Transcript
Tech News Letter : CCC/March/Tech/129
Author :Schneider Technical Support Team
Rev : 00
Last Modified On- 15 Mar 2014
th
PRODUCT LAUNCH SUBJECT
Release of Quantum Ethernet NRP Fiber Optic Converter Modules 140NRP31200(C) & 140NRP31201(C)
TARGTED AUDIENCE
System Integrator, End User, OEM, Tech Support
CONTENTS
FAMILY : Controller Platform RANGE: Modicon Quantum
PICTURE
NEW EVOLUTION
Introducing the new Quantum Ethernet NRP Fiber Optic Converter Modules 140NRP31200(C) & 140NRP31201(C), In rack Ethernet Fiber Optic converter with Quantum module form factor on Quantum Platform. Key benefits of this release include:
CUSTOMER VALUE
In rack Ethernet Fiber Optic converter with Quantum module form factor on Quantum Platform Extend the Ethernet transmission distance up to 15 km with 140NRP31201(C) and 2 km with 140NRP31200(C) Better resistance against the electronic noise Provide a fully integrated fiber optic Quantum + X80 Ethernet RIO architecture Easy implementation without programming Easy maintenance Provide a smooth migration path for Quantum S908 user
The 140NRP31200 and 140NRP31201 modules are available in Unity Pro XL starting from version 8.0. Please click here to download the datasheet.
1 Schneider Electric –TSC India ,
[email protected]
SOFTWARE UPDATE SUBJECT
Release of BMXNOE0110 Exec v5.7 for M340 Ethernet Module
TARGTED AUDIENCE
System Integrator, End User, OEM, Tech Support
CONTENTS
FAMILY: Controller Plateform RANGE: Modicon M340
PICTURE
NEW EVOLUTION
This Firmware has been introduced with Fixes/Enhancement in BMXNOE0110.
This Firmware Fixes the following issues:
CUSTOMER VALUE
• Unity allows the user to select the checkbox for 'Automatically adjust clock for daylight savings change.'however, when you open the NTP webpage after transferring the application to the PLC, it will show the DST Status as 'OFF'. When the time for daylight savings change occurs, the clock does not get adjusted. • 'Null Reference Exception' error is returned when changing to certain web pages
Please click here to download the Firmware BMXNOE0110 V5.7.
2 Schneider Electric –TSC India ,
[email protected]
SUBJECT
RECENT FAQs
TARGTED AUDIENCE
System Integrator, End User, OEM, Tech Support.
CONTENTS
FAMILY : Controller Platform RANGE: Modicon Quantum Question: Which Fiber Optic cables can be used in 140NRP31200(C) and 140NRP31201(C) fiber optic converter modules. Answer:
FAQ1
The fiber optic cables recommended are the ones with the following characteristics: ·For multi-mode: 50/125 µm fiber cable with optical power -23.5 … -14 dBm, 62.5/125 µm fiber cable with optic power -20 … -15 dBm. Wavelength 1310nm Connector type: LC ·For single-mode: 9/125 µm fiber cable with optical power -15…-8 dBm Wavelength 1310nm Connector type: LC Schneider Electric is selling fiber optic cables under the Actassi range: click here for more details. Example: The cable VDIC42302T and VDIB504201H can be used for multi-mode fiber connection with 140NRP31200(C).
CONTENTS
FAMILY: Operation & Optimization RANGE: Vijeo Historian
Question: How to resolve the error come up saying, "The search failed with the following error: A request to the Historian Web Service has failed." When attempting to search for trends or alarms in the Add New Pen(s) screen in Process Analyst.
FAQ2 Answer: One of the reasons why you see this error is because one of the folders within published information has the word "Historian" or "SCADA" as part of the name. As they are internally reserved names, having them as part of the folder name will cause Process Analyst to fail. The fix for this will only be included in future versions so work-around will have to be used for current version for now by renaming the folders to exclude "Historian" and "SCADA" from folder names.
Find the answers you need with our new FAQ Technical Knowledge base. Over 2000 regularly updated FAQs available. http://www.schneider-electric.co.in/sites/india/en/support/faq/faq_main.page
3 Schneider Electric –TSC India ,
[email protected]
SUBJECT
TECHNOTES
TARGTED AUDIENCE
System Integrator, End User, OEM, Tech Support.
CONTENTS
Technote on “How can I Integrate HART Instrumentation into PlantStruxure Architecture”
TECHNICAL NOTE
This TVDA guide presents design and implementation options for the Modicon STB HART multiplexer within PlantStruxure architectures, as well evaluation of the effect of several factors that can influence performance. This guide outlines the benefits and limitations of using HART technology. Click here to download this technote.
CUSTOMER VALUE
Various system designs Usage of multiplexer and instrument DTMs Factors that affect HART data update time Integration of Krohne HART instruments Implementation of the Krohne HART library within Unity Pro and Vijeo Citect
NEWS FLASH: “A song for Schneider Foundation...by Anwesha, A Green Ambassador from Bangalore!!” For More details please click here
4 Schneider Electric –TSC India ,