Transcript
OPAL Air Purifier
Instruction Manual
omega altise
Important Safety Instructions 1. 2. 3. 4. 5. 6.
7. 8. 9. 10. 11. 12. 13.
Read all instructions. Disconnect the power plug before dismantling, assembling or before cleaning. Avoid touching mobile parts of the unit. Make sure the air purifier is on a dry and even surface. Never insert fingers, pencils or any other objects through the guards whenever the power plug is connected, especially while running. The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervised or instruction concerning use of the appliance by a responsible person for their safely. Young children or infirm persons should be supervised to ensure that they do not play with the appliance. Do not use the appliance for any other purpose than its intended use. The air purifier must not be used if the guards are not fastened according to instructions. When the power cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. Do not use your appliance with an extension cord unless it has been checked and tested by a qualified electrician or electrical supplier. Use indoors and in dry locations only. It is not intended to use outdoors or in wet environments. Except for filter replacement, the Air Purifier is not intended to be services and does not contain any serviceable replacement parts or adjustments.
Read all instructions before using this unit. Keep them for future reference. CAUTION! Do not immerse the unit in water or allow water to drip into the interior of the housing as this could create a fire or electric shock hazard. WARNING! Do not attempt to open or repair the unit yourself. Doing so could void the warranty and cause damage or personal injury.
2
omega altise
Specifications Model Rated Voltage Watts Dimensions (h x w x d) mm
OPAL
Weight
4.7kg
220-240V / 50Hz
Control
Electronic
85W
Purifying air per hour
370 x 425 x 173
Warranty
3
120 cubic f/min 2 year replacement
omega altise
Parts List
4
omega altise
Operating Instructions
Remove the air purifier form its packaging. Ensure that the system of supplied filters is properly in place. Plug the power cord correctly into an electrical outlet. Press the power button to turn the air purifier on. Press the same button again to turn the air purifier off. Press the fan button to select the fan speed: L (low) Æ M (medium) Æ H (high) Press the ion button to turn on the ionizer function. Press the button again to turn this function off. Press the clock button to select the timer-off function: 1 Æ 2 Æ 4 Æ 8 The air purifier will automatically turn off when it runs for the selected hours. The HEPA filter indicator will light up when the HEPA filter needs to be replaced (approx 2000 hrs depending on the quality of air). Hold the filter button for several second until the HEPA filter indicator shuts off. This will reset the 2000 hours of use timer.
Filter System This unit uses a HEPA and active carbon filter assembly to purify the air passing through it. •
Active carbon filter – removes odours, organic vapour and larger dust particles and hair.
•
HEPA – removes airborne particles (down to 0.3 micron size) and airborne allergens such as fine dust, dust mite debris or bacteria etc. Typically the filter should be changed after every 2000 hours of use. However, this may vary depending on the surrounding conditions of actual use.
5
omega altise
Care and Maintenance Filter Replacement When the HEPA filter indicator lights up, it means that the HEPA filter has been used for 2000 hours and needs to be replaced. The steps to replace the HEPA filter: 1. Turn off and unplug the unit. 2. Carefully lay down the unit on a flat surface with the front grill facing up. 3. Push in on the release buttons (as shown) on both sides of the unit and swing open the front grille. 4. Remove the old HEPA filter and replace with the new HEPA filter. 5. Reposition the front grille. 6. Reset the HEPA filter indicator timer by holding the button until the HEPA filter indicator light turns off. 7. Plug into a power socket. The unit is ready to continue operation.
6
omega altise Cleaning This Air Purifier requires regular cleaning and removal of dirt to maintain proper operation. To clean: 1. Always disconnect the cord from the electrical outlet. 2. Use a soft and clean cloth to wipe the outside of the machine. Never use excessive water, strong or corrosive detergent to clean the machine. Gently wipe the surface, particularly the front shell, air inlet and outlet vents. 3. If you wish to clean the inside of the Air Purifier, use only a clean, dry and soft cloth to wipe it down. Please do not attempt to clean the ionizer needle because it may be damaged and/or cause the ionizer to malfunction. 4. Store the air purifier in a clean dry place when not in use.
CAUTION! Do not immerse the unit in water or allow water to drip into the interior of the housing as this could create a fire or electric shock hazard. WARNING! Do not attempt to open or repair the unit yourself. Doing so could void the warranty and cause damage or personal injury.
Omega Altise products are distributed in Australia by MEA, (A Division of Hagemeyer Brands Australia Pty Ltd) ABN 28 001 375 686 Locked Bag 4013, Kingsgrove NSW 2208 Phone: 1300 739 033 Fax: 1800 838 899 Email:
[email protected] Web: meaappliances.com.au
7