Preview only show first 10 pages with watermark. For full document please download

Np18pr18sl18 Wall Mount Range Hood Specifications - Vent-a-hood

   EMBED


Share

Transcript

WALL MOUNT RANGE HOOD SPECIFICATIONS       NPH18/NPXH18/PRH18/PRXH18/SLH18/SLXH18 Equipped with LED lighting. WBAR warming light bar is available on selected models. X in part number indicates 27” depth.        NPH18/NPXH18  PRH18/PRXH18 SLH18/SLXH18 Connection Diagrams (30” - 48” Widths) 5 ¼” 1 ¾” 1 3⁄8” Wall Side 5 ½” Wall Side Vent Hole Electrical 3 ¼” Recommended Mounting Height* 5 ¼” Vent Holes 1 ¾” 6” Outlet                                                         8” Outlet Electrical Centerline of Hood Centerline of Hood 300 CFM B100 Single Blower 600 CFM B200 Dual Blower (Top View) (Top View) Connection Diagram (42” - 60" Widths) 7 5⁄16” 5 ½” Wall Side 10” Round 7 5⁄16” 10” Round 1 ¾” 1 7⁄8” Vent Holes 17 ½” Electrical (2) 5 ¼” Centerline of Hood 8” Outlet 6” Outlet 8” Round 8” Round 6” Round 2” 900 CFM B200 Dual & B100 Single Blower (Top View) VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower) Connection Diagram (48” - 66" Widths) 11” 11” 5 ½” 12” Round 5 ½” 12” Round 16 ½” 8” Outlet 5 ¼” 8” Outlet VP562: 10” VP563: 12” Wall Side Vent Holes 1 ¾” Centerline of Hood Electrical (2) 8” Round 8” Round 8” Round 3” 1200 CFM Double B200 Dual Blowers (Top View) VP563 Transition (Optional) For B400 (Double B200 Dual Blowers) Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals *Recommended mounting height is for optimum performance. Volts Amps* Hz RPM 115 115 115 115 2.5 4.0 6.0 7.5 60 60 60 60 1550 1550 1550 1550 VP562/VP563 transition centers outlet over top of hood CFM CFM CFM CFM Minimum Round • [email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]" Duct Size 300 450 273 245 225 6" (28 in.2) 600 900 531 480 430 8" (50 in.2) 900 1350 804 725 655 VP562: 10" (79 in.2) 1200 1800 1062 960 860 VP563: 12" (113 in.2) Sones# 5.4 6.5 6.3 6.6 * Add 2.5 amp for each warming light. Hood is available with LED lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0516A C UL R US