Transcript
PUBLIC ADDRESS SYSTEM AUDIO
OPERATION MANUAL
T-6212 PAGING SELECTOR
T-6212 PAGING SELECTOR POWER
PAGING ZONES
MIC 1 4
ON OFF
5
MIC 2 4
6
3
7
1
9
2
1
2
3
4
5
6
7
8
9
10
0
10
5
6
3 8
7
2
8 1
9 0
10
CHIME
MIC 1
Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.
V1.0-2008-09-17
TABLE OF CONTENTS 1. SAFETY PRECAUTIONS .......................................................................................3 2. GENERAL DESCRIPTION ....................................................................................5 3. FEATURES ...............................................................................................................5 4. NOMENCLATURE AND FUNCTIONS 4.1 Front Panel .............................................................................................................6 4.2 Rear Panel............................................................................................................. 7
5. MACHINE OPERATION ....................................................................................... 8 6. APPLICATIONS ......................................................................................................9 7.SPECIFICATIONS ................................................................................................. 10 8.DIMENSIONAL DIAGRAM ....................................................................................11
T-6212
2
1. SAFETY PRECAUTIONS Be sure to read the instructions in this section carefully before use. Make sure to observe the instructions in this manual as the conventions of safety symbols and messages regarded as very important precautions are included. We also recommend you keep this instruction manual handy for future reference.
Safety Symbol and Message Conventions Safety symbols and messages described below are used in this manual to prevent bodily injury and property damage which could result from mishandling. Before operating your product, read this manual first and understand the safety symbols and messages so you are thoroughly aware of the potential safety
Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury. Indicates a potentially hazardous situation which, if mishandled, could result in moderate or minor personal injury, and/or property damage.
When Installing the Unit Do not expose the unit to rain or an environment where it may be splashed by water or other liquids, as doing so may result in fire or electric shock. Use the unit only with the voltage specified on the unit. Using a voltage higher than that which is specified may result in fire or electric shock. Do not cut, kink, otherwise damage nor modify the power supply cord. In addition, avoid using the power cord in close proximity to heaters, and never place heavy objects -- including the unit itself -- on the power cord, as doing so may result in fire or electric shock. Be sure to replace the unit's terminal cover after connection completion. Because high voltage is applied to the speaker terminals, never touch these terminals to avoid electric shock. Be sure to ground to the safety ground (earth) terminal to avoid electric shock. Never ground to a gas pipe as a catastrophic disaster may result. Avoid installing or mounting the unit in unstable locations, such as on a rickety table or a slanted surface. Doing so may result in the unit falling down, causing personal injury and/or property damage.
3
T-6212
When the Unit is in Use Should the following irregularity be found during use, immediately switch off the power, disconnect the power supply plug from the AC outlet and contact your nearest ITC dealer. Make no further attempt to operate the unit in this condition as this may cause fire or electric shock. If you detect smoke or a strange smell coming from the unit. If water or any metallic object gets into the unit If the unit falls, or the unit case breaks If the power supply cord is damaged (exposure of the core, disconnection, etc.) If it is malfunctioning (no tone sounds.) To prevent a fire or electric shock, never open nor remove the unit case as there are high voltage components inside the unit. Refer all servicing to your nearest ITC dealer. Do not place cups, bowls, or other containers of liquid or metallic objects on top of the unit. If they accidentally spill into the unit, this may cause a fire or electric shock. Do not insert nor drop metallic objects or flammable materials in the ventilation slots of the unit's cover, as this may result in fire or electric shock.
1. SAFETY PRECAUTIONS
When Installing the Unit Never plug in nor remove the power supply plug with wet hands, as doing so may cause electric shock. When unplugging the power supply cord, be sure to grasp the power supply plug; never pull on the cord itself. Operating the unit with a damaged power supply cord may cause a fire or electric shock. When moving the unit, be sure to remove its power supply cord from the wall outlet. Moving the unit with the power cord connected to the outlet may cause damage to the power cord, resulting in fire or electric shock. When removing the power cord, be sure to hold its plug to pull. Do not block the ventilation slots in the unit's cover. Doing so may cause heat to build up inside the unit and result in fire. Avoid installing the unit in humid or dusty locations, in locations exposed to the direct sunlight, near the heaters, or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric shock.
When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and/or property damage. In addition, the object itself may fall off and cause injury and/or damage. Make sure that the volume control is set to minimum position before power is switched on. Loud noise produced at high volume when power is switched on can impair hearing. Do not operate the unit for an extended period of time with the sound distorting. This is an indication of a malfunction, which in turn can cause heat to generate and result in a fire. Contact your ITC dealer as to the cleaning. If dust is allowed to accumulate in the unit over a long period of time, a fire or damage to the unit may result. If dust accumulates on the power supply plug or in the wall AC outlet, a fire may result. Clean it periodically. In addition, insert the plug in the wall outlet securely. Switch off the power, and unplug the power supply plug from the AC outlet for safety purposes when cleaning or leaving the unit unused for 10 days or more. Doing otherwise may cause a fire or electric shock.
An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in the electrical installation of the building.
T-6212
4
2. GENERAL DESCRIPTION The T-6212 is a high performance 10-zone Paging Selector that works with Emergency Panel (T-6203) and 10-zone speaker selector(T-6202),Paging microphone console(T-218) and Alarm Matrix(T-6225)for emergency notification and zone paging.The applications can be carride out with an amplifier stepping up the EMC input, MIC input and remote paging and then to trigger the speaker selector and Emergency Panel.Features include 10 zones paging and EMC(priority) input, two MIC inputs and two line inputs. Mute function, EMC priority, remote paging and built-in chime.
3. FEATURES =10 Channels. =Alarm activating. =2 MIC, 2 LINE input. =Chime & Mute function. =Remote-control available.
5
T-6212
4. NOMENCLATURE AND FUNCTIONS 4.1 FRONT PANEL
T-6212 PAGING SELECTOR POWER
PAGING ZONES
MIC 1 4
5
ON
2
OFF
1
2
2
1. POWER Power indicator 2. POWER SWITCH On top of the opening Power Press the end, power shut down 3. PAGING ZONES (1~10)Paging zones indicator (1~10)Paging zones button
3
4
5
6
3
7
8
9
10
6 7
2
8
8 1
9 0
5
3
7
1
1
MIC 2 4
6
3
9 0
10
4
10
CHIME
MIC 1
5
6
4. MIC (1~2) MIC (1~2) volume control 5. CHIME CHIME Microphone 6. MIC 1 MIC1 input 6.3 Microphone jack input
T-6212
6
NOMENCLATURE AND FUCTIONS 4.2 REAR PANEL
17
16
14
15
ALARM IN RISK OF ELECTRIC SHOCK DO NOT OPEN
AVIS:
+ 1
REMOTE IN
RISQUE DE CHOC ELECTRICUS -NE PAS QUVRIR
PUBLIC ADDRESS SYSTEM
- + 2
- + 3 -
+ 4
- + 5
- + 6
- + 7
- + 8
- + 9
- + 10 ~220V 50Hz T1AL250V
REMOTE OUT
SERIAL NO :.
ADDRESS TAG
+ A CHIME VOL
MIC 2 IN
7
8
LINE 1 IN
LINE 2 IN
9
AUDIO OUT
10
7. CHIME VOL CHIME volume control 8. MIC2 IN MIC2 input 6.3 Microphone jack input 9. LINE 1/LINE 2 IN Line Balanced inputs 10.AUDIO OUT Audio output 11.ALARM OUT Alarm activating output 12.SWITCH OUT Switching output
7
T-6212
- + B
ALARM OUT
11
- + 1
- + 2
- + 3 -
+ 4
- + 5
- + 6
- + 7
- + 8
- + 9
- + 10 -
SWITCH OUT
12
13
13.~220V /50Hz AC POWER INPUT 14.ALARM IN Alarm input 15.ADDRESS TAG Address for remote 16.REMOTE OUT Remote link output 17.REMOTE IN Remote input
5. MACHINE OPERATION MUTING FUNCTION Signal from MIC 2 and LINE 2 are automatically muted by signal from MIC 1 (MIC 1 input overrides MIC 2 and LINE 2 signals). Signal from MIC1, MIC2 and line2 are automatically muted by signal from LINE 1(LINE 1 input overrides the other input signals).
OPERATION 1 While press don any switch of CH1~CH10 on front panel with its indicator lit, the paging channel will be switching on respectively. Press the switch the switch again with the indicator getting off for resetting. 2 pin 1~10 of ALARM IN to be connected to fire center are the live terminals of CH1~CH10 respectively. And, +12V~24V high level or 0V-low level is available for alarm activating. While ACTIVE LEVEL set at HIGH, high level is valid; while ACTIVE LEVEL set at LOW, low level (grounded signal)is valid. 3 Witch address is for Remote only. If there are more than one T-6202 in Remote System, they must be addressed with different priority each other.
T-6212
8
9
PAGING MIC CONSOLE
RISQUE DE CHOC ELECTRICUS -NE PAS QUVRIR
RISK OF ELECTRIC SHOCK DO NOT OPEN
ADDRESS TAG COM
T-6212 LINE
ALARM OUT + ALARM IN -
RISQUE DE CHOC ELECTRICUS -NE PAS QUVRIR
RISK OF ELECTRIC SHOCK DO NOT OPEN
LINE 2 IN
AUDIO OUT
CHIME VOL
SERIAL NO :.
MIC 2 IN
PUBLIC ADDRESS SYSTEM
- + B
- + 1
+ 1
LINE 1 IN
ALARM OUT
+ A
ADDRESS TAG
RISQUE DE CHOC ELECTRICUS -NE PAS QUVRIR
RISK OF ELECTRIC SHOCK DO NOT OPEN
LINE 1 IN
AVIS:
MIC 2 IN
REMOTE IN REMOTE OUT
MIC 2
CHIME VOL
SERIAL NO :.
PUBLIC ADDRESS SYSTEM
AVIS:
- + 2
- + 2
+ 4
+ 4
- + 6
SWITCH OUT
- + 5
- + 6
ALARM IN
- + 5
- + 7
- + 7
LINE 2 IN
AUDIO OUT
REMOTE OUT
- + 8
- + 8
- + 9
- + 9
- + 10 -
- + 10 -
RISQUE DE CHOC ELECTRICUS -NE PAS QUVRIR
RISK OF ELECTRIC SHOCK DO NOT OPEN
PUBLIC ADDRESS SYSTEM
AVIS: SERIAL NO :
REMOTE IN
- + 3 -
- + 3 -
SPEAKER SELECTORS
MIC
IN 1-15
IN 16-30
EMERGENCY PANEL
SERIAL NO :
PUBLIC ADDRESS SYSTEM
AVIS:
ALARM MATRIX
~220V 50Hz T1AL250V
~220V 50Hz T1AL250V
~220V 50Hz T1AL250V
- + B
ALARM OUT
+ A
ADDRESS TAG
- + 1
+ 1
- + 2
- + 2
+ 4
+ 4
- + 6 SWITCH OUT
- + 5
- + 6
ALARM IN
- + 5
- + 7
- + 7
- + 8
- + 8
- + 9
- + 9
RISQUE DE CHOC ELECTRICUS -NE PAS QUVRIR
COM
INPUT B +
+ CH 1 -
ALARM B
ALARM A +
+ CH 2 -
MIC2
MIC3
EMC INPUT
MIC2
MIC3
LINE INPUT
AUX1
AUX2
OUT
AVIS:
RISQUE DE CHOC ELECTRICUS -NE PAS QUVRIR
RISK OF ELECTRIC SHOCK DO NOT OPEN
+ CH 6 -
70V 100V
OUTPUT
SERIAL NO:
PUBLIC ADDRESS SYSTEM
COM 4-16
MIC
LINE
ALARM OUT + ALARM IN -
+ 6 -
+ CH 7 -
ALARM OUT
+ 5 -
+ 6 -
ALARM IN
+ 5 -
EMERGENCY PANEL
MUTE
+ 4 -
+ 4 -
+ CH 5 -
+ 3 -
+ 3 -
+ CH 4 -
+ 2 -
+ 1 -
+ CH 3 -
+ 2 -
+ 1 -
MIXER AMPLIFIER
SERIAL NO :
PUBLIC ADDRESS SYSTEM
AVIS:
RISK OF ELECTRIC SHOCK DO NOT OPEN
INPUT A +
+ 7 -
SERIAL NO :
~220V 50Hz T1AL250V
~220V 50Hz
T5AL250V
~220V 50Hz T1AL250V
~220V 50Hz T1AL250V
RISQUE DE CHOC ELECTRICUS -NE PAS QUVRIR
RISK OF ELECTRIC SHOCK DO NOT OPEN
+ CH 10 -
PUBLIC ADDRESS SYSTEM
AVIS:
+ 9 - + 10 -
+ 9 - + 10 -
+ CH 9 -
+ 8 -
+ CH 8 -
+ 7 -
+ 8 -
- + 10 -
- + 10 -
SPEAKER SELECTORS
- + 3 -
- + 3 -
7. APPLICATIONS
REAR PANEL CONNECTIONS
8. SPECIFICATIONS
PAGING SELECTOR MODEL
T-6212
INPUT
MIC 1 2 600 Ohms,1.8mV,Unbalanced LINE 1 2 10KOhms, 200mV,Unbalanced
OUTPUT
80dB
FREQUENCY RESPONSE
MIC:100Hz~15KHz;LINE: 20Hz~18KHz
CROSSTALK
MIC input : 80dB;Line input: 90dB
CONTROLS
MIC 1,2 gain controls,10 channel selectors,chime button, powe switch
INDICATORS
Power LED,10 paging channel LEDs
PROTECTION
AC fuse, 1A
POWER REQUIREMENTS
110-120AC or 230-240V AC 50/60Hz 24DC (optional)
POWER CONSUMPTION
40W
DIMENSION(mm)
484X360X88
NET WEIGHT
5.2Kg
GROSS WEIGHT
6.4Kg
T-6212
10
9. DIMENSIONAL DIAGRAM UNIT :mm 484
T-6212 PAGING SELECTOR
MIC 1 5
4
MIC 2 4
6
3
3
5
4
8
9
- + 2
- + 3 -
7
6
10
6 7 8
1
9 0
5
2
8 1
2
1
3
7
2
OFF
9 0
10
94
PAGING ZONES
ON
88
POWER
10
CHIME
MIC 1
436 ALARM IN RISK OF ELECTRIC SHOCK DO NOT OPEN
AVIS:
+ 1
REMOTE IN
RISQUE DE CHOC ELECTRICUS -NE PAS QUVRIR
PUBLIC ADDRESS SYSTEM
+ 4
- + 5
- + 6
- + 7
- + 8
- + 9
- + 10 -
~220V 50Hz T1AL250V
REMOTE OUT
84
SERIAL NO :.
ADDRESS TAG
+ A
CHIME VOL
LINE 1 IN
MIC 2 IN
LINE 2 IN
- + B
- + 1
- + 2
- + 3 -
+ 4
- + 5
- + 6
- + 7
- + 8
- + 9
- + 10 -
SWITCH OUT
ALARM OUT
AUDIO OUT
335 330
84
25
6
Over 100
UNIT :mm
T-6212 PAGING SELECTOR POWER
PAGING ZONES
MIC 1 4
5
11
T-6212
1
2
3
4
5
6
7
8
9
10
8 9 0
10
5
6
3
7
2 1
Over 100
MIC 2 4
6
3
ON OFF
7
2
8 1
9 0
10
CHIME
MIC 1
Over 100
PUBLIC ADDRESS SYSTEM
AUDIO
Guangzhou ITC Electronic Technology Limited Http://www.itc-pa.com.cn 2008-02
Version1.1