Oil-Less Compressor Installation For models: O21, O22, O62, O82
Step 1: Remove compressor and accessories from shipping skid.
Step 3: Move compressor to a dry, well ventilated area on a solid, level surface. Note: Verify compressor is level by observing bubble level on saddle. Temperature of room 40° (4°C) min. - 100° (38°) max.
Bubble Level
Drain Canister
Step 5: Install canister
O62 Model Shown
tubing. AA148900i
Step 2: Install feet.
Step 4: Connect air line to office air supply line.
© Midmark Corporation 2005 Style G
1
003-1545-00
Rev. (B)
Back
Next
Step 6: Mount fresh air intake manifold. Connect to air source and compressor intake mufflers. Note: Mount no more than 3’ above compressor suction intake(s).
Equipment Alert Tight bends will cause hose to collapse and lead to compressor failure. To prevent moisture from entering the compressor, remote fresh air intake air temperature must not exceed compressor room air temperature by more than 20°. If necessary, route the intake to a source inside the building away from the compressor room.
Twin Head Compressors - O62 & O82
Single Head Compressors - O21 & O22 To Acceptable Air Intake Source
To Acceptable Air Intake Source
1 /1/2” PVC Pipe
2” PVC Pipe 2 “x 1/2” Bushing
Wall Bracket 1 1/2” x 1/2” Bushing 1/2” Hose Barb Adapter
1 1/2” Tee 1/2” Hose Clamp
Wall Bracket 2” Cross 1/2” Hose Clamp
1/2” Hose Barb Adapter
1/2” Nylon Braid Hose (5’ Max Length)
1/2” Nylon Braid Hose (5’ Max Length) 2” Tee
To Muffler on Each Compressor Head
To Each Muffler on Compressor Head
AA149400i
Fresh Air Intake
AA149200i
O62 Model Shown
© Midmark Corporation 2005
2
Color Page
Back
Next
Step 7: Connect open conduit to field wiring.
Refer to Specification Sheet for Electrical Ratings
Note: Use compressor starter contactor for remote low voltage control.
Low Voltage Control - Starter Contactor
230 Volt CSC Unit
115 Volt CSC Unit
BLU
BLU
BLU
BLU
WHT
FUSE
FUSE WHT
BRW
YLW
BLU
BRW
BLU RED
RED
24V
24V 24V
120V
230 V
WHT
WHT BLU
BLU
TRANS.
TRANS.
WHT
WHT ORG
ORG
BLK
1
2
3
4
24 V
5
BLK
6
7
8
1
2
3
4
5
6
7
8
YLW
AA148400i
Note:
Note:
115 Volt units, place jumper on number 3 and 4 terminals.
© Midmark Corporation 2005
230 Volt units, place jumper on number 2 and 3 terminals.
3
Back
Color Page
Next
Models O21 & O22 Electrical Wiring Diagram Single Compressor Oil-less (1) 3/4 HP Single Phase (1) 1 HP Single Phase (1) 1-1/2 HP Single Phase (1) 2 HP Single Phase
L1 TOP OF SWITCH PRESSURE SWITCH
L2 SWITCH DPST
BLACK JUMPER WHITE L2
BLACK
L1
GRAY
MOTOR
M1 M2
WHITE
GRAY JUMPER
RUN
START SV
Model O62 & O82 Electrical Wiring Diagram Twin Compressor Oil-less (1) 3/4 HP Single Phase (1) 1 HP Single Phase (1) 1-1/2 HP Single Phase (1) 2 HP Single Phase
L1 L2
BLACK
MOTOR WHITE
BLACK JUMPER
RUN
BLACK WHITE
WHITE JUMPER
START SWITCH DPST
GRAY
TOP OF SWITCH
BLACK BLACK
MOTOR WHITE RUN
START GRAY
L1
L2
H1
H2
PRESSURE SWITCH
SV AA149300i
© Midmark Corporation 2005
4
Next
Back Step 8: Verify shut-off valve is closed.
Gauges AA149600i
On/Off Switch
Shut -off Valve in Closed Position
Step 9: Turn power on. Note: Compressor should run quietly and storage tank will begin to pressurize.
Note: Compressor will shut-off automatically when gauge registers 100 PSI. You will hear a sound of air rushing from the pressure switch.
Step 10: Use soapy water to check for pressure leaks.
© Midmark Corporation 2005
5
Back
Next Note: Monitor line pressure when testing for leaks.
Step 11: Open the shut-off valve slowly and allow air to flow into the office air system.
Step 12: Allow office line to pressurize for 20-30 seconds. Check storage pressure gauge reading.
Gauges Shut-off Valve in Open Position
AA149700i
Step 13: Check gauge reading after 10 minutes. Note: If the storage pressure gauge registers a lower reading, an air leak exists. Locate the leak(s) and repair.
Equipment Alert Verify all leaks are sealed. Air leaks are the main cause of compressor failures!
Caution Always disconnect the power before servicing. The head(s) surface(s) can be very hot depending on pump usage. Do not touch these parts during or directly after operation.
© Midmark Corporation 2005
6
© Midmark Corporation 2005
7
2
2
7
10
O62
O82
1
3
O21
Heads
Max. Users
Vacuum Model
38
38
24
Width (IN.)
33
33
29
Height (IN.)
497
410
208
Weight (LBS.)
30
30
10
Tank Capacity
4
3
1.5
Total HP
208 - 230
208 - 230
115
Voltage
20
20
20
Amps Per Pump
30
30
30
Breaker Size per Pump (Amps)
16.9
12.4
5.2
CFM @ 80 PSI
5’ Flex Hose with 1/2” Or 3/8” MPT Termination (Provided)
Air Line (Provided by Plumber)
Disconnect Box OR Wall Mounted 24 V Compressor with listed Starter Contacor (PN ACACSC) Breaker/Fuse as per Specification
PVC Air Intake Vent (Provided By Plumber)
www.Midmark.com • 1-800-Midmark • www.Documark.com
31
31
21
Depth (IN.)
Level Compressor with Isolation Feet (Provided)
Condenstae Drain Canister (Provided with 5’ of 3/8” Polyflo Tubing)
Oil-Less Compressors
Specification Sheet
82
81
78
Sound Level (DB-A)
AA146000i
Back
Next
Back
Next
Note: Perform regular scheduled maintenance as required in the “Oil-Less Maintenance Guide”.
Customer Service/Technical Support Department hours are from 8:00 AM through 5:00 PM EST. Midmark Customer Service/Technical Support is available for order entry and technical support by phone 1-800-MIDMARK or (937) 526-3662 or FAX (877) 725-6495, Monday through Friday. We are closed on major holidays. Additional product documentation and specifications are available at your request or at our website at http://www.midmark.com.
Warranty All Apollo products are thoroughly inspected and tested in accordance with rigid specifications and standards. Our products are guaranteed against any defective material and workmanship from the date of shipment; provided, that the installation, operation, and maintenance is done in accordance with Apollo procedures as outlined in our Installation and Maintenance Guides. No other warranties or guarantees, expressed or implied are made. Midmark’s obligation under the warranty is to provide parts to the dealer for repairs or, at its option, to provide the replacement product (excluding labor and shipping charges). All special, incidental and/or consequential damages are excluded. We will not issue credit for product without first attempting to correct the problem in the field. Written notice of breach of warranty must be given to Midmark within the warranty period. The warranty does not cover damage resulting from improper installation or maintenance, accident or misuse. The warranty does not cover damage resulting from the use of cleaning, disinfecting or sterilizing chemicals and processes. The warranty does not cover vacuum failures due to hard water deposits. Failure to follow instructions provided in Midmark’s Installation and Maintenance Guides will void the warranty. * All warranty repairs must be repaired by authorized dealers and/or service dealers only - no exceptions. * Labor charges are NOT included. * Warranty period starts from the installation date. * Shipping damage or damage caused by equipment handlers and installers is not covered. Warranty Periods from Date of Install RevolutionTM Scroll Oil-Less Air Compressor 3 Years UltraVac ® Vacuum 3 Years Classic BronzeTM Vacuum 2 Years Gold Series ® Vacuum 2 Years Dry Vacuum (DryVacTM) 2 Years The Rock Oil-less Air Compressors 2 Years Oil-less Air Compressors 2 Years Lubricated Air Compressors 2 Years Replacement Parts and Accessories 90 Days** ** Replacement parts and repairs are covered under the remaining warranty of the unit they are replacing, or 90 days from the date of shipment, which ever is the longest.
Midmark Corporation 60 Vista Drive P.O. Box 286 Versailles, OH 45380-0286 937-526-3662 Fax 937-526-5542 www.midmark.com © Midmark Corporation 2005
8