Preview only show first 10 pages with watermark. For full document please download

Null 13093546

   EMBED


Share

Transcript

DATA SHEET LS Programmable Logic Controller RTD Input Module  Safety Precautions ► Safety Precautions is for using the product safely and correctly in order to prevent the accidents and danger, so please go by them. ► The precautions explained here only apply to this module. For safety precautions on the PLC system, refer to User‟s manual. ► The precautions are divided into 2 sections, „Warning‟ and „Caution‟. Each of the meanings is represented as follows. If you violate instructions, it can cause death, fatal injury or a XGB Warning considerable loss of property XBF-RD04A Caution If you violate instructions, it can cause a slight injury or a slight loss of products ► The symbols which are indicated in the PLC and User‟s Manual mean as follows. This symbol means paying attention because of danger of injury, fire, or malfunction ► This symbol means paying attention because of danger of electric shock. Store this datasheet in a safe place so that you can take it out and read it whenever necessary. Always forward it to the end user  Handling Precautions ► Don‟t drop or make impact. ► Don‟t detach PCB from case. It may cause problem. ► When wiring, let no foreign material go into the module. If it goes into the module, remove it. ► Don‟t detach the module from slot while power is on Related Manual Read this data sheet carefully prior to any operation, mounting, installation or start-up of the product. Name Code XGB analog 10310000862 XGK XGB Instruction & Programming 10310000509 XGI XGR XEC Instruction & Programming 10310000739 XGB Hardware 10310000893 XGB Hardware (IEC) 10310000981 XG5000 10310000511 Revision History Date 2007. 6 2009. 5 2009. 8 Warning 2011. 5 V3.0 2011.12 V3.1 No ► Do not contact the terminals while the power is applied. Risk of electric shock and malfunction. 3 ► Protect the product from being gone into by foreign metallic matter. Risk of fire, electric shock and malfunction. 4 Item  LSIS Tokyo Office _ Tokyo, Japan Tel: 81-3-3582-9128 Fax: 81-3-3582-2667 . e-mail: [email protected] ► Use the PLC in an environment that meets the general specifications contained in this datasheet. Risk of electrical shock, fire, erroneous operation and deterioration of the PLC.  LSIS Shanghai Office _ Shanghai, China Tel: 86-21-5237-9977(609) Fax: 89-21-5237-7189  LSIS Beijing Office _ Beijing, China Tel: 86-10-5825-6027(666) Fax: 86-10-5825-6028 e-mail: [email protected]  LSIS Guangzhou Office _ Guangzhou, China Tel: 86-20-8328-6754 Fax: 86-20-8326-6287 e-mail: [email protected]  LSIS Chengdu Office _ Chengdu, China Tel: 86-20-8328-6754 Fax: 86-20-8326-6287 ► Be sure that external load does not exceed the rating of output module. Risk of fire and erroneous operation. e-mail: [email protected] ► Do not use the PLC in the environment of direct vibration Risk of electrical shock, fire and erroneous operation. - 5 ~ 95%RH, non-condensing - 5 ~ 95%RH, non-condensing - 80 ~ 1,000 MHz, 10 V/m Power supply module Segment Fast transient /burst noise Voltage Ambient conditions Operating height Pollution degree Cooling type 8 10 11 ► When disposing of PLC and battery, treat it as industrial waste. Risk of poisonous pollution or explosion. - -25 ~ 70℃ Radiated electromagnetic field noise Noise resistance 7 9 ► Do not disassemble, repair or modify the PLC. Risk of electrical shock, fire and erroneous operation Standard 0 ~ 55℃ For discontinuous vibration Acceleration Amplitude Frequency times 10≤f∠57 Hz 0.075 mm 10 times in Vibration 57 ≤f≤150 Hz 9.8㎨ (1G) each resistance For continuous vibration direction Acceleration Amplitude Frequency for 10≤f∠57 Hz 0.035 mm X, Y, Z 57≤f≤150 Hz 4.9㎨(0.5G)  Max. impact acceleration : 147 ㎨ (15G) Shocks  Authorized time : 11㎳ resistance  Pulse wave : Sign half-wave pulse (Each 3 times in X,Y,Z directions) Square wave AC: ±1,500V impulse noise DC: ±900V Electrostatic Voltage: 4kV (Contact discharge) discharge 6 ► Tighten the screw of terminal block with the specified torque range. If the terminal screw is loose, it can cause fire and electric shock.  LSIS Europe B.V., Netherlands Tel: +31 (0)20 654 1420 Fax: +31(0)20 654 1429 e-mail: [email protected] PLC Others PLC 40ms / channel Non- insulation Photo-Coupler 15 points Fixed type :64 points,Changeable type:16 points 7 (XBM(XBC)-DxxxS “S” type) 10 (XBC(XEC)-DxxxH “H” type) 3-wire Digital filter (160 ~ 64000ms) Disconnection detection 100㎃ 100㎃ 630g 2 kV Digital/analog input/output communication interface 1 kV IEC61131-2 IEC61131-2 LSIS standard IEC61131-2 IEC61000-4-2 IEC61131-2 IEC61000-4-3 IEC61131-2 IEC61000-4-4 No corrosive gas or dust - 2000m or less - 2 or less - Natural air cooling - No. Name ① RUN LED ② ALM LED ③ Terminal block External power supply terminal Connector for extension  Precautions for use Others Within ±0.5% ⑤ ④ ► Do not Install other places except PLC controlled place. ► Make sure that the FG terminal is grounded with class 3 grounding which is dedicated to the PLC. Otherwise, it can cause disorder or malfunction of PLC PLC Within±0.3% - e-mail: [email protected]  LSIS Qingdao Office _ Qingdao, China Tel: 86-532-8501-6068 Fax: 86-532-8501-6057 e-mail: [email protected] Wiring method Filtering Alarm DC5V Current consumption DC24V Weight Specifications 4 channels JIS C1604-1997 JIS C1604-1981 , KS C1603-1991 -200 ~ 600℃ -200 ~ 600℃ -200.0 ~ 600.0℃ -200.0 ~ 600.0℃ 0 ~ 4000 3. Parts Names and Descriptions Operating humidity Storage humidity ► Be sure to check the rated voltage and terminal arrangement for the module before wiring work. Risk of electric shock, fire and malfunction. e-mail: [email protected] Max. equip-able number Specification Operating temperature Storage temperature 5  LSIS(ME) FZE _ Dubai, U.A.E. Tel: 971-4-886-5360 Fax: 971-4-886-5361 I/O points occupied 1. General Specifications 2 Caution Item No. of input channel PT100 Input sensor type JPT100 PT100 Temperature input range JPT100 PT100 Digital output JPT100 Scaling display Normal temp.(25℃) Accuracy Full temp.(0~55℃) Conversion speed Channel to Channel Insulation Terminal to PLC Power Terminal block Function ► Risk of fire, electric shock and malfunction. Risk of injury and fire by explosion and ignition.  HEAD OFFICE LS Tower, 127, LS-ro, Dongan-gu, Anyang-si,Gyeonggi-do, 431-848, Korea Tel: 82-2-2034-4870 Fax: (82-2)2034-4648 e-mail: [email protected] Updated Information First Edition Error in performance specifications is fixed Branch address changed KOREAN/ENGLISH data sheet integrated CI Changed Error in Parts Names and Descriptions is fixed Error in Extendable Smart I/O adapter is fixed Applicable version For system configuration, the following version is necessary. Item Applicable Version XG5000 V3.6 or above 1 - When using LSIS equipment, thoroughly read this datasheet and associated manuals introduced in this datasheet. Also pay careful attention to safety and handle the module properly. - Store this datasheet in a safe place so that you can take it out and read it whenever necessary. Version V1.0 V2.0 V2.2 2. Performance Specifications ⑤ Others Descriptions ▶ Displays the hardware operation status of XBF-RD04A On: Normal Flickering: Error (0.2s flickering) Off: power disconnected, hardware error ▶Displays the disconnection status of XBF-RD04A (Alarm indication LED) Flickering: Disconnection is detected (1sec flickering) Off: normal operation ▶Terminal block for connecting external RTD temperature sensor ▶Terminal for supplying external DC24V ▶Connection connector for connecting extension module  Homepage: http://eng.lsis.biz A) Best LS constantly endeavors to improve our products so that information in this datasheet is subject to change without notice. The date of issue: 2011.12 10310000745 Ver 3.1 ► ► ► ► ► C) Bad B) Good Connect expansion connector correctly when expansion module is needed. Do not detach PCB from the case of the module and do not modify the module. Turn off power when attaching or detaching module. Cellular phone or walkie-talkie should be farther than 30cm from the PLC. Input signal and communication line should be farther than 10cm from a hightension and a power line in order not to be affected by noise and magnetic field. 4. Wiring 5. Configuration of internal memory 6. Extendable Smart I/O adapter (1) Precautions for wiring (a) Don‟t let AC power line near to RTD module‟s external input signal line. With an enough distance kept away between, it will be free from surge or inductive noise. (b) Cable shall be selected in due consideration of ambient temperature and allowable current, whose size is not less than the max. cable standard of AWG22 (0.3㎟). (c) Don‟t let the cable too close to hot device and material or in direct contact with oil for long, which will cause damage or abnormal operation due to shortcircuit. (d) Check the wire when wiring the terminal. (e) Wiring with high-voltage line or power line may produce inductive hindrance causing abnormal operation or defect. 1) Input/Output area of conversion data. (U device) XBF-RD04A can be installed for Smart I/O(XPL-BSSA) by Max 4. (2) Wiring examples (a) 3 types of sensor connecting methods are available (2,3 and 4-wire) (b) Used an identical type of wire (thickness ,length ,etc) for each 3 wire when extended lead wire is used (c) The resistance of each conductor is to be less than 10Ω. (If lager than this, if will cause an error.) (d) Length of wire is to be as short as possible and it is recommended to connect the wire directly to the terminal block of XBF-RD04A without connection terminal unit. If a connection terminal is to be used, compensating wire shall be connected as shown below. Method Wiring examples Disconnection A B 2-wire 1* b F 2 G * A B 3-wire b 1* 2 * F G 1.When the channel is enabled -Disconnection detection enabled. Area (‘S’, ‘H’ type) U0x.00.0 U0x.00.F U0x.01.0 U0x.01.1 U0x.01.2 U0x.01.3 U0x.01.4 U0x.01.5 U0x.01.6 U0x.01.7 U0x.04 U0x.05 U0x.06 U0x.07 U0x.08 U0x.09 U0x.10 U0x.11 Area (IEC type) %UX0.x.0 %UX0.x.15 %UX0.x.16 %UX0.x.17 %UX0.x.18 %UX0.x.19 %UX0.x.20 %UX0.x.21 %UX0.x.22 %UX0.x.23 %UW0.x.4 %UW0.x.5 %UW0.x.6 %UW0.x.7 %UW0.x.8 %UW0.x.9 %UW0.x.10 %UW0.x.11 Details Content R/W Module ERROR flag Module READY flag CH0 Run flag CH1 Run flag CH2 Run flag CH3 Run flag CH0 Disconnection flag CH1 Disconnection flag CH2 Disconnection flag CH3 Disconnection flag CH0 digital output value CH1 digital output value CH2 digital output value CH3 digital output value CH0 scaling value CH1 scaling value CH2 scaling value CH3 scaling value 0 Bit On(1): module error F(15) Bit On(1): module normal R Bit On(1): channel run Bit Off(0): channel stop R Bit On(1): Disconnection Bit Off(0): Normal R 7. Disconnection information Address (Dec) (1) XPL-BSSA (Pnet I/F adapter) parameter setting (a) Parameter setting window 68 ~ 71 Temperature value ×10 0 ~ 4000 2) Operation parameter setting area of the RTD module Memory address Details Hex. Dec. 0H 0 Channel enable/disable setting 1H 1 CH0 sensor type setting 2H 2 CH1 sensor type setting 3H 3 CH2 sensor type setting 4H 4 CH3 sensor type setting 5H 5 Temperature display unit setting 6H 6 CH0 filter constant setting 7H 7 CH1 filter constant setting 8H 8 CH2 filter constant setting 9H 9 CH3 filter constant setting AH – 11H 10~17 Not used 12H 18 Scaling setting 13H - 43H 19~67 Not used 44H 68 CH0 disconnection information (code) 45H 69 CH1 disconnection information (code) 46H 70 CH2 disconnection information (code) 47H 71 CH3 disconnection information (code) R R R R R R R R R/W Remark R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W PUT PUT PUT PUT PUT PUT PUT PUT PUT PUT PUT GET GET GET GET (2)Paremeter setting area Item Range 0 1 2 3 Byte 4 5 6 7 Value 0 Value 1 2 3 JPT100 Farennite 9. Warranty Remarks 1) If do not set parameter value, operates on initial value (PT100, Celsious). 2) Setting value inputs in XBF-RD04A Output respectively. 3) Parameter value is maintained in connecting communication. At disconnecting communication, parameter value is same as initial value when power is changed Off to On status. (2) XDL-BSSA (Dnet I/F adapter) parameter setting (a) Parameter setting window 2. When the channel is disabled -Disconnection detection disabled. b 2 * F G (b) Paremeter setting area address 7 6 5 4 3 0 - - - Temp. 0 Remarks *1 : Let the terminals B and b short on the terminal block of the module if 2-wired sensor is to be connected. *2 : If sensor and compensating wire are shielded, shield line can be connected to FG. Remark Descriptions Expansion module slot1 installed Expansion module slot2 installed Expansion module slot3 installed Expansion module slot4 installed Expansion module slot5 installed Expansion module slot6 installed Expansion module slot7 installed Expansion module slot8 installed Sensor Temperature Digital output PT100 Celsious JPT100 Celsious -2,000 ~ 6,000 PT100 Farennite B 1* Description Normal operation ALM LED Off A line disconnection B line disconnection ALM LED 1s flickering A line/B line disconnection 8. Dimension (㎜) A 4wire Error code 0 1 2 3 - 1 - - - - - 2 1 - - - - 의미 Bit On(1): channel run CH Bit Off(0): channel stop 0 Bit On(1): Farennite Bit Off(0): Celsious 0 < Sensor value setting > CH Bit On(1): JPT100 0 Bit Off(0): PT100 (1) Warranty period LSIS provides an 18-month-warranty from the date of the production. (2) Warranty conditions For troubles within the warranty period, LSIS will replace the entire PLC or repair the troubled parts free of charge except the following cases. (a) The troubles caused by improper condition, environment or treatment except the instructions of LSIS. (b) The troubles caused by external devices. (c) The troubles caused by remodeling or repairing based on the user‟s own discretion. (d) The troubles caused by improper usage of the product. (e) The troubles caused by the reason which exceeded the expectation from science and technology level when LSIS manufactured the product. (f) The troubles caused by natural disaster. (3) This warranty is limited to the PLC itself only. It is not valid for the whole system which the PLC is attached to.