Transcript
OWNER’S MANUAL Safety, Installation, Maintenance, and Operation
Model HV-60 Compressor Model SUH-132 Compressor Model SHD-132/70P Compressor
American Eagle, Inc. 740 N. State Street PO Box 169 Garner, IA 50438 800-392-3015 Fax: 641-923-9099 www.americaneagleacc.com Subject to Change without Notification. © 2015 American Eagle
Manual Part No. 40985 Last Revision: 10/28/15
Class 5 Compressor Manual Revisions Date of Revision 01/26/10
Section Revised Assembly Drawings
Description of Revision
Updated SHD-132/70P Compressor Assembly to reflect engineering changes.
Table of Contents
i
Introduction ...........................................................................................................................................ii Safety....................................................................................................................................................1 Specifications ......................................................................................................................................2 Compressor System Description .........................................................................................................2 SHD-132/70P Drive System Description ..............................................................................................2 General Specifications ........................................................................................................................2 Operation.............................................................................................................................................3 General Operation Notes ...................................................................................................................3 SHD-132/70P Operation Notes ............................................................................................................3 Maintenance .......................................................................................................................................4 Installation............................................................................................................................................5 Compressor Installation........................................................................................................................5 PTO and Pump......................................................................................................................................6 Compressor Assembly Mounting ........................................................................................................6 Electrical Connections.........................................................................................................................6 Hydraulic Routing .................................................................................................................................6 SHD-132/70P Control Kit .......................................................................................................................7 Typical Hydraulic Circuit for Single Stage Pump with Multiple Components ...............................8 Typical Hydraulic Circuit for Tandum (Two Part) Pump with Multiple Components ....................9 Typical Hydraulic Circuit for Compressor .......................................................................................10 with Auxiliary Cooler...........................................................................................................................10 Pressure Setting Instructions...............................................................................................................11 Assembly Drawings...........................................................................................................................12 Crankcase Group (Straight Shaft)....................................................................................................12 Cylinder Group ...................................................................................................................................13 Head Group ........................................................................................................................................14 Head Options......................................................................................................................................15 Flywheel Options ................................................................................................................................16 SUH-132 Compressor Assembly.........................................................................................................17 SHD-132/70P Compressor Assembly.................................................................................................18 SHD-132/70P Shroud Assembly..........................................................................................................19 Replacement Parts............................................................................................................................20 Troubleshooting ................................................................................................................................21 General Troubleshooting ...................................................................................................................21 SHD-132/70P Troubleshooting............................................................................................................22
ii
Class 5 Compressor Owner’s Manual
Introduction
American Eagle Compressors are designed to provide safe and dependable service for a variety of operations. With proper use and maintenance, American Eagle Compressors will operate at peak performance for many years.
This manual contains information vital to the safe use and efficient operation of this unit. Following the information provided within this manual can ensure the longevity of the compressor. Carefully read and study the operator’s manual before using the unit. Failure to adhere to the instructions could result in property damage or even serious bodily injury to the operator or others close to the compressor. A copy of this manual is provided with every compressor and shall remain with the compressor at all times. Information contained within this manual does not cover all maintenance, operating, or repair instructions pertinent to all possible situations. This manual is not binding. American Eagle reserves the right to change, at any time, any or all of the items,
components, and parts deemed necessary for product improvement or commercial/production purposes. This right is kept with no requirement or obligation for immediate mandatory updating of this manual.
This product manual is not intended as a training manual for beginners or unskilled operators. This manual offers guidelines for correct and safe usage of the compressor, maintenance, and troubleshooting. If more information is required or technical assistance is needed, please contact AE Technical Support.
Some sections of this manual contain information pertaining to all American Eagle manufactured compressors and may or may not apply to your specific model. If this manual becomes damaged, misplaced, or unreadable at any point, or if you feel that any part of this manual is unclear or incorrect, please contact AE Technical Support at 800-321-3741 or email at
[email protected]
For Technical Questions, Information, Parts, or Warranty, Call Toll-Free at
800-321-3741
Hours: Monday - Friday, 8:00 a.m. - 5:00 p.m. CST Or email at the following addresses: Technical Questions, and Information Order Parts
Warranty Information
[email protected] [email protected]
[email protected]
Safety
Safety
1
This manual contains vital information for the safe use and efficient operation of this unit. Carefully read the operators manual before starting the unit. Failure to adhere to the instructions could result in serious bodily injury or property damage. Every American Eagle Compressor will provide safe and dependable service if operated according to instructions. Read and understand the safety precautions given in this manual and on the decals attached to the shields. Failure to do so can result in personal injury or equipment damage. Operators and maintenance personnel must always comply with the safety precautions. These precautions are given here for your safety. Review them carefully before operating the compressor and before performing maintenance or repairs. Supervising personnel should develop additional precautions relating to the specific work area and local safety regulations.
Precautions Always wear safety equipment such as goggles, ear plugs and head protection at all times when operating the compressor.
Do not inspect or clean the compressor while the hydraulic power source is connected. Accidental engagement of the tool can cause serious injury. Before performing any maintenance on the compressor, place a warning tag on the hydraulic power source or disconnect the hoses from the compressor motor to prevent accidental startup of the compressor. Always connect hoses to the compressor
before energizing the hydraulic power source. Be sure all hose connections are tight, both air and hydraulic.
Establish a training program for all operators to ensure safe operation. Do not operate the compressor unless thoroughly trained or under the supervision of an instructor. Do not operate the compressor if it is damaged, improperly adjusted or not completely or properly assembled.
Never operate the compressor with any of the guards removed. Do not attempt to adjust or disable the compressors air pressure relief valve. This valve limits the air pressure to 150 PSI.
The surface of the air compressor and the plumbing between the compressor and the cooler may reach temperatures above 150 degrees. Touching these surfaces during operation can cause burns. The air taken in by the air compressor must be free of flammable fumes and vapors.
Compressor speed should not exceed 1300 RPM. Use and operate this air compressor only in full compliance with all pertinent O.S.H.A. requirements and all Federal, State and Local codes or requirements.
2
Class 5 Compressor Owner’s Manual
Specifications
Compressor System Description
• Cast Iron Crankcase Casting
• Heavy Ductile Iron Crankshaft
• High Temperature Precision Pistons
• Tapered Roller Bearings
• Cast Aluminum Cylinder Heads • Stainless Steel Reed Valves
• Heavy Duty Journal Bushings • Pulsation Manifold
• Micro-honed Connecting Rods • Pressure Lubricated System • Oil Pressure Gauge
SHD-132/70P Drive System Description
• 18 GPM Hydraulic System
• 2650 PSI System Pressure
• All Steel Plumbing W/ JIC Fittings
• 165 Sq. In., 300 BTU Cooler
• 3200 PSI Pressure Relief Setting • 861 CFM, 12 Volt Cooler Fan • Direct Drive Coupling
• Model:
• 12 VDC Solenoid Control Valve • 6061 Aluminum Manifold
• Air Pressure Control Valve
General Specifications
• Weight:
• Delivery:
• Maximum Working Pressure: • Dimensions: (SHD-132/70P)
HV-60
117 lbs (SHD-132/70P: 300 lbs) 70 CFM @ 100 PSI 150 PSI
31”L x 21”W x 22”H
• Electrical:
12 VDC
• Cylinders:
Four Cylinder(Single Stage)
• Oil Capacity: • Maximum Compressor Speed:
2 Quarts
1200 RPM
Operation
Operation
3
General Operation Notes
Each compressor is bench tested under load at the factory to ensure proper break-in and operation. While it is not necessary to follow any break-in procedure, the following checks should be made before putting the unit into service and periodically during use.
Before Start-Up
Check the oil level in the compressor with the dipstick on the unit. If oil is needed, use American Eagle synthetic compressor oil (P/N C0087) or an equivalent synthetic oil. Note: There may be oil left in the crankcase from the factory bench test. Overfilling may cause the compressor to back blow oil. Always check the oil level and fill to the designated marking on the dipstick before putting the unit into service. Check the air intake filters on each head to make certain that they are clean and unobstructed. Dirty air filters are a possible cause of reduced air output.
To use the compressor, start the engine and engage the hydraulic system with the compressor toggle switch. Through the hydraulic valve manifold, the system will now function automatically. Once engaged, adjust the engine speed control to ensure that the compressor speed does not exceed 1300 RPM under load.
SHD-132/70P Operation Notes If adjustment is necessary for cable operated speed controls, loosen the jam nut on the cable end, make the adjustment and retighten the jam nut.
For electronic operated speed controls, adjust speed adjustment screw as needed to set RPM. For setting engine RPM through the chassis ECM, contact local chassis dealer.
When the air pressure falls below 120 PSI, the 12 volt electric solenoid opens allowing hydraulic oil to flow to the hydraulic drive motor then back to the manifold and through the oil cooler assembly. Once the air pressure reaches 150 PSI the solenoid closes shutting off the oil flow to the motor and diverts the oil to the oil cooler. With the compressor engaged, the main cooling system, which consists of an oil cooler, electric fan motor and fan continually runs drawing ambient air through the cooler fins and across the fan assembly discharging heated air past the compressor and out the cover assembly.
4
Class 5 Compressor Owner’s Manual
Maintenance
The following table is a list of routine maintenance items, including service intervals. Service intervals are listed as hours, days, or weeks, whichever occurs first. American Eagle recommends that these service intervals be followed. Maintenance operation
Service Intervals
Drain air tanks
Daily
Weekly
Monthly
Hourly
Check crankcase oil level Check fittings and airlines
Check hydraulic fluid level
Inspect and clean air intake filters Clean and operate safety valves Clean cooling fins on radiator Inspect check valve
Inspect and clean compressor valves
6
Replace air filters
3
Replace hydraulic filter
Tighten all fittings and fasteners
Check all electrical connections Check compressor reed valves
Inspect and clean air check valve
CHANGE CRANKCASE OIL (see footnote below)
6 3
3
250 250
Under normal operating conditions, oil changes are required every 3 months. When operating in a dirty environment, change the oil more frequently as your particular operating condition dictates.
USE AE SYNTHETIC COMPRESSOR OIL P/N C0087. COMPRESSOR CRANKCASE CAPACITY IS 2 QUART.
General preventative maintenance includes maintaining proper fluid level in both systems and the general cleanliness of the equipment. Proper fluids according to the specifications are required.
Installation
Installation
Compressor Installation
Component Installation This section pertains to the installation of the air compressor, PTO, pump and other related items. The instructions are intended as a guide to assist you with particular installation. These instructions will provide only general information. Pulsation Chamber Assembly
Torque and Procedure Chart
Torque Value: 31 FT. LBS.
Procedure: See Head Installation Procedure Section Head Assembly
6
5
Torque Value: 34 FT. LBS.
Procedure: Assemble head on the cylinder with head bolts started only, not tight. Working in the pattern shown, torque three times, increasing the torque each time as follows:
2
First Torque: 10 FT. LBS. Second Torque: 20 FT. LBS. Third Torque: 34 FT. LBS.
1
After five hours of use re-torque bolts to 34 ft-lbs. Cylinder Assembly
3
4
Torque Value: 20 FT. LBS.
Procedure: After assembling cylinder over pistons and setting into place, tighten (6) cap screws finger tight. In a criss-cross pattern, tighten bolts evenly so all bolts are hand snug. Again in a criss-cross pattern torque each bolt to 20 Ft-lbs., checking each bolt twice. After five hours of use, re-torque bolts to 20 Ft-lbs. Connecting Rod Assembly Torque Value: 18 FT. LBS.
Procedure: Assemble rod onto the crankshaft taking care to align the machined surfaces together and tighten cap screws finger tight. Tighten bolts until hand tight and torque to 18 Ft-lbs. Check twice the torque reading before final assembly of the cylinders.
5
6
Class 5 Compressor Owner’s Manual
PTO and Pump
Pump Assembly: The pump assembly may either be installed directly on the PTO or as an optional method, may be driven by a driveline from the PTO. Pump manufacturers provide specific installation information for their products and should be consulted if questions arise. PTO Assembly: Check with the PTO manufactures representative for specific instructions regarding your particular make, model, and year of vehicle. As some trucks may require modification of the transmission cross member and the exhaust system, the manufacturer’s instructions should be followed to insure proper installation of the PTO.
Compressor Assembly Mounting
Compressor Assembly: Prepare the mounting location of the compressor by locating and drilling four (4) holes, 1/2” diameter as per the mounting pattern of the air compressor base. Using four (4) 3/8” x 1.25 GR-5 cap screws, 3/8” lock washer, and 3/8” nyloc nut, secure the compressor in place. The compressor is air cooled, and must have a clean supply of cooling air to the fan with minimum restrictions. Adequate space must be provided for proper circulation of air.
Electrical Connections
Electrical Connections: From the air pressure switch there are two (2) wires, red and black, running to the outside of the compressor housing. Connect the black wire to the vehicle frame or other suitable ground. Mount a single throw toggle switch in a convenient location and connect the red wire from the compressor to this switch. Connect the other switch terminal to a fuse holder and then to a 12-volt power supply. A third wire is required from the air compressor switch when connecting the speed control into the system. Note: Fan Fuse is 25 amp and System Fuse is 30 amp. See Control Kit drawing later in this section for more details.
Electric speed control: An optional electric or electronic speed control must be used to maintain proper operating speed of the air compressor. The engine speed control will automatically increase from idle to preset speed when engaged and decrease when disengaged. The electric cable pull speed control (American Eagle P/N 25740) is used on most gasoline engines. The electronic speed controls are used only on Ford 7.3 and 6.0L diesel engines. Proper installation instructions are provided with each system.
Hydraulic Routing
Hydraulic System: The hydraulic system consists of the pump, oil reservoir, filters and Return Line hoses. Installed on the compressor is a valve block assembly that controls the flow to the hydraulic motor. To this block, a 1/2” highPressure pressure hose must be attached. This hose comes from the hydraulic Line pumps pressure side. A 3/4” minimum low-pressure return line is connected to the oil cooler outlet and is routed to the oil reservoir. American Eagle recommends a sufficient sized reservoir be provided which includes the proper suction and return filters. The cooler on the compressor is designed and sized to cool the air compressor efficiently. An auxillary oil cooler is required when additional hydraulically operated equipment are added to the hydraulic system. Pressure on the return line exceeding 200 PSI can and will cause damage to the filter, cooler, and components of the compressor hydraulic system. Note: See hydraulic circuit drawings later in this section for details.
SHD-132/70P Control Kit
Installation
7
8
Class 5 Compressor Owner’s Manual
Typical Hydraulic Circuit for Single Stage Pump with Multiple Components
Installation
9
Typical Hydraulic Circuit for Tandum (Two Part) Pump with Multiple Components
10
Class 5 Compressor Owner’s Manual
Typical Hydraulic Circuit for Compressor with Auxiliary Cooler
HYDRAULIC RESERVOIR
FILTER SCREEN
FILTER
AUXILIARY COOLER SUCTION PORT
SINGLE HYDRAULIC PUMP
COMPRESSOR RETURN
PRESSURE
Pressure Setting Instructions
Kick On (Step 2) Pressure Setting Adjustment Screw (115-120 psi)
Installation
Kick Out (Step 1) Pressure Setting Adjustment Screw (145-150 psi)
-
+
-
+
Note: Turning adjustment screws clockwise increases psi settings. Turning adjustment screws counterclockwise decreased psi settings.
Pressure Setting Instructions: 1. Always set the kick out pressure setting first. 145 psi minimum/150 psi maximum. 2. After kick out pressure is set, adjust the kick on screw setting at 115 psi minimum/120 psi maximum. 3. Cycle compressor to verify correct settings. 4. For questions about this procedure, please contact Stellar Customer Service.
11
12
Class 5 Compressor Owner’s Manual
Assembly Drawings
Crankcase Group (Straight Shaft) 20 13
15 35
26
23
24
21
8
19
10
7
9
4
9 33
34
17
11
5 8
18
2 1 39 29
26
28
12
16
3
6 22
27 32
14
38 37 31 30
36
25
CRANKCASE GROUP ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
PART 0351 0353 0485 5817 5819 11878 11885 11888 11889 11890 11891 11893 21659 22209 22210 22626 22686 23050 23368
DESCRIPTION CAP SCR 0.38-16X1.00 HHGR5 CAP SCR 0.38-16X2.00 HHGR5 CAP SCR 0.31-18X1.25 HHGR5 ROLL PIN 0.19X.50 GAUGE OIL PSI 1.5 CRANKCASE HV60 BREATHER BAFFLE HV60 BEARING CUP HV60 BEARING CONE BEARING SEAL HV60 BEARING CARRIER GASKET .015 HV60 BEARING CARRIER HV60 REDU BUSHING 0.75X0.38 BRASS ROLL PIN 0.19X.63 DIPSTICK OIL CHECK V480 PORT PLATE COVER HANDLE DIPSTICK OIL CHECK V480 DIPSTICK BODY (200) CRANKSHAFT HV60
QTY.
4 1 4 1 1 1 2 2 2 1 7 1 2 1 1 1 1 1 1
ITEM 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34
PART 23483 23669 23685 26033 26034 50389 C0041 C0050 C0052 C0054 C0055 C0057 C0058 C0059 C0060
35
C1054
36 37 38 39
C4841 C5416 C6273 C6275
DESCRIPTION QTY. BREATHER CPRSR .38NPT BF6 2 KEY FLYWHEEL 3/8 X 2 1 DIPSTICK ROD HV60 1 CAP SCR #10-24X1.00 SH 2 NUT #10-24 HH NYLOC 2 WASHER 0.885X1.115X0.064 COPPER 1 O'RING-112 2 OIL PUMP 1 PORT PLATE MACHINED 1 PORT PLATE COVER GASKET (SMALL) 1 OIL INTAKE PLUG 1 O'RING 2-115 FOR OIL PICKUP TUBE 1 OIL INTAKE FILTER SCREEN 1 OIL PUMP TRANSFER BUSHING 1 SPRING OIL PUMP 1 FTG 12-12X6.00 MP-MP NIPPLE STRAIGHT 2 BLK PLUG 0.38 NPT SQ HD BLK 1 TUBE OIL INTAKE .38ODX3.00 1 SNAP RING PISTON PIN N5000-62 1 PORT PLATE GASKET 1
Assembly Drawings
Cylinder Group 7 3
6
11
4 5
10 9
5
12 1
8 12 2
CYLINDER GROUP ITEM 1 2 3 4 5 6 7 8 9 10 11 12
PAR T 11907 23 369 11877 2 337 0 23481 0523 0335 23043 23044 23042 11884 36 369
DE S C R I P T I O N C O N N E C T IN G R O D H V 6 0 O / S P IST ON HV 60 CYLINDER HV60 PISTON PIN HV60 SNAP RING PISTON HV60 W A S H E R 0 .3 8 L O C K CAP SCR 0.38-16X1.25 HHGR5 RI NG OI L H V 60 FL E X D I V I DE R R IN G C OM PRESSI O N LOWER HV 6 0 RI N G C O M P R E S S I O N U P P E R H V 6 0 GASKET CYLINDER BASE HV60 R I N G O IL H V 6 0 R I N G R A I L
QTY. 2 2 1 2 4 6 6 2 2 2 2 4
13
14
Class 5 Compressor Owner’s Manual
Head Group
8
9 7
6
15
17
5 12 11 13 10
4 3
2
1
HEAD GROUP ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
P AR T 998 0 11897 9979 1 18 9 4 C1586 C0040 5828 11 8 98 11886 1 1 9 00 1 19 01 1 19 03 11902 6684 C0291 2 38 75 26 03 2
14
16
DE S C R I P T I O N G A S K E T CY L H E A D HV - 60 V A L V E P L A T E A S S E M B L Y H V6 0 G A S K E T C Y L H E A D ( V AL V E P L A T E ) H V - 6 0 H E A D A / C H V 60 C A P S C R 0 . 3 8 -1 6 X 1 . 7 5 S H H E A D B O L T WASHER HD BOLT STL WAS HER LONG H D BOLT (B RAS S) CA P S CR 0. 3 8-16X3 .75 SH H EAD BO LT CAP SCR 0.25-28X0.88 SH FI L T E R R E T A I N E R H V 6 0 F I L T E R I N N ER E L E M E N T H V 6 0 FILTER SCREEN HV60 FILTER OUTER ELEMENT HV60 CA P SC R #1 0-32X0 .50 SH O'RING-214 VITON 9009-75 W A S HE R #1 0 S T AR C PR S R W AS H E R 0 . 255 I D B R A S S
4
QTY. 1 1 1 1 4 1 1 2 2 1 1 1 1 3 1 3 2
2
1
5
3
ITEM 1 2 3 4 5
MANIFOLD DISCHARGE
PA RT 23 4 8 6 D1292 5 7 97 6000 559 6
DESCRIPTION M A N I F O L D H V 6 0 D I SC H A RG E O / S C AP S C R 0 . 4 4 - 1 4 X 1 . 2 5 S H G R 5 B L K DRAIN COCK-V480 PLUG 0.75 NPT SQ HD CS BLK PL U G 1. 0 0 NP T S Q H D C S B L K
QTY. 1 4 1 1 1
Head Options
#11894 Aluminum Air Cooled Imbedded Filter & 1” Threaded NPT Discharge
#11896 Aluminum Air Cooled 1” Threaded Inlet & 1” Threaded NPT Discharge
Assembly Drawings
#11895 Aluminum Water Cooled Imbedded Filter & 1” Threaded NPT Discharge
#10381 Aluminum Water Cooled 1” Threaded Inlet & 1” Threaded NPT Discharge
15
16
Class 5 Compressor Owner’s Manual
Flywheel Options
28688 14” B-DUAL GROOVE
17
Assembly Drawings
SUH-132 Compressor Assembly
COMPRESSOR ASSEMBLY ITEM 1 2 3 4 5 6
PART 10365 24096 4555 D1450 10155 D1273
DESCRIPTION CPRSR HV60W 88NP NIPPLE 1.00X5.00 SS 304 ELBOW 1.00 90 DEG BRASS NIPPLE 1.00XCLOSE BRASS 40-100 UNLOADER-CHECK VALVE NL-14 CONRDR FTG 1.00-0.75 BUSH RED BRASS
QT Y . 1 1 1 1 1 1
ITEM 7 8 9 10 11
PART 10082 C2236 C6235 25450 C4665
DESCRIPTION MUFFLER EXHAUST AIR 0.50 NPT 1A328 FTG .75-.50 BUSH HEX BLK FTG BRASS ELL 90 DEG A/C HOSE 0.63X18.00 HOSE CLAMP #8 SS
QT Y . 1 2 2 1 2
18
Class 5 Compressor Owner’s Manual
SHD-132/70P Compressor Assembly 67
24 10
55
44
54
53
44
53
52
39 53
65
11
56 30
8 24
69
51
87
16
75
12 82
86 66
13
84
74 89 71
41
15
47
61
4
23 45
19
25
85 37
83
57
14 80
38
39 78
60
35 88
68
48
79
47
70
49
39
26
51 49 63
77 62
49 77
85
22
50
49
58
6
5
33
32
81
7
38
44
42 41
3
21
49 43
17 64
20
48
28
40 39 73 72
2
36
76
49
9
42
34
51
49
25
31 18
27
46
29
1 ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
PART DESC RI P TION BASE WLDMT SHD132 BULKHEAD PC 70735 BLACK 30236 CPRSR HV60A88NP 71374 KEY FLYWHEEL 3/8 X 1.125 10078 COUPG 3/8 KW L150 1.438 D0793 COUPG SPIDER L150-U BLUE URETHANE D0791 COUPG 1/4 KW L150-0.75 27718 MOTOR MNT SHD132 10081 MACHINED C1129 COOLER OIL 24 GPM MAX FLOW 10084 FAN 12.00 PULL 12 VOLT 132A COMP D0075 SCREW #6-32X2.75 RH HD MACHINE D0076 NUT #6-32 HH NY LOC C0863 SWITCH PRES COMPRESSOR C5616 CLAMP R OMEX 0. 50 4570 MOTOR HYD M3000A731SPLZA15-32 MOUNT PLATE BULKHEAD CPRSR SHD132 70737 PC WHITE 70738 SHROUD ASM CPRSR SHD132 65025 FTG 12-12 MFS-MFS BULKHEAD UNION D1318 FTG BULKHEAD 8WLO-WLNL-S 28855 HOUR METER 12VDC TST 180-1911 20451 FTG 2-2 MP-FP STREET ELBOW 90 BRASS 20452 FTG 6-6 FP-FP ELBOW 90 BRASS 20325 PLUG 0.38 NPT SQ HD BRASS FTG 6-6X4.00 MP-MP NIPPLE STRAIGHT 20456 BRASS C5968 FTG 12-12 MFS-MAORB 90 C2053 FTG ADAPT 6-8 F5OLO-S MANIFOLD ASM SVRV10-12SAE 3500PSI 70472 ALUM BODY C4909 FTG TEE SL LOK 8-S5OLO-S D0525 FTG 12-12-12 MFS-FFSS-MFS RUN TEE 70749 TUBE ASM 0.50 BLKHEAD TO MANIFLD SHD132 YZ TUBE ASM 0.75 COOLER TO BLKHEAD 70753 SHD132 YZ D1299 FTG BULKHEAD 6WLO-WLNL-S 55200 FTG 6-4 MFS-MP 90 72382 FILTER MANIFOLD SHD132 1INCH OUTLET
QT Y. I TEM 34 1 35 1 36 1 37 1 38 1 39 1 40 1 41 1 42 1 43 2 44 2 45 1 46 1 47 1 48 1 49 1 50 1 51 1 52 1 53 1 54 1 55 1 56 1 57 58 2 59 2 60 1 61 1 62 1 63 1 64 1 65 1 1 1
66
PART 70 7 57 70759 34498 70760 0345 05 2 3 C0944 C6021 19592 22183 5290 22186 0438 05 2 1 0479 0340 0483 0333 0335 0346 0347 0351 C6022 73722 0535 70764 70764 19589 18611 70765 21393
DESC RIP TI O N FILTER AI R SHD1 3 2 BRKT AIR FILTER MNT SHD132 PC BLACK FTG 16-16 HB-MAORB 45 FT G 1 6 -1 6 H B- M P 9 0 CAP SCR 0.38-16X1.50 HHGR5 WASHER 0.38 LOCK CAP SCR 0.38-16X1.75 HHGR5 CAP SCR 0.25-20X0.75 BTNHD SS WASHER 0.25 FLAT NYLON SCREW #8-32X0.75 BTNHD SS WASHER #8 SAE FLAT ZINC NUT #8-32 HH NYLOC SS CAP SCR 0.25-20X2.25 HHGR5 WA S H E R 0 . 25 L OC K CAP SCR 0.25-20X0.75 HHGR5 WASHER 0.25 USS FLAT ZINC CAP SCR 0.25-20X3.50 HHGR5 NUT 0.25-20 HHGR5 NYLOC CAP SCR 0.38-16X1.25 HHGR5 WASHER 0.38 USS FLAT ZINC NUT 0.38-16 HHGR5 NYLOC CAP SCR 0.38-16X1.00 HHGR5 CAP SCR 0.25-20X1.00 BTNHD SS STUD 0.50-13X2.00 SELF LOCKING NU T 0 .3 8-16 HH GR5 HOSE SUCTION 1.00X16.00 HOSE SUCTION 1.00X16.00 NUT SERT 0.25-20X0.38 OD SCREW #6-32X0.38 HH MACH SELF TAP BRKT HYD VALVE MNT SHD132 PC BLACK FTG 12-12 FP-MJ BULKHEAD STRAIGHT BRKT COOLER MOUNT SHD132 V2 PC 73363 BLACK HOSE STEAM 0.75-12FJ SHORT-12MP 72383 SHORT-23CL
Q T Y . IT EM 67 1 68 1 2 69 2 70 5 71 10 72 3 73 8 74 8 75 2 76 8 2 77 2 78 4 79 4 80 14 81 2 82 6 83 4 84 10 85 4 86 2 87 2 88 4 89 1 1 1 2 2 1 1 1 1
P A R T DESCR IP T ION c 4 9 0 3 FTG 1 2 - 12 M FS- F F S S 9 0 C2142 FTG 12-12 MFS-MORB STRAIGHT HOSE 0.75(3000PSI)-12FFSS SHORT-12FFSS 73646 90 SHORT-8.25CL 7351 FTG ST TH ELBOW 45 DEG 12V5OLO 73647 FTG 16-12 MP-MP HEX NIPPLE STRAIGHT 5480 VALVE CHECK 0.75 STANDARD D1267 FTG .75X90 DEG ST EL BRASS 44164 60 187 FTG 4-4 MP-CR P S N 90 TUBING COPPER SHD132 CPRSR 74090 BULKHEAD HOSE 0.75(3000PSI)-12FFSS SHORT-12FFSS 73649 90 LONG-12CL
52474 FTG HOSE 6-6 FFSS-CRP PUSHLOCK SHORT 73650 HOSE HYD 0.38X24.00 MULTIPURPOSE PUSHLOCK C0082 CLAMP 0.75 BLK VINYL 73651 HOSE 0.50(3000PSI)-8FFSS SHORT-8FFSS 90 LONG-8.50CL C0081 CLAMP 0. 50 BLK VINYL 73652 PLUG NICKEL PLATED BUTTON 0.88 61470 NUT 0.50-13 HHGR8 DISC LOCK 8276 FTG 4-2 MP-MP 90 C4 6 59 H OSE CLA MP # 16 S S 74091 BRKT LIFTING CPRSR SHD132 PC BLACK 12122 BOLT 0.38X1.00 EYE 567-23-ZN 1554 FTG 8-8 MFS-MORB STRAIGHT C2220 FTG 12-4 MP-FP REDUCER BUSHING
Q TY. 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 4 1 4 1 1 1 1
Assembly Drawings
SHD-132/70P Shroud Assembly 6 8
3
2 5
9
10 12
14 9
17
13
15
13 12
12
16 13 12 9 10
11 1
7
4
9 10
ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PART 70747 70741 73655 70740 70739 70748 70379 69101 C6021 19592 19589 0333 D0917 0342 73653 6 9 10 3 73654
DESCRIPTION PANEL FRONT CPRSR SHD132 SHROUD PC WHITE PANEL BACK CPRSR SHD132 SHROUD PC WHITE WEATHERSTRIP RIBBED 0.38X0.13X105.00 PANEL SIDE RH SHD132 SHROUD PC WHITE PANEL SIDE LH SHD132 SHROUD PC WHITE PANEL LID CPRSR SHD132 SHROUD PC WHITE HINGE ZINC BLK FLUSH SURFACE MNT DC-50-P8 LATCH SWING LEVER FLUSH TRIGGER 0.91-1.81 C A P S C R 0.2 5 -20 X0. 75 B T N HD SS WA SHER 0.25 FLA T NYLON NUT SERT 0.25-20X0.38 OD NUT 0.25-20 HHGR5 NYLOC WASHER 0.25 FLAT SS NUT 0.31-18 HHGR5 NYLOC BRKT LOWER GASPROP CPRSR SHROUD V2 PC WHITE G AS S P R I NG 7 .5 0 -12 . 0 0 3 0 # F O R CE BRKT LID GASPROP CPRSR SHROUD V2 PC WHITE
Q TY. 1 1 1 1 1 1 2 1 22 18 12 18 18 4 2 2 2
19
20
Class 5 Compressor Owner’s Manual
Replacement Parts
Replacement Part
Overhaul Kit - P/N: 24098 Consisting of:
Gasket Set (1) Ring Set (1) O-Ring (2) Valve Plate (2) Bearing Oil Seal (1) Oil- 2 Qt Inner Filter (2) Outer Filter (2)
Gasket Set Complete - P/N: 11876 Ring Set Complete - P/N: 11906 Valve Plate Assembly - P/N: 24097 Consisting of:
Valve Plate (1) Top Head Gasket (1) Bottom Head Gasket (1)
Crankshaft With Bearings: Straight Shaft - P/N: 11887 Canister Filter - P/N: 22867
Call 800-321-3741 to Order
20
21
Troubleshooting
General Troubleshooting
Problem
Possible Cause
Solution
Compressor does not run
No 12 Volt Power to Compressor Air reservoir full Hydraulic lines not connected Couplers or hoses blocked Air load against compressor Hydraulic pump not working Hydraulic motor not working Check valve leaking
Check Fuse Drain and activate pressure switch Connect lines Locate and remove restriction Relieve air pressure Check flow and pressure settings Inspect and repair Disassemble, clean, and reinstall or replace
Compressor runs hot
Compressor runs too slow
Compressor will not stop Air output too low (air pressure okay) Compressor cycles (air not being used) Air Output low (Air Pressure Low) Air pressure too low
Air pressure too high High crankcase oil usage Blowing oil from crankcase breather No lubricating oil pressure
Check compressor rotation Compressor reed valves Dirty intake filter Low oil Level Check valve leaking
Compressor reed valves Check for hose leaks Hydraulic flow too low Hydraulic motor worn Power unit relief set too low Hydraulic system too hot Speed control not working
Air pressure switch set wrong Leaking hoses or fittings Low compressor speed Air filter dirty Airlines leaking Check valve plugged
Leaks in air line Air pressure switch set wrong Dirt in solenoid valve
Dirty air filter Intake reed valves malfunction
Insufficient torque on head bolts
Air pressure switch set wrong Air line leak Air consumption exceeds Compressor capacity Intake or exhaust valves damaged Pressure switch not operating Internal contamination Pressure switch not adjusted Oil level too high Oil leaks Piston rings worn or broken
Blown head gasket Piston rings worn or broken Oil level in crankcase too high Hole in piston Air lock in oil pump
No oil in crankcase Pump suction blocked
Check fittings on hydraulic motor Inspect, clean or replace valves Clean filter assembly Level Add oil if needed Disassemble, clean, and re-install
Inspect, clean or replace valves Tighten any hose fitting leaking Check and reset flow Replace with new motor Readjust relief valve Reservoir too small. Add cooler to system. Check power supply and readjust Check points and setting on switch Tighten all fittings and hoses Refer to compressor too slow Clean or Replace Filters Retighten hoses Remove and clean check valve
Tighten hoses and fittings Check cut-in and cutout settings Remove and clean
Inspect and clean filter If air back-flows from air filter, reed valve is faulty and needs to be replaced. Tighten bolts to required torque Readjust high pressure setting Inspect and tighten loose hoses Check air demand for items using the air supply Inspect and replace
Inspect and clean Inspect and clean Readjust to lower pressure
Check oil level and drain if needed Inspect and repair gaskets or seals Replace rings Replace gasket Replace rings Check oil level and drain Replace piston
Loosen oil gauge while compressor is running. When oil begins to flow from fitting, tighten oil gauge. Check oil level and add Remove oil intake plug and inspect intake and screen. Clean blockage.
22
Class 5 Compressor Owner’s Manual
Troubleshooting
22
SHD-132/70P Troubleshooting
If symptoms of poor performance develop, the following chart can be used as a guide to investigate and correct the problem. When diagnosing faults in operations of the air compressor, always check that the hydraulic power source is supplying the correct hydraulic flow and pressure that is listed in the compressor specification section of this manual. Note: To Operate, the American Eagle SHD-132/70P Compressor needs 10 GPM and 1800 PSI System Pressure. Problem
Possible Cause
Solution
Note: When checking hydraulic pump flow, make sure the air tank is closed and the compressor is running.
Faulty Hydraulic Pump.
If the pump pressure is below the recommended GPM, replace the Hydraulic pump if necessary.
Compressor will not operate:
Air receiver is full.
Compressor locks up at 110 psi and higher while under load:
Weak Hydraulic Motor.
Oil Pressure is low.
12 Volt power is not going to the line side of the pressure switch. Faulty Pressure Switch. Hydraulic Lines not installed correctly. Air Couplers or hoses are blocked. Inline Check-Valve is leaking. Faulty Solenoid Valve.
Compressor is locked up.
Hydraulic motor malfunctioning.
Hydraulic pump malfunctioning.
If the Hydraulic pump is supplying the recommended amount of fluid to the hydraulic motor, replace the hydraulic motor.
If the oil pressure gauge is reading in the red area, the oil pressure is low. See the Low Oil Pressure entry in this troubleshooting section. Drain and activate pressure switch.
If there is no power going to the line side of the pressure switch, trace the wire back to the power source.
If there is no power going to the solenoid valve, replace the pressure switch. Reinstall hydraulic lines.
Locate and remove restriction.
Disassemble, clean, and reinstall or replace.
If there is power going to the pressure switch, press down on the solenoid valve bypass button. If the compressor starts to operate, replace the solenoid valve. Remove the coupler and lovejoy between the compressor pump and the hydraulic motor. Turn the compressor over by hand. If the compressor turns over freely, the pump is ok. This indicates there is a possible hydraulic problem. Inspect and repair.
Check flow and pressure settings.
23 Problem
Compressor runs hot:
Possible Cause
Solution
Low oil Level.
Add oil if needed.
Dirty intake filter. Inline check-valve leaking.
Blown Head or Reed Valve Gasket. Compressor runs too slow:
Malfunctioning reed valve.
Speed control not working. Check for air hose leaks.
Hydraulic system too hot.
Power unit relief set too low. Hydraulic motor worn.
Hydraulic flow too low. Compressor hesitates or stumbles at restart (115 PSI):
Malfunctioning reed valves. Weak Hydraulic Pump.
Note: Compressor kicks out at 150 PSI and kicks back in at 115 PSI
Weak Hydraulic Motor.
No lubricating oil pressure:
No oil in crankcase.
Pump suction blocked. Air lock in oil pump. Oil pump pin is broken.
Malfunctioning oil pump.
Clean filter assembly. Disassemble, clean, and re-install. Replace Gasket.
Inspect, clean or replace valves.
Check power supply and readjust. Tighten any hose fitting leaking.
Reservoir too small. Add cooler to system. Readjust relief valve.
Replace with new motor. Check and reset flow.
Inspect, clean, or replace valves.
If the hydraulic pump pressure is below the recommended GPM to the hydraulic motor, the hydraulic pump could be weak and needs to be replaced. If the hydraulic pump is supplying the recommended GPM to the hydraulic motor, the hydraulic motor could be weak and needs to be replaced. Add oil.
Remove oil intake plug and inspect intake screen. Clean blockage.
Loosen oil gauge while the compressor is running. When oil begins to flow, tighten the gauge. Replace pin.
If the oil pressure gauge indicator is reading in the red area, use a 1/4” lock washer and point it flat. Remove the oil pump housing cover and place the lock washer inside the oil pump transfer bushing so it is between the pump spring and the transfer bushing. If oil pressure is still low, add one more lock washer. If two lock washers don’t increase the oil pressure, replace the oil pump.
24
Class 5 Compressor Owner’s Manual
Problem
Air Output low: (Air Pressure Low)
Air pressure too low:
Air pressure too high:
Possible Cause Dirty air filter.
Inspect and clean filter.
Intake reed valves malfunction.
If air back-flows from air filter, reed valve is faulty and needs to be replaced.
Insufficient torque on head bolts.
Air line leaking.
Air consumption exceeds Compressor capacity.
Blowing oil from crankcase breather:
Check air demand for items using the air supply.
Pressure switch not functioning correctly.
Inspect and clean.
Pressure switch not adjusted correctly. External oil leaks.
Oil level too high.
Piston rings worn or broken.
Oil level in crankcase too high. Blown head gasket.
Piston rings worn or broken. Compressor will not stop:
Inspect and tighten loose hoses.
Readjust high pressure setting.
Intake or exhaust reed valves damaged.
Hole in piston.
Air pressure switch set incorrectly . Leaking air hoses or fittings.
24
Tighten bolts to required torque.
Air pressure switch set incorrectly.
Internal contamination.
High crankcase oil usage:
Troubleshooting
Inspect and replace.
Inspect and clean. Readjust to lower pressure.
Inspect and repair gaskets or seals.
Check oil level and drain if needed. Replace rings.
Check oil level and drain. Replace gasket. Replace ring.
Replace piston.
Check points and setting on switch. Tighten all fittings and hoses.
25
26
Class 5 Compressor Owner’s Manual