OBX1000 High Capacity ODF Prysmian Part Number: See Following Pages
The OAsys OBX1000 High Capacity ODF is a 900mm x 300mm ETSI standard rack for optical distribution. The racks are available in 42U (2000mm) or 47U (2200mm) sizes and are able to accommodate up to 74 or 82 OAsys Splice and/or Patch Modules. The rack comprises of a frame, side and rear panels, doors and a central patchcord management system. Modules can be purchased pre-installed into the rack by Prysmian, or separately to suit the required application on day one or at a later date for expansion. A range of accessories are available for cable clamping and fibre/patchcord routing.
Features and Benefits
Kit Contents
• Available in heights of 42U (for up to 74 modules) or 47U (for up to 82 modules).
• Adjustable feet
• Accommodates OAsys Splicing and/or Patching modules for management of fibres.
• 2 side panels
• Splicing Modules enable splicing of up to 3552 fibres in 42U or 3936 fibres in 47U.
• Roof with cable inlets and patchcord outlets.
• Splicing + Patching Modules or Patch Only Modules enable up to 888 fibres to be accommodated in 42U or 984 fibres to be accommodated in 47U. • Modular system. Modules fitted on a when required basis
• Doors • 1 rear panel
Additional Items
• Splicing and bare fibre excess storage is performed inside a tray protected by a cover.
• Splicing and/or Patching Modules
• Modules pivot outwards for easy access.
• Cable Routing Accessories
• Cable Clamps
• Central storage section provides provision for storage of excess patchcord length. • A wide range of accessories are available for cable clamping, fibre routing and patchcord routing. • Brushed exit point in roof for patchcord routing
OAsys
Page 1 of 6
www.prysmian.com
Racks Technical Data • Rack Capacity:
74 modules (42U), 82 modules (47U)
• Maximum fibre capacity:
888f (42U Patching) 984f (47U Patching) 3552f (42U Splicing only) 3936f (47U Splicing only)
• Required space envelope (mm):
(h) 2000 (42U) x (w) 900 x (d) 300 (h) 2200 (47U) x (w) 900 x (d) 300
• Operating temperature:
-20 C to + 50 C (5 to 95% RH)
o
o
• Material:• Rack:
Mild Steel
• Modules
Mild Steel
• Splice Trays
FR Polymer
• Finish:• Rack
Painted Light Grey (RAL 7035)
• Module
Painted Light Grey (RAL 7035)
• Splice Tray
Light Grey
• Testing:• Optical:
Tested at 1310nm, 1550nm and 1625nm
• Dry heat:
BS EN 60068-2-2 Test Bb
• Damp heat:
IEC 60068-2-3: 1969
• Change of temperature:
IEC 60068-2-14: 1984
• Vibration:
IEC 60068-2-6: 1995
• Shock:
IEC 60068-2-27: 1987
Logistics
Pigtail Technical Data
Rack
Pigtails are supplied with either xx/UPC or xx/APC connectors.
• Packing Dimensions (mm): (h) 2200 x (w) 900 x (d) 300 • Packed Weight (kg):
250
• Net weight (kg):
155
Module • Packing Dimensions (mm): (h) 44 x (w) 310 x (d) 250 • Packed Weight (kg):
1.3
• Net weight (kg):
1.1
xx/UPC connectors can be used in cases where xx/PC or xx/SPC connectors are required. UPC
APC
• Insertion Loss (max)
0.3 dB
0.3 dB
• Return Loss (min)
50 dB
60 dB
Prysmian Telecom Cables & Systems UK Ltd, Chickenhall Lane, Bishopstoke, Hants SO50 6YU, UK Technical Enquiries +44 (0) 2380 608760 Fax Number +44 (0) 2380 608769 PRYSMIAN 2005. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.
OAsys
Page 2 of 6
Issue 01, October 2005 Ref: RA001
www.prysmian.com
Racks
OBX1000 Racks OBX1000 Standard Racks The OAsys OBX1000 is a high capacity ODF for up to 984 fibres. The rack is able to accommodate up to 74 (42U) or 82 (47U) OAsys Splice and/or Patch Modules. The rack is supplied with doors, side panels, a rear panel, adjustable feet and a central fibre management system for the routing of patchcords. Modules can then be fitted to the left or the right hand side of the central management system as required.
Prysmian Part Numbers:XEXSC00328 – 42U for up to 74 Modules XEXSC00329 – 47U for up to 82 Modules
OBX1000 Racks with Multi Cable Fixing System Pre-fitted The OBX1000 High Capacity ODF can be supplied with a Multi Cable Fixing system pre-fitted into the top or base of the rack to allow the fixing of up to 40 cables. The system is 7U in height and takes the place of 7 storage pockets. A rack must be ordered with the unit fitted in the factory, as it cannot be fitted at a later date.
Prysmian Part Numbers:XEXSC00351 – 42U for up to 60 modules & cable system fitted in Bottom XEXSC00352 – 47U for up to 68 modules & cable system fitted in Bottom XEXSC00353 – 42U for up to 60 modules & cable system fitted in Top XEXSC00354 – 47U for up to 68 modules & cable system fitted in Top
Modules Splicing Module The OAsys Splicing Module is supplied with 4 splice trays, each able to accommodate up to 12 spliced fibres.
Prysmian Part Numbers:XEXSC00203 – Left Hand Supplied separately XEXSF00183 – Left Hand Supplied pre-fitted into the Rack XEXSC00284 – Right Hand Supplied separately XEXSF00265 – Right Hand Supplied pre-fitted into the Rack
OAsys
Page 3 of 6
www.prysmian.com
Racks
Modules cont. Splicing and Patching Module The OAsys Splicing & Patching Modules are supplied with 12 pre-fitted Uniters and Pigtails. A variety of different connector types are available.
Prysmian Part Numbers:Left Hand Modules Finish Connector Type FC SC ST E2000 LC
Supplied Separately UPC XEXSC00188 XEXSC00190 XEXSC00192 XEXSC00193 XEXSC00448
Supplied Mounted in Chassis
APC XEXSC00189 XEXSC00191 N/A XEXSC00194 XEXSC00464
UPC XEXSF00169 XEXSF00171 XEXSF00173 XEXSF00174 XEXSF00399
APC XEXSF00170 XEXSF00172 N/A XEXSF00175 XEXSF00465
Right Hand Modules Finish Connector Type FC SC ST E2000 LC
Supplied Separately UPC XEXSC00270 XEXSC00272 XEXSC00274 XEXSC00275 XEXSC00474
Supplied Mounted in Chassis
APC XEXSC00271 XEXSC00273 N/A XEXSC00276 XEXSC00475
UPC XEXSF00251 XEXSF00253 XEXSF00255 XEXSF00256 XEXSF00476
APC XEXSF00252 XEXSF00254 N/A XEXSF00257 XEXSF00477
Patching Module OAsys Patching Modules are supplied with 12 pre-fitted Uniters. A variety of different Uniter types are available.
Prysmian Part Numbers:Left Hand Modules Finish Connector Type FC SC ST E2000 LC
Supplied Separately UPC XEXSC00195 XEXSC00197 XEXSC00199 XEXSC00201 XEXSC00466
Supplied Mounted in Chassis
APC XEXSC00196 XEXSC00198 N/A XEXSC00202 XEXSC00467
UPC XEXSF00176 XEXSF00178 XEXSF00180 XEXSF00181 XEXSF00468
APC XEXSF00177 XEXSF00179 N/A XEXSF00182 XEXSF00469
Right Hand Modules Finish Connector Type FC SC ST E2000 LC
Supplied Separately UPC XEXSC00277 XEXSC00279 XEXSC00281 XEXSC00282 XEXSC00470
APC XEXSC00278 XEXSC00280 N/A XEXSC00283 XEXSC00471
Supplied Mounted in Chassis UPC XEXSF00258 XEXSF00260 XEXSF00262 XEXSF00263 XEXSF00472
APC XEXSF00259 XEXSF00261 N/A XEXSF00264 XEXSF00473
Prysmian Telecom Cables & Systems UK Ltd, Chickenhall Lane, Bishopstoke, Hants SO50 6YU, UK Technical Enquiries +44 (0) 2380 608760 Fax Number +44 (0) 2380 608769 PRYSMIAN 2005. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.
OAsys
Page 4 of 6
Issue 01, October 2005 Ref: RA001
www.prysmian.com
Racks
Cable Clamping and Routing OBX1000 ARS Cable Clamp The OAsys OBX1000 ARS Cable Clamp is used to anchor the cable to the rack and route the fibres onto the Modules. The ARS is suitable for cables between 12 and 36 fibres. 10 metres of routing tube is supplied with the ARS.
Prysmian Part No. – XEXSC000345
OBX1000 BEM Cable Clamp The OAsys OBX 1000 BEM Cable Clamp is used to anchor the cable to the rack and route the fibres onto the Modules. The BEM is suitable for cables between 36 and 192 fibres. 20 metres of routing tube is supplied with the BEM.
Prysmian Part No. – XEXSC000346
OBX1000 Double BEM Cable Clamp The OAsys OBX 1000 Double BEM Cable Clamp is used to anchor a cable with a fibre count of 193 to 384 fibres to the rack and route the fibres onto the Modules. 40 metres of routing tube is supplied with the Double BEM.
Prysmian Part No. – XEXSC000347
Spare Transportation Tube – 10 metre coil Spare Transportation Tube for use with the ARS or BEM.
Prysmian Part No. – XEXSC000233
2U Routing Channel The 2U Routing Channel is used for routing patchcords horizontally within the rack to other ODF equipment. It is used in place of 2 modules.
Prysmian Part Numbers:XEXSC00348 – Left Hand 2U Routing Channel XEXSC00349 – Right Hand 2U Routing Channel
OAsys
Page 5 of 6
www.prysmian.com
Racks
Splice Protectors Heatshrink Splice Protectors OAsys splice protectors are used to protect the fibre splice. They are 2.2mm in diameter and 45mm in length.
Prysmian Part No. - XPESC00053 (pack of 50) - XKTSC00050 (pack of 12)
Crimp Splice Protector Kit The OAsys Crimp Splice Protector Kit is used to convert the splice tray in an OAsys In Line Joint to accommodate crimp splice protectors. One kit is required for each splice tray. The kit contains an insert to house the splice protectors and 12 crimp splice protectors.
Prysmian Part No. – XKTSC00020
Prysmian Telecom Cables & Systems UK Ltd, Chickenhall Lane, Bishopstoke, Hants SO50 6YU, UK Technical Enquiries +44 (0) 2380 608760 Fax Number +44 (0) 2380 608769 PRYSMIAN 2005. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.