Preview only show first 10 pages with watermark. For full document please download

Onlinecomponents.com

   EMBED


Share

Transcript

s. nt ne po om on lin ec co m Data Connectors 63 Content Page 65 66 66 68 70 72 73 75 76 EtherCon ® - CAT6 ......................................................... Technical Data EtherCon ® - CAT6 .................................. Ordering Information EtherCon ® - CAT6 ........................ USB and Firewire Adapter ............................................. Technical Data USB and Firewire Adapter ...................... Ordering Information USB and Firewire Adapter ............ 77 78 78 79 80 80 co m OpticalCon ® - Cable Connector Assembly ...................... OpticalCon ® - Chassis Connector ................................... OpticalCon ® - Coupler ................................................... Technical Data OpticalCon ® ........................................... Ordering Information OpticalCon ® ................................. EtherCon ® - Cable Carrier .............................................. EtherCon ® - Receptacles ................................................ Technical Data EtherCon ® ............................................. Ordering Information EtherCon ® ................................... s. Introduction on lin ec om po ne nt Neutrik’s data connector range copes with the increasing demand of digital connections in the professional audio and entertainment industry. Digitalization in the audio business for networking and computerized controls requires also reliable and rugged interconnection systems. Neutrik® early understood this trend and realized Pro Audio proof connector systems based on standard digital interconnection products like fiber optic, Ethernet, USB or Firewire. The Neutrik® data connector line fulfils the stringent requirements of the Pro Audio market and offers ruggedized and reliable optical and RJ45 cable and chassis connectors as well as USB and Firewire panel mount connectors. Example of EtherCon® RJ45 Data Connector. 64 look for the logo O p t i c a l C o n ® Design Criteria During the past few years signal digitalization found its way into the Pro Audio & Entertainment business, revolutionizing equipment and applications. Nowadays one fiber optic cable can transmit hundreds of channels, is light and easy to pass, and avoids grounding problems or noises. Rugged metal housing Cable Connector Assembly nt s. co m The weak spot has been again the connector. Fragile fiber optic network connectors like the ST, SC, LC etc. are optimized for a one time permanent connection but can not meet the rough requirements of the entertainment industry. Military extended beam lens coupling connectors are very expensive and have the disadvantage of an extensive attenuation increase. ne NKO2M-4S75 Ruggedized and dirt protected fiber optic connection system Waterproof acc. to IP65 L Cable connector comes pre-assembled with a choice of five mobile field cables L Range of cables include rugged hybrid (fiber + 4 copper wires), robust and lightweight mobile field cable with 2 multi- or singlemode fibers, a 4 pole Y-split and a SMPTE type cable L Accommodates standard optical LC-Duplex connectors L Cable connector features rugged all metal housing and heavy duty cable retention L Excellent dust and dirt protection due to automatic sealing shutter with silicone gasket L Reliable Push-Pull locking mechanism L Easy to clean, no tools required L Cable packed in case, on drum or air spool L Field repairable L L po Neutrik®, as Pro Audio & Video technology leader when it comes to connectors, kept up with the time and developed a suitable fiber optic connection system - the OpticalCon®. Cable drum om The system is based on a standardized optical LC-Duplex connection but eliminates its weakness and guarantees a safe and rugged connection. on lin ec Because of the compatibility with conventional LC connectors it offers the choice of using a cost effective LC connector as a permanent connection (e.g. patch cable) or our rugged OpticalCon® cable connector for mobile applications. The system enables a run of up to 4 copper wires for power supply or any data signal, a special SMPTE-version has been optimized for broadcast applications and offers an additional ground-shell contact. The chassis connector acts as “feed through” and guarantees a simple installation by simply connecting a conventional LC-Duplex connector (e.g. with a permanent installation cable) on the rear. NKO2M-4S75* The cable connector comes pre-assembled onto a choice of mobile field cables, currently 5 types and their variations (Multimode, Singlemode, APC) can be offered in any length. www.neutrik.com 65 O p t i c a l C o n Rear LC connection Sealed housing ® - F i b e r Coloured coding to identify fiber mode Coupler nt s. co m Chassis Connector NAO2S-4S75W ne NO2-4FDW Designed as feedthrough with automatic sealing shutter L Shutter with silcone gasket protects optical connection from dust and dirt L Waterproof acc. to IP65 ingress protection L Rubber sealing gasket (black, blue, green) L Accommodates standard LC connectors on the rear for simple installation L Connection on the front side either by rugged OpticalCon ® or standard LC connector L Colour coding to identify fiber mode - Multimode – black - Singlemode PC – blue - Singlemode APC – green OpticalCon® coupler (adapter) in „D“ size housing for cable extensions L Available in three versions - LC-Duplex multi and single mode (PC and APC) all with 4 copper wires L NO2-4FDW NAO2M-4S75W on lin ec om po L OLD NEW IP65 66 look for the logo O p C o n n e c t i o n S y s t e m Features and Benefits 1 1 Sealing gasket 2 4 additional female copper contacts 3 Mates and locks also with standard 2 LC-Duplex connectors 3 m 4 co 5 Wiring: 4 Big solder cups (AWG 18) om po ne nt s. 5 Mates with conventional LC-Duplex 15 on lin ec t i c 1 Coloured sealing gasket identifies fiber mode 15 1 11 6 6 Dirtprotection 14 1 12 1 13 7 All metal rugged housing 8 Sealing shutter (inside) 7 9 Push-Pull locking mechanism 9 16 10 10 Standard LC-Duplex connector, easy to clean 10 1 4 additional copper contacts 11 12 Heavy duty cable retention 8 13 All metal bushing 14 4 Cable protection boot 16 6 Sealing ring www.neutrik.com 67 O p t i c a l C o n Te c h n i c a l D a t a O p t i c a l C o n ® ® - F i b e r Connectors Optical Optical connector Fiber Insertion loss Cable Connector Chassis Connector LC-Duplex LC-Duplex Feedthrough z z z z z z z z z z z z Multimode, Singlemode PC, Singlemode APC < 0.5 dB / connection Mechanical < 45 N > 1`000 cycles Insertion / withdrawal force Lifetime Cable retention force 2M-4S75 2S/2M SMPTE 4 MY 500 500 350 300 N N N N - Dielectric strength Rated voltage < 7 m7 > 10 G7 > 1 G7 1500 V dc 50 V ac Material Zinc diecast (ZnAl4Cu1) - male: - female: on lin ec 1 ... z z z z z - z z ceramics - z flammability UL94 HB z z z z - z z z z om Environmental -25°C to +75°C Operating temperature Solderability complies with IEC 68-2-20 z z z z z1 (hard Nickel or Ruthenium plating) Polyamid PA 6, PBT 30% GR, PBT 50% GR Brass (CuZn39Pb3) Bronze (CuSn6) Gold (gal 0.2 µm Au over 2 µm Ni) POM (brass) ZnAI4Cu1 EPDM, rubber boot po Contact surface Strain relief Bushing Boot Slit sleeve z z z z z z z1 ne Shell Insert / Insulation Contacts 4 (5) s. - initial: - after damp heat test: 4 NKO2M-4S75* NKO2S(A)-SMPTE* co 6A 10 A (contact 1+4) nt Contact resistance Insulation resistance m Electrical Number of electrical contacts Rated current - Not compatible to SMPTE 304M standard. Suitable for indoor (studio) camera links considering specific conditions acc. to IEC 60664-1 like pollution degree 1, overvoltage category 1 and rated voltage. For detailed information ask for the White Paper "OpticalCon @ SMPTE Indoor Applications". Te c h n i c a l D a t a F i b e r C a b l e s 2M Attenuation: 2S 2SA 4MY 2M-4S75 3.5 dB/km 1.5 dB/km 2.5 dB/km 0.7 dB/km @ @ @ @ 850 nm 1300 nm 1310 nm 1550 nm 3 dB/km 1 dB/km @ @ @ @ 850 nm 1300 nm 1310 nm 1550 nm 500 MHz-km 500 MHz-km 500 MHz-km 500 MHz-km 500 MHz-km 500 MHz-km Refraction index: @ @ @ @ 850 nm 1300 nm 1310 nm 1550 nm 1.468 1.468 1.468 1.468 1.482 1.477 Bandwidth: 68 0.5 dB/km 0.5 dB/km look for the logo 1.458 1.458 0.5 dB/km 0.5 dB/km 1.458 1.458 2S-S1 2SA-S1 0.45 dB/km 0.5 dB/km 0.45 dB/km 0.5 dB/km 1.468 1.468 1.468 1.468 O p C o n n e c t i o n S y s t e m Te c h n i c a l D a t a M o b i l e F i b e r C a b l e s PUR Jacket PUR Jacket PUR Jacket 2x Fiber 2x Fiber 2x Fiber Strain relief (Aramid yarn) Strain relief (Aramid yarn) Strain relief (Aramid yarn) PUR Jacket 2x Fiber 2x Fiber 2M 2S 2SA 4MY 2 Multimode 50 µm 125 µm 2 Singlemode 9 µm 125 µm 2 Singlemode 9 µm 125 µm 4 Multimode 50 µm 125 µm -    po om PUR Jacket 2x AWG 24 2x Fiber 4x AWG 18 m   Shield 2 Multimode 50 µm 125 µm 2 Singlemode 9 µm 125 µm 2 Singlemode 9 µm 125 µm 4 x AWG 18 (0.75mm2) 2 x AWG 24 + AWG 16 2 x AWG 24 + AWG 16 GFK Aramid yarn 8.9 mm PUR LC-Duplex Multimode black, matte 10 cm 78 kg/km Copperbraid-Tinned Stainless Steel Crimp type 9.2 mm PVC LC-Duplex Singlemode PC black, matte 10 cm 118 kg/km Copperbraid-Tinned Stainless Steel Crimp type 9.2 mm PVC LC-Duplex Singlemode APC black, matte 10 cm 118 kg/km           on lin ec  Strength member 2SA-S1    2x AWG 16 (1+4) 2S-S1    2x Fiber 2M-4S75    PUR Jacket   Wiring   Number of Fibers Fiber type Core diameter Cladding diameter Copper wires Outer shield Strength member Cable retention Overal diameter Jacket Optical connector Type Colour Min. bending radius Weight (2+3) Strength member Strain relief (Aramid yarn) co s.  nt  ne  Te c h n i c a l D a t a M o b i l e H y b r i d C a b l e s           Wiring Aramid yarn 9.5 mm PUR 2 x LC-Duplex Multimode black, matte 10 cm 103 kg/km  - Aramid yarn 5 mm PUR LC-Duplex Singlemode APC black, matte 4 cm 23 kg/km  - Aramid yarn 5 mm PUR LC-Duplex Singlemode PC black, matte 4 cm 23 kg/km   - Aramid yarn 5 mm PUR LC-Duplex Multimode black, matte 4 cm 23 kg/km  Number of Fibers Fiber type Core diameter Cladding diameter Copper wires Outer shield Strength member Cable retention Overal diameter Jacket Optical connector Type Colour Min. bending radius Weight Strain relief (Aramid yarn)  t i c www.neutrik.com 69 O p t i c a l C o n ® - F i b e r Ordering Information Coding of Mobile Cables Find a convenient OpticalCon ® part number generator on www.neutrik.com N K O 2 M - 4 S 7 5 - R - 1 F - 1 5 0 (Example) Length [m] Gender: No suffix ... Male-Male; F ... Male-Female Packaging 0 to 4 Plating: No suffix ... hard Nickel; R ... Ruthenium Cable (Assembled) Neutrik Optical Cable ® Gender Male-Female Standard product (two cable ends) wired chassis connector for cable extention (one cable end) 4x AWG 18 PUR Jacket PUR Jacket 2x Fiber 2x Fiber Strength member Strain relief (Aramid yarn) 2M-4S75 2) - ...Gender: Male-male only (no suffix) on lin ec Packaging 0 ... Airspool 2) Strain relief (Aramid yarn) 1 ... OpticalCon Case 2 ... Drum Schill GT310 4 pole Y-split cable PUR Jacket 2x AWG 24 2x Fiber PUR Jacket 2x Fiber Strength member 2x Fiber Shield Strain relief (Aramid yarn) 2x AWG 16 2M 2S 2SA om 1) SMPTE cable po Multimode PC (black) Singlemode PC (blue) Singlemode APC (green) s. 2 pole field cable nt Field cable + copper ne Cable co m Male-Male 2S-S1 2) 2SA-S1 2) 4MY 1) 2) - 3 ... Drum Schill GT380 4 ... Drum Schill HT582 ...Packaging "2" not possible Chassis Connectors Colour Plating Fiber Solder contacts Shell ground contact * * * * hard Nickel Ruthenium hard Nickel Ruthenium 2x 2x 2x 2x 4x 4x 4x 4x 1x 1x Colour (fiber mode) Plating Fiber black blue green black black black LC-Duplex Multimode PC LC-Duplex Singlemode PC LC-Duplex Singlemode APC NO2-4FDW NO2-4FDW-R NO2-4FDW-1 NO2-4FDW-1-R * ... Coloured labeling to indicate the fiber mode included.    look for the logo  70 4 x 0.75 mm2 4 x 0.75 mm2 4 x 0.75 mm2  NAO2M-4S75W NAO2S-4S75W NAO2SA-4S75W Copper wire  Coupler O p C o n n e c t i o n S y s t e m Accessories NDO NDO SCDR SCDX Field repair toolkit OpticalCon SCDR SCDX Field repair toolkit Dummy plug for OpticalCon chassis connector Rear end protection cover for D-size chassis connectors Hinged cover seals D-size chassis connectors, IP42 rated find more details on www.neutrik.com ® Wiring and hook up suggestion nt s. co m In order to achieve uniform and compatible systems we recommend to follow the hook up suggestions of the ISO / IEC 11801 which defines channel A (right) as input and B (left) as output. ne A A B om Extract of the ISO / IEC 11801 Patch cord termination configuration po B It is recommended that connection of patch cords and equipment cords to the duplex adapter be made by means of a duplex connector assembly. on lin ec t i c Optical fibre patch cords, whether they are used for cross-connection or interconnection to equipment, shall be of a crossover orientation such that Position A goes to Position B on one optical fibre, and Position B goes to Position A on the other optical fibre of the optical fibre pair (Figure 17). Each end of the optical fibre patch cord shall be identified to indicate Position A and Position B if the connector can be separated into its simplex components. For alternate connector designs utilising latches, the latch defines the positioning in the same manner as the keys. For simplex connectors, the connector that plugs into the receiver shall be considered Position A, and the connector that plugs into the transmitter shall be considered Position B.     Legend: Figure 17 - Optical = Connector = Position "A" = Position "B" Note: Shading for clarification only www.neutrik.com 71 E t h e r C o n ® Ruggedized RJ45 Data Connector Rugged diecast shell Bushing Ethercon® provides solutions for data transfer in harsh and demanding applications. These connectors are especially applicable for Ethernet networking in audio, commercial, entertainment, live stage production, DMX lighting, industrial and outdoor internet access environments. m co s. nt ne NE8MC + BSE* on lin ec om Neutrik® Ethercon® receptacles comply with CAT5e (IDC versions) or Class D (PCB versions), shielded or unshielded according to TIA / EIA 586B and ISO / EC 11801 standard. EtherCon chassis overview PCB mount IDC Feedthrough 72 Class D CAT 5e CAT 6 Fastethernet 10/100 Base-T Gigabit 1000 Base-T 10 Gigabit (IP54) NE8FDH-C5E NE8FAV-Y* NE8FDV-Y* NE8FDP NE8FF NE8FDY-C6 NE8FAV NE8FBV NE8FDV NE8FAH NE8FBH* look for the logo NE8MC-1 + BSE* The RJ45 system for harsh and demanding environment Cable connector carrier accepts the most common RJ45 plugs L Cable carrier has rugged diecast shell and unique chuck type strain relief L NE8MC-1 version with weatherproof Collinox plating and O-ring gasket L Protects Ethernet connections in a variety of commercial type applications and is designed to prevent breakage of the fragile components of standard RJ45 connectors L Cable carrier does not include RJ45 plug L L po The Ethercon ® series offers male cable carriers, assembled female receptacles, feedthrough jacks, cable coupler and shielded versions with or without illumination possibilities by LEDs. The male cable end offers a rugged diecast metal shell as a carrier for pre-assembled RJ45 plugs, which does not require the re-termination of the cable assembly. Female chassis receptacles are based on the current Neutrik® “A & B” series as well the “D” series of XLR receptacles with secure latching system - a feature not found on other RJ45 receptacles. Terminations include horizontal and vertical PCB or IDC. Colour coding is available for both the cable carriers and the receptacles for ease of identification. Cable Carriers NE8MC NE8MC-1 E t h e r C o n Horizontal PCB Vertical PCB ® IDC Terminals NE8FBH NE8FAV-YK "A / B" and "D" sized receptacles available in vertical and horizontal PCB or IDC terminations L Accommodates NE8MC carriers or any standard RJ45 Plug L D-versions with unified metal flange equal to “D” seriesXLR, Speakon®, PowerCon® and BNC Bulkhead NE8FDV-Y110-B NE8FDH-C5E Receptacles comply with Class D (PCB versions) or CAT 5e (IDC versions and NE8FDH-C5E) according to TIA / EIA 568B and ISO / IEC 11801 standard L D-version mountable from the front or rear of the panel L Version with screw domes to fix connector onto PCB securely (NE8FAV-SD) L NE8FAV-SD NE8FBH on lin ec NE8FAV om po L NE8FDV ne NE8FAV + ACRF-2 nt s. co m Receptacles NE8FAV-YK NE8FAV-Y110 NE8FDV www.neutrik.com 73 E t h e r C o n Completely closed housing Light pipe ® NE8FDP rear side Feedthrough L L L po L om L NE8FDP Comprehensive shielding granted by completely closed metal housing Improves EMC performance of appliance even in unmated condition Lighted version offers in addition various illuminating indication possibilities by means of two separate light pipes Light pipes illuminated by standard 3 mm LEDs - to be mounted on PCB by customer NE8FBH-S on lin ec L NE8FBH-LED ne NE8FBH-S nt s. co m Shielded & Lighted Locking latch NE8FBH-LED 74 L Feedthrough as panel mount receptacle and as cable coupler NE8FDP feedthrough connector in D series housing for use in patchfields - rear side accommodates standard RJ45 plug NE8FF coupler (adapter) for cable to cable mating - use with NE8MC carriers or any standard RJ45 plugs NE8FDP NE8FF look for the logo NE8FF T e c h n i c a l Specification D a t a NE8MC* Cable Con. NE8FA/B* (A + B Series) NE8FD* (D Series) Electrical - 1) - 1) - 1) - 1) - 1) - 1) - 1) - 1) PCB Versions z Mechanical I nsertion / withdrawal force z z - 1) - ne Cable O.D. range Wire size Panel thickness Material on lin ec Contacts Contact surface Locking Element Bushing Boot Sealing gasket po B / D-flange Strain relief clamp PBT D202G30 Zinc diecast (ZnAICu1, gal Ni / bl Cr / Collinox) Zinc diecast (ZnAICu1, gal Ni / bl Cr) POM CuZn35Pb2, Tin plated Bronze (CuSn6) Au (gal 0.2 µm over Ni plating) Ck 67 steel, treated Polyamide (PA 6 15% GR) Polyamide (PA 6) EPDM om Housing z z z z z z z z z z z zNE8FDH-C5E PCB Versions NE8FDV z co  8 z z z s.  latch lock > 1`000 mating cycles > 200 mating cycles b20 N 3.5 - 8 mm AWG 26 - 20 max. 3 mm / 0.12" nt Retention method Life time (mating cycles) 8 z m Number of contacts > 1.5 A Rated current per contact Rated voltage < 50 V ac < 10 m7 Contact resistance > 500 M7 Insulation resistance > 1`000 V ac rms Dielectric strength 1 - 100 MHz Frequency bandwidth Transmission class acc. TIA / EIA 568B or IEC 11801 CAT 5e Class D - 1) z z - SE8FD z z NE8*-Y* z NE8*-Y* 4 mm / 0.16" z - z z - - - z z NE8*-Y* NE8*-Y* 1) z z 1) z z - z z z - - SE8FD z z z - - SE8FD SE8FD z - z Environment Operating Temperature  -30°C to +80°C -20°C to +60°C IP54 UL94 HB Protection class Flammability Solderability complies with IEC 68-2-20 Mating screw Colour coding 1) z z z BSE-* / BSX-* PCB Version A screw ACRF-* PCB Version E screw DSS-* ...Specs depend on type of RJ45 plugs used www.neutrik.com 75 O r d e r i n g I n f o r m a t i o n ® Ordering Information Cable Connector NE8MC Cable housing with chuck and bushing (two antikink boots, one up to 5 mm and one up to 8 mm cable O.D.) (standard bushing in black, 9 different coding colours on request) NE8MC-B Black chromium housing with chuck and bushing (two antikink boots, one for 5 mm and one for 8 mm cable O.D.) (standard bushing in black, 9 different coding colours on request) NE8MC-1 Cable housing with chuck and X-series bushing, Collinox plating and O-ring gasket (perfect for waterproof applications) (standard bushing in black, 9 different coding colours on request) Black chromium housing with chuck and X-series bushing (standard bushing in black, 9 different coding colours on request) NE8MC-B-1 IMPORTANT: Cable connectors do not include RJ 45 plug. RJ 45 cable assembly must be provided by end-user! A-shape (all plastic) B-shape (Nickel ring) D-shape Horizontal PCB Vertical PCB Vertical PCB with additional screw domes IDC terminals IDC 110 punch down terminals Horizontal PCB with metal housing (shielded) Horizontal PCB in CAT5e Horizontal PCB with metal housing and light pipe NE8FAH NE8FAV NE8FAV-SD** NE8FAV-YK ** NE8FAV-Y110 ** NE8FBH NE8FBV NE8FDV co NE8FDV-YK ** NE8FDV-Y110 ** s. NE8FBH-S NE8FDH-C5e nt NE8FBH-LED Feedthrough po Receptacle (includes 2 mounting screws) Coupler ne ** ... includes 2 mounting screws NE8FDP NE8FF m Receptacle A screw A-Screw E-Screw E-Screw-Ni ACRF-* BSE-* BSX-* DSS-* SCDX on lin ec om Accessories E screw E screw Nickel ACRF-* DSS-* BSE-* BSX-* Mounting screw for A / B -shape (black self-tapping PLASTITE ® screw 2.9 x 8, panhead) Mounting screw for D-shape (black self-tapping PLASTITE ® screw 2.9 x 12, countersunk) Mounting screw for D-shape (Nickel self-tapping PLASTITE ® screw 2.9 x 12, countersunk) Coloured coding rings for A-shape receptacles (Box of 100 pcs.) Coloured boot for cable connector carrier (Box of 100 pcs.) Coloured bushing for NE8MC-1 and NE8MC-B-1 cable connectors Lettering plate for D series, coloured plastic Hinged cover seals D-size chassis connectors, IP42 rated *: 0 - Black, 1- Brown, 2 - Red, 3 - Orange, 4 - Yellow, 5 - Green, 6 - Blue, 7 - Violet, 8 - Grey, 9 - White Wa t e r p r o o f k i t f o r E t h e r C o n ® D - S e r i e s Waterproof assembly kit - SE8FD SE8FD 76 Waterproof kit, IP 54, consists of push, gasket, frontplate Suitable for all NE8FD*, perfect in combination with NE8MC-1 (with Colinox plating and sealing gasket) look for the logo SCDX E t h e r C o n D-shape metal shell Closed shielding ® C A T 6 Push Pull locking C AT 6 P a t c h C a b l e NE8FDY-C6-B NKE6S-* ne NE8FDY-C6 nt s. co m C AT 6 R e c e p t a c l e s IP65 in mated condition CAT6 compliant - data rate up to 10 GBit/s IP 65 rated - with dust and waterproof resistant sealing L Push Pull mating design provides secure locking system L Shielded system - high noise immunity and EMI protection L IDC contacts offer gas-tight termination L Ready made patch cables with rugged diecast cable carrier and unique chuck-type strain relief L NE8FDY-C6 on lin ec om po L NKE6S-* l NKE6S-*-WOC w w w www.neutrik.com .neutrik.com 77 E t h e r C o n ® C A T 6 Design Criteria The ruggedized RJ45 CAT6 connection system, provides solutions for high bandwidth data transfer in harsh and demanding environments. This series offers additional headroom for high performance Fast Ethernet 100BaseT and Gigabit Ethernet 1000BaseT connectivity in audio, lighting, live stage and industrial environments and even guarantees to be prepared for future 10 Gbit applications (true CAT6). The EtherCon CAT6 series offers a D-shape panel connector with metal housing and secure latching system. Tool-free IDC termination makes cable assembly easy and fast. The preassembled CAT6 patch cables use a shielded S/FTP cable with cable plug carrier offering a robust metal shell and Push-Pull locking system. Integrated sealing rings make the system dust and waterproof to IP 65 rating. Features & Benefits: L L L L L L L CAT6 performance – fast data transmission and high bandwidth applications CAT6 specifications according TIA / EIA 568B, ISO / IEC 11801, EN 50173 Shielded system - high noise immunity and EMI protection Push Pull mating - secure and proven locking system D-shape metal panel connector Ground lead jumper on panel connector with selectable grounding option IDC termination without tool Ready made patch cables with rugged cable carrier and unique chuck-type strain relief Dust and waterproof according IP 65 m L co L s. Te c h n i c a l D a t a Receptacle Patch cable Materials Receptacle Patch cable Number of contacts: Rated current per contact: TIA / EIA rating: Input to output resistance: Insulation resistance: Dielectric strength: NEXT (250 MHz): Attenuation (250 MHz): 8 1.5 A CAT6 < 200 m7 > 500 M7 1 kV dc 48.7 dB 0.1 dB 8 1.5 A CAT6 < 200 m7 > 500 M7 1 kV dc 48.7 dB Housing: Adapter: Strain relief clamp: Contacts: Contact surface: Bushing: Zinc diecast Polyamide PA 6 Bronze CuSn Gold - Zinc diecast Polyamide PA 6 POM Bronze CuSn Gold PU /PA ne po Push-Pull > 1`000 0.5 - 0.65 mm (AWG 24 - AWG 22) AWG 26 / 7 - 22 / 7 on lin ec Retention method: Life time (mating cycles): Wire size: Stranded wire: om Mechanical nt Electrical Environmental Operating temperature: Storage temperature: Flammability: Protection class: Ordering Information Patch Cable NKE6S-* NKE6S-*-WOC Standard lengths: 0.5, 1, 3, 5, 10 m Equipped on one side with metal shell, standard lengths: 0.5, 1, 3, 5, 10 m Custom length in meter steps on request. Receptacle NE8FDY-C6 NE8FDY-C6-B 78 EtherCon CAT6 with Nickel D-shell EtherCon CAT6 with Black Chrome D-shell look for the logo -10°C to +60°C -40°C to +70°C UL94HB IP 65 U S B D-shape metal housing a n d F i r e w i r e USB type B A d a p t e r D-shape metal housing IEE 1394 receptacle Firewire nt s. co m USB L L po L om L Ideal for audio networking and integration of computerbased equipment into audio systems USB gender changer type A-B (B-A) Reversible insert offering type A or B on front or rear end Universally accepted standard D-shape housing NAUSB on lin ec L NA1394-6-B ne NAUSB L L Ideal for audio networking and integration of digital equipment into audio systems Firewire feedthrough with 6-pole IEEE 1394 receptacle at both ends Universally accepted standard D-shape housing NA1394-6 www.neutrik.com 79 U S B a n d F i r e w i r e A d a p t e r Te c h n i c a l D a t a USB Mechanical Insertion / withdrawal force Lifetime Firewire < 35 N / > 10 N > 1`500 cycles z z z z 1.5 A < 30 m7 (mated pair) z z Electrical Rated current Contact resistance Insulation resistance Dielectric withstanding voltage Rated voltage z > 1 G7 > 100 M7 z z < 30 V ac < 40 V dc m 500 V ac (1 min) z z z z z Material Nickel or black Chrome Polyamid PA 6 Brass (CuZn39Pb3) Gold Nickel Operating temperature Flammability -25°C to +85°C z z z z z z om USB A – USB B Adapter (reversible), Nickel housing USB A – USB B Adapter (reversible), black housing Firewire on lin ec 6-pole Firewire Adapter (IEEE 1394), Nickel housing 6-pole Firewire Adapter (IEEE 1394), black housing DSS-* SCM SCDX z po USB Accessories - z ne UL94 V-0 Ordering Information NA 1394-6 NA 1394-6-B nt Environmental NAUSB NAUSB-B z s. Zinc diecast (ZnAl4Cu1) co Shell Insert / Insulation Contacts Contact finish Shell finish SCM SCDX Lettering plate for D series, coloured plastic Plastic sealing cover to protect the Firewire connectors against dust and moisture. Hinged cover seals D-size chassis connectors, IP42 rated *: 0 - Black, 1- Brown, 2 - Red, 3 - Orange, 4 - Yellow, 5 - Green, 6 - Blue, 7 - Violet, 8 - Grey, 9 - White 80 look for the logo