Preview only show first 10 pages with watermark. For full document please download

Nmt100-im-yg

   EMBED


Share

Transcript

YoungerUSA - 9 Research Drive, Suite 5 Amherst, MA 01002 Phone: 413-992-2003 - Email: [email protected] NMT100-IM-YG Product Code: NMT100-IM-YG Short Description Fully computerized system that provides fast, convenient, multi-dimensional and realtime measurement without damaging the samples. To be used with samples with a diameter between 5µm and 10cm. Detects: 1 ion or 1 molecule at a time Description The NMT100-IM-YG is one in a series of fully computerized systems that provide fast, convenient, multi-dimensional and real-time measurement without damaging the samples. NMT uses ion-selective microelectrodes to measure the concentration, flux, and direction of selected ions and/or molecules as they go in and come out of living samples without touching them. By using multiple electrodes simultaneously, NMT detects the flux information and the PH of a single ion or molecule, while simultaneously collecting the activity information of multiple ions, molecules, and their parameters. The system can measure samples such as single cells, tissues, and organs. Sample size: between 5µm and 10cm in diameter Detects: one ion or one molecule at one time NMT100 Series (applicable to samples with a diameter between 5µm and 10cm) NMT100-I-YG Measures the signal of one ion at a time NMT100-IM-YG Measures the signal of one ion or one molecule at a time The signal of one ion and one molecule can be measured individually NMT100-SIM-YG Two signals can be measured simultaneously (“ion + ion” and “ion + molecule”) Features In-situ and non-invasive test on living samples Real-time Testing Ionic and molecular measurements or dual-electrode measurements Long-term measurements No labeling Multiple measurements High resolution and wide measurement scope No need of extracting samples Capable of testing various samples 3D Flux Measurements Measurable Samples To be used with samples with a diameter between 5µm and 10cm Specifications Motion Control Module ? X-axis Motion Translation Stage Load Capacity 156N Travel distance 25.4mm Mode Automatic Control Stepper motor Minimum step 39nm Bidirectional repeatability 500nm Motion Control Module ? Y-axis Motion Translation Stage Load Capacity 156N Travel distance 25.4mm Mode Automatic Control Stepper motor Minimum step 39nm Bidirectional repeatability 500nm Motion Control Module ? Z-axis Motion Translation Stage Load Capacity 191N Travel distance 46mm Mode Manual Control Lead screw drive Motion Control Module ? Lead screws Screw Thread 1/4-100 Load Capacity 90N Travel distance 25mm Motion Control Module ? Supporting Stage Dimensions L200mm×W200 mm×H5mm Material-top M6 on 25mm Adjustable supporting rod 150mm - 250mm Motion Control Module ? Motion Control Mechanical Settings Minimum step 39 nm Bidirectional repeatability 500 nm Motion Control Module ? Polarographic Controller Polarized voltage output 0 - ±1.999V range Accuracy ±1.000mV Motion Control Module ? Flexible Coupling Size 11×6×23mm Clockwise & counter yes clockwise rotation characteristics of the same Stainless steel ring X2 Mini screw hole X2 Signal Processing Module ? Pre-amplifier (Ionic Head Stages) Input impedance: 10T? Minimum gains ×10 Signal Processing Module ? Pre-amplifier (Polarographical Head Stages) Type embedded current/voltage conversion Resolution 1mV/pA Signal Processing Module ? Solid Reference Microelectrode Temperature range -5°C to 100°C Wire length 2m Tip diameter 2 mm Signal Processing Module ? Glass Microsensor Holder Size 25 mm×10 mm Ag/AgCL wire 50 mm×0.2 mm Signal Processing Module ? Reference Microelectrode Holder Rotation angle 360° Linear Motion adjustable solid sliding rail Signal Processing Module ? Ground Wire Bracket Size 80mm×20mm×30mm Signal Processing Module ? Data Acquisition System Signal Acquisition mode 16 bits A/D conversion card Software module(s) Ion measurement software module; Molecule measurement software module Operating system Windows7 Signal Processing Module ? High-gain Main Amplifier for Ion/Molecule Sensor Polarized voltage output 0 - ±0.999V range Ion channel number 1 Molecule channel number 1 Input voltage & frequency 100-240 VAC 50/60 Hz Accuracy ±1.000mV Amplifier gains ×100 Image Acquisition Module ? Microscopic Lighting Control Image sensor 1/2.5” Ocular Lens 10×?field of view: 20 mm Maximum Resolution 3264×2448 Signal-to-noise ratio 34dB Magnification range 40× - 400× Objective Lens 4×, 10×, 20×, 40× Pixels 8,000,000 White balance Automatic/manual CCD Lens Adapter can be connected to a CCD camera Focus System coarse micro coaxial focusing system, trimming each circle 0.2mm, Lattice valued 0.002mm, coarse with elastic adjustment, and the upper limit of focusing device Functions image capture, video recording, image processing Objective localization of five port converter Stage mechanical stage XY to move the regulating hand wheel, moving range of 120×80mm Interface USB2.0 Trinocular Microscope yes Image Acquisition Module ? Video Converter Image resolution 1920×1200 DVI output 2 Software ? Non-invasive Ion & Molecule Flux Measurement Software V2.0 Manual English Interface English/Chinese Software module(s) Ion/Molecule measurement module Data output format MS Excel Account Management Multi user Supports Chinese input yes Potential/Slope value over yes range alarm module Data optimization module yes Software (Optional) ? NMT Data Analysis Software V1.2 Supports data format txt Can complete sample yes ion/molecule flux data 3D drawing Supports flux data 3D yes graphics output and dynamic demonstration Accessories ? Manual Manual English/Chinese Accessories ? Selective Ion Sensor Making Station Bright-field dual-ocular WF10X Objective Lens 4X, 10X, 40X Stage size 40mm×40mm Travel distance 13mm Accuracy 3µm/1.5µm LIX filling length for 1 - 2 µm accurate control Rubber tube inner 1.5mm diameter Accessories ? Chloriding Setup Power supply 9V Height adjusting range 5cm Platinum filament length 3cm Chloride container 3cm diameter Accessories (Optional) ? Monitor for Sample Viewing inside Faraday Cage Backlight LED Interface type VGA Resolution 1024×768 Contrast 1000:1 Size 12 inch Product Gallery Powered by TCPDF (www.tcpdf.org)