Preview only show first 10 pages with watermark. For full document please download

Operating Manual: Avoz-h1-b Laser Diode Driver (pulsed Voltage) (433 Kb, 2016-01-25)

   EMBED


Share

Transcript

AVT E C H ELECTROSYSTEMS N A N O SE C O N D P.O. BOX 265 OGDENSBURG, NY U.S.A. 13669-0265 TEL: 888-670-8729 (USA & Canada) or +1-613-686-6675 (Intl) FAX: 800-561-1970 (USA & Canada) or +1-613-686-6679 (Intl) [email protected] - LTD. W AVEF O R M E L E C T RO N I C S S I N C E 1 9 7 5 http://www.avtechpulse.com/ INSTRUCTIONS MODEL AVOZ-H1-B 60 VOLT, 6 AMP PULSE GENERATOR WITH IEEE 488.2 AND RS-232 CONTROL SERIAL NUMBER: ____________ X BOX 5120, LCD MERIVALE OTTAWA, ONTARIO CANADA K2C 3H5 2 WARRANTY Avtech Electrosystems Ltd. warrants products of its manufacture to be free from defects in material and workmanship under conditions of normal use. If, within one year after delivery to the original owner, and after prepaid return by the original owner, this Avtech product is found to be defective, Avtech shall at its option repair or replace said defective item. This warranty does not apply to units which have been dissembled, modified or subjected to conditions exceeding the applicable specifications or ratings. This warranty is the extent of the obligation assumed by Avtech with respect to this product and no other warranty or guarantee is either expressed or implied. TECHNICAL SUPPORT Phone: 888-670-8729 (USA & Canada) or +1-613-686-6675 (International) Fax: 800-561-1970 (USA & Canada) or +1-613-686-6679 (International) E-mail: [email protected] World Wide Web: http://www.avtechpulse.com 3 TABLE OF CONTENTS WARRANTY......................................................................................................................2 TECHNICAL SUPPORT....................................................................................................2 TABLE OF CONTENTS....................................................................................................3 INTRODUCTION...............................................................................................................5 AVAILABLE OPTIONS.....................................................................................................6 SPECIFICATIONS.............................................................................................................7 REGULATORY NOTES....................................................................................................8 FCC PART 18.......................................................................................................................... 8 EC DECLARATION OF CONFORMITY...................................................................................8 DIRECTIVE 2002/95/EC (RoHS).............................................................................................9 DIRECTIVE 2002/96/EC (WEEE)............................................................................................9 FIRMWARE LICENSING.......................................................................................................10 INSTALLATION...............................................................................................................11 VISUAL CHECK.................................................................................................................... 11 POWER RATINGS................................................................................................................. 11 CONNECTION TO THE POWER SUPPLY............................................................................11 PROTECTION FROM ELECTRIC SHOCK...........................................................................12 ENVIRONMENTAL CONDITIONS.........................................................................................13 LABVIEW DRIVERS.............................................................................................................. 13 FUSES.............................................................................................................................14 AC FUSE REPLACEMENT...................................................................................................14 DC FUSE REPLACEMENT...................................................................................................15 FUSE RATINGS..................................................................................................................... 15 FRONT PANEL CONTROLS..........................................................................................16 REAR PANEL CONTROLS............................................................................................18 GENERAL INFORMATION.............................................................................................20 BASIC PULSE CONTROL....................................................................................................20 TRIGGER MODES................................................................................................................ 22 PULSE WIDTH MODES........................................................................................................ 22 GATING MODES................................................................................................................... 22 THE LOAD AND OUTPUT MODULE....................................................................................23 PREVENTING OUTPUT STAGE FAILURE...........................................................................24 OPERATIONAL CHECK.................................................................................................25 4 PROGRAMMING YOUR PULSE GENERATOR............................................................28 KEY PROGRAMMING COMMANDS....................................................................................28 ALL PROGRAMMING COMMANDS.....................................................................................30 MECHANICAL INFORMATION......................................................................................32 TOP COVER REMOVAL........................................................................................................32 RACK MOUNTING................................................................................................................ 32 ELECTROMAGNETIC INTERFERENCE..............................................................................32 MAINTENANCE..............................................................................................................33 REGULAR MAINTENANCE..................................................................................................33 CLEANING............................................................................................................................ 33 WIRING DIAGRAMS.......................................................................................................34 WIRING OF AC POWER.......................................................................................................34 PCB 158Q - LOW VOLTAGE POWER SUPPLY, 1/3.............................................................35 PCB 158Q - LOW VOLTAGE POWER SUPPLY, 2/3.............................................................36 PCB 158Q - LOW VOLTAGE POWER SUPPLY, 3/3.............................................................37 PCB 104F - KEYPAD / DISPLAY BOARD, 1/3......................................................................38 PCB 104F - KEYPAD / DISPLAY BOARD, 2/3......................................................................39 PCB 104F - KEYPAD / DISPLAY BOARD, 3/3......................................................................40 MAIN WIRING - POSITIVE (-P) UNITS.................................................................................41 PERFORMANCE CHECK SHEET.................................................................................42 Manual Reference: /fileserver2/officefiles/instructword/avoz/AVOZ-H1-B,ed1.odt. Last modified January 25, 2016. Copyright © 2016 Avtech Electrosystems Ltd, All Rights Reserved. 5 INTRODUCTION The AVOZ-H1-B is a high performance, GPIB and RS232-equipped pulser generator that features five identical outputs. These outputs can either be combined to drive a single low-impedance (10 Ohm) load, or can be used separately to drive multiple 50 Ohm loads simultaneously. This unique flexibility makes the AVOZ-H1-B ideal for testing high-current laser diode arrays, as well as testing multiple identical lower-current devices (for instance, production testing of attenuators). The AVOZ-H1-B is capable of generating up to 60V on each of its five identical outputs, at repetition rates up to 50 kHz. The pulse width is variable from 200 ns to 200 ms, and the duty cycle may be as high as 80% in the pulse mode, or 100% in the DC mode. Rise and fall times are fixed at less than 100 ns. The AVOZ-H1-B includes an internal trigger source, but it can also be triggered or gated by an external source. A front-panel pushbutton can also be used to trigger the instrument. The output pulse width can be set to follow an input trigger pulse width. The five outputs are all wired to the same point internally, and thus share common timing and amplitude controls. If the five outputs are connected to a common 10 Ohm load, the AVOZ-H1-B can deliver up to 6 Amps of pulsed current to the load. An optional output module is available to simplify the connection of a single load to the multiple outputs. Cable kits are also optionally available. The output voltage polarity depends on the model number: "-P" units: up to +60 Volts "-N" units: up to -60 Volts The AVOZ-H1-B features front panel keyboard and adjust knob control of the output pulse parameters along with a four line by 40-character backlit LCD display of the output amplitude, pulse width, pulse repetition frequency, and delay. The instrument includes memory to store up to four complete instrument setups. The operator may use the front panel or the computer interface to store a complete “snapshot” of all key instrument settings, and recall this setup at a later time. The instrument is protected against overload conditions (such as short circuits) by an automatic control circuit. An internal power supply monitor removes the power to the output stage for five seconds if an average power overload exists. After that time, the unit operates normally for one second, and if the overload condition persists, the power is cut again. This cycle repeats until the overload is removed. This instrument is intended for use in research, development, test and calibration laboratories by qualified personnel. 6 AVAILABLE OPTIONS -CK5 Option: Cable kit (five RG-58C/U cables, 5ft/152cm) -OM5 Option: Output module, with five input connectors and one output connector. -R5 Option: Rack-mount kit. -VXI Option: Adds a rear-panel Ethernet connector, allowing the instrument to be remotely controlled using the VXI-11.3, ssh (secure shell), telnet, and http (web) protocols. In particular, the VXI-11.3 features allows software like LabView to control an instrument using standard VISA communications drivers and network cabling, instead of using old-style GPIB cabling. (This eliminates the need for a GPIB controller card and its proprietary drivers.) 7 SPECIFICATIONS Model1: Amplitude: AVOZ-H1-B voltage (each output): current (sum of all outputs): Minimum load impedance: (parallel combination of loads on all outputs) Maximum number of 50Ω loads (if outputs used separately): Pulse width: Rise & fall times (20%-80%): Pulse repetition frequency (PRF): Maximum duty cycle: Output impedance (approx.): Average output power Droop: Polarity: GPIB & RS-232 control1: LabView drivers: Ethernet port, for remote control using VXI11.3, ssh, telnet, & web: 3V to 60V, adjustable 0 to 6A 10 Ω The load must be non-inductive2 5 200 ns - 200 ms, or DC. In the external trigger mode, the output pulse width may also be set to track the input pulse width (PW OUT = PW IN mode). < 100 ns 1 Hz to 50 kHz, adjustable 80% in the pulse mode. 100% in the DC mode. 0.1 Ohms 60V × 6A = 360 Watts, maximum < 5%, at maximum pulse width and maximum amplitude Positive or negative (specify3) Standard on -B units.See http://www.avtechpulse.com/gpib for details. Check http://www.avtechpulse.com/labview for availability and downloads Optional4. Recommended as a modern alternative to GPIB / RS-232. See http://www.avtechpulse.com/options/vxi for details. Settings resolution: The resolution of the timing parameters varies, but is always better than 0.15% of the set value. The amplitude resolution is typically 0.02% of the maximum amplitude. Settings accuracy: Typically ± 3% (plus ±1V or ± 2 ns) after 10 minute warmup. For high-accuracy applications requiring traceable calibration, verify the output parameters with a calibrated oscilloscope. Propagation delay: Jitter: Trigger modes: Variable delay. (Sync Out to Main Out) Sync output: Gate input: Output connectors: (see above for quantity) Number of output connectors: Optional cable kit: (RG58C/U cables, 5 feet / 152 cm) Optional output module (for combining multiple outputs on to a single Type-N connector): Other connectors: Power requirement: Dimensions: Chassis material: Temperature range: < 200 ns (Ext trig in to pulse out) ± 100 ps ± 0.03% of sync delay (Ext trig in to pulse out) Internal trigger, external trigger (TTL level pulse, > 10 ns, 1 kΩ input impedance), front-panel “Single Pulse” pushbutton, or single pulse trigger via computer command. 0 to 1.0 seconds, for all trigger modes (including external trigger). +3 Volts, 100 ns, will drive 50 Ohm loads Synchronous or asynchronous, active high or low, switchable. Suppresses triggering when active. Mainframe: Multiple SMA female connectors, for connection to an equal number of separate 50 Ohm loads, or for connection to the output module. Optional output module: Multiple SMA female connectors for connection to mainframe, and one Type-N female connector for connection to a low impedance load. 5 5 cables. Add -CK5 to model number. Add -OM5 to the model number. Trig, Gate, Sync: BNC 100 - 240 Volts, 50 - 60 Hz, 500 Watts. Mainframe: 100 x 430 x 375 mm (3.9 x 17 x 14.8”), -OM5 optional output module: 28 x 36 x 58 mm (1.1 x 1.4 x 2.3”) Anodized aluminum, with blue plastic trim +5°C to +40°C 1) -B suffix indicates IEEE-488.2 GPIB and RS-232 control of pulse amplitude, pulse width, delay and PRF. (See http://www.avtechpulse.com/gpib). 2) For applications where additional resistance must be added in series with the device under test, Avtech recommends connecting multiple Ohmite (www.ohmite.com) OYseries ceramic composition resistors in parallel to create a high-power, low-inductance effective resistance. These resistors can be purchased readily at http://www.digikey.com. 3) Indicate desired polarity by suffixing model number with -P or -N (i.e. positive or negative) or -PN for dual polarity option. 4) Add the suffix -VXI to the model number to specify the Ethernet port. 8 REGULATORY NOTES FCC PART 18 This device complies with part 18 of the FCC rules for non-consumer industrial, scientific and medical (ISM) equipment. This instrument is enclosed in a rugged metal chassis and uses a filtered power entry module (where applicable). The main output signal is provided on a shielded connector that is intended to be used with shielded coaxial cabling and a shielded load. Under these conditions, the interference potential of this instrument is low. If interference is observed, check that appropriate well-shielded cabling is used on the output connectors. Contact Avtech ([email protected]) for advice if you are unsure of the most appropriate cabling. Also, check that your load is adequately shielded. It may be necessary to enclose the load in a metal enclosure. If any of the connectors on the instrument are unused, they should be covered with shielded metal “dust caps” to reduce the interference potential. This instrument does not normally require regular maintenance to minimize interference potential. However, if loose hardware or connectors are noted, they should be tightened. Contact Avtech ([email protected]) if you require assistance. EC DECLARATION OF CONFORMITY We Avtech Electrosystems Ltd. P.O. Box 5120, LCD Merivale Ottawa, Ontario Canada K2C 3H5 declare that this pulse generator meets the intent of Directive 2004/108/EG for Electromagnetic Compatibility. Compliance pertains to the following specifications as listed in the official Journal of the European Communities: EN 50081-1 Emission EN 50082-1 Immunity 9 and that this pulse generator meets the intent of the Low Voltage Directive 72/23/EEC as amended by 93/68/EEC. Compliance pertains to the following specifications as listed in the official Journal of the European Communities: EN 61010-1:2001 Safety requirements for electrical equipment for measurement, control, and laboratory use DIRECTIVE 2002/95/EC (RoHS) This instrument is exempt from Directive 2002/95/EC of the European Parliament and of the Council of 27 January 2003 on the Restriction of the use of certain Hazardous Substances (RoHS) in electrical and electronic equipment. Specifically, Avtech instruments are considered "Monitoring and control instruments" (Category 9) as defined in Annex 1A of Directive 2002/96/EC. The Directive 2002/95/EC only applies to Directive 2002/96/EC categories 1-7 and 10, as stated in the "Article 2 - Scope" section of Directive 2002/95/EC. DIRECTIVE 2002/96/EC (WEEE) European customers who have purchased this equipment directly from Avtech will have completed a “WEEE Responsibility Agreement” form, accepting responsibility for WEEE compliance (as mandated in Directive 2002/96/EC of the European Union and local laws) on behalf of the customer, as provided for under Article 9 of Directive 2002/96/EC. Customers who have purchased Avtech equipment through local representatives should consult with the representative to determine who has responsibility for WEEE compliance. Normally, such responsibilities with lie with the representative, unless other arrangements (under Article 9) have been made. Requirements for WEEE compliance may include registration of products with local governments, reporting of recycling activities to local governments, and financing of recycling activities. 10 FIRMWARE LICENSING Instruments with firmware versions 5.00 or higher use open-source software internally. Some of this software requires that the source code be made available to the user as a condition of its licensing. This source code is available upon request (contact [email protected]). Earlier firmware versions do not contain any open source software. 11 INSTALLATION VISUAL CHECK After unpacking the instrument, examine to ensure that it has not been damaged in shipment. Visually inspect all connectors, knobs, liquid crystal displays (LCDs), and the handles. Confirm that a power cord, a GPIB cable, and two instrumentation manuals (this manual and the “Programming Manual for -B Instruments”) are with the instrument. If the instrument has been damaged, file a claim immediately with the company that transported the instrument. POWER RATINGS This instrument is intended to operate from 100 - 240 V, 50 - 60 Hz. The maximum power consumption is 600 Watts. Please see the “FUSES” section for information about the appropriate AC and DC fuses. This instrument is an “Installation Category II” instrument, intended for operation from a normal single-phase supply. CONNECTION TO THE POWER SUPPLY An IEC-320 three-pronged recessed male socket is provided on the back panel for AC power connection to the instrument. One end of the detachable power cord that is supplied with the instrument plugs into this socket. The other end of the detachable power cord plugs into the local mains supply. Use only the cable supplied with the instrument. The mains supply must be earthed, and the cord used to connect the instrument to the mains supply must provide an earth connection. (The supplied cord does this.) Warning: Failure to use a grounded outlet may result in injury or death due to electric shock. This product uses a power cord with a ground connection. It must be connected to a properly grounded outlet. The instrument chassis is connected to the ground wire in the power cord. The table below describes the power cord that is normally supplied with this instrument, depending on the destination region: 12 Destination Region Description Option Manufacturer Part Number United Kingdom, Hong Kong, Singapore, Malaysia BS 1363, 230V, 50 Hz -AC00 Qualtek 370001-E01 Australia, New Zealand AS 3112:2000, 230-240V, 50 Hz -AC01 Qualtek 374003-A01 Continental Europe, Korea, Indonesia, Russia European CEE 7/7 “Schuko” 230V, 50 Hz -AC02 Qualtek 364002-D01 North America, Taiwan NEMA 5-15, 120V, 60 Hz -AC03 Qualtek 312007-01 Switzerland SEV 1011, 230V, 50 Hz -AC06 Qualtek 378001-E01 South Africa, India SABS 164-1, 220-250V, 50 Hz -AC17 Volex 2131H 10 C3 Japan JIS 8303, 100V, 50-60 Hz -AC18 Qualtek 397002-01 Israel SI 32, 220V, 50 Hz -AC19 Qualtek 398001-01 China GB 1002-1, 220V, 50 Hz -AC22 Volex 2137H 10 C3 PROTECTION FROM ELECTRIC SHOCK Operators of this instrument must be protected from electric shock at all times. The owner must ensure that operators are prevented access and/or are insulated from every connection point. In some cases, connections must be exposed to potential human contact. Operators must be trained to protect themselves from the risk of electric shock. This instrument is intended for use by qualified personnel who recognize shock hazards and are familiar with safety precautions required to avoid possibly injury. In particular, operators should: 1. Keep exposed high-voltage wiring to an absolute minimum. 2. Wherever possible, use shielded connectors and cabling. 3. Connect and disconnect loads and cables only when the instrument is turned off. 4. Keep in mind that all cables, connectors, oscilloscope probes, and loads must have an appropriate voltage rating. 5. Do not attempt any repairs on the instrument, beyond the fuse replacement procedures described in this manual. Contact Avtech technical support (see page 2 for contact information) if the instrument requires servicing. Service is to be performed solely by qualified service personnel. 13 ENVIRONMENTAL CONDITIONS This instrument is intended for use under the following conditions: 1. 2. 3. 4. indoor use; altitude up to 2 000 m; temperature 5 °C to 40 °C; maximum relative humidity 80 % for temperatures up to 31 °C decreasing linearly to 50 % relative humidity at 40 °C; 5. Mains supply voltage fluctuations up to ±10 % of the nominal voltage; 6. no pollution or only dry, non-conductive pollution. LABVIEW DRIVERS A LabVIEW driver for this instrument is available for download on the Avtech web site, at http://www.avtechpulse.com/labview. A copy is also available in National Instruments' Instrument Driver Library at http://www.natinst.com/. 14 FUSES This instrument contains four fuses. All are accessible from the rear-panel. Two protect the AC prime power input, and two protect the internal DC power supplies. The locations of the fuses on the rear panel are shown in the figure below: Fuses #1 and #2 (AC fuses) Fuse #4 (DC fuse) Fuse #3 (DC fuse) AC FUSE REPLACEMENT To physically access the AC fuses, the power cord must be detached from the rear panel of the instrument. The fuse drawer may then be extracted using a small flat-head screwdriver, as shown below: Pry out the fuse drawer using a screwdriver. Fuse Drawer 15 DC FUSE REPLACEMENT The DC fuses may be replaced by inserting the tip of a flat-head screwdriver into the fuse holder slot, and rotating the slot counter-clockwise. The fuse and its carrier will then pop out. FUSE RATINGS The following table lists the required fuses: Fuses Nominal Mains Voltage 115 V #1, #2 (AC) 230 V #3 (DC) N/A #4 (DC) N/A Rating 5.0A, 250V, Time-Delay 3.15A, 250V, Time-Delay 1.0A, 250V, Time-Delay 0.5A, 250V, Time-Delay Recommended Replacement Part Case Size Littelfuse Part Digi-Key Stock Number Number 5×20 mm 0218005.HXP F2422-ND 5×20 mm 02183.15HXP F2430-ND 5×20 mm 0218001.HXP F2419-ND 5×20 mm 0218.500HXP F2416-ND The recommended fuse manufacturer is Littelfuse (http://www.littelfuse.com). Replacement fuses may be easily obtained from Digi-Key (http://www.digikey.com) and other distributors. 16 FRONT PANEL CONTROLS 1 2 5 4 3 1. POWER Switch. This is the main power switch. When turning the instrument on, there is normally a delay of 5-10 seconds before anything is shown on the main display. If the main menu does not appear after 30 seconds, turn off the instrument and leave it off for at least 60 seconds before applying power again. Allow 60 seconds before re-powering an instrument that has been switched off. If the power is switched more frequently than that, the turn-on delay may be longer (up to 20 seconds) as the internal software performs filesystem checks, or the instrument may remain unresponsive indefinitely. 2. OVERLOAD Indicator. When the instrument is powered, this indicator is normally green, indicating normal operation. If this indicator is yellow, an internal automatic overload protection circuit has been tripped. If the unit is overloaded (by operating at an exceedingly high duty cycle or by operating into a very low impedance), the protective circuit will disable the output of the instrument and turn the indicator light yellow. The light will stay yellow (i.e. output disabled) for about 5 seconds after which the instrument will attempt to re-enable the output (i.e. light green) for about 1 second. If the overload condition persists, the output will be disabled again (i.e. light yellow) for another 5 seconds. If the overload condition has been removed, the instrument will resume normal operation. This overload indicator may flash yellow briefly at start-up. This is not a cause for concern. 3. SYNC OUT. This connector supplies a SYNC output that can be used to trigger other equipment, particularly oscilloscopes. This signal leads (or lags) the main output by a duration set by the "DELAY" controls and has an approximate amplitude of +3 Volts to RL > 1kΩ with a pulse width of approximately 100 ns. 17 4. LIQUID CRYSTAL DISPLAY (LCD). This LCD is used in conjunction with the keypad to change the instrument settings. Normally, the main menu is displayed, which lists the key adjustable parameters and their current values. The “Programming Manual for -B Instruments” describes the menus and submenus in detail. 5. KEYPAD. Control Name MOVE CHANGE ×10 ÷10 +/EXTRA FINE ADJUST Function This moves the arrow pointer on the display. This is used to enter the submenu, or to select the operating mode, pointed to by the arrow pointer. If one of the adjustable numeric parameters is displayed, this increases the setting by a factor of ten. If one of the adjustable numeric parameters is displayed, this decreases the setting by a factor of ten. If one of the adjustable numeric parameters is displayed, and this parameter can be both positive or negative, this changes the sign of the parameter. This changes the step size of the ADJUST knob. In the extrafine mode, the step size is twenty times finer than in the normal mode. This button switches between the two step sizes. This large knob adjusts the value of any displayed numeric adjustable values, such as frequency, pulse width, etc. The adjust step size is set by the "EXTRA FINE" button. When the main menu is displayed, this knob can be used to move the arrow pointer. 18 REAR PANEL CONTROLS 4 9 8 10 1 3 OUT GATE AMP RS-232 TRIG GPIB 5 6 7 2 Note: some connectors may be in different positions than shown above, depending on the exact combination of options ordered. 1. AC POWER INPUT. An IEC-320 C14 three-pronged recessed male socket is provided on the back panel for AC power connection to the instrument. One end of the detachable power cord that is supplied with the instrument plugs into this socket. 2. AC FUSE DRAWER. The two fuses that protect the AC input are located in this drawer. Please see the “FUSES” section of this manual for more information. 3. DC FUSES. These two fuses protect the internal DC power supplies. Please see the “FUSES” sections of this manual for more information. 4. GATE. This TTL-level (0 and +5V) logic input can be used to gate the triggering of the instrument. This input can be either active high or active low, depending on the front panel settings or programming commands. (The instrument triggers normally when this input is unconnected). When set to active high mode, this input is pulleddown to ground by a 1 kΩ resistor. When set to active low mode, this input is pulledup to +5V by a 1 kΩ resistor. 5. TRIG. This TTL-level (0 and +5V) logic input can be used to trigger the instrument, if the instrument is set to triggering externally. The instrument triggers on the rising edge of this input. The input impedance of this input is 1 kΩ. (Depending on the length of cable attached to this input, and the source driving it, it may be desirable to add a coaxial 50 Ohm terminator to this input to provide a proper transmission line termination. The Pasternack (www.pasternack.com) PE6008-50 BNC feed-thru 50 Ohm terminator is suggested for this purpose.) 19 When triggering externally, the instrument can be set such that the output pulse width tracks the pulse width on this input, or the output pulse width can be set independently. 6. GPIB Connector. A standard GPIB cable can be attached to this connector to allow the instrument to be computer-controlled. See the “Programming Manual for -B Instruments” for more details on GPIB control. 7. RS-232 Connector. A standard serial cable with a 25-pin male connector can be attached to this connector to allow the instrument to be computer-controlled. A user name (“admin”) and a password (“default”, as shipped from the factory) are required when logging into a serial terminal session. The internal controller attempts to autosense the parity setting. It may be necessary to send a few return characters before attempting a login in order to provide enough data to allow this auto-sensing to work. (A standard Linux “agetty” process is used to implement serial control internally.) See the “Programming Manual for -B Instruments” for more details on RS-232 control. 8. Network Connector. (Optional feature. Present on -VXI units only.) This Ethernet connector allows the instrument to be remotely controlled using the VXI-11.3, ssh (secure shell), telnet, and http (web) protocols. See the “Programming Manual for -B Instruments” for more details. 9. AMP Connector. Not used. 10. OUT Connectors. These five SMA connectors provide the main output signals. For best results, each output should be terminated with a 50Ω load (or, equivalently, all five outputs may be connected to a common 10Ω load). These five connectors are all wired to the same point internally. 20 GENERAL INFORMATION BASIC PULSE CONTROL This instrument can be triggered by its own internal clock or by an external TTL trigger signal. In either case, two output channels respond to the trigger: OUT and SYNC. The OUT channel is the signal that is applied to the load. Its amplitude and pulse width are variable. The SYNC pulse is a fixed-width TTL-level reference pulse used to trigger oscilloscopes or other measurement systems. When the delay is set to a positive value the SYNC pulse precedes the OUT pulse. When the delay is set to a negative value the SYNC pulse follows the OUT pulse. These pulses are illustrated below, assuming internal triggering and a positive delay: SYNC OUT (generated by the internal oscillator) 100 ns, FIXED 3V, FIXED DELAY > 0 PULSE WIDTH AMPLITUDE, VARIABLE MAIN OUTPUT Figure A If the delay is negative, the order of the SYNC and OUT pulses is reversed: 100 ns, FIXED SYNC OUT (generated by the internal oscillator) 3V, FIXED DELAY < 0 PULSE WIDTH AMPLITUDE, VARIABLE MAIN OUTPUT Figure B The next figure illustrates the relationship between the signal when an external TTLlevel trigger is used: 21 > 50 ns TRIG (external input) TTL LEVELS (0V and 3V-5V) PROPAGATION DELAY (FIXED) 100 ns, FIXED SYNC OUT 3V, FIXED DELAY > 0 PULSE WIDTH AMPLITUDE, VARIABLE MAIN OUTPUT Figure C As before, if the delay is negative, the order of the SYNC and OUT pulses is reversed. The last figure illustrates the relationship between the signal when an external TTL-level trigger is used in the PW IN=PW OUT mode. In this case, the output pulse width equals the external trigger’s pulse width (approximately), and the delay circuit is bypassed: PW IN TRIG (external input) TTL LEVELS (0V and 3V-5V) PROPAGATION DELAY (FIXED) PW OUT ≈ PW IN AMPLITUDE, VARIABLE MAIN OUTPUT Figure D The delay, pulse width, and frequency (when in the internal mode), of the OUT pulse can be varied with front panel controls or via the GPIB or RS-232 computer interfaces. 22 TRIGGER MODES This instrument has four trigger modes:  Internal Trigger: the instrument controls the trigger frequency, and generates the clock internally.  External Trigger: the instrument is triggered by an external TTL-level clock on the back-panel TRIG connector.  Manual Trigger: the instrument is triggered by the front-panel “SINGLE PULSE” pushbutton.  Hold Trigger: the instrument is set to not trigger at all. These modes can be selected using the front panel trigger menu, or by using the appropriate programming commands. (See the “Programming Manual for -B Instruments” for more details.) PULSE WIDTH MODES This instrument has two pulse width modes:  Normal: the instrument controls the output pulse width.  PW IN=PW OUT: the output pulse width equals the pulse width of the trigger signal on the “TRIG” connector. The instrument must be in the external trigger mode.  DC mode: the output is a DC voltage (i.e., 100% duty cycle). These modes can be selected using the front panel pulse width menu, or by using the appropriate programming commands. (See the “Programming Manual for -B Instruments” for more details.) GATING MODES Triggering can be suppressed by a TTL-level signal on the rear-panel GATE connector. The instrument can be set to stop triggering when this input high or low, using the frontpanel gate menu or the appropriate programming commands. This input can also be set to act synchronously or asynchronously. When set to asynchronous mode, the GATE will disable the output immediately. Output pulses may be truncated. When set to synchronous mode, the output will complete the full pulse width if the output is high, and then stop triggering. No pulses are truncated in this mode. 23 THE LOAD AND OUTPUT MODULE The AVOZ-H1-B has five identical outputs. These outputs can either be combined to drive a single low-impedance (10 Ohms) load, or can be used separately to drive multiple 50 Ohm loads simultaneously. An output module is optionally available to simplify the connection of a single load to multiple outputs. Up to five identical 50 Ohm coaxial cables (152 cm / 5 feet) are used to connect the mainframe to the output module. Not all cables are necessarily used at the same time; see the table below for recommended cabling when using the output module to drive a single load. Load Impedance (RL) 10 Ohms 11 to 14 Ohms 14 to 20 Ohms 20 to 35 Ohms 35 to  Ohms Number of Cables Used to Connect Mainframe to Output Module (N) 5 4 3 2 1 Effective Z0 of Cabling (Z0 = 50 / N) 10.0 Ohms 12.5 Ohms 16.7 Ohms 25.0 Ohms 50.0 Ohms For instance, to drive a single 10 Ohm load, the following configuration should be used: AVOZ-H1-B MAINFRAME OUT CONNECTORS (5) AC POWER AVOZ-D-OM5 IN (5) OUT (1) GND (SHIELD) SYNC OUTPUT REAL-TIME OSCILLOSCOPE Five coaxial cables SCOPE PROBE CHANNEL A 10 Ω, 360 W TRIG INPUT The output module is not needed if each output is driving its own load, as shown below: 24 AVOZ-H1-B MAINFRAME AC POWER SCOPE PROBE OUT CONNECTOR #1 OUT CONNECTOR #2 OUT CONNECTOR #3 OUT CONNECTOR #4 OUT CONNECTOR #5 SYNC OUTPUT REAL-TIME OSCILLOSCOPE CHANNEL A 50 Ω, 72 W To three other 50 Ohm loads. CHANNEL B 50 Ω, 72 W TRIG INPUT PREVENTING OUTPUT STAGE FAILURE The output stage is protected against overload conditions by an overload circuit and fuses on the main frame back panel. However, the output switching elements may fail if the unit is triggered at a PRF exceeding 50 kHz or at duty cycles resulting in an average output power in excess of 360 Watts. Heating and subsequent possible failure of the output stage is reduced if the following action is taken where possible:  PRF is kept to a minimum, i.e. operate in a low PRF range when possible rather than in a high PRF range.  Keep the output PW to a minimum.  Never apply an externally generated voltage to the output port. 25 OPERATIONAL CHECK This section describes a sequence to confirm the basic operation of the instrument. It should be performed after receiving the instrument. It is a useful learning exercise as well. Before proceeding with this procedure, finish read this instruction manual thoroughly. Then read the “Local Control” section of the “Programming Manual for -B Instruments” thoroughly. The “Local Control” section describes the front panel controls used in this operational check - in particular, the MOVE, CHANGE, and ADJUST controls. AVOZ-H1-B MAINFRAME AC POWER SCOPE PROBE OUT CONNECTOR #1 OUT CONNECTOR #2 OUT CONNECTOR #3 OUT CONNECTOR #4 OUT CONNECTOR #5 SYNC OUTPUT REAL-TIME OSCILLOSCOPE CHANNEL A 50 Ω, 72 W To three other 50 Ohm loads. CHANNEL B 50 Ω, 72 W TRIG INPUT 1. Connect a cable from the SYNC OUT connector to the TRIG input of an oscilloscope. 2. Connect a 50 Ohm load to each of the five outputs, using coaxial cabling. Connect one or more oscilloscope probes to the loads of your choice (all five loads should show the same waveform). 3. Set the oscilloscope to trigger externally with the vertical setting at 20 Volts/div and the horizontal setting at 2 us/div. 4. Turn on the AVOZ-H1-B. The main menu will appear on the LCD. 5. To set the AVOZ-H1-B to trigger from the internal clock at a PRF of 100 Hz: a) The arrow pointer should be pointing at the frequency menu item. If it is not, press the MOVE button until it is. b) Press the CHANGE button. The frequency submenu will appear. Rotate the ADJUST knob until the frequency is set at 100 Hz. 26 c) The arrow pointer should be pointing at the “Internal” choice. If it is not, press MOVE until it is. d) Press CHANGE to return to the main menu. 6. To set the delay to 1 us: a) Press the MOVE button until the arrow pointer is pointing at the delay menu item. b) Press the CHANGE button. The delay submenu will appear. Rotate the ADJUST knob until the delay is set at 1 us. c) The arrow pointer should be pointing at the “Normal” choice. If it is not, press MOVE until it is. d) Press CHANGE to return to the main menu. 7. To set the pulse width to 5 us: a) Press the MOVE button until the arrow pointer is pointing at the pulse width menu item. b) Press the CHANGE button. The pulse width submenu will appear. Rotate the ADJUST knob until the pulse width is set at 5 us. c) The arrow pointer should be pointing at the “Normal” choice. If it is not, press MOVE until it is. d) Press CHANGE to return to the main menu. 8. At this point, nothing should appear on the oscilloscope. 9. To enable the output: a) Press the MOVE button until the arrow pointer is pointing at the output menu item. b) Press the CHANGE button. The output submenu will appear. c) Press MOVE until the arrow pointer is pointing at the “ON” choice. d) Press CHANGE to return to the main menu. 10. To change the output amplitude: 27 a) Press the MOVE button until the arrow pointer is pointing at the amplitude menu item. b) Press the CHANGE button. The amplitude submenu will appear. Rotate the ADJUST knob until the amplitude is set at +60V (or -60V for "-N" instruments). c) Observe the oscilloscope. You should see 5 us wide, 60V pulses. d) Rotate the ADJUST knob. The amplitude as seen on the oscilloscope should vary. e) Press CHANGE to return to the main menu. 11. Repeat step 10, but set the amplitude to zero. 12. This completes the operational check. 28 PROGRAMMING YOUR PULSE GENERATOR KEY PROGRAMMING COMMANDS The “Programming Manual for -B Instruments” describes in detail how to connect the pulse generator to your computer, and the programming commands themselves. A large number of commands are available; however, normally you will only need a few of these. Here is a basic sample sequence of commands that might be sent to the instrument after power-up: *rst trigger:source internal frequency 1000 Hz pulse:width 1 us pulse:delay 2 us volt 60 output on (resets the instrument) (selects internal triggering) (sets the frequency to 1000 Hz) (sets the pulse width to 1 us) (sets the delay to 2 us) (sets the amplitude to 60 V) (turns on the output) To enable the DC output mode: *rst source:func dc volt 60 output on (resets the instrument) (enable DC output mode) (sets the amplitude to 60 V) (turns on the output) For triggering a single pulse, this sequence would be more appropriate: *rst trigger:source hold pulse:width 1 us pulse:delay 2 us output on volt 60 trigger:source immediate trigger:source hold output off (resets the instrument) (turns off all triggering) (sets the pulse width to 1 us) (sets the delay to 2 us) (turns on the output) (sets the amplitude to 60 V) (generates a single non-repetitive trigger event) (turns off all triggering) (turns off the output) To set the instrument to trigger from an external TTL signal applied to the rear-panel TRIG connector, use: *rst trigger:source external pulse:width 1 us pulse:delay 2 us (resets the instrument) (selects external triggering) (sets the pulse width to 1 us) (sets the delay to 2 us) 29 volt 60 output on (sets the amplitude to 60 V) (turns on the output) To set the instrument to trigger from an external TTL signal applied to the rear-panel TRIG connector, and have the output track the input pulse width, use: *rst trigger:source external pulse:width in volt 60 output on (resets the instrument) (selects external triggering) (sets the output pulse width to track the input pulse width) (sets the amplitude to 60 V) (turns on the output) These commands will satisfy 90% of your programming needs. 30 ALL PROGRAMMING COMMANDS For more advanced programmers, a complete list of the available commands is given below. These commands are described in detail in the “Programming Manual for -B Instruments”. (Note: this manual also includes some commands that are not implemented in this instrument. They can be ignored.) Keyword OUTPut: :[STATe] :PROTection :TRIPped? [SOURce]: :FREQuency [:CW | FIXed] :FUNCtion :[SHAPe] :PULSe :PERiod :WIDTh :DCYCle :HOLD :DELay :GATE :TYPE :LEVel [SOURce]: :VOLTage [:LEVel] [:IMMediate] [:AMPLitude] :PROTection :TRIPped? STATUS: :OPERation :[EVENt]? :CONDition? :ENABle :QUEStionable :[EVENt]? :CONDition? :ENABle SYSTem: :COMMunicate :GPIB :ADDRess :SERial :CONTrol :RTS :[RECeive] :BAUD :ERRor :[NEXT]? :COUNT? :VERSion? Parameter Notes [query only] DC | PULSe | EXTernal WIDTh | DCYCle ASYNC | SYNC HIgh | LOw | EXTernal [query only] [query only, always returns "0"] [query only, always returns "0"] [implemented but not useful] [query only, always returns "0"] [query only, always returns "0"] [implemented but not useful] ON | IBFull | RFR 1200 | 2400 | 4800 | 9600 | 19200 | 38400 | 57600 | 115200 [query only] [query only] [query only] 31 TRIGger: :SOURce *CLS *ESE *ESR? *IDN? *OPC *SAV *RCL *RST *SRE *STB? *TST? *WAI INTernal | EXTernal | MANual | HOLD | IMMediate [no query form] [query only] [query only] 0|1|2|3 0|1|2|3 [no query form] [no query form] [no query form] [query only] [query only] [no query form] 32 MECHANICAL INFORMATION TOP COVER REMOVAL If necessary, the interior of the instrument may be accessed by removing the four Phillips screws on the top panel. With the four screws removed, the top cover may be slid back (and off). Always disconnect the power cord and allow the instrument to sit unpowered for 10 minutes before opening the instrument. This will allow any internal stored charge to discharge. There are no user-adjustable internal circuits. For repairs other than fuse replacement, please contact Avtech ([email protected]) to arrange for the instrument to be returned to the factory for repair. Service is to be performed solely by qualified service personnel. Caution: High voltages are present inside the instrument during normal operation. Do not operate the instrument with the cover removed. RACK MOUNTING A rack mounting kit is available. The -R5 rack mount kit may be installed after first removing the one Phillips screw on the side panel adjacent to the front handle. ELECTROMAGNETIC INTERFERENCE To prevent electromagnetic interference with other equipment, all used outputs should be connected to shielded loads using shielded coaxial cables. Unused outputs should be terminated with shielded coaxial terminators or with shielded coaxial dust caps, to prevent unintentional electromagnetic radiation. All cords and cables should be less than 3m in length. 33 MAINTENANCE REGULAR MAINTENANCE This instrument does not require any regular maintenance. On occasion, one or more of the four rear-panel fuses may require replacement. All fuses can be accessed from the rear panel. See the “FUSES” section for details. CLEANING If desired, the interior of the instrument may be cleaned using compressed air to dislodge any accumulated dust. (See the “TOP COVER REMOVAL” section for instructions on accessing the interior.) No other cleaning is recommended. WIRING DIAGRAMS WIRING OF AC POWER 1 2 3 4 5 6 I MON, 1V /A BD 3 PS2 DC + PG G ND DC - OP 1 B AMP -RTN -SENS +SE NS +R TN VP RG M RE F IPRG M INH VM O N IMO N SB US VO K +1 5 V CHANGES ON PCB 249A: IN+ IN+1 5 V -1 5 V GN D OU T 1) U1 = AD711, WITH PINS 1, 5, 8 SNIPPED OFF. 2) ADD 1K BETWEEN U1-2 AND U1-6 D 249A CW 1 2 3 4 5 6 7 8 9 10 11 12 -1 5 V R1 PC B24 9 A W CC W D PG H V+ TO R OLO P AD , NEX T TO TP2 5 K PO T, O LO AD JUST Mains circuits - hazardous live. G N L Y0 7 0LX 6 4 0 -E-D2 A3 - B LA CK X1 POW ER SW I T C H SW 32 5-N D (CW IN DU ST RI ES G RS -40 22-0013) A4 - W H I TE G3 1 REAR PS1 1a N BD 2 PC B1 04E K EYP AD B OA RD L A K V1 V1 R TN V2 R TN V2 TEM P OV AU X G 8 7 6 5 4 3 2 1 4 3 2 1 Molex 19002-0009. 0.187" x 0.032" 2 C 2a A1 - B RO W N A2 - B LU E Safety earth ground / Primary earth ground / Protective conductor terminal. G2 B1 - R ED G V2 - SNS V2 + S NS V1 + S NS V1 - SNS RT N FA IL V1 SH R V2 SH R 2b G4 N AA D1 3 0 SD -60 -A L FRONT C 1b X2 CO RC OM 6 EG G1-2 PO W ER E NT RY MOD ULE G1 - + DC FA N P9 768-ND FA N1 + J8 J2 20 AW G +2 4 , NO O LO GN D PO S O LO OL O GN D NE G OLO /+ IN J3 GN D 20 OR 2 4 A W G 24 AW G + Molex 19073-0013 ring terminal, #8. Install green/yellow wires at bottom of stack, closest to wall. J6 CA P BA NK GN D BU +/ EXT PS GN D -IN /+O UT GN D LV O LO GN D FAN NOT HARNESSED +2 4 V, N O OLO +2 4 V, N O OLO GN D +5 V N SY +5 V R EG -5 V -1 5 V +1 5 V NSY +1 5 V REG +1 0 V J1 +1 0 V +1 5 V -1 5 V -5 V +5 V GN D GN D +5 V +5 V C3 - P UR C4 - G RN B J 10 N/ C DC IN DC IN N/ C DC GN D CH S GN D Molex 19002-0001. 0.250" x 0.032". GN D GN D GN D B Chassis ground post. Secondary earth ground. 20 AW G J4 20 AW G J 9 - FA N A K PO S O LO ON LY U SE D FOR S SR J7 AM B ER GN D J 5 GR EEN PCB 158Q GR N AM B WHT BL K RE D X5 VC C LE D MO UN T BD 1 PC B 1 58 Q Do no t attem pt a ny rep air s on this instrume nt beyon d the fuse r epla cem ent p ro cedur es de scr ib ed i n the m anual . C ontact A v tech if the i nstr um ent requir es serv icing. S erv ice i s to be per for me d W A RNIN G sol ely by qual i fi ed ser v ice per so nnel . CHANGES ON PCB 158Q: A Pri nte d D1 P3 95-ND LE D Re vis i on 21-Jan-2016 Z:\mjcfiles\circuits\avoz\avoz.Ddb - AVOZ-H1-B\H1 PS V2.sch 1 2 3 A AVOZ-H1-B POWER SUPPLY GR N AM B 1) REMOVE U6 (CURRENTSENSE) 2) REMOVE ROLO 3) INSTALL K2 = AQZ102 (FOR INHIBIT FUNCTION) 4) REMOVE R13 (ENABLES K2) 4 5 6 2A PCB 158Q - LOW VOLTAGE POWER SUPPLY, 1/3 1 D 2 X8 X1 3 6 -3 2 1 /4 " SS SC REW , 0 6 0 4 M PP 1 8 8 6 -3 2 SS EXT TO OTH W ASH ER, 0 6 W E1 8 8 X9 X1 4 6 -3 2 1 /4 " SS SC REW , 0 6 0 4 M PP 1 8 8 6 -3 2 SS EXT TO OTH W ASH ER, 0 6 W E1 8 8 X1 2 X1 6 4 -4 0 1 /4 " SS SC REW , 0 4 0 4 M PP 1 8 8 4 -4 0 SS EXT TO OTH W ASH ER, 0 4 W E1 8 8 3 4 5 6 D p cb1 5 8 Q_ o v p p cb1 5 8 Q_ o v p . sch X1 7 +1 5 V X1 9 -1 5 V C +1 5 V GN D -1 5 V BU + P-OU T # 1 J3 6 5 4 3 2 1 2 -5 6 1 /4 " SS SC REW , 0 2 0 4 M PP 1 8 8 2 -5 6 SS EXT TO OTH W ASH ER, 0 2 W E1 8 8 X1 8 X2 0 2 -5 6 1 /4 " SS SC REW , 0 2 0 4 M PP 1 8 8 2 -5 6 SS EXT TO OTH W ASH ER, 0 2 W E1 8 8 6 4 0 4 4 5 -6 X4 X2 3 J4 2 -5 6 1 /4 " SS SC REW , 0 2 0 4 M PP 1 8 8 2 -5 6 SS EXT TO OTH W ASH ER, 0 2 W E1 8 8 8 7 6 5 4 3 2 1 p cb1 5 8 Q_ sw itch i n g p cb1 5 8 Q_ sw itch i n g . sch X5 X2 4 2 -5 6 1 /4 " SS SC REW , 0 2 0 4 M PP 1 8 8 2 -5 6 SS EXT TO OTH W ASH ER, 0 2 W E1 8 8 +1 5 V -1 5 V X2 5 BU + EX T NE G IN +1 5 V GN D -1 5 V P-OU T # 1 C P-OU T # 2 N-O UT CA PB AN K 6 4 0 4 4 5 -8 AMB ER GR EEN P-OU T # 3 # 2 SS FLA T W ASH ER, 0 2W M1 8 8 1 2 3 # 2 SS FLA T W ASH ER, 0 2W M1 8 8 X2 7 1 2 X2 6 B B J7 6 4 0 4 5 6 -2 J5 6 4 0 4 5 6 -3 # 2 SS FLA T W ASH ER, 0 2W M1 8 8 X2 8 # 2 SS FLA T W ASH ER, 0 2W M1 8 8 A A T i tle Da te LOW VOLTAGE DC/DC POWER SUPPLY Re vis i on 25-Sep-2015 Z:\mjcfiles\pcb\158\switching60hz.ddb - 158Q\pcb158Q.sc h 1 2 3 4 5 6 PCB 158Q - LOW VOLTAGE POWER SUPPLY, 2/3 1 2 3 4 5 6 D BA RE 1 5 8 P PCB -1 5 V -1 5 V +1 5 V +1 5 V TP3 TES T-LO OP X TP6 TES T-LO OP 4 A A 6 4 0 4 4 5 -6 J6 S1 A 1 S1 B , OR DC 2 S2 A , OR DC 3 S2 B 4 5 6 X2 2 1 2 PC B1 5 8 AL, V3 B RA CK ET 3 X2 1 B F3 FU SEHO LD ER L5 BU + 7 7 A -1 0 0 M-0 1 C2 0 4 7 u F/5 0 V C2 1 2.2uF C1 6 1 0 0 0 u F/ 35 V R2 0 10K C2 2 1 0 0 0 u F/ 35 V D C1 9 4 7 u F/5 0 V D7 1 . 5 KE 3 9 A GN D +1 0 V +1 5 V REG +1 5 V NSY -1 5 V -5 V +5 V R EG +5 V N SY GN D +2 4 V +2 4 V X6 TIE-DOW N-3 5 0 J2 6 4 0 4 4 5 -9 1 -6 4 0 4 5 6-0 J1 J1 0 R5 0 OH M 3 2 1 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 C C 6 4 0 4 5 6 -3 U2 781 0 P-OU T # 1 Vo u t +1 0 V U5 NO T USE D (7 8 2 4 ) C1 4 7 u F/3 5 V 2 1 U1 + + 2 C1 3 4 7 u F/5 0 V FOR NOIS Y SU BC IR CU IT S C4 4 7 u F/3 5 V U1 1 781 5 1 L2 3 7 7 A -1 0 1 M -0 1 C6 2.2uF PY B1 5 -Q 2 4 -D1 5 J9 6 4 0 4 4 5 -2 +1 5 V Vin Vo u t 3 GN D 1 4 3 C3 2 4 7 u F/3 5 V C3 4 7 u F/3 5 V B 2 C B 7 7 A -1 0 1 M -0 1 C8 2.2uF - -1 5 V Vo u t 1 2 - 2 L1 5 Vin C7 4 7 u F/5 0 V GN D Vin 3 GN D 1 U4 C A 1 + C2 9 NO T USE D (4 7 u F/ 3 5 V) NO T USE D + NO T USE D (4 7 u F/ 3 5 V) C3 0 J12 3 L6 NO T USE D (7 7 A-1 0 1 M-0 1 ) NO RMA LLY U NU SED GN D 3 C3 3 4 7 u F/3 5 V 16 15 14 23 22 Vo u t 2 NO T USE D (2 . 2 u F ) C3 1 4 Vin J11 I N+ I NGN D OU T+ OU T- 1 2 3 4 NO T USE D (6 4 0 4 5 6 -4 ) 1 2 3 4 5 C2 7 NO T USE D (4 7 u F/ 5 0 V) Vin C3 4 4 7 u F/5 0 V Vo u t 3 GN D -OU T N/C +O UT U1 3 OK I-7 8 S R-5 /1 .5 -W 3 6 -C 1 C3 5 4 7 u F/3 5 V 2 5 2 3 - 1 2 3 2 +IN N/ C N/ C U1 0 U8 NO T USE D (MKC 0 3 ) N/C N/C N/C C9 4 7 u F/3 5 V 9 10 11 PY B1 5 -Q 2 4 -D5 +5 V +IN +IN 7 7 A -1 0 1 M -0 1 C1 1 2.2uF -IN -IN L3 3 U1 2 NO T USE D 1 15 14 13 + -5 V C5 4 7 u F/3 5 V -OU T +O UT -IN + 4 -OU T +O UT -IN 7 7 A -1 0 1 M -0 1 C1 2 2.2uF 10 11 12 C 1 L4 5 24 23 22 - +IN N/ C N/ C 2 U9 NO T USE D (SB 0 3 /SB0 5 ) T i tle Da te C2 8 NO T USE D (4 7 u F/ 5 0 V) NO T USE D (6 4 0 4 4 5 -5 ) A DC/DC, AND OVER-VOLTAGE PROTECTION Re vis i on 25-Sep-2015 Z:\mjcfiles\pcb\158\switching60hz.ddb - 158Q\pcb158Q_ovp.sch 1 2 3 4 5 6 PCB 158Q - LOW VOLTAGE POWER SUPPLY, 3/3 1 2 3 4 5 6 R2 1 1 . 5 K OY D6 X2 CA PB AN K R2 6 15K LED HV W AR NING R1 7 D SH OR TS OU T B AS E W HE N CH AR GING. 4 NO T USE D (0 ) 3 EX T R1 5 + - 3 1 1 C2 5 4 7 u F/5 0 V D4 R4 150 2 E-2 7 2 (O R 1 N 5 3 0 5 ) 3 R2 4 2 4 NO T USE D (G 2 RL -1 4 -D C2 4 ) R2 8 V+ P-OU T # 1 120 OY 5.1K K3 D2 1N4148 R2 3 2 470 1N4733A D1 0 + 1 - +1 5 V R2 4 2 14 470 R2 2 R2 7 100 - + - 3 R1 -1 5 V + - K2 NE G IN - + - + R6 2 470 4 N-O UT R1 3 470 NO T USE D (A QZ1 0 2 ) NO T USE D (0 ) 3 1 +1 5 V D1 1N 4736A C1 5 NO T USE D (A QZ1 0 2 ) Q1 C M PQ2 2 2 2 R1 1 4.7K 12 300 C2 4 4 7 u F/3 5 V B + C U6 LT6 1 0 6 C S5 K6 4 P-OU T # 2 1 3 2 - 3 - 0 OH M AQ Z1 0 2 1N4148 DIS ABL E AT POW ER -ON (+15V LA GS H V BY 5 00 ms ) + 2 1 + 3 1 4 D9 DIS ABL E AT POW ER -OFF GN D R1 0 OU T 300 Q1 D MPQ2 2 2 2 10 R1 4 8 C R3 AQ Z1 0 2 K1 W LA R1 0 0 FE (0 . 1 OH M S) 1 0.1uF U7 8 V+ R7 75K 4 2 6 5 7 1 DI S ABL E OLO W HEN CH ARGING. TES T-LO OP TP2 Q1 A MPQ2 2 2 2 3 1 C2 C1 8 2 2 0 u F,1 6 V C1 7 0.1uF GN D AMB ER 680 B +1 5 V 3 R1 8 1.2K R1 6 1.2K GR EEN SE5 5 5 P R1 2 1K Q1 B M PQ2 2 2 2 5 R9 3K C1 4 4 7 u F/3 5 V RE SET TR IG TH R OU T CO NT DIS R1 9 7 2 5 C TQ0 4 0 PB F, IN 5 9 1 2 0 2 B0 4 0 0 0 G H EAT SIN K C1 0 4 7 u F/5 0 V 4 5 +IN 2 P-OU T # 3 R8 NO T USE D (2 2 A Y) TP5 1 3 Vo u t W LA R1 0 0 FE (0 . 1 OH M S) 3 D5 - NO T USE D (A QZ1 0 2 ) R2 5 5 TES T-LO OP + Vin 2 0.1uF 2 X B 4 K5 TES T-LO OP U3 781 2 K7 C2 6 4 3 TP4 1 2 A A F2 FU SEHO LD ER GN D K4 PS7 2 0 6 -1 A-F3 -A 0 OH M -IN BU + 1 D C2 3 1 0 0 0 u F/3 5 V TP1 X3 6 -3 2 MO UN T X1 KE YSTO NE 6 2 1 TES T-LO OP A -1 5 V X1 0 6 -3 2 MO UN T -1 5 V NO T USE D (1 0 0 0 u F/ 3 5 V ) A X7 T i tle +1 5 V +1 5 V OVER-CURRENT PROTECTION 5 9 1 2 0 2 B 0 4 0 0 0 G HEA TSINK , IN STA LLED A S LOW AS PO SSIBLE Da te GN D Re vis i on 25-Sep-2015 Z:\mjcfiles\pcb\158\switching60hz.ddb - 158Q\pcb158Q_switching.s ch 1 2 3 4 5 6 PCB 104F - KEYPAD / DISPLAY BOARD, 1/3 1 2 3 4 5 6 D D Amp 5 4 9 9 9 1 0 -1 , 1 0 p in strai g h t h ead er J5 1 2 3 4 5 6 7 8 9 10 C C LC D-BU TT LC D-BU TT. SCH SD A SC L GN D VC C VC C-LED BA CK LIGH T EN CO DER EN CO DER .S CH SD A SC L GN D VC C B I2 C_ INT SING LE PUL SE B BA CK LIGH T A A T i tle Da te PANEL TOP-LEVEL SCHEMATIC Re vis i on 25-Sep-2015 Z:\mjcfiles\pcb\104f\keypad-2015.ddb - Documents\Panelbrd.prj 1 2 3 4 5 6 PCB 104F - KEYPAD / DISPLAY BOARD, 2/3 1 2 3 4 5 6 U4 A VC C C1 0 BU T1 D U7 1 2 3 4 5 6 7 8 Q1 BU T1 MMBT2 2 2 2 ABU T2 BU T3 BU T4 R1 1 2 15K 2 VC C 1 VC C 2.2uF R4 15K VC C 16 15 14 13 12 11 10 9 A0 VC C A1 SD A A2 SC L P0 INT P1 P7 P2 P6 P3 P5 GN D P4 MM7 4 HC 1 4 N GN D C4 0.1uF C1 5 0.1uF C1 3 0.1uF U4 B C1 1 BU T2 4 D 3 2.2uF BU T6 BU T5 MM7 4 HC 1 4 N U4 C PC F8 5 7 4 AN (MU ST HA VE "A" IN P/N ) J8 6 4 0 4 5 6 -2 C2 0.1uF C1 2 BU T3 6 5 2.2uF U6 4 5 14 11 15 1 10 9 MM7 4 HC 1 4 N CT EN D/ U CL K LO AD A B C D M AX /MIN RC O QA QB QC QD 12 13 U4 D C9 3 2 6 7 CN T4 CN T5 CN T6 CN T7 BU T4 8 9 2.2uF MM7 4 HC 1 4 N U4 E SN 7 4 HC 1 9 1 D C7 BU T5 U1 D C 8 4 5 14 11 15 1 10 9 M M7 4 HC 1 4 N 11 X6 U8 9 10 CT EN D/ U CL K LO AD A B C D M AX /MIN RC O QA QB QC QD 12 13 3 2 6 7 2.2uF VC C CN T0 CN T1 CN T2 CN T3 C MM7 4 HC 1 4 N 1 2 3 4 5 RE D, +5 V OR AN GE , B YE LLOW , A GR EEN , GN D U4 F C6 BU T6 12 13 2.2uF MM7 4 HC 1 4 N SO LDER PAD S SN 7 4 HC 1 9 1 D U1 E C1 SING LE PUL SE X4 C1 4 VC C C1 6 0.1uF 2.2uF VC C 1 2 3 4 5 VC C 0.1uF 0.1uF RE D, +5 V OR AN GE , B YE LLOW , A GR EEN , GN D 1 x 5 SEC TION O F BRE AK AW A Y HEA DE R, R EMOV E P IN 2 VC C B U3 1 2 3 4 5 6 7 8 A0 VC C A1 SD A A2 SC L P0 INT P1 P7 P2 P6 P3 P5 GN D P4 VC C 16 15 14 13 12 11 10 9 11 MM7 4 HC 1 4 N RN 2 RN 1 8 7 6 5 4 3 2 1 RN 3 4 6 0 8 X-1 -4 7 3 LF-N D 1 2 3 4 5 6 7 8 B 1 2 3 4 5 6 7 8 C3 VC C 10 4 6 0 8 X-2 -1 0 1 LF-N D VC C 4 6 0 8 X-2 -1 0 1 LF-N D J7 AU X OV TEM P 3 2 1 X5 8 2 -6 0 1 -8 1, 6 b u tt o n k ey p ad 6 4 0 4 5 6 -3 PC F8 5 7 4 AN (MU ST HA VE "A" IN P/N ) M OV E 1A U2 VC C CN T0 CN T1 CN T2 CN T3 1 2 3 4 5 6 7 8 A0 VC C A1 SD A A2 SC L P0 INT P1 P7 P2 P6 P3 P5 GN D P4 VC C 16 15 14 13 12 11 10 9 CN T7 CN T6 CN T5 CN T4 6A 2B 5A 3B 4A X1 0 SD A SC L I2 C_ INT 2A 6B /1 0 5B X2 8 2 -1 0 1 -7 1, 1 b u tt o n k ey p ad +/ 1A PC F8 5 7 4 AN (MU ST HA VE "A" IN P/N ) A CH AN GE 1B 1B 3A EX TRA F IN E 4B R2 100 K A T i tle VC C Da te ENCODER, BUTTONS, AND PLD Re vis i on 25-Sep-2015 Z:\mjcfiles\pcb\104f\keypad-2015.ddb - Documents\ENCODER.SCH 1 2 3 4 5 6 PCB 104F - KEYPAD / DISPLAY BOARD, 3/3 1 2 3 4 5 6 VC C VC C C5 0.1uF GN D C8 2.2uF D D VC C U5 1 2 3 4 5 6 7 8 PA D3 PA D4 LED + LED - A0 VC C A1 SD A A2 SC L P0 INT P1 P7 P2 P6 P3 P5 GN D P4 VC C 16 15 14 13 12 11 10 9 SD A SC L PC F8 5 7 4 AN (MU ST HA VE "A" IN P/N ) C U1 A LC D POW E R C U1 C 1 2 5 M M7 4 HC 1 4 N 6 M M7 4 HC 1 4 N VC C U1 B 3 U1 F 4 13 MM7 4 HC 1 4 N RN 4 R3 22 VC C 12 M M7 4 HC 1 4 N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 VC C 16 4 8 1 6 P-2 -1 0 2 LFC T-N D B B CC W X1 0 R5 1 2 2 4 6 8 10 12 14 16 18 TP1 TES T-LO OP W CW 3 TO P V IEW 4 -4 0 MO UN T 4 -4 0 MO UN T X3 X1 X9 X8 4 -4 0 MO UN T 4 -4 0 MO UN T PO T, 3 2 6 6 X 1 0 K H OR IZ 1 3 5 7 9 11 13 15 17 DB 6 DB 7 DB 4 DB 5 DB 2 DB 3 DB 0 DB 1 R/W E1 VE E RS VC C VS S NC E2 LED - LED + A3 2 7 0 7 -0 9 -ND VC C VC C R6 BL 0 A A T i tle Da te LCD CIRCUITS, MECHANICAL Re vis i on 25-Sep-2015 Z:\mjcfiles\pcb\104f\keypad-2015.ddb - Documents\LCD-BUTT.SCH 1 2 3 4 5 6 MAIN WIRING - POSITIVE (-P) UNITS 1 2 3 4 5 6 D D BD 1 OP 1 B MAIN BO AR D, P CB 2 5 5 D +5 V SY NC 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 M1 M TR IG GN D GN D GN D N/C LV + +5 V N/C SSR HV OT /V REF OU T 1 / 5 C OU T 5 / 5 PG -P CH S GN D PO S O LO 5 X OU TPU TS SR 405 C OA X OP 1 B AMP B +1 5 V ON /O FF +5 V O N/ OF F MAIN OU T SY NC O UT EX T T RIG GA TE XR LY 1 XR LY 2 (DU AL PW ) XR LY 3 (V-I) XR LY 4 (EO) XR LY 5 AMPL RN G 0 AMPL RN G 1 AMPL RN G 2 AMPL RN G 3 AMPL RN G 4 O. SPE EDU P-RNG O. EA O. SINE O. TR I O. SQ U O. LO GIC O. ZO UT/ PW R NG O. PO L SPA RE, 0 -1 0 V PW , 0 -1 0 V OF FSET, 0 -1 0 V AMPL ITU DE , 0 -1 0 V CO NN 2 GA TE C CO NN 3 EX T T RIG B NO C NC NO NC C SW VF AU X GN D AMP OU T +2 4 V GN D PG H V+ SY NC CO NN 1 TR IG +1 5 V NSY GA TE PG G ND LA N VP RF VS PAR E BD 2 PC B1 0 4 E K EY PAD A K +2 4 V, N O OLO TEM P OV AU X CH AN GE S RE QU IR ED ON PC B 255 D (P RF LI M) 1) INS TALL C 9 = 18 0pF POLY (50 k Hz @ 80% DU TY) A A AVOZ-H1-B-P Pri nte d Re vis i on 25-Jan-2016 Z:\mjcfiles\circuits\avoz\avoz.Ddb - AVOZ-H1-B\H1 WIRING V1.sch 1 2 3 4 5 6 1B 42 PERFORMANCE CHECK SHEET