Online Ups

   EMBED


Share

Transcript

O n line U P S Transformerless Type Taurus Pro 3P/3P Taurus Pro 10K/15K/20K/30K/40K/60K Taurus Pro 80K/100K/120K Taurus Pro 160K/200K O N L I N E 7” touch LCD (optional) U P S • Online double conversion technology with DSP control • Output power factor 0.9 • Advanced control with Adaptive Feed Forward Cancellation (AFC) technology for very low harmonic distortion • Very low input current distortion (THDi < 1%) • Input power factor 0.99 at 10% load • Output efficiency up to 95% • Space-saving compact design • Over 60% materials recyclable • Remaining backup time calculation • Front access makes maintenance and replacement easily • Highly flexibility in single phase/ three-phase set-ups • Parallel redundant operation with up to 4 units • Variety of communications and options available • Flexible battery type configuration by request (only available for Taurus Pro 400V models) Taurus Pro 3P/3P 400V Online UPS Selection Guide MODEL PHASE CAPACITY Taurus Pro 10K Taurus Pro 15K Taurus Pro 20K Taurus Pro 30K 10KVA/ 9KW 15KVA/ 13.5KW 20KVA/ 18KW 30KVA/ 27KW Taurus Pro Taurus Pro Taurus Pro 40K 60K 80K 3-phase in / 3-phase out 40KVA/ 36KW 60KVA/ 54KW 80KVA/ 72KW Taurus Pro 100K Taurus Pro 120K Taurus Pro 160K Taurus Pro 200K 100KVA/ 90KW 120KVA/ 108KW 160KVA/ 144KW 200KVA/ 180KW INPUT Nominal Voltage 3 x 400V (3Ph + N) Acceptable Voltage Range +15% or –20% Frequency 50 / 60 Hz ±5 % < 1.0% @ 100% load < 2.0% @ 50% load < 5.0% @ 10% load High overload: PFC Limit (discharging batteries) < 1.5% @ 100% load < 2.5% @ 50% load < 6.0% @ 10% load Total Harmonic Distortion (THDi) Current Limitation Power Factor < 1.5% @ 100% load < 2.0% @ 50% load < 6.0% @ 10% load 1.0 INVERTER Nominal Voltage 3 x 400V (3Ph + N) Precision Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%) Frequency 50/60 Hz synchronised ±4 % With mains absent ±0.05% Max. Synchronisation Speed 10 Hz/s Waveform Pure Sinewave Total Harmonic Distortion (THDv) < 0.5% (Linear Load) ; < 1.5% (Non-linear Load) Phase Displacement 120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load) Dynamic Recovery Time 10 ms. at 98 % of the static value Admissible Overload Phase Overload: 125% for 10 min., 150% for 60s ; Total Overload: 112.5% for 10 min., 135% for 60s Admissible Crest Factor 3.4 : 1 3.2 :1 Admissible Power Factor 2.8 : 1 3.2 :1 3.0 :1 0.7 inductive to 0.7 capacitive Imbalance Output Voltage @ 100%Unbalanced Load <1% Current Limit High overload, short-circuit: RMS Voltage Limit ; High Crest-Factor current: Peak Voltage Limit STATIC BYPASS Type Solid state Voltage 3x400V (3Ph + N) Frequency 50/60 Hz Activation Criterion Microprocessor control Transfer Time Zero Admissible Overload 400% for 10 sec. Transfer to Bypass Immediate, for overloads above 150% Retransfer Automatic after alarm clear MAINTENANCE BYPASS Type Without interruption Voltage 3 x 400V (3Ph + N) Frequency Overall Efficiency (Line mode) 50/60 Hz 90.0% 90.5% 91.0% 92.0% 92.5% 93.0% 94.0% 93.0% 93.3% 12V 4.5Ah 12V 4.5Ah 12V 7Ah 12V 9Ah 12V 12Ah - 5 3 5 3 3 - 92.8% 92.6% BATTERY Built-in Battery Type (2x31) Back-up Time (minutes) Max. Charging Current 23.5 A 47 A 70.5 A 188 A PHYSICAL Dimension, D x W x H(mm) 770 x 450 x 1100 805 x 590 x 1320 Net Weight (without batteries) (Kg) 78 86 94 110 122 Net Weight (w/built-in batteries) (Kg) 178 186 249 290 357 162 231 255 850 x 900 x 1900 550 - *NOTE: When temperature is above 30°C, the output power will be derated. The output power is derated to 90% at 31°C -35°C and 80% at 36°C -40°C. * Product specifications are subject to change without further notice Advancing Power 34 O n lin e U P S Transformerless Type Taurus Pro 3P/3P 208V Online UPS Selection Guide MODEL Taurus Pro 7.5K Taurus Pro 10K Taurus Pro 15K Taurus Pro 20K 7.5KVA/ 6.75KW 10KVA/ 9KW 15KVA/ 13.5KW 20KVA/ 18KW PHASE O N L I N E U P S CAPACITY Taurus Pro Taurus Pro 30K 40K 3-phase in / 3-phase out 30KVA/ 40KVA/ 27KW 36KW Taurus Pro 50K Taurus Pro 60K Taurus Pro 80K Taurus Pro 100K 50KVA/ 45KW 60KVA/ 54KW 80KVA/ 72KW 100KVA/ 90KW INPUT Nominal Voltage 3 x 208V (3Ph + N) Acceptable Voltage Range +15% or –20% Frequency Total Harmonic Distortion (THDi) 50 / 60 Hz ±5 % < 1.0% @ 100% load < 2.0% @ 50% load < 5.0% @ 10% load High overload: PFC Limit (discharging batteries) < 1.5% @ 100% load < 2.5% @ 50% load < 6.0% @ 10% load Current Limitation Power Factor < 1.5% @ 100% load < 2.0% @ 50% load < 6.0% @ 10% load 0.99 from 10% load INVERTER Nominal Voltage 3 x 208V (3Ph + N) Precision Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%) Frequency 50/60 Hz synchronised ±4 % With mains absent ±0.05% Max. Synchronisation Speed 1 Hz/s Waveform Pure Sinewave Total Harmonic Distortion (THDv) < 0.5% (Linear Load) ; < 1.5% (Non-linear Load) Phase Displacement 120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load) Dynamic Recovery Time 10 ms. at 98 % of the static value Admissible Overload 125%~135% for 5 min., 135%~150% for 60 s Admissible Crest Factor 3.4 : 1 3.2 :1 2.8 : 1 Admissible Power Factor 3.2 :1 3.0 : 1 0.7 inductive to 0.7 capacitive Imbalance Output Voltage@ 100%Unbalanced Load <1% Current Limit High overload, short-circuit: RMS Voltage Limit ; High Crest-Factor current: Peak Voltage Limit STATIC BYPASS Type Solid state Voltage 3 x 208V (3Ph + N) Frequency 50/60 Hz Activation Criterion Microprocessor control Transfer Time Zero Admissible Overload 400% for 10 sec. Transfer to Bypass Immediate, for overloads above 150% Retransfer Automatic after alarm clear MAINTENANCE BYPASS Type Without interruption Voltage 3 x 208V (3Ph + N) Frequency Overall Efficiency (Line mode) 50/60 Hz 89.5% 90.0% 91.0% 91.5% 92.0% 12V 4.5Ah 12V 7Ah 12V 9Ah 12V 12Ah 93.0% 92.5% 92.0% 93.0% 93.0% BATTERY Built-in Battery Type (2x19) Max. Charging Current 23.5 A 47 A 70.5 A 188 A PHYSICAL Dimension, D x W x H(mm) Net Weight (without batteries) (Kg) Net Weight (w/built-in batteries) (Kg) 770 x 450 x 1100 805 x 590 x 1320 805 x 900 x 1900 86 94 110 122 162 231 255 255 151 195 227 272 - - - - 550 *NOTE: When temperature is above 30°C, the output power will be derated. The output power is derated to 90% at 31°C -35°C and 80% at 36°C -40°C. * Product specifications are subject to change without further notice External Battery Cabinet For 400V UPS BATTERY-12Ah Dimensions, D x W x H (mm) Built-in Battery Type (2 x 31) Net Weight (Kg) DIY Cabinet BATTERY-18Ah 700 x 450 x 1100 12V 12Ah 250 12V 18Ah 410 BATTERY-26Ah 805 x 590 x 1320 12V 26Ah 710 BATTERY-40Ah 980 x 650 x 1320 12V 40Ah 1020 C16 C32-17Ah C32-26Ah C32-40Ah C65 CH64-100 Dimensions, D x W x H (mm) 780 x 470 x 1190 780 x 880 x 1190 780 x 880 x 1190 780 x 880 x 1190 1500 x 860 x 1370 1600 x 970 x 1480 Built-in Battery Type (2 x 31) 12V 12Ah 12V 17Ah 12V 26Ah 12V 40Ah 12V65Ah 12V100Ah 45 45 95 95 150 180 Net Weight (Kg) * Battery cabinet types of C16 to CH64-100 are DIY-made battery cabinets. For 208V UPS Dimensions, D x W x H (mm) Built-in Battery Type (2 x 19) Net Weight (Kg) * Product specifications are subject to change without further notice 35 www.voltronicpower.com BATTERY-26Ah 700 x 450 x 1100 12V 26Ah 380 BATTERY-40Ah 805 x 590 x 1320 12V 40Ah 610