Preview only show first 10 pages with watermark. For full document please download

Null 10960624

   EMBED


Share

Transcript

DIGITAL CONTROLLERS 1 DIGITAL CONTROLLERS 2 Digital Indicating Controller with Multi-Input Computation Function SDC40B The SDC40B Digital Indicating Controller is a single loop digital indicating controller for controlling temperature, pressure, flow rates, levels, PH variables, etc. A compact instrument with PID control and various auxiliary functions, it offers instrumentation with a high level of cost performance. The Smart Loader Package allows the user to design any combination of functions. RECORDERS, INDICATORES 3 CONVERTERS 4 FLAME SAFEGUARD SYSTEM 5 Input list Specifications Analog input 1 Analog input 2 Analog input 3 Digital input Computation processing block Output processor ACTUATORS Mode Communication specifications General specifications Input type Multi-range of inputs—thermocouple, resistance thermometer detector, DC voltage, and DC current, etc. Input indication accuracy ±0.1% FS±1U (under standard conditions; this may be affected by indication value conversion and range.) Sampling cycle 0.1 to 0.5 sec. (depends on computation cycle) Input type 4 to 20 mA DC, 1 to 5 Vdc Input indication accuracy ±0.1% FS±1U (display value conversion under standard conditions) Sampling cycle 0.1 to 0.5 sec. (depends on computation cycle) Input type 1 to 5 Vdc Input indication accuracy ±0.1% FS±1U (display value conversion under standard conditions) Sampling cycle 0.1 to 0.5 sec. (depends on computation cycle) Number of inputs 12 Connectable output types Non-voltage contacts (relay contacts) and open collector (current sink to ground) PID control and Code 2G 5G output unit M/M driving relay Current output AO1 contact output (4 to 20 mA DC) Current output AO2 None (4 to 20 mA DC) Current output Current output AO3 (4 to 20 mA DC) (4 to 20 mA DC) Position proportional PID Current Control action and current proportional PID proportional PID 8 groups (shared by PID computation units 1 and 2) Number of PID groups Neuro & fuzzy (with two degree of freedom) and smart methods PID auto-tuning are used in addition to the limit cycle method to set PID auto-tuning. 2G A01: M/M driving relay contact output Analog output 2G A03, 5G A01, A02, A03: current output (4 to 20 mA) (A01 to A03) D01, D02: SPST relay contact Digital output D03: SPDT relay contact (D01 to 08) D04 to D08: open collector Normal operating mode, emergency operating mode RS-485, RS-232C Input type Thermocouple Symbol K, E, J, T, B, R, S, W (WRe5-26), PR40-20, Ni·Mo-Ni, N, PL II, DIN U, DIN L Resistance thermometer detector DC current/ voltage JIS'89 Pt100 JIS'89 JPt100 4 to 20 mA, 0 to 20 mA, 0 to 10 mV -10 to +10 mV, 0 to 100 mV 0 to 1 V, -1 to +1 V, 1 to 5 V, 0 to 5 V 0 to 10 V Standards for input sensor Thermocouple Resistance thermometer detector K, E, J, T, B, R, S: JIS C 1602-1981 WRe5-26: material from Hoskins PR40-20: material from Johnson Matthey Ni·Mo-Ni: material from General Electric N: N.B.S. Monograph 161 PL II: material from Engelhard Industries (IPTS68) DIN U, DIN L: DIN 43710-1985 Chromel/Gold-iron: material from Hayashi Denko Pt100, JPt100: JIS C 1604-1989 AC power supply model: 100 to 240 Vac 50/60 Hz, DC power supply model: 24 Vdc Max. 30 VA Approx. 900 g Rated power supply voltage Power consumption Weight External dimensions (Unit: mm) (18) SENSORS Hard dust-proof cover set (separately ordered) 81446083-001 15 Terminal cover set (separately ordered) 81446084-001 159.5 137 Mounting bracket 81405411-001 96 49 57 50 58 4 43 51 59 29 5 44 52 60 30 6 45 53 61 31 7 46 54 62 32 47 55 63 48 56 64 EV3 A/M OT1 UF1 R/L OT2 UF2 PARA AT UF DISP 96 EV1 EV2 (106×104) 3 OUT 7 41 42 2 SP DEV OUT SP/EV 26 1 RDY REM CH1 MAN CH2 COM CH3 8 LOADER AT ENT 9 10 GAS FLOW MEASUREMENT AND CONTROL PRODUCTS 1-22 Soft dust-proof cover set (separately ordered) 81446087-001 Standard terminal base Extension terminal base 37 27 28 33 34 110.5 6 DIGITAL CONTROLLERS Digital Indicating Controller with Multi-Input Computation Function SDC40B Function Power supply Option 1 Option 2 Addition Ex.: C40B5G4AS09100 Description Digital Indicating Controller C40B 2G Position proportional output 5G Current output (4 to 20 mA/0 to 20 mA) DIGITAL CONTROLLERS Model No. configuration Basic model No. Control output 1 Input 1: thermocouple, resistance thermometer detector, DC current and DC voltage multi-range inputs 4 2: 4 to 20 mAdc or 1 to 5 Vdc 3: 1 to 5 Vdc 06* 1 auxiliary output, 12 digital inputs, 8 digital outputs (3 relays and 5 open collectors) 09* 2 auxiliary outputs, 12 digital inputs, 8 digital outputs (3 relays and 5 open collectors) 1 No communication interface 2 RS-485 communication RS-232C communication 3 Order this product by specifying a model No. beginning with C40**. *. Option 06 can be specified only when control output is 2G. Option 09 can be specified only when control output is 5G. Optional parts (sold separately) Smart Loader Package Smart Loader Package User’s manual, without loader cable Hard dust-proof cover set Soft dust-proof cover set Terminal cover set Model No. SLP-C4BJ70 SLP-C4BJ71 81446083-001 81446087-001 81446084-001 None D0 Inspection certificate Y0 Supports traceability certification 3 CONVERTERS Name 00 2 RECORDERS, INDICATORES 100 to 240 Vac 50/60 Hz AS The indications on SLP-C4B are basically all in Japanese, but some of the error messages and indications in the design sheet and data trend functions are in English. 4 FLAME SAFEGUARD SYSTEM 5 ACTUATORS 6 SENSORS 7 GAS FLOW MEASUREMENT AND CONTROL PRODUCTS 1-23