Transcript
DIGITAL CONTROLLERS
1 DIGITAL CONTROLLERS
2
Digital Indicating Controller with Multi-Input Computation Function SDC40B The SDC40B Digital Indicating Controller is a single loop digital indicating controller for controlling temperature, pressure, flow rates, levels, PH variables, etc. A compact instrument with PID control and various auxiliary functions, it offers instrumentation with a high level of cost performance. The Smart Loader Package allows the user to design any combination of functions.
RECORDERS, INDICATORES
3 CONVERTERS
4 FLAME SAFEGUARD SYSTEM
5
Input list
Specifications Analog input 1
Analog input 2
Analog input 3
Digital input
Computation processing block
Output processor
ACTUATORS
Mode Communication specifications General specifications
Input type
Multi-range of inputs—thermocouple, resistance thermometer detector, DC voltage, and DC current, etc. Input indication accuracy ±0.1% FS±1U (under standard conditions; this may be affected by indication value conversion and range.) Sampling cycle 0.1 to 0.5 sec. (depends on computation cycle) Input type 4 to 20 mA DC, 1 to 5 Vdc Input indication accuracy ±0.1% FS±1U (display value conversion under standard conditions) Sampling cycle 0.1 to 0.5 sec. (depends on computation cycle) Input type 1 to 5 Vdc Input indication accuracy ±0.1% FS±1U (display value conversion under standard conditions) Sampling cycle 0.1 to 0.5 sec. (depends on computation cycle) Number of inputs 12 Connectable output types Non-voltage contacts (relay contacts) and open collector (current sink to ground) PID control and Code 2G 5G output unit M/M driving relay Current output AO1 contact output (4 to 20 mA DC) Current output AO2 None (4 to 20 mA DC) Current output Current output AO3 (4 to 20 mA DC) (4 to 20 mA DC) Position proportional PID Current Control action and current proportional PID proportional PID 8 groups (shared by PID computation units 1 and 2) Number of PID groups Neuro & fuzzy (with two degree of freedom) and smart methods PID auto-tuning are used in addition to the limit cycle method to set PID auto-tuning. 2G A01: M/M driving relay contact output Analog output 2G A03, 5G A01, A02, A03: current output (4 to 20 mA) (A01 to A03) D01, D02: SPST relay contact Digital output D03: SPDT relay contact (D01 to 08) D04 to D08: open collector Normal operating mode, emergency operating mode RS-485, RS-232C
Input type Thermocouple
Symbol K, E, J, T, B, R, S, W (WRe5-26), PR40-20, Ni·Mo-Ni, N, PL II, DIN U, DIN L
Resistance thermometer detector DC current/ voltage
JIS'89 Pt100 JIS'89 JPt100 4 to 20 mA, 0 to 20 mA, 0 to 10 mV -10 to +10 mV, 0 to 100 mV 0 to 1 V, -1 to +1 V, 1 to 5 V, 0 to 5 V 0 to 10 V
Standards for input sensor Thermocouple
Resistance thermometer detector
K, E, J, T, B, R, S: JIS C 1602-1981 WRe5-26: material from Hoskins PR40-20: material from Johnson Matthey Ni·Mo-Ni: material from General Electric N: N.B.S. Monograph 161 PL II: material from Engelhard Industries (IPTS68) DIN U, DIN L: DIN 43710-1985 Chromel/Gold-iron: material from Hayashi Denko Pt100, JPt100: JIS C 1604-1989
AC power supply model: 100 to 240 Vac 50/60 Hz, DC power supply model: 24 Vdc Max. 30 VA Approx. 900 g
Rated power supply voltage Power consumption Weight
External dimensions (Unit: mm)
(18)
SENSORS
Hard dust-proof cover set (separately ordered) 81446083-001
15
Terminal cover set (separately ordered) 81446084-001 159.5 137 Mounting bracket 81405411-001
96
49
57
50
58
4
43
51
59
29
5
44
52
60
30
6
45
53
61
31
7
46
54
62
32
47
55
63
48
56
64
EV3
A/M
OT1 UF1
R/L
OT2 UF2
PARA
AT
UF DISP
96
EV1 EV2
(106×104)
3
OUT
7
41 42
2
SP DEV OUT
SP/EV
26
1
RDY REM CH1 MAN CH2 COM CH3
8
LOADER AT
ENT
9 10
GAS FLOW MEASUREMENT AND CONTROL PRODUCTS
1-22
Soft dust-proof cover set (separately ordered) 81446087-001
Standard terminal base
Extension terminal base
37
27 28
33 34
110.5
6
DIGITAL CONTROLLERS
Digital Indicating Controller with Multi-Input Computation Function SDC40B Function
Power supply
Option 1
Option 2
Addition
Ex.: C40B5G4AS09100 Description
Digital Indicating Controller
C40B 2G
Position proportional output
5G
Current output (4 to 20 mA/0 to 20 mA)
DIGITAL CONTROLLERS
Model No. configuration Basic model No. Control output
1
Input 1: thermocouple, resistance thermometer detector, DC current and DC voltage multi-range inputs
4
2: 4 to 20 mAdc or 1 to 5 Vdc 3: 1 to 5 Vdc 06*
1 auxiliary output, 12 digital inputs, 8 digital outputs (3 relays and 5 open collectors)
09*
2 auxiliary outputs, 12 digital inputs, 8 digital outputs (3 relays and 5 open collectors) 1
No communication interface
2
RS-485 communication RS-232C communication
3
Order this product by specifying a model No. beginning with C40**. *. Option 06 can be specified only when control output is 2G. Option 09 can be specified only when control output is 5G.
Optional parts (sold separately) Smart Loader Package Smart Loader Package User’s manual, without loader cable Hard dust-proof cover set Soft dust-proof cover set Terminal cover set
Model No. SLP-C4BJ70 SLP-C4BJ71 81446083-001 81446087-001 81446084-001
None
D0
Inspection certificate
Y0
Supports traceability certification
3 CONVERTERS
Name
00
2 RECORDERS, INDICATORES
100 to 240 Vac 50/60 Hz
AS
The indications on SLP-C4B are basically all in Japanese, but some of the error messages and indications in the design sheet and data trend functions are in English.
4 FLAME SAFEGUARD SYSTEM
5 ACTUATORS
6 SENSORS
7 GAS FLOW MEASUREMENT AND CONTROL PRODUCTS
1-23