Preview only show first 10 pages with watermark. For full document please download

Open Eir Nga Technical Handbook

   EMBED


Share

Transcript

         1 eircom NGN Node NTU SAB eircom Exchange DSLAM NTU eircom ODF VPLS NTU FTTC VUA VUA Unicast Logical Connection Access eircom NGN Node ONT WEIL SAB eircom Exchange ONT OLT eircom ODF VPLS ONT FTTH VUA Access VUA Unicast Logical Connection WEIL NTU DSLAM NTU eircom NGN Node eircom Exchange NTU eircom ODF VPLS ONT ONT OLT ONT FTTH/FTTC VUA Access VUA Multicast Logical Connection WEIL NTU DSLAM NTU eircom NGN Node eircom Exchange NTU eircom ODF ONT VPLS ONT OLT ONT VUA Unicast/Multicast Access VUA Unicast/Multicast Logical Connection WEIL NTU DSLAM eircom NGN Node eircom NGN NTU eircom NGN Node Operator Handover Site eircom NTU VPLS NTU SAB FTTC BP WEIL BP Unicast Logical Connection Access ONT eircom NGN Node ONT OLT eircom NGN eircom NGN Node Operator Handover Site eircom NTU VPLS ONT SAB FTTH BP Access BP Unicast Logical Connection WEIL NTU DSLAM NTU eircom NGN NTU Operator Handover Site A eircom NGN Node eircom NGN Node eircom NTU ONT VPLS ONT OLT eircom NGN Node eircom NTU ONT Operator Handover Site B FTTx BP Access BP Unicast Logical Connection WEIL NTU DSLAM NTU eircom NGN NTU eircom NGN Node eircom NGN Node PE PE Operator Handover Site ONT VPLS ONT PE OLT eircom NTU MVPN PE SAB ONT FTTx BP Access BP Multicast Logical Connection WEIL Master Socket DSLAM Master Socket eircom NGN Node Operator Handover Site A eircom NGN Node eircom NGN Master Socket eircom NTU PE PE ONT VPLS ONT OLT MVPN PE PE eircom NTU SAB eircom NGN Node ONT FTTx BP Access BP Multicast Logical Connection Operator Handover Site B WEIL   , , 1 2 1 4 1 3 1 5 1 7 1 CPE S-VLAN ONT End-User Traffic 802.1p marking (C-VLAN 10) OLT S-VLAN VPLS Access Connections eircom ODF C-VLAN CPE S-VLAN NTU 1a 2a eircom NGN Node 1 Cabinet DSLAM 6 Operator Network eircom Exchange 1 2 1 RG RG (CPE) (CPE) 3 1 4 1 S -VLAN 2 5 1 S - VLAN 2 ONT RG RG (CPE) (CPE) S -VLAN 1 S - VLAN 1 eircom NGN Node OLT ONT End User Traffic 802.1p marking VDSL DSLAM (C -VLAN 10) VDSL VDSL modem modem RG RG (CPE) (CPE) VPLS # 1 S -VLAN 1 C -VLAN Master Socket VPLS # 2 S -VLAN 2 RG RG (CPE) (CPE) VDSL VDSL modem modem C -VLAN Master Socket 2a 3a 17 1a NTU Operator Operator Network Network S -VLAN S -VLAN 2 16 6 1 5 1 3 1 4 1 1 CPE S-VLAN ONT End-User Traffic 802.1p marking (C-VLAN 10) OLT S-VLAN VPLS Access Connections eircom ODF C-VLAN CPE S-VLAN NTU Cabinet DSLAM 6a 5a 4a eircom NGN Node 2 Operator Network eircom Exchange 6 1 5 2 1 RG RG (CPE) (CPE) 4 3 1 3 5 1 S -VLAN 2 S - VLAN 2 ONT RG RG (CPE) (CPE) S -VLAN 1 S - VLAN 1 eircom NGN Node OLT ONT End User Traffic 802.1p marking VDSL DSLAM (C -VLAN 10) VDSL VDSL modem modem RG RG (CPE) (CPE) VPLS # 1 S -VLAN 1 C -VLAN Master Socket VPLS # 2 S -VLAN 2 RG RG (CPE) (CPE) VDSL VDSL modem modem C -VLAN Master Socket 5a 2a 4a 3a 11 6a 1a NTU Operator Operator Network Network S -VLAN S -VLAN 2 12 6 1 2 4 1 3 1 5 1 7 CPE S-VLAN ONT End-User Traffic 802.1p marking (C-VLAN 10) OLT S-VLAN VPLS Access Connections eircom ODF C-VLAN CPE S-VLAN NTU 2a eircom NGN Node 1 Cabinet DSLAM 6 Operator Network eircom Exchange 1 2 1 3 1 4 1 5 1 STB STB RG RG (CPE) (CPE) S - VLAN 2 S-VLAN 2 eircom ONT NGN Node STB STB S-VLAN 2 RG RG (CPE) (CPE) S-VLAN 1 OLT ONT Access Connections STB STB VPLS #1 Cabinet DSLAM RG RG (CPE) (CPE) VDSL VDSL modem modem Master Socket VPLS #2 S-VLAN 1 C-VLAN STB STB S - VLAN 2 C-VLAN VDSL VDSL 1a modem modem 8 2a 7 3a eircom NTU S-VLAN 1 Operator Operator Network Network BTV Sources S-VLAN 2 1 Master Socket 1 RG RG (CPE) (CPE) 6 1 2 1 4 1 3 1 5 1 6 1 7 1 eircom NGN Network CPE S-VLAN ONT OLT VPLS Access Connections End-User Traffic 802.1p marking (C-VLAN 10) S-VLAN eircom NTU C-VLAN CPE S-VLAN NTU Cabinet DSLAM 1a 2a eircom NGN Node eircom NGN Node Operator Network Operator Handover Site 1 RG (CPE) 2 1 3 1 4 1 5 1 S-VLAN 1 6 1 E-NNI GigE Optical or Electrical Port eircom NGN Network ONT 7 1 WEIL #1 S-VLAN 1 VPLS #1 RG (CPE) S-VLAN 2 OLT ONT eircom NTU VDSL modem eircom NGN Node C-VLAN eircom NGN Node Operator Handover Site WEIL #2 S-VLAN 1 Master Socket S-VLAN 2 RG (CPE) Operator Network S-VLAN #2 VPLS #2 End User Traffic 802.1p marking (C-VLAN 10) RG (CPE) S-VLAN #1 S-VLAN 2 VDSL modem C-VLAN Cabinet DSLAM Master Socket 1a Operator Network S-VLAN #2 eircom NTU 2a 3a Operator Handover Site 6 1 5 1 3 1 4 1 2 1 1 eircom NGN Network CPE S-VLAN ONT OLT VPLS Access Connections End-User Traffic 802.1p marking (C-VLAN 10) Operator Network S-VLAN eircom NTU C-VLAN CPE S-VLAN Operator Handover Site NTU eircom NGN Node Cabinet DSLAM 6a 6 1 RG (CPE) 5a 5 1 eircom NGN Node 4a 4 1 3 1 2 1 S-VLAN 1 E-NNI GigE Optical or Electrical Port eircom NGN Network ONT 1 WEIL #1 S-VLAN 1 VPLS #1 RG (CPE) S-VLAN 2 OLT ONT eircom NTU VDSL modem eircom NGN Node C-VLAN eircom NGN Node Operator Handover Site WEIL #2 S-VLAN 1 Master Socket S-VLAN 2 RG (CPE) Operator Network S-VLAN #2 VPLS #2 End User Traffic 802.1p marking (C-VLAN 10) RG (CPE) S-VLAN #1 S-VLAN 2 VDSL modem C-VLAN Cabinet DSLAM Master Socket 6a Operator Network S-VLAN #2 eircom NTU 5a 4a Operator Handover Site 2 1 1 3 1 9 1 4 1 CPE 5 1 6 1 7 1 S-VLAN ONT OLT Access Connections MVPN VPLS eircom NGN Node C-VLAN CPE eircom NGN PE eircom NGN PE 3 1 eircom NTU eircom NGN Node 1 Gbit/s Access Connection Cabinet DSLAM 2 1 Operator Network S-VLAN eircom NGN Network NTU 1a 1 10 1 8 1 Operator Handover Site E-NNI GigE Optical or Electrical Port 4 1 STB STB S-VLAN 1 RG RG (CPE) (CPE) S-VLAN 1 ONT 5 1 6 1 7 1 8 1 9 1 10 1 11 1 STB STB S-VLAN 2 RG RG (CPE) (CPE) S-VLAN OLT VPLS #1 ONT MVPN #1 MVPN #2 STB STB RG RG (CPE) (CPE) VPLS #2 C-VLAN VDSL VDSL modem modem STB STB S-VLAN S-VLAN C-VLAN VDSL VDSL 1a modem modem Cabinet DSLAM Master Socket 1a 1 2a 1 eircom NGN PE 3a 4a eircom NGN Agg Node Operator Network S-VLAN #2 eircom NGN PE eircom NGN Network Master Socket RG RG (CPE) (CPE) S-VLAN #1 eircom NGN Agg Node 1 Gbit/s Access Connection eircom NTU E-NNI GigE Optical or Electrical Port Operator Handover Site BTV Sources ONT Operator A User 1 VLAN 1100 ONT eircom NGN Node OLT eircom NGN Node VLAN 1100 Operator A User 2 VLAN 1100 ONT SVLAN 10 SVLAN 20 VPLS VLAN 1200 VLAN 1200 Operator B User 1 WEIL VPLS ONT Operator A Handover Site eircom NTU VLAN 1200 Operator B User 2 Operator B Handover Site ONT Operator A User 3 VLAN 1100 ONT WEIL VPLS OLT VLAN 1100 Operator A User 4 VLAN 1100 ONT Operator B User 3 ONT VLAN 1200 VLAN 1200 eircom NGN Node VLAN 1200 Operator B User 4 Operator A User 5 Operator B User 5 VPLS CPE NTU CPE NTU Cabinet DSLAM eircom NGN Node SVLAN 10 SVLAN 20 eircom NTU Operator A User 1 IGMP join 239.1.1.1 eircom NGN PE ONT RG CPE (CPE) 1100 = unicast 1101 = multicast ONT eircom NGN Node OLT Operator A User 2 MVPNx VPLS Operator B User 3 VPLS MVPN WEIL Multicast Core eircom NGN Network 1200 = unicast 1201 = multicast eircom NTU MVPN MVPN ONT Operator A Handover Site MVPNy VLAN 1101 VLAN 1201 eircom NGN Node MVPN MVPN ONT eircom NGN PE PIM adjacency Operator B User 4 WEIL NGN Node 1 Unicast NGN Node 2 Unicast Multicast RP Operator Network Frame          CPE Frame 10 OLT/ DSLAM Frame S   Eircom exchange eircom NGN Node (NGA node) CPE C-VLAN S-VLAN NTU Cabinet DSLAM CPE VPLS C-VLAN NTU CPE S-VLAN NGN core C-VLAN Network Operator Cabinet DSLAM - NTU S-VLAN NGN NTU eircom NGN Node (“non-NGA node) WEIL Service Access Bandwidth 1 open eir NGN Network Individual WSEA Logical Connections Individual Logical Connections to OLT/DSLAMs WEIL Service Access Bandwidth 2 EF AF BE SAP EF AF BE SAP E-NNI EF AF BE SAP EF AF BE SAP EF AF BE SAP open eir NTU WEIL Service Access Bandwidth 3 open eirNGN Node Version 2.0 November 2012 NTU Installation Manual for NGA FTTC Connections in National Roll-Out NTU Installation Manual for NGA FTTC Connections in National Roll-Out   NTU Installation Manual for NGA FTTC Connections in National Roll-Out + = (a) NTU (b) Base of NTU Line In terminates on L1 and L2 (d) Rear of Base           (c) Rear of Removable Faceplate NTU Installation Manual for NGA FTTC Connections in National Roll-Out L1 NGA VUA/BS+ NTU + Splitter Line In L2 Internal Wiring Activity Alarm In Alarm Out S POTS for internal Distribution The DSL port of the Home Gateway is plugged in to the DSL socket in the splitter facing plate POTS appears on the phone socket on the splitter facing plate Alarm can also be wired off alarm terminals on splitter facing plate DSL Home Gate way NTU Installation Manual for NGA FTTC Connections in National Roll-Out POTS DSL Alarm Connections, IN Pair to Alarm OUT Pair from Alarm Cut these resistors for Alarm Installation Internal Wiring taken from L1 and L2 NTU Installation Manual for NGA FTTC Connections in National Roll-Out NGA VUA/BS+ Line In Internal Wiring Activity NTU DS L Home Gate way NTU Installation Manual for NGA FTTC Connections in National Roll-Out ONT Installation Manual for NGA FTTH Connections in National Roll-Out ONT Installation Manual for NGA FTTH Connections in National Roll-Out ONT Installation Manual for NGA FTTH Connections in National Roll-Out ONT Installation Manual for NGA FTTH Connections in National Roll-Out ONT Installation Manual for NGA FTTH Connections in National Roll-Out