Preview only show first 10 pages with watermark. For full document please download

Olympus Ix81

   EMBED


Share

Transcript

Olympus IX81 - HCM High Content Microscope Installed 2008, reworked 2016. Inverse widefield microscope in Pinkel setup with phase contrast optics (10x, 20x, 40x) and long-distance objectives for cell culture dishes (up to 40x). Equipped with a 2 Megapixel CMOS camera and filter sets to image all conventional dyes. XY scanning stage for 5D-data acquisition. Fully scriptable for arbitrary workflows, including intelligent acquisition with feedback from real-time image analysis. Stage-based environmental control (T/CO2) on request. Last update: July 2017 Frame Olympus IX81, inverse, motorized, auxiliary magnification (1.6x, manual) Objectives Pos. Objective Working distance (mm) 1 UPlanFL N 4x/0.13 PhL 17 Sample bottom (mm) -- 2 UPlanFL N 10x/0.3 Ph 10 -- 3 UPlanFL N 20x/0.5 Ph 2.1 4 LUCPlanFL N 40x/0.6 Ph Corr 3.0-4.2 0.17a 0.0 – 2.0 5 UPlanFL N 40x/0.75 Ph 0.51 0.17 6 UPlanFL N 60x/1.25 Oil Ph Irisb 0.10 0.17 aCover glass #1.5 bIris to lower NA to 0.65 Illumination  Olympus MT20 Xenon arc burner (150 W) with attenuator and excitation filter wheel  Halogen Lamp (12 V, 100 W) Camera  Point Grey Chameleon3 CMOS USB3.0 monochrome camera, 2048 x 1536 pixel, 3.45 x 3.45 µm pixel size, global shutter, 12-bit A/D converter. Exposure times from 11 µs to 12 s, up to 55 fps. Binning in aggregation or decimation mode (increases brightness or frame rate, respectively). XY Stage  Märzhäuser SCAN IM (112 x 74 mm), accuracy +/- 3 µm, repeatability < 1 µm  Inserts for 75 x 25 and 76 x 76 mm slides, 35 mm dishes, multiwell plates Olympus IX81 - HCM High Content Microscope Software  Micro-Manager 2.0 beta running on Windows 7 (64-bit) Filters Pos. Excitation Filter Wheel Reflector Turret 1 DAPI (381-392) Quad DA/FI/Cy3/Cy5 (Em 420-480, 511-532, 590-624, 678-723) 2 CFP (422-432) Triple CFP/YFP/DsRed (Em 450-480, 527-547, 598-648) 3 FITC (475-495) Single DAPI (Ex 327-353, BS 409, Em 423-468) 4 YFP (498-510) Single EGFP (Ex 459-481, BS 495, Em 500-540) 5 Cy3 (548-573) Single Cy3 (Ex 533-558, BS 565, Em 570-640) 6 mCherry (563-588) Single mRuby (BS 580, Em 602-662) 7 Cy5 (643-656) 8 empty Environmental Control (on request)  Heating inserts for 35 mm dishes, chamber slides/chambered cover glass and 96-well plates  CellASIC™ ONIX Tri-Gas Mixer (manual) Olympus IX81 - HCM High Content Microscope Reflector Turret – Filter Cubes Color code: excitation, blue; dichroic, green; emission, red. Quad DA/FI/Cy3/Cy5 Triple CFP/YFP/mCherry Single DAPI Single EGFP Single Cy3 Single mRuby