Novelties Implemented In The Latest Version Of Fw For Mi 2892

   EMBED


Share

Transcript

Novelties implemented in the latest version of FW for MI 2892 (1.0.2061) 1. Connection check provides the user quick information about appropriateness of connected clamps and voltage leads. In this menu user can setup connection parameters, such as nominal voltage, frequency, etc. After all parameters are provided, instrument is checking if given parameters complies with measured results. In case of incompatibility instrument will report Connection check issue before leaving this screen. 2. Clamps selection menu enables the user to choose several predefined clamps, or none in case of measuring only voltage. Under default Smart clamps /T menu the user can also chose Primary and Secondary current when performing measurements on substation. 3. Measurements menu enables additional UNDER/OVER DEVIATION menu. Voltage Underdeviation (UUnder) and Overdeviation (UOver) measurement method: Standard compliance: IEC 61000-4-30 Class A (Section 5.12). Basic measurement for the Underdeviation and Overdeviation is RMS voltage magnitude measured over a 10/12-cycle time interval. Page 1 1. General recorder menu enables better manipulation on INCLUDE EVENTS/INCLUDE ALARMS submenu the user can additionally select option to record (EVENTS/ALARMS) with waveforms. General recorder also includes Signalling parameters, plus additional quick buttons to enter CONFIG and CONNECTION CHECK menus. 2. Waveform recorder menu includes several HELP menus explaining different triggering options. 3. EVENT SETUP menu includes several HELP menus explaining different triggering options. Page 2 4. RVC SETUP Rapid Voltage Changes (RVC) A rapid voltage change is a quick transition in r.m.s. voltage between two steady-state conditions. To measure rapid voltage changes, thresholds may be defined for each of the following: the minimum rate of change, the minimum duration of the steady-state conditions, the minimum difference in voltage between the two steady state conditions, the maximum voltage change during the transition period (voltage change characteristic) and the steadiness of the steadystate conditions. The voltage during a rapid voltage change shall not exceed the voltage dip and/or the voltage swell threshold, as it would otherwise be considered as a voltage dip or swell. The characteristic parameter of the rapid voltage change is the difference between the steadystate value reached after the change and the initial steady-state value. Page 3