Transcript
Océ Maintenance Card
Océ TDS450
o
Display
‘Previous’ key
previous
Navigation keys
‘Next/Select’ key next/select
‘Stop’ key
‘On-line’ key on-line
stop
Load roll 1
1 2
2
1 1
3
1
2
1. Open the drawer. Remove the roll holder.
2. Press the green knob to replace the media roll. Load the media roll.
3. Feed the media up to the rollers. Turn the rollers to feed the media up to the green arrow. Close the drawer.
Load roll 2
3 1
2
2
1
1. Open the flap. Remove the roll holder.
2. Press the green knob to replace the media roll. Load the media roll.
3. Feed the media up to the rollers. Turn the rollers to feed the media up to the green arrow. Close the drawer.
Add toner 2
1
1
2
1. Open the left cover. Before you open the toner bottle, shake the bottle.
2. Fasten the bottle. Turn the bottle into the upright position. When empty, return the bottle into the original position. Remove the bottle.
3. Replace the waste toner bag. Close the left cover.
2. Do not damage the sensor.
3. Clean the scan area with a lint-free cloth and Océ cleaner A. Dry the scan area with another lint-free cloth.
Clean scan area
1. Open the top cover.
GB
www.oce.com