Overview of the T Series V001R005 Unified storage
Block-level storage S2200 T
File engine
S6800T
Page 3
Introduction to the T Series V001R005 Unified Storage Products S2600T
Model
S5600T
S5500T
S5800T
Data Block Storage Components Processor Cache size
Multi-core processors 8 GB/16 GB
8 GB/16 GB/32 GB
24 GB/48 GB
96GB/192GB
Front-end host port
8 Gbit/s Fibre Channel, 1 Gbit/s Base-T iSCSI, 10 GE iSCSI (TOE)
8 Gbit/s Fibre Channel, 1 Gbit/s Base-T iSCSI, 10 GE iSCSI (TOE), 10 Gbit/s FCoE
8 Gbit/s Fibre Channel, 1 Gbit/s Base-T iSCSI, 10 GE iSCSI (TOE), 10 Gbit/s FCoE
8 Gbit/s Fibre Channel, 1 Gbit/s Base-T iSCSI, 10 GE iSCSI (TOE), 10 Gbit/s FCoE
Back-end expansion port
6 Gbit/s SAS 2.0 wide
6 Gbit/s SAS 2.0 wide
4 Gbit/s Fibre Channel or 6 Gbit/s SAS 2.0 wide
4 Gbit/s Fibre Channel or 6 Gbit/s SAS 2.0 wide
Front-end: 8 x 8 Gbit/s Fibre Channel; Back-end: 4 x SAS 2.0 wide
0
0
10 1152 Fibre Channel, SAS, NL-SAS, SATA, SSD
12 1440
Max. number of I/O modules Max. number of disk slots
Front-end: 12 x 1 Gbit/s iSCSI; Back-end: 4 x SAS 2.0 wide 2 276
Supported disk type
SAS, NL-SAS, SATA, SSD
Supported RAID level
RAID 0, 1, 3, 5, 6, 10, 50
Value-added functional software
HyperImage (virtual snapshot), HyperCopy (LUN copy), HyperClone (split mirror), HyperMirror (synchronous/asynchronous remote replication), HyperThin (thin provisioning), Application Protection Manager (application-level data protection), UltraPath (multipathing), DiskGuard (host-side data protection), SmartCache (dynamic data caching for the TurboBoost)
Number of onboard I/O ports
2 528 SAS, NL-SAS, SATA, SSD
Fibre Channel, SAS, NL-SAS, SATA, SSD
File Storage Components Supported number of file engine nodes Processor Cache size per node Max. number of I/O modules per node File system software Supported network protocol Max. size of a single file system Supported operating system
2, 4, 6, 8
2
2 and 4
2, 4, 6
Multi-core processors 16 GB
16 GB
24 GB
24 GB
6
6
6
6
Dynamic storage tiering, virtual snapshot, mirroring, remote replication, Symantec NetBackup Client Fibre Channel, SAS, iSCSI, NFS, CIFS, FTP, HTTP 256 TB with dynamic expansion supported AIX, HP-UX, Solaris, Linux, Windows
Virtualization Features Support for VMware VAAI Support for the integration with vSphere and vCenter
Supports VMware VAAI interfaces, significantly improving storage performance and efficiency under virtual environments. Integrates vRecovery for vSphere and vSphere vCenter, implementing virtual-machine-granularity backup, replication, and disaster-tolerance switch, and supporting disaster recovery drills.
Page 4
Introduction to File Engines • Being based on the Pangea V001R001 hardware platform (namely the controller enclosure of an S5500T/S5600T/S6800T), the file engine of a T series unified storage system is also 4 U high. • Each controller in this independent engine serves as a file engine node, and each engine serves as a two-node file engine.
Controller-file engine • Each controller serves as a node.
Interface module • Each node has six I/O module slots. • Each node has a GE card for heartbeat signaling. • Each node has an 8 Gbit/s Fibre Channel card for disk array connection. • Each node has a maximum of four GE or 10GE cards for interfacing with NAS hosts.
Page 5
Internal Heartbeat Network of a File Engine
Heartbeat network of a two-node file engine
Note: the GE I/O Module comes with File engine can only be used for heartbeat. The host connectivity requires extra I/O Module
Heartbeat network of a multi-node file engine (It requires additional switches, and each node uses two GE ports as heartbeat network ports.)
Page 6
Introduction to S5500T Storage Controllers (Part 1) 2.5-inch controller enclosure • Supports 24x2.5-inch disks. • Supports mainstream SAS and NL-SAS disks as well as SSDs. • Houses four 2+2 redundant coffer disks in the first four slots. • Supports the independent power-on or power-off of each disk.
3.5-inch controller enclosure • Supports 12x3.5-inch disks. • Supports mainstream SAS and NL-SAS disks as well as SSDs. • Houses four 2+2 redundant coffer disks in the first four slots. • Supports the independent power-on or power-off of each disk.
Power module • Adopts 1+1 redundancy. • Offers a power conversion efficiency up to 92%, which is higher than the 88% of conversion efficiency for golden power supplies.
Control unit in the disk and controller integration configuration • Provides management network ports and serial ports. • Carries two onboard 4x6 Gbit/s SAS ports. • Supports one expansion I/O module. • Carries four onboard 8 Gbit/s Fibre Channel ports.
Fan/BBU module • Adopts 3+1 redundancy for fan modules, ensuring system continuity when a single fan module becomes faulty. • Supports delicate and intelligent fan speed control. • Embeds BBUs against the data loss caused by expected power failures.
Page 7
Introduction to S5600T/S5800T Storage Controllers (Part 1) Control module • Uses two controllers. • Supports intelligent CPU frequency control for energy saving. • Provides a system poweroff button.
Interface module • Offers 12 I/O module slots. • Supports a maximum of 1440 disks. • Supports the hot swap for I/O modules. • Supports various ports including 8 Gbit/s Fibre Channel, 4 Gbit/s Fibre Channel, 4x6 Gbit/s SAS, and GE/10GE ports.
BBU module • Adopts 2+2 redundancy. • Supports the power failure protection for DC/AC power supplies.
Fan module • Adopts 5+1 redundancy for fan modules, ensuring system continuity when a single fan module becomes faulty. • Supports delicate and intelligent fan speed control.
Management module • Adopts 1+1 redundancy. • Supports hot swap.
Power module • Uses dual power planes with 2+2 redundancy. • Offers a power conversion efficiency of 92%, which is higher than the 88% of conversion efficiency for golden power supplies.
Page 8
Connecting a File Engine to a Storage System Through Fibre Channel Ports Engine node 7
Engine node 8
Engine node 5
Engine node 6
Engine node 3
Engine node 4
Engine node 1
Engine node 2 引擎节点2
Controller A
Controller B
Each file engine node connects controllers A and B through two Fibre Channel ports.
Storage unit
Page 9
Introduction to the T Series Storage Disk Enclosures Disk enclosure 2 U, 24 slots for 2.5-inch SAS disks
4 U, 24 slots for 3.5-inch SAS disks
• For theS2600T S5500T: 24-slot, 2.5-inch, 2 U SAS disk enclosure 24-slot, 3.5-inch, 4 U SAS disk enclosure (Does not support 4 U Fibre Channel disk enclosures.)
• For the S5600T/S5800T/S6800T: 24-slot, 2.5-inch, 2 U SAS disk enclosure 24-slot, 3.5-inch, 4 U SAS disk enclosure 24-slot, 3.5-inch, Fibre Channel disk enclosure
4 U, 24 slots for 3.5-inch Fibre Channel disks
Page 10
Value-added Software Functions ISM Functions
Required storage system management software Integrated Storage Manager-Device Management License for OceanStor Unified XXX (for unified storage systems) Integrated Storage Manager-Device Management License for OceanStor Block XXX to Unified XXX Upgrade (for upgrading disk arrays to unified storage systems) Integrated Storage Manager-Device Management License for OceanStor Block XXX (for disk arrays)
ISM — centralized graphical management software
File Engine Software Functions
File Engine CIFS (autoconfigured for common Internet file systems) File Engine NFS (autoconfigured for network file systems) File Engine FTP File Engine Replication File Engine Dynamic Storage Tiering
Disk Array Software Functions
HyperImage (virtual snapshot) HyperCopy (LUN copy) HyperMirror (synchronous/asynchronous remote replication) HyperThin (thin provisioning) SmartCache (dynamic data caching controlled by ondemand configured license)
UltraPath Functions
Required multipathing software (autoconfigured and support for all the mainstream operating systems)
DiskGuard Functions
Host-side data protection software controlled by on-demand configured license
• Easily monitors the operating status of various system components such as power modules, fan modules, disks, and host ports on a single interface. • Presents useful installation wizards and five-minute initial configuration for simplified storage management.
Page 11
Contents
1 Product Overview 2 Configuration Instructions 3 Configuration Instances
Quotation Elements for the T Series V001R005 集群NAS引擎
File engine
Storage file engine
Controller 存储单元 enclosure
Controller enclosure
Disk enclosure
Storage unit 服
务
Value-added function
Disk unit
Value-added storage functional component
其组件
Page 13
Unified Storage Product Configuration Procedure Start the UniSTAR tool.
(optional)
Select a model of storage product.
Select a model from the S2600T, S5500T, S5600T, and S5800T.
Determine the number of file engine nodes.
Select a file engine.
Select file engine I/O modules.
Select a controller enclosure. Typical config.
Determine storage system specs.
Basic config.
S2600T/S5500T
Determine the cache size.
Select a type of power supplies.
Determine the cache size.
Select a type of power supplies.
Select front-end expansion I/O modules.
Select front-end expansion I/O modules.
Determine the type & number of disks.
Select back-end expansion I/O modules.
Select installation materials & auxiliary devices.
Determine the type & number of disks.
Select value-added functions.
Select installation materials & auxiliary devices.
Determine the type & number of disks. S5600T/S5800T
Select Fibre Channel modems.
Select value-added functions.
Select value-added functions.
Notes: Each file engine node natively has four GE ports and four Fibre Channel ports including two GE ports for heartbeat signaling and two Fibre Channel ports for connecting to disk arrays. A file engine with more than two nodes requires two 24-port Ethernet switches. For the S5600T/S5800T in the basic configuration, you must select a type (SAS or Fibre Channel) of back-end I/O modules for it.
Page 14
S6800T Storage Configuration Procedure (optional) Start the UniSTAR tool.
Select a controller enclosure.
Select disks & installation materials.
Select accompanying value-added software.
选择安装维 保服务
Select a type of controller enclosure.
Select front-end expansion I/O modules.
Select back-end expansion I/O modules.
Select a type of power supplies.
Select disks.
Select installation materials & auxiliary devices.
Select modems.
Select value-added functions.
Note: Configuring and quoting the S6800T excludes selecting file engines as it is a non-unified storage product. Page 15
Quotation Instructions on Product Software and Value-added Functions
Data Block
File
Software and Value-added Function
Quotation Description
Integrated Storage Manager-Device Management License for OceanStor Unified XXX
Unified storage software: autoselected (Block storage management software is unnecessary for unified storage.)
Integrated Storage Manager-Device Management License for OceanStor Block XXX to Unified XXX Upgrade
Unified storage software (for upgrading from disk arrays to unified storage systems): manually selected
File Engine CIFS File Engine NFS File Engine FTP File Engine Replication File Engine Dynamic Storage Tiering
File engine software: 1. Autoconfigured when either of the items in green is selected 2. Manually configured when any of the other three items is selected
Integrated Storage Manager-Device Management License for OceanStor Block XXX
Disk array configuration functions: autoselected
HyperImage (virtual snapshot) HyperCopy (LUN copy) HyperMirror/S (synchronous remote replication) HyperMirror/A (asynchronous remote replication) HyperThin (thin provisioning)
Optional value-added functions
SmartCache
At least four SSDs are recommended.
OceanStor UltraPath
Multipathing software: For the typical configuration: autoconfigured; For the basic configuration: autoconfigured
OceanStor DiskGuard (V100R002)
Optional host software Page 16
Installation Materials and Auxiliary Devices Installation Material Patchcord, DLC/PC-DLC/PC, multi-mode, 62.5/125, 2 mm, 3 m Patchcord, DLC/PC-DLC/PC, multi-mode, 2 mm,10 m
Quotation Description Autoconfigured according to the number of host optical ports; Support for additional cables for a higher configuration
Purchased cable, mini SAS, 28 AWG, Key246, 1 m Autoconfigured according to the number of disk enclosures; Support for additional cables for a Purchased cable, external mini SAS, 6.0 m, external mini SAS 26-pin plug, 24 AWG x 8P, external higher configuration mini SAS 26-pin plug Purchased cable, mini SAS, 28 AWG, Key246, 3 m
Auxiliary Device Modem, 56 Kbit/s, data/fax, external, one-to-two (DB25 to DB25/DB9) cable, AC-to-12 V AC adapter, English documentation Modem, wireless GPRS, 48 Kbit/s, wireless interface, external, 100 to 240 V AC-to-12 V DC adapter, 5.5 mm x 2.1 mm adapter connector, English documentation, RS232 standard serial port
Quotation Description Optional depending on whether or not remote maintenance is required
Optical transceiver: ▬ Autoconfigured according to the number of host optical ports Disk unit filler panel: ▬ Unquoted item ▬ Default configuration for vacant slots I/O module filler panel: ▬ Unquoted item ▬ Default configuration for vacant slots
Page 17
Configuration Notes 1. Choose an appropriate RAID level. ▬ Chooses a suitable RAID level from the supported RAID 0, 1, 5, 6, 10, and 50 based on the actual application scenario. ▬ As recommended, uses RAID 5 or 1 SAS or Fibre Channel disks ▬ You need to use RAID 6 for a RAID group that consists of NL-SAS disks or SATA disks. (The ISM uses RAID 6 by default) . 2. Configure a moderate number of disks for each RAID group. ▬ The optimal number of disks configured for one RAID 5 or RAID 6 group is 8 to 11. ▬ Configures a maximum of 16 disks for each RAID 10 group. ▬ Weighs the disk utilization ratio, disk failure rate, reconstruction duration, and disk performance when you choose a RAID level. 3. Deploy hot spare disks. ▬ Deploys hot spare disks whenever possible. ▬ Avoids using coffer disks as hot spare disks. ▬ As recommended, configures at least one hot spare disk for each enclosure and at least two for the sole controller enclosure. 4. Intermix different types of disks in practice. ▬ Avoids intermixing high-speed disks with low-speed ones within the same enclosure. ▬ Configures dedicated hot spare disks for different types of disks. 5. Calculates the available capacity of disks according to the RAID level (redacted). 6. Configures an ideal of no more than 72 and a maximum of less than 120 disks for each pair of back-end Page 18 ports.
Contents
1 Product Overview 2 Configuration Instructions
3 Configuration Instances
Page 19
Unified Storage Product Configuration Instance Customer requirements: • Uses the S5600T with a cache capacity no less than 48 GB and supports AC power supplies. • Requires FC SAN, NFS, and CIFS protocols for the unified storage device and • •
• • • • •
needs a two-node file engine. Requires four GE ports as file engine ports. Requires 6 TB of raw capacity sourced by 3.5-inch, 600 GB, 15,000 rpm, SAS disks for their database applications. Requires 200 TB of raw capacity sourced by 3.5-inch, 2 TB, 7200 rpm, NL-SAS disks for their file applications. Requires 8x8 Gbit/s Fibre Channel and 16xGE iSCSI ports as front-end ports. Supports virtual snapshot and cloning software. Supports thin provisioning. Supports dynamic storage tiering for file engines. Page 20
Unified Storage Product Configuration Instance (Continued) Step 1 Choose a storage product and configure the file engine, controller enclosure, and interface modules for it.
Select whether or not to use a file engine for unified storage. Select a number of file engine nodes. Select either the basic or typical configuration for the controller enclosure. Select a type of power supplies. Select a specification of controller enclosure. Note: Each NAS engine node has four native GE ports with two for heartbeat signaling. Configure a pair of GE I/O module for host NAS connectivity
Select a type and number of ports for the controller enclosure.
Select either SAS or Fibre Channel as the type of back-end expansion disk enclosures.
Page 21
Unified Storage Product Configuration Instance (Continued) Step 2 Select a type and number of disks and choose value-added software functions.
Select a type and number of disks.
Select required value-added functions (in the red circle) for data blocks.
Select required value-added functions (in the green circle) for file systems.
Page 22
S6800T Configuration Instance Customer requirements: • Uses the S6800T with a cache capacity no less than 192 GB and supports AC power supplies. • Requires 2 TB of SSD cache sourced by 3.5-inch, 200 GB of SSDs. • Requires 30 TB of raw capacity sourced by 3.5-inch, 600 GB, 15,000 rpm, SAS disks for their database applications. • Requires 200 TB of raw capacity sourced by 3.5-inch, 2 TB, 7200 rpm, NL-SAS disks for their file applications. • Requires 16x8 Gbit/s Fibre Channel and 16xGE iSCSI ports as front-end ports. • Supports SSD caching. • Supports virtual snapshot and cloning software. • Support asynchronous remote replication. • Supports thin provisioning. Page 23
S6800T Configuration Instance (Continued) Step 1 Choose a storage product and select controller enclosure, interface module, and power supply types. Select a specification of controller enclosure. Select a type of power supplies for the controller enclosure.
Select front-end I/O modules.
Select I/O modules for the required type of back-end disk enclosures. Note: SAS I/O modules are selected in this case as the customer needs SAS disks for their backend disk enclosures.
Select a type and number of disks.
Note: SSDs are selected in this case as the customer needs the SmartCache function.
Page 24
S6800T Configuration Instance (Continued) Select required value-added storage functions.
Page 25
HUAWEI ENTERPRISE ICT SOLUTIONS A BETTER WAY
Copyright©2012 Huawei Technologies Co., Ltd. All Rights Reserved.
The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice.