Preview only show first 10 pages with watermark. For full document please download

Npn/m-7055(d)

   EMBED


Share

Transcript

I-7000 and M-7000 Modules  Features  I-7055(D)/M-7055(D)  Source-type Digital Output Channels with Overload Protection  I-7055(D)-NPN/M-7055(D)-NPN  Sink-type Digital Output Channels with Overload 2 I-7055(D) 3 Protection M-7055(D)  All Digital Input Channels can be used as 16-bit Counters  Short Circuit Protection RS-485 Remote I/O Modules  4 kV ESD Protection  3750 VDC Intra-module Isolation  Configurable Power-on Value Settings  Configurable Safe Value Settings I-7055(D)-NPN 8-channel Isolated Digital Input and 8-channel Isolated Digital Output Module  Introduction The I-7055 offers 8 isolated channels for digital input and 8 isolated channels for digital output. Either sink-type or source-type digital input can be selected via wire connections. All digital input channels are also able to be used as 16-bit counters. The I-7055 supports source-type output with short circuit protection.  System Specifications Model I-7055 I-7055D I-7055-NPN I-7055D-NPN M-7055 M-7055D M-7055-NPN M-7055D-NPN Communication Interface RS-485 Bias Resistor No (Usually supplied by the RS-485 Master. Alternatively, add a tM-SG4 or SG-785.) Format N, 8, 1 Baud Rate 1200 to 115200 bps Protocol Dual Watchdog DCON (For I-7055 series) System LED Indicator Yes, Module (1.6 Seconds), Communication (Programmable) I-7055(D)/I-7055(D)-NPN/M-7055(D)/M-7055(D)-NPN I/O LED Indicators 7-segment LED Display Yes, 1 as Power/Communication Indicator Yes, 8 LEDs as Digital Input & 8 LEDs as Digital Output Indicators -  Applications Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote Diagnosis, Testing Equipment. I-7055 I-7055D I-7055-NPN I-7055D-NPN Model M-7055 M-7055D M-7055-NPN M-7055D-NPN Digital Input/Counter Channels - Yes, 8 LEDs as Digital Input & 8 LEDs as Digital Output Indicators Type Wet Contact 8 Dry Contact Source Wet Contact Sink/Source ON Voltage Level +10 ~ 50 VDC OFF Voltage Level +4 VDC Max. ON Voltage Level Dry Contact - Isolation Intra-module Isolation, Field-to-Logic There are options to enable both power-on and safe values. The I-7055D has 16 LED indicators that can be used to monitor the status of the digital input and digital output channels. 4 kV ESD protection and 3750 VDC intra-module isolation are standard. The M-7055 has the same hardware specifications as the I-7055, but provides additional support for the Modbus RTU protocol as well as the DCON protocol.  I/O Specifications Modbus RTU, DCON (For M-7055 series) LED Indicators/Display 1  Wide Operating Temperature Range: -25 to +75°C M-7055(D)-NPN 3750 VDC EMS Protection Counters Close to GND OFF Voltage Level Open Effective Distance for Dry Contact 500 m Max. Max. Count 65535 (16-bit) Max. Input Frequency 100 Hz Min. Pulse Width 5 ms ESD (IEC 61000-4-2) ±4 kV Contact for each Terminal ±8 kV Air for Random Point EFT (IEC 61000-4-4) ±4 kV for Power Line Input Impedance 10 kΩ Surge (IEC 61000-4-5) ±3 kV for Power Line Channel-to-Channel Isolation - Power Overvoltage Protection ±70 VDC Reverse Polarity Protection Yes Digital Output Input Range +10 ~ +30 VDC Consumption 0.8 W 1.6 W 1.2 W Mechanical 2.2 W Channels 8 Type Open Source Open Collector Sink/Source (NPN/PNP) Source Sink +3.5 ~ 50 VDC Dimensions (L x W x H) 123 mm x 72 mm x 35 mm Load Voltage +10 ~ 40 VDC Installation DIN-Rail or Wall Mounting Max. Load Current 650 mA/Channel 700 mA/Channel Overvoltage Protection 47 VDC 60 VDC Environment Operating Temperature -25 to +75°C Overload Protection 1.4 A (with short-circuit protection) Storage Temperature -40 to +85°C Power-on Value Yes Humidity 10 to 95% RH, Non-condensing Safe Value Yes ICP DAS CO., LTD Professional Provider of High Quality Industrial Computer Products and Data Acquisition Systems Remote I/O Modules  Internal I/O Structure  Wire Connections I-7055(D)/M-7055(D) LED Module I-7055(D)/I-7055(D)-NPN/M-7055(D)/M-7055(D)-NPN +5 V DI.COM +S5 V Embedded Controller DATA+Vs GND1 DC/DC Wet Contact (Sink) GND2 DO7 GND1 I-7055(D)-NPN/M-7055(D)-NPN LED Module +- DIx DI0 DATA+Vs GND +5 V DC/DC DI7 DI.GND Ext.PWR +5 V DO0 +S5 V DO7 Power Regulator +5 V GND1 GND1 DO.GND 10K - + To other channels DI.COM ON State Readback as 1 Output Type RS-485 Interface +4 VDC Max. To other channels I-7055(D)/M-7055(D) +S5 V DATA+ To other channels DI.COM DIx Digital Output (Resistance Load) Digital Output (Inductive Load)  Pin Assignments OFF State Readback as 0 DOx Load + - Load + - Ext.PWR DO.GND DOx DOx Ext.PWR DO.GND + - DO.GND Ext.PWR DO.GND I-7055(D)-NPN/M-7055(D)-NPN Output Type ON State Readback as 1 Digital Output + (Resistance Load) + - Digital Output (Inductive Load) + - Ext.PWR DOx OFF State Readback as 0 + - + - DO.GND Ext.PWR DOx Ext.PWR DOx DO.GND + - DO.GND Ext.PWR DOx DO.GND I-7055-G CR 8-channel Isolated Digital Input and 8-channel Isolated Digital Output Module using the DCON Protocol (Blue Cover) (RoHS) 8-channel Isolated Digital Input and 8-channel Isolated Digital Output Module using the DCON Protocol (Gray Cover) (RoHS) I-7055D CR I-7055 with LED Display (Blue Cover) (RoHS) I-7055D-G CR I-7055 with LED Display (Gray Cover) (RoHS) M-7055-G CR 8-channel Isolated Digital Input and 8-channel Isolated Digital Output Module using the DCON and Modbus Protocols (Gray Cover) (RoHS) M-7055D-G CR M-7055 with LED Display (Gray Cover) (RoHS) I-7055-NPN-G CR 8-channel Isolated Digital Input and 8-channel Isolated Digital Output Module (Gray Cover) (RoHS) I-7055D-NPN-G CR I-7055-NPN with LED Display (Gray Cover) (RoHS) M-7055-NPN-G CR 8-channel Isolated Digital Input and 8-channel Isolated Digital Output Module using the DCON and Modbus Protocols (Gray Cover) (RoHS) M-7055D-NPN-G CR M-7055-NPN with LED Display (Gray Cover) (RoHS) Website: http://www.icpdas.com  Accessories tM-7520U CR RS-232 to RS-485 Converter (RoHS) tM-7561 CR USB to RS-485 Converter (RoHS) tM-SG4 CR RS-485 Bias and Termination Resistor Module (RoHS) I-7514U CR 4-channel RS-485 Hub (RoHS) SG-770 CR 7-channel Differential or 14-channel Single-ended Surge Protector (RoHS) Signal Conditioning Modules for Thermocouple, SG-3000 Series RTD, DC Voltage, DC Current and Power Input Transformers E-mail: [email protected] I-7055(D)/I-7055(D)-NPN/M-7055(D)/M-7055(D)-NPN  Ordering Information I-7055 CR 3 DOx Ext.PWR + - 2 10K +- 10K DI.COM DI.COM Embedded Controller DIx To other channels - + To other channels +4 VDC Max. +10 ~ +50 VDC +S5 V EEPROM +S5 V DIx 10K DI.COM Wet Contact (Source) +5 V DIx DO.GND GND2 To other channels +10 ~ +50 VDC DO0 +5 V +S5 V +5 V +S5 V DIx Ext.PWR +5 V Open DI.GND Dry Contact DI7 DI.GND +5 V Power Regulator DI.GND RS-485 Remote I/O Modules GND RS-485 Interface OFF State Readback as 0 Close to GND DI0 EEPROM DATA+ ON State Readback as 1 Input Type +S5 V 2