Preview only show first 10 pages with watermark. For full document please download

Ntp Time Distribution

   EMBED


Share

Transcript

SIGMA O O Option Module Cards Additional performance features are available with optional card. Add only the features you need by selecting option cards. Up to 6 cards can be accommodated per unit. In a few cases, the number of cards of any one type may be restricted. See maximum number of cards for each type. 1PPS 1PPS Input Alarm Contact Outputs 1PPS Output 1 PPS input 1 PPS output 1 Frequency input TTL or 10v (BNC), or Signal Type and TTL (BNC) RS-485 (terminal block) Connector 50 ohms Quantity Alarms Quantity Signal Type and Connector Maximum Number of Cards: 1 3 contacts NO/NC Relays (terminal block) Maximum Number of Cards: 6 IRIG Input / Output 1 input Quantity 2 outputs Signal Type and Amplitude modulated (0 to 5 v peak-to-peak into 50 ohms) or DC level shift (unmodulated), user-selectable, on BNC Connector IRIG A, B, E, G, NASA 36, Formats1 IEEE 1344/C37.118 ±20-200 microsec Accuracy (format dependent) Maximum Number of Cards: 6 Signal Type and Connector Formats1 Accuracy 3 ports NTP Management Enabled or disabled (NTP server only) Signal Type and Connector Maximum Number of Cards: 1 RJ45 Input / Output 1 input / 1 output RS-232 on DB-9 or RS-485 on terminal block ICD-GPS-153C: 253, 5040, 5101 (SINCGARS); NMEA: GGA, RMC, ZDA; Broadcast formats ±100-1000 microsec (format dependent) Time Resolution Ordinary clock, automatic slave or master selection, 1step or 2step operation +/- 4ns packet time-stamping Master Capacity Sync rate above 512 syncs/sec Mode Accuracy Network Delay Mechanism Connector 30ns (3s) master to slave via crossover cable IPv4, multicast End to end 10/100 Mb Ethernet, RJ45 (1 port per card) Maximum Number of Cards: 6, allowing a boundary clock type configuration Maximum Number of Cards: 6 1 Contact factory for details. PO BOX 1 49340 Trémentines FRANCE Tel. (33) 2 41 71 72 00 Fax (33) 2 41 71 72 02 [email protected] www.bodet.com Technical features and aesthetical aspects are subject to change without notice Made in France SPINNAKER : 02 41 55 06 35 - Réf. 653A71A/1012 Quantity Quantity Precision Time Protocol (PTP) Compliant with IEEE 1588v2-2008, 1 output 1 Contact factory for details. ASCII Time Code Gigabit Ethernet NTP GPS Time Synchronisation system NTP High precision Time server Bodet proposes a new synchronisation time center unit offering very high accuracy and high precision time quartz. SIGMA O O Main specifications : Network Management System Performance Network Protocols: Quartz model Sigma Oxo combines precision master clock technology and secure network approach with a compact modular hardware design to bring you a powerful time & frequency reference system. Applications will benefit from its extreme reliability, security, and flexibility for synchronizing critical operations. • Internal high precision time-keeping via TCXO, OCXO or rubidium oscillator. • Multiple, prioritized input time references. • Modular design with a wide variety of input/output signals supported. • High bandwidth NTP performance : Ethernet 10/100 Base-T. • Secure network management: enable or disable protocols for encryption, authentication, authorization and accounting. • Alarms notifications via SNMP, Traps and e-mail. • Stratum 1 master clock unit as for primary reference clock (PRC). Built in time and frequency functions are extended with up to 6 input/output modules. Included with the base unit is an extremely accurate 1PPS timing signal aligned to a 10 MHz frequency signal. Variety of option cards to add to your confi guration of timing signals, including additional PPS, 10MHz, time code (IRIG, ASCII), multinetwork NTP, and PTP outputs. An optional multi-port NTP configuration allows for operation across 4 isolated LAN segments. For security, system management can be restricted to a dedicated management LAN. Security-hardened network appliance designed to meet rigorous network security standards and best practices. Ensures accurate timing through multiple references, tamper-proof management. Installation is aided by DHCP (IPv4), AUTOCONF (IPv6), and a front-panel keypad and display. TCXO Accuracy (average over 24 hours 1x10-11 when GPS locked) Medium Term Stability (without GPS after 2 weeks of GPS lock) 1x10-8 /day OCXO Rubidium (Rb) 1x10-12 1x10-12 2x10-10 /day 5x10-11 /month (3x10-11/ month typical) 1 PPS Output 10 Mhz frequency signal : Accuracy to UTC (sigma locked to GPS) 50 ns ±25 ns ±25 ns Holdover (constant temp after 2 weeks of GPS lock) After 4 hours After 24 hours 12 µs 450 µs 0.5 µs 10 µs 0.2 µs 2 µs Signal Waveforms and Levels: TTL (5v p-p), into 50 ohm, BNC G 811 compliant with Rubidium version. Communications • RJ-45, network 10/100-baseT. • Input GPS antenna. • Outputs 1PPS, 10 MHz. Serial Set-up Interface (front panel) • RS-232 communications on DB-9 connector. Front Panel • LED display for time. • Lockable keypad and configurable LCD display for network set-up. • Power/Status LED. Power supply • 100-240 VAC, 50/60 Hz, ±10% with ventilation. Environment: • Operating temperature range: -20° to +65°C (+55°C for Rb). storage temperature : -40° to +85°C. environmental test according to MIL-STD- 810F. • NTP v2, v3, v4: Conforms with or exceeds RFC 1305 and 5905. Supports Unicast, Broadcast, Multicast, MD5 encryption, Peering, Stratum 2, Autokey. • SNTP v3, v4: Conforms with or exceeds RFC 1769, 2030, 4330, and 5905. • IPSec: IPv4/IPv6 Transport Mode. • IPv4/IPv6: Dual stack. • DHCP/DHCP6 (AUTOCONF): Automatic IP address assignment. • HTTP: Browser-based configuration and monitoring. • LDAP: Authentication. • RADIUS: Authentication. • Telnet: Remote configuration. • FTP Server: Access to logs. • Syslog: Logging. • Time (RFC868). • IEEE-1588v2 (PTP) via option card(s). Features: • • • • Enable/Block Protocols. Set SNMP Community Names and Network Access. Password Protected. SSL Web-based Interface: SSL is used to secure HTTPS protocol to access configuration and status web pages. • SNMP v3: v1,v2, v3. Remotely configure and manage over an encrypted connection. • Alarm notifications via SNMP traps, emails or contact relay. GPS Receiver • Outdoor GPS antenna supplied with SIGMA OXO. • Frequency: L1 (1575.42 MHz). Gain 35db. • Satellite tracking: 1 to 12, GPS T-RAIM satellite error management. • Synchronization time: cold start < 15 minutes (includes almanac download), warm start < 5 minutes (assumes almanac downloaded). Size/Weight: • Designed for EIA 19” 1u, rack. (425 mm W x 44 mm H x 356 mm D). • Weight: 2.72 kg. • Rack mount hardware included (assembly required). • Metal casing. • Rugged 19’’ chassis.