT 3/8” FNPT 0.062” [1.6 mm] 0.094” [2.4 mm] 0.118” [3.0 mm] 0.12 (exhaust port 0.08) 0.245 (exhaust port 0.08) 0.315 (exhaust port 0.08) Sensors: Level Air, oil, inert gas, water, caustics* 0–250 psi [0–17.2 bar] Pressure Range Voltage (앐10%) Inrush AC Power Consumption Max Freq Insulation Min Response Temperature Lubrication Protection Connection Construction Life Cycle Agency Approvals DVP-3DC3F-120A 0.6 DVP-3DC3F-24A 0.6 DVP-3DC3F-24D $40.00 DVP-3DC2E-120A $40.00 DVP-3DC2E-24A $40.00 DVP-3DC2E-24D DVP-3DC1D-120A Price Weight (lbs) Valve Type Acting Port Size Orifice Size Cv Media DVP-3DC1D-24A Model DVP-3DC1D-24D DVP-3D Series Solenoid Valve Specifications 24VDC 24VAC 50/60 Hz 1–150 psi [0–10.3 bar] 120VAC 50/60 Hz 24VDC 24VAC 50/60 Hz 1–110 psi [0–7.6 bar] 120VAC 50/60 Hz 24VDC Sensors: Flow Pushbuttons and Lights 24VAC 50/60 Hz 120VAC 50/60 Hz – 26VA – 26VA – 26VA 10W 11.5 VA 10W 11.5 VA 10W 11.5 VA 25Hz Stacklights Signal Devices Process Class F (continuous duty) 16–40 ms Relays and Timers 14°F to 122°F [-10°C to 50°C] Pneumatics Not Required Pneumatics: Directional Control Valves NEMA Type 4 18mm DIN terminal Pneumatics: Cylinders Glass filled nylon body; Viton seals; Operator Brass 10 million Pneumatics: Tubing CE Pneumatics: Air Fittings Appendix Book 2 * Check the chemical compatibility of the valve materials with the process media being used. Terms and Conditions Book 2 (14.3) www.automationdirect.com/pneumatic-parts Pneumatics ePN-63 Prices as of April 27, 2016. Check Web site for most current prices. Process Pipeline Solenoid Valves DVP-2D & DVP-3D Series Dimensions inches [mm] See our website www.AutomationDirect.com for complete Engineering drawings. Book 2 (14.3) ePN-64 Pneumatics 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices. Solenoid Valve Cables and Connectors These high quality connectors and over-molded cables help reduce wiring time. The lower voltage models, 24V or 110V AC/DC, include built-in surge suppression, Yellow LED indicator and are rated for connecting with electronics. The 230V AC/DC models are rated for straight wired products. All models are available in five sizes based on DIN 43650. Features • 8mm, 9.4mm, 10mm, 11mm and 18mm square DIN styles • Fits most popular solenoid valves and sensors • Suppression and LED indication available in 24V or 110V AC/DC models • PVC jacketed cables in 1, 3 or 5 meter lengths on select connectors • Field wireable connectors on select models • Polarity insensitive (follow solenoid, sensor, or other devices wiring diagram) 8mm Connectors Dimensions shown mm [inches] Height = 26mm [1.02] Height = 25mm [0.98in] Field Wireable Connector Connector with Cable 8mm (3-pole) Connectors (per DIN 43650 Form C) Voltage Current IP Price (AC/DC) Rating Rating Part No. SC8-LS24-3 SC8-LS24-5 SC8-LS110-3 SC8-LS110-5 SC8-3 $11.00 SC8-0 $5.00 SC8-1 SC8-5 $12.00 $13.00 $13.50 $16.00 Wire Size Cable Dia. (in.) LED Surge Protection Wiring Screw Size/ Weight Agency Figure Torque (lbs) Approval zener diode (D-Z DO-15 47V 2W) 24 ±20% max 4A 67 110 ±10% 18 AWG 0.23 1 yes zener diode (D-Z DO-41 ZY200 2W) 7 $9.75 m2.50.45x25mm/ 0.4 Nm (3.5 in lb) 230 Solid 12 AWG gland size Stranded 14 AWG 0.20 to 0.24 w/Ferrule 16 AWG max 6A $9.75 67 18 AWG no 9 none 0.23 0.65 0.41 CSA (080128-0000) 0.63 0.39 2 65 0.40 m2.50.45x25mm/ 0.5 Nm (4.4 in lb) 2 0.10 none 0.10 0.68 Please note: The above parts are not compatible with the AVP and AVS series valves, which have 11mm DIN plugs. Last digit in part number denotes cable length in meters, a 0 indicates field termination. 8mm Transmitter Connector Dimensions shown mm [inches] Height = 25mm [0.98in] Connector with Cable 8mm (4-pole) Connectors (per DIN 43650 Form C) Part No. Price Voltage (AC/DC) SC8-5T $17.00 230 Current Rating IP Rating Wire Size max 6A 67 18 AWG Cable Dia. LED Surge Wiring Screw Size/ Weight Agency (in.) Protection Figure Torque (lbs) Approval 0.26 yes none 8 m3-0.5x42mm/ 0.5 Nm (4.4 in lb) 0.80 CSA (0801280-000) Last digit in part number denotes cable length in meters, a 0 indicates field termination. Book 2 (14.3) ePN-68 Pneumatics 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices. Solenoid Valve Cables and Connectors Company Information Drives Soft Starters 9.4mm Connectors Motors Dimensions shown mm [inches] Power Transmission Motion: Servos and Steppers Motor Controls Height = 25mm [0.98in] Connector with Cable Sensors: Proximity 9.4mm (3-pole) Connectors (DIN Style, Form C Industrial) Part No. Price SC9-LS24-3 SC9-LS24-5 SC9-LS110-3 SC9-LS110-5 SC9-3 $11.00 SC9-5 $13.00 $13.50 $16.00 Voltage Current IP Wire Cable Wiring Screw Size/ Weight Agency (AC/DC) Rating Rating Size Dia. (in.) LED Surge Protection Figure Torque (lbs) Approval zener diode (D-Z DO-15 47V 2W) 1 zener diode (D-Z DO-41 ZY200 2W) 7 none 2 24 ±20% max 4A 110 ±10% 0.40 m3-0.5x26mm/ 0.4 Nm (3.5 in lb) yes 67 18 AWG 0.23 $12.00 max 6A no 0.40 CSA (0801280-000) 0.64 m3-0.5x26mm/ 0.5 Nm (4.4 in lb) $9.75 230 0.64 0.40 0.64 none Sensors: Photoelectric Sensors: Limit Switches Sensors: Encoders Sensors: Current Sensors: Pressure Please note: The above parts are not compatible with the AVP and AVS series valves, which have 11mm DIN plugs. Last digit in part number denotes cable length in meters. Sensors: Temperature 10mm Connectors Dimensions shown mm [inches] Sensors: Level Sensors: Flow Pushbuttons and Lights Height = 30mm [1.18in] Height = 41mm [1.61in] Connector with Cable Field Wireable Connector Stacklights Signal Devices 10mm (3-pole) Connectors (per DIN 43650 Form B) Part No. SC10-LS24-3 SC10-LS24-5 SC10-LS110-3 SC10-LS110-5 SC10-3 SC10-5 SC10-LS24-0 Voltage Current IP Cable Wiring Screw Size/ Weight Agency Price (AC/DC) Rating Rating Wire Size Dia. (in.) LED Surge Protection Figure Torque (lbs) Approval $11.00 $13.00 $13.50 $16.00 $9.75 $12.00 $9.50 24 ±20% (D-Z DO-15 47V 2W) 110 ±10% 230 max 1A 18 AWG zener diode 0.23 (D-Z DO-41 ZY200 2W) max 10A max 4A SC10-LS110-0 $10.00 110 ±10% max 1A SC10-0 max 10A 230 67 no 65 Solid 12 AWG Stranded 14 AWG w/Ferrule 16 AWG none zener diode gland size 0.24 to 0.32 yes (D-Z DO-15 47V 2W) mov (SIOV S10 K130) no none 0.43 10 yes 24 ±20% $7.50 zener diode max 4A 6 0.68 m3-0.5x30mm/ 0.4 Nm (3.5 in lb) 0.68 m3-0.5x42mm/ 0.5 Nm (4.4 in lb) 0.07 Pneumatics: Directional Control Valves Pneumatics: Cylinders 0.07 4 9 0.68 Relays and Timers Pneumatics CSA (080128-0-000) 0.43 3 5 0.43 Process none 0.06 Pneumatics: Tubing Pneumatics: Air Fittings Please note: The above parts are not compatible with the AVP and AVS series valves, which have 11mm DIN plugs. Last digit in part number denotes cable length in meters, a 0 indicates field termination. Appendix Book 2 Terms and Conditions Book 2 (14.3) www.automationdirect.com/pneumatic-parts Pneumatics ePN-69 Prices as of April 27, 2016. Check Web site for most current prices. Solenoid Valve Cables and Connectors 11mm Connectors Dimensions shown mm [inches] Height = 30mm [1.18in] Height = 30mm [1.18in] Connector with Cable Height = 41mm [1.61in] Reverse Connector with Cable Field Wireable Connector 11mm (3-pole) Connectors (DIN Style, Form B Industrial) Part No. SC11-LS24-3 SC11-LS24-5 SC11-LS110-3 SC11-LS110-5 SC11-LS24-3R SC11-LS24-5R SC11-LS110-3R SC11-LS110-5R SC11-3 SC11-5 Voltage Current IP Price (AC/DC) Rating Rating $11.00 24 ±20% $13.00 $13.50 110 ±10% $16.00 Cable Dia. (in) LED Surge Protection Wiring Screw Size/ Weight Agency Figure Torque (lbs) Approval zener diode (D-Z DO-15 47V 2W) max 4A zener diode (D-Z DO-41 ZY200 2W) max 1A 24 ±20% $13.00 $13.50 110 ±10% $16.00 $9.75 230 $12.00 $9.50 24 ±20% max 4A 67 18 AWG no $10.00 110 ±10% max 1A SC11-0 $7.50 230 max 10A none 65 Solid 12 AWG gland size Stranded 14 AWG 0.24 to 0.32 w/Ferrule 16 AWG yes no 4 (D-Z DO-15 47V 2W) mov (SIOV S10 K130) 5 none 0.44 0.67 CSA (080128-0000) 0.44 0.67 0.44 3 zener diode max 4A 0.67 m3-0.5x30mm/ 0.4 Nm (3.5 in lb) 6 (D-Z DO-41 ZY200 2W) max 10A SC11-LS110-0 10 zener diode max 1A 0.67 0.44 6 zener diode (D-Z DO-15 47V 2W) 0.23 0.44 10 yes $11.00 SC11-LS24-0 Wire Size 0.67 m3-0.5x42mm/ 0.5 Nm (4.4 in lb) 9 0.07 0.07 none 0.07 Last digit in part number denotes cable length in meters, a 0 indicates field termination. 18mm Connectors Dimensions shown mm [inches] Height = 41mm [1.61in] Height = 30mm [1.18in] Field Wireable Connector Connector with Cable 18mm (3-pole) Connectors (per DIN 43650 Form A) Part No. Voltage Current IP Price (AC/DC) Rating Rating SC18-LS24-3 $11.00 SC18-LS24-5 $13.00 SC18-LS110-3 $13.50 SC18-LS110-5 $16.00 SC18-3 $9.75 SC18-5 $12.00 SC18-LS24-0 $9.50 24 ±20% Wire Size Cable Dia. (in) LED Surge Protection 7 yes max 1A 230 max 10A 24 ±20% 67 18 AWG zener diode (D-Z DO-41 ZY200 2W) 0.23 no $10.00 110 ±10% max 1A SC18-0 $7.50 230 max 10A none zener diode max 4A SC18-LS110-0 0.44 zener diode (D-Z DO-15 47V 2W) max 4A 110 ±10% Wiring Screw Size/ Weight Agency Figure Torque (lbs) Approval 65 Solid 12 AWG gland size Stranded 14 AWG 0.24 to 0.32 w/Ferrule 16 AWG yes no (D-Z DO-15 47V 2W) 0.69 m3-0.5x30mm/ 0.4 Nm (3.5 in lb) 0.69 0.07 4 5 none 9 0.69 CSA (080128-0000) 0.44 2 mov (SIOV S10 K130) 0.44 m3-0.5x42mm/ 0.5 Nm (4.4 in lb) 0.07 none 0.07 Please note: The above parts are not compatible with the AVP and AVS series valves, which have 11mm DIN plugs. Last digit in part number denotes cable length in meters, a 0 indicates field termination. Book 2 (14.3) ePN-70 Pneumatics 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices. Solenoid Valve Cables and Connectors Wiring Diagrams Company Information Drives Soft Starters Motors 1 black 1 1 black 1 1 black 1 Power Transmission black 2 green/yellow 2 black 2 2 black 2 Motion: Servos and Steppers yellow 2 green/yellow Figure No. 1 green/yellow Figure No. 2 Motor Controls Sensors: Proximity Figure No. 3 Sensors: Photoelectric 1 1 1 1 yellow yellow 1 U 2 2 Sensors: Limit Switches black 1 Sensors: Encoders yellow 2 2 Sensors: Current black 2 2 green/yellow Figure No. 4 Figure No. 5 Sensors: Pressure Figure No. 6 Sensors: Temperature 1 black 1 yellow 2 black 2 green/yellow 1 black 1 2 black 2 3 black 3 1 Sensors: Level 1 Sensors: Flow 2 Pushbuttons and Lights 2 green/yellow Stacklights Figure No. 7 Figure No. 8 Figure No. 9 Signal Devices Process 1 Relays and Timers black 1 Pneumatics yellow 2 Pneumatics: Directional Control Valves black 2 green/yellow Pneumatics: Cylinders Figure No. 10 Pneumatics: Tubing Pneumatics: Air Fittings Appendix Book 2 Terms and Conditions Book 2 (14.3) www.automationdirect.com/pneumatic-parts Pneumatics ePN-71