Nsb12-425 Ups Battery

   EMBED


Share

Transcript

NSB12-425 UPS Battery Designed for mission critical applications NorthStar’s Pure Lead UPS batteries, ideal for use with datacenters and applications where downtime is not an option. Performance excels at high rates of discharge and recharge  15 year float life at 20°C (68°F) EUROBAT design life definition: Long Life (12+ years)  High energy density  Operating temperature range: -40°C to +65°C (-40°F to 149°F)  State-of-the-art automated manufacturing ensures consistency and reliability Advanced 3 stage terminal design to ensure leak-free operation - female M6 brass terminals provide maximum performance  2 year shelf life at 25°C (77°F) High modulus Polyphenylene Oxide (PPO) plastic materials designed to withstand extended elevated operating temperatures and maintain high battery compression essential for reliable operation - Non-halogenated, thermally sealed plastic casing - Flame retardant (UL 94 VO) and LOI of at least 28%  Pure lead, advanced valve regualted AGM batteries ensure power when it is needed most. Approved as non-hazardous cargo for ground, sea, and air transport - DOT 49CFR173.159(d), (i) and (ii) Visit our website to find out more www.northstarbattery.com Form: SES-543-00269-01 Issued: 05-14-15 ECO-100538 NSB12-425 UPS Battery Nominal Technical Specifications Electrical 4C (15 min.) Power to 1.67 VPC Float Voltage Nominal Voltage Impedance (1kHz) Conductance Short Circuit Current Shelf Life International Standard 20°C (68°F) 399 Watts/cell 2.29 +/- 0.02 VPC 12 V 2.7 mΩ @ 25°C (77°F) 1,763 S 3,600 A 2 Years North American Standard 25°C (77°F) 425 Watts/cell 2.27 +/- 0.02 VPC Dimensions Height Width Depth 213 mm (8.4 in) 173 mm (6.8 in) 341 mm (13.4 in) Weight Terminal Terminal Torque Constant Power Discharge Ratings End of Discharge (Volts) 1.75 1.70 1.67 1.65 1.60 2 807 873 911 934 986 34 kg (76 lbs) Female M6 x 1.0 Leak Proof 8.0 Nm (71 in-lbs) Duration (minutes) (watts/cell @ 25°C/77°F) 5 667 709 732 745 774 10 499 523 536 543 558 15 401 417 425 430 439 20 337 348 354 357 363 30 256 263 266 268 272 45 190 194 196 197 199 60 152 154 155 156 157 120 85 86 86 86 87 Discharge Curve to 1.67 VPC Drawings 900 Power (Watts/cell) 800 700 600 500 400 300 200 100 0 0 10 20 30 Time (minutes) 40 50 NorthStar Americas NorthStar Europe NorthStar Middle East, Africa NorthStar Asia-Pacific NorthStar Battery Company LLC 4000 Continental Way Springfield, MO, 65803, United States of America [email protected] Tel: +1 417 575 8200 Fax: +1 417 575 8250 SiteTel Sweden AB Staffans Väg 8 SE-192 07 Sollentuna, Stockholm, Sweden [email protected] Tel: +46 8 410 102 00 Fax: +46 8 638 06 00 SiteTel Sweden AB JTL Branch Office 702, Saba 1 Tower Jumeirah Lake Towers, Dubai United Arab Emirates [email protected] Tel: +971 4 423 8060 Fax: +971 4 423 8061 NS Asia Pacific Sdn. Bhd. B2-3A-13A, Solaris Dutamas No. 1, Jalan Dutamas 1, 50480 Kuala Lumpur, Malaysia [email protected] Tel: +60 3 6419 0711 www.northstarbattery.com Form: SES-543-00269-01 Issued: 05-14-15 ECO-100538