ABOUT NIVOPRESS NIVOPRESS N submersible hydrostatic level transmitter consists of a special breathing cable (containing capillary tube and stress resistant inlet) and a probe. There are two different designs of the stainless steel probe: with ceramic flush diaphragm and stainless steel diaphragm behind a plastic protection cap. The level metering is based on the measuring of the pressure difference between the hydrostatic pressure of the liquid head over the diaphragm and the actual atmospheric pressure. This pressure difference is converted into 4 … 20 mA current in the 2-wire version and 0 … 10 V DC voltage in the 4 - wire version. Easy installation and wiring is ensured by the use of the complete set of accessories. For outdoor measurements the application of over voltage protection (OVP) is suggested. To ease installation the use of terminal box (with or without OVP) is recommended serving as terminal for the wires and for the breathing tube. The settings of a HART capable instrument can be reprogrammed by the user in case if the application's conditions alter. For some types with HART communication the pressure and temperature values can be accessed through different addresses. The user can recalibrate the instrument if it is needed.
Remote programming HART communication 4–20 mA output 0.25% accuracy Wide range of measurement Level gauge for wells, basins reservoirs Also for mildly aggressive mediums Pt100 sensor Temperature transmitter 3 point calibration Internal or flush diaphragm Vapour filter on the transmitter Surge and polarity protection
APPLICATION Cable fastening
Terminal box
4 ... 20 mA
Site
Over voltage protection
Indicator power supply
UT
Control room
CABLE HOLDING ACCESSORIES Serves for fastening the probe in two versions: NAA-209 type: provides a solution for hanging the cable without slipping and risk of rupture. NAA-105 type: cable holding assy that can be fixed to the ceiling. CABLE TERMINAL BOX The NAA-101/102 plastic cable terminal box is to be used for cable extension. The box allows connection and grounding of the shielded cables of the probe. The NAA-102 box comes with built-in OVP 12/33 overvoltage protection unit. OVERVOLTAGE PROTECTION The OVP 12/33 unit protects the site instrument while the OVP 32/33 unit protects the signal processing unit in the control room.
TECHNICAL DATA TYPE
NCK-200
NCH-200
NH-400
0 … 200 m 0 … 200 m 0 … 20 m w.h. w.h. w.h. In accordance with the order code 20x (h≤ 3 m w.h.) 3x 3x 10x (> 3 m w.h.) 2-wire 4 … 20 mA 3-wire 0… 10V (0V≤80mV) HART ProgrammRtmin=250 ohm able 12 … 30 V 9 … 30 V DC 18 … 30 V DC DC
Range Maximum pressure as the multiplied range Output signal Power supply Maximum resistance Us = voltage of p. source Umin =. min. voltage Power consumption Temperature sensor Temperature transmitter Accuracy Temperature coefficient Temperature range* Storage temperature Ingress protection Electrical protection Electrical connection Cable cross section Approval Cable length Mass Material of wetted parts
ACCESSORIES NP-400 NZ-400
Diaphragm Housing Cable coat Gasket Protection cap
Rt =
(U t − Umin ) 0,02A
NAA-101 *
Dimension Ingress protection Ambient temperature Material Conduit Electric connection
93 x 93 x 55 mm IP 65 –40 °C … +70 °C Polystyrol M20x1,5 cable outer diameter ∅5… ∅10 mm Terminal screw (max. 2.5 mm2-es cross section)
CABLE TERMINAL BOX WITH SURGE PROTECTION General data
< 6 mA
Electric data
Same as with OVP
CABLE FASTENING
NAA-209 / NAA-105 300 m / 100 m -10 °C … + 45 °C 200 x 62mm / 110 x 110mm
SURGE PROTECTION
± 0,25 % ≤ ± 0.1 % / 10K ≤ ± 0.2 %/ 10 K - 10 °C…+60 ° * -10 °C … +50 °C IP 68 Class III. Shielded, breathing cable ∅ 7 mm 0.34 mm2 Only NP and NZ types: II 1 G EEx ia IIC T6 0 … 300 m in accordance with the order code Probe 0.2kg Probe 0.4 kg Probe 0.2 kg Cable: ∼ 0.06 kg/m 1.4404 Al2O3 ceramic 1.4404 1.4571 1.4404 1.4571 Polyurethane FKM ABS – ABS
NAA-102 *
Same as with NAA-101
Maximum cable length Ambient temperature Dimension
≥ 5 kohm
— Pt100 class B -10…+60°C range
CABLE TERMINAL BOX
OVP12/33 *
Version Dimension Ingress protection Electrical connection Voltage clipping Pulse power Input resistance Leakage current
OVP32/33 *
Open air DIN 35 mm rail mounted 72 x 42 x 19 mm 62 x 70 x 18 mm IP 54 IP 20 max. 2.5 mm2 wire cross section 33 V 600 W / 1 ms 13 ohm ≤ 10 µA
* For 4 … 20 mA loop powered units only
ACCESSORIES
* On special order – 10 °C … +75 °C
139
119
DIMENSIONS
NAA-101 / NAA-102 cable terminal box
Ø7
NAA-209 cable holding wedge clamp
170
Ø7 Ø 22
Ø38
62
16
70
191
140
Ø 22
¾” BSP 1 1/2" BSP
40
NP-400
NCK-200, NCH-200
NAA-105 cable holding assy
NZ-400
OVP 32 / 33 overvoltage protection unit
ORDER CODE (Not all combinations possible) NIVOPRESS N
TYPE Capacitance Piezo Piezo threaded
**
CODE OUTPUT CODE VERSION CODE RANGE*** Normal C* 2-wire 4...20 mA K 2 1 m w.h. P 3-wire 0...10 V H* 4 Normal 2 m w.h. 2x 4..20mA lev. + temp. D Ex 5 m w.h. Z 5 10 m w.h. 4..20mA + Pt100 P 20 m w.h. * Only types without HART 50 m w.h. ** The order code of an Ex version should end in “Ex” *** Can be set whitin the range on special request 100 m w.h. 200 m w.h.
NIVELCO PROCESS CONTROL CO. H - 1 0 4 3 B U D A P E S T, D U G O N I C S U . 11 . PHONE:(36-1) 889-0100 FAX:(36-1) 889-0200 e-mail:
[email protected] www.nivelco.com
CODE CABLE LENGTHCODE 1 0m 0 10 m 2 1 : 3 : 90 m 9 4 5 100 m A 200 m 6 B 300 m 7 C 8
CABLE LENGTHCODE 0m 0 1 : 9m 9 0m 0 10 m 1 : : 90 m 9
001 1m to up : m 0 01 re ov
Nivelco reserves the right to change technical data withou notice!