Operation Manual Dehumidifier Mundoclima Orthos Series

   EMBED


Share

Transcript

OPERATION MANUAL DEHUMIDIFIER MODEL : ORTOS110 / ORTOS110 SC ORTOS140 / ORTOS140 SC ORTOS190 / ORTOS190 SC Please read this operation manual before using the dehumidifier CONTENTS Safety Instruction 3 Attention during Usage 4-5 Principle of dehumiditifier 6 Specification 6 Descriptions of Parts 7 Panel Controll 8 Exploded Views 9 Installation note 10 Remote Controller 11-12 Operation Guide 13 AUTO Operation Mode 14 Air Direction Adjustment 15 Timer Operations 16 Defrost system 17 Assistant heater 17 Water drainage system 17 Error codes 18 Wiring diagram 18 Maintenance 19-21 Trouble Shooting 22 2 Safety Instruction Please read the following Safety Instructions carefully prior to use. The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use. Installation WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. lnstallation in a following place. inadequate place may cause accidents. Do not install in the the unit CAUTION Do not install in the place where there is any possibility of inflammable gas leakage around the unit. Connect the earth cable. Do not get exposed to vapor or oil steam. earthing PROHIBITION PROHIBITION WARNING When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop. OFF Use with STRICT ENFORCEMENT 3 an exclusive power a circuit breaker source Attention during Usage WA R N I N G Ensure the power plug is secure If the plug is not secure, it may cause a electric shock, over-heat- Never pull out the power plug during operation. otherwise, it may cause a elec- ing or a fire. tric shock or a fire due to over heating. Do not use the same socket with other electric appliances or Do not operate when the hands are wet. use an extension cord. otherwise it may cause a electric shock or a fire due to over- due to danger of a electric shock. Never u se d amaged e lectric wires or unspecified electric wires. otherwise it may cause a electric shock or a fire. Do not insert a rod or other objects into the inlet or outlet vents. otherwise, it may cause a electric shock or a fire. heating. Do not out a expose yourself single directional airflow for a long period to avoid harming to your health. to a In case of abnormal condition (burning smell etc.),pull out the power plug to stop the dehumidifier from running, or disconnect the power supply by means of a electric current protector. If the abnormal condition persists, it may cause a electric shock or a fire due to over-heating. Please consult the dealer of service centre as soon as possible to arrange for a repair. 4 Do not attempt to carry repair. Improper repairs may cause a electric shock or a fire. You should contact the dealer of service cen- tre to arrange for a repair. Attention during Usage Do not hold the electric wire to pull out the power plug. Pulling of the electric wire may cause over-heating of the electric wire of a fire. If the air-conditioner is not in use for a long time, it is necessary to pull out the power plug. Switch off the power supply while cleaning d e - humidifier. the Excessive dust on the power plug may also cause over-heating or a fire. Please take care not to damage Do not place a heater in front of the dehumidifier. Do not pour water onto the internal fan which is rotating at a high speed. PROHIBITION Do not use the dehumidifier for other purposes. Do not use it for keeping precision instruments, food, plants and ar- If internal combustion of the heater is not complete, it may give out tistic items. poisonous carbon monoxide. This may affect the dehumidifier for cleaning. Due to danger of electric shocks. quality of the food. PROHIBITION PROHIBITION PROHIBITION 5 the Principle of dehumidifier CONDENSER EVAPORATOR COMPRESSOR WARM DRY AIR OUTLET COLD DRY AIR AMBIENT AIR INLET COLD DRY AIR FAN CONDENSE WATER CAPILLARY WATER TANK WATER DRAIN OUT WATER PUMP The dehumidifier use the refrigeration circuit to change the damp air warm dry air. When the damp air passes the condenser, the air water will be condensed and the air will become dry. The Specification Of Dehumidifier (R410a) Model ORTOS110 ORTOS140 ORTOS190 4.5 6 8 2300 3200 4300 1300 1650 2300 850 850 1150 900 1250 1750 230V/50Hz/1Ph 230V/50Hz/1Ph 230V/50Hz/1Ph 5.8 7.0 10.5 2000 2000 2000 Rotary Rotary Rotary Capacity(L/hr) Heating Power Air capacity(W) consumption(W) flow(m3/hr) Refrigerant(g) Power supply Current(A) Aux electric Compressor heater(W)(option) type Compressor(brand Water name) Daikin pump or sanyo Daikin or sanyo Daikin or sanyo Yes Yes Yes 100-150 150-200 200-250 Noise(dB(A)) 47 48 53 Drain 500 500 500 Packing dimension(mm)(WxHxD) 535x1790x470 535x1790x470 535x1790x520 Unit 485x1725x320 485x1725x320 485x1725x370 Applicable area(㎡) pipe(mm) dimension(mm)(WxHxD) Weight(net/gross)(kg) 72/82 Test condition: Dry ball 77/87 temperature 6 30℃. Relative 84/94 humidity of 80RH%. Descriptions of Parts 1 2 3 4 5 6 7 8 9 Air Outlet Control Panel Air filter(inside) Air Inlet Humidity sensor Indoor temperature sensor Water drainage system Four way valve Compressor Electrical control Box 1 C % A TIM E R HEATER SWIN G SWIN G + SPEED _ FAN MODE ON/O F F 2 10 3 4 8 9 5 7 7 6 Exploded Views 9 10 8 11 6 7 5 12 33 4 15 13 16 1 14 35 36 24 22 17 21 23 20 18 19 25 31 26 2 3 28 34 32 27 37 38 30 29 19 Plastic-base 38 Power Cord 18 Water pan 2 37 Defrost temperature sensor 17 Water pan 1 36 Humidity sensor 16 Evaporator 35 Filling gas valve 15 Plastic foam air duct 34 Stepper motor 14 Fan motor fixer 33 Flow detector 13 Fan motor 32 Electrical Box 12 Cover 31 Transformer 11 Cross flow fan 30 Circuit Board 10 Right panel 29 Motor Capacitor 9 Auxiliary electric heater 28 Public Terminal 8 Upper fixing board 27 Compressor Capacitor 7 Condenser 26 Terminal 6 Top cover 25 Truckle 5 Left panel 24 Drain pipe 4 Back board 23 Auto water drainage system 3 Control panel 22 Four Way Valve /Copper Pipe 2 Front Panel 2 21 Compressor 1 Front Panel 1 20 Chassis 8 Installation note To ensure dehumidifier is steady during running, it prepared top dead plate and root support foot, the installation and use as following fig. 1 and 2. fig. 1 Please note that root support foot can draw out or draw back, it is convenient for user moving dehumidifier to other place by root wheel. fig. 2 Function of the needle valve When the heat pump need to measure the pressure of the current system or to filling refrigerant, the operator can use this low-pressure needle and make the appropriate maintenance work! needle valve 9 Panel Control Signal Receiver C A Display % TIMER HEATER SWING _ + SWING FAN SPEED MODE Button ON/OFF Button ON / OFF Press the button to start operation, Mode is selected in a sequence: MODE press the button again to stop operation. Automatic ; Dehumidifying ; Fan ; Heating. FAN SPEED Select the fan speed. Each time press the +/ button; fan speed is selected in a sequence: _ One press of the “ + “ button to raise o the temperature by 1 C; One press of LOW , MID , HIGH. the “ - ” button to lower the temperature o by 1 C. SWING HEATER Set the swing or stop of Left-Right Airflow Press once to switch on assistant heater; 1 5 9 7 2 A 6 Auto operation mode 6 2 Fan operation mode 7 3 Heating operation mode 8 4 5 Set the TIMER ON / OFF. 4 C % A 1 vane. TIMER Press again to switch off assistant heater. Display Set the swing or stop of Up-Down Airflow SWING vane. Dehumidifying operation mode 9 8 3 Displays when turns to CLOCK status C Displays when turns to TEMPERATURE status % Displays when turns to HUMIDITY status CLOCK or TEMPERATURE or HUMIDITY display Assistant heater display 10 Remote Controller Signal Emitter : Sending out remote control signal to the air-conditioner Temperature Adjustment Button : Adjust temperature settings Press once to set temperature 1 degree higher. Press once to set temperature 1 degree lower. Remote Controller Display Panel : Display settings DRY TEMP Mode Button : Select Automatic, Heating, O On/Off Button : Press once to start Air-conditioner running; Press again to stop running. C De-humidifying, Fan modes AUTO FAN SW I NG ON / OFF FAN Button : Air flow setting MODE Timer Cancel Button : Cancel Timer-On and Timer-Off settings OFF Timer Off Button : Set Timer-off hour. ON Timer On Button : Set Timer-on hour. TIM E R FA N CANCEL CONFIRM SWIN G SLEEP Timer Confirm Button : Send Timer-on or Timer-off data to the air-conditioner HEATER Manual Assistant Heater Button Press once to switch on assistant heater; Press again to switch off assistant heater.( option ) Air Direction Button : Set air louver swinging or stationary 11 : Remote Controller Emission Indicator : This symbol flashes once when the Remote Controller emits signals to the Dehumidifier. Mode Display : Press "Mode" button to display the current working mode. Automatic, Heating, Dehumidifying, Fan modes Temperature Display : It displays the current set temperature which may be adjusted by Temperature Adjustment Button or o within the range of 18 ~30 C. In Au- tomatic Mode, temperature is not dis- played but " Standard " (standard) o temperature + 2 C) or " Standard " o (standard -2 C) temperature is displayed. O C Timer Display : It displays the time setting for TimerOn or Timer-Off in the range of 1~12 hours. FAN Displa y : It displays the current amount of air flow. FAN Automatic Display on Remote Controller Air Direction Display : When "Swing" is in display, the updown louver of the air-conditioner is swinging. When the d i s p l a y disappears, the updown louver stops swinging. AUTO FAN Low FAN Mid FAN High FAN NOTE: All Displays on the diagram are listed out for demonstration. During operation, only the relevant Display will appear on the Remote Controller. 12 Operation Guide Proper settings of Heating, Dehumidifying and Fan modes Mode Selection ( 1 ) Press "Mode" button to select the required working mode, which is changed in the following sequence when pressed once: Automatic Dehumidifying Fan Heating DRY TEMP NOTE: Heating mode is available only on cooling-heating type air conditioner. Automatic operation will be explained in detail on next page. C AUTO Air Flow Selection ( 2 ) FAN SWING Press "FAN" button to select the required amount of air flow, which is changed in the following sequence when pressed once : Automatic 3 O Low Mid MODE 1 High FA N NOTE: When Automatic FAN is selected, the air-conditioner will automatically select the suitable amount of air flow according to room temperature. When Dehumidifying is selected, the amount of air flow is set by the machine and fan setting is not functional. Temperature Setting Selection ( 3 ) Press "Temperature Adjustment Button " to set temperature 1 degree higher. Press "Temperature Adjustment Button " to set temperature 1 degree lower. Hold down the Button to increase of decrease the temperature settings progressively. NOTE: o o Range of adjustable temperature settings : 16 C ~ 31 C. Starting Operation ( 4 ) Press "On/Off" button, and when the unit receives the signal, it gives out two "beep" tones, the operation light is on and the dehumidi- fier starts operation. NOTE: If it is desired to run the machine at the same settings for mode, air flow and temperature as the last operation, skip Steps 1~3 and start the machine directly. If the interval is shorter than 3 minutes from last shut down to the present switch-on, the compressor only re-starts after 3 minutes to protect the system. After switching on and if the mode is changed, the system may delay for 3 minutes before starting operation. When heating mode is selected, the internal fan will delay operation for a while when the machine is switched on to prevent cool air circulation at the beginning. After switching on, air flow amount and temperature may be separately adjusted as desired. 13 2 ON / OFF OFF ON TIMER CANCEL SWING SLEEP CONFIRM HEAT ER 4 AUTO Operation Mode Automatic operation Mode Mode Selection (1) Press "Mode" button to select Automatic Operation mode. AUTO Fan Selection (2) TEMP Press "FAN" button to select the required amount of air flow, which is changed in the following sequence when pressed once : Automatic Low Mid AUTO High FAN SWING NOTE: When Automatic FAN is selected, the unit will automatically select the suitable amount of air flow according to room temperature. MODE OFF 1 Starting Operation (3) 3 ON TIMER FA N 2 Press " On/Off " button, and when the unit receives the signal, it gives out two " beep " tones, the operation light is on and the dehumidifier starts operation is automatic mode. ON / OFF SWING CANCEL CONFIRM S LEE P HEAT ER NOTE: In automatic mode, the dehumidifier automatically selects "Dehumidifying” , "Heating" modes depending on room temperature and the humidity, with details as the follow-ing table: Temperature Model o < 23 C or o > 28 C o o 23 C ~ 28 C o o < 23 C or > 28 C humidity: > 80% Dehumidify Heating humidity: < 80% Working Working Not Working Not Working Not Working Working Adjustment in Automatic Mode Feeling Unsuitable fan speed Button FAN 14 Operation Press once to change the air flow progressively until the suitable air flow is selected. Air Direction Adjustment Up-Down Air Direction Adjustment C % A TIMER SWING HEATER Airflow horizontally _ + SWING FAN SPEED MODE ON/OFF Airflow upward Airflow downward NOTE: To stop the up-down air louver in a desired position, set the louver to automatic swinging and when it reaches the desired position, stop the louver from swinging. It is necessary to adjust the louver angle by means of the remote controller, Setting of the louver with the hand may affect its normal operation, in which event, switch off the unit temporarily and re-start operation. To get the best effect, the up-down air flow is usually set in the following manner : Dehumidifying - Horizontal air direction or upward air direction. Heating Downward air direction. Changing Left-Right Air Direction COOL C % A TIMER HEATER SWING SWING + TEMP O OR _ AUTO FAN SPEED MODE ON/OFF C FAN SWING MODE ON / OFF OFF ON TIMER FA N CANCEL SWING LEEP NOTE: Don’t move the Left-Right vane directly. 15 S CONFIRM HEATER Timer Operations Timer Switch On 1. Press "Timer On" button to set time for timer-on switching. Press the button once to change the time interval of 1 hour in a cyclic manner of 6, 7, 8 ...12 ..1, 2..5,6 (The display is showing the previous time as the starting time of the present setting) If the button is held down, the time interval will increase progressively by 1 hour unit. 2. Point the remote controller towards the receiver on the unit, press "Timer Confirm" button send the timer setting the deto to humidifier. Then the timer light on the unit lights up, indicating that the unit is in the timer mode. When it reaches the switch-on time, the dehumidifier will operate in the pre-set modes. NOTE: Before timer operation, please set the operation mode, temperature, air flow etc. on the remote controller, With timer being set to switch-on mode. the Dehumidifier will operate according to the last setting. Usually, timer-on setting is made while the dehumidifier is not in operation. If timer-on is set while the dehumidifier is running, then the unit will shut down immediately and re-start at the pre-set time. If the "On-Off" button is pressed while the unit is under timer-on setting, then the unit will start immediately, the timer setting is cancelled and the timer light will be off. DRY TEMP O HR AUTO 1. Press "Timer Off" button to set time for timer-off switching. Press the button once to change the time interval of 1 hour in a cyclic manner of 6, 7, 8 ...12 ..1, 2..5,6 (The display is showing the previous time as the starting time of the present setting) If the button is held down, the time interval will increase progressively by 1 hour unit. 2. Press "Timer Confirm" button to send the timer setting to the Dehumidifier. Then the timer light on the unit lights up, indicating that the unit is in the timer mode. When it reaches the switch-off time, the air-conditioner will automatically shut down. NOTE: Timer-Off can only be set when the Dehumidifier is running. Timer-On and Timer-Off cannot be set at the same time. Timer display on the remote controller : While time passes, the display shows the remaining time. If the "On-Off" button is pressed while the unit is under timer-off setting, then the unit will shut down immediately, the timer setting is cancelled and the timer light will be off. Timer Cancellation Press "Timer-Cancel" button to cancel the timer-on or timer-off settings. 16 AFT ON FAN SWING MODE FA N SWING Timer Switch Off C ON / OFF OFF ON TIMER CANCEL CONFIRM SLEEP HEAT ER 1 2 Defrost system Sequences of the defrosting: 1- Start The defrosting is engaged if the following conditions are at the same time fulfiled: - the compressor and the fan motor run without stopping; o - the defrosting sensor temperature lower than 3 C , and the duration of time more than 45 minutes; o - the defrosting sensor temperature goes down to -7 C. 2- After 15 seconds, the 4 way valve shifts. 3- Five seconds after its stop, the compressor starts alone ; And the accumulated freeze on the gills becomes melting, what is generally with a steam cloud . 4- Stop: The defrosting stops if one of the following conditions is fulfiled: - the defrosting operates 20 seconds and the detected temperature by the o defrost sensor goes up to 12 C; - the compressor had run totally 8 minutes. 5- The compressor runs. 6- After 15 seconds the 4 way valve shifts 7- Five seconds after its stop the compressor and the fan start for restarting in heating mode. 8- The running light is blinking during defrosting. Assistant heater ( Option ) 1〉Electric al heater doe s work only if i n heating temperature or dehumidify mode; 2〉w hen compressor is running, press button ‘heater’, the dis play board’s ‘ ’ l ights, electrical heater s tarts; press button‘heater’ again, the dis pl ay board’s ‘ ’turn off, electrica l heater stops . When get to desi re temperature, both compressor and electrical heater stop at the same ti me ; 3〉When compress or is not running, press button ‘heater’ , the disp lay board’s ‘ ’ fl ashes, the heater i s standby at the moment, it works after compressor starts. Water drainage system During the dehumidify mode, the condenser water will be drained into the internal water tank .When the water reaches the certain level, the water drain pump will work. If the water can be drained out in 8 mins, the dehumidifier will keep working. If not, the compressor and the motor will stop working. Mean while an error message “ E4 “ will appear in the control panel to inform you to empty the water. In this instance, you should cut the power off, and then restart the dehumidifier ,and the operation will continue . 17 Error Codes E1 : Room temperature sensor error; E2 : Defrost temperature sensor error; E3 : Humidity sensor error; E4 : Drain error; TIMER SWING HEATER SWING _ + FAN SPEED MODE ON/OFF Wiring diagram With electrical assistant heater WIRING DIAGRAM FAN MOTOR COMPRESSOR Y/G G STEP MOTOR MS MS 2 PUMP RED WHITE S CM R Synchronization MOTOR C1 Y/G FM C G C 5 5 AC-N2 RY1 RY2 AC-N HF MF LF AC-N LEFT RY9 TEMPERATURE CONTROLLER PCB NO L RY6 WATER LEVEL SWITCH BLACK BLACK WHITE ROOM TEMPERATURE SENSOR DEFROST BLACK N Y/G WHITE CNA 3 CNB G TEMPERATURE SENSOR HUMIDITY TEMPERATURE SENSOR TERMINAL 11 ASSISTANT HEATER RED WHIT PUBLIC TERMINAL NO COM DISPLAY RECEIVE BOARD CN-DISP Without electrical assistant heater WIRING DIAGRAM COMPRESSOR PUMP RED S C1 Y/G G R CM Y/G WHITE Synchronization STEP MOTOR MOTOR FAN MOTOR FM MS MS C2 G 5 C 5 AC-N2 HF MF LF ACN RY1 RY2 AC-N RY6 LEFT WATER LEVEL SWITCH ROOM TEMPERATURE SENSOR DEFROST NO L PCB BLACK N WHITE Y/G CNA CNB 3 G TERMINAL 11 TRANSFORMER DISPLAY RECEIVE CN-DISP BOARD 18 TEMPERATURE SENSOR HUMIDITY TEMPERATURE SENSOR Maintenance For smart use of the Dehumidifier: Setting of proper Do room temperature not inlet or block the air outlet Proper temperature Close doors and Use the timer Use the louvers effectively windows during operation If the be time, unit is used for turn off not a to long the power TMIEHRASWNGI + A C FAN % _ SPEMDON/F supply main switch. OFF 19 effectively Maintenance For smart use of the Dehumidifier: WARNING Before maintenance,be sure to turn off the system Remote Controller not Wipe the air conditioner by using a soft and dry cloth.For serious stains,use a neutral detergent diluted with water.Wring the water out of the cloth before wiping.then wipe off the detergent completely. use the following for cleaning Hot water over 40 oC (104 oC ) may cause discoloring or deformation. Gasoline,benzine, thinner or cleanser may damage the coating of the unit. Air Filter the circuit breaker. Body Do not use water, wipe the controller with a dry cloth.Do not use glass cleaner or chemical cloth. Do and cleaning Press the clasp on the top of the grill and pull the grill out, and then the filter will be taken out along a gradient way. Clean the filter. Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade. Then, reinstall it onto the unit. 20 Once every two weeks Maintenance To keep your Dehumidifier in good condition after season: 1. Operate in FAN mode for about half a On a fine day, unit shall be started and operate FAN mode for about half a day until the inside of the unit becomes thoroughly dry. 2. day. in Turn off the power supply main switch. OFF 3. Cleaning the body. 4. Take out the batteries wireless remote controller. from the 21 Trouble shooting Before asking for service, check Phenomenon The system does restart immediately. the Cause following or check first. points When unit is stopped, it won't restart immediately until 3 minutes have elapsed to protect the system. not When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the dehumidifier. Noise is During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system.) heard: Normal Performance inspection During unit operation, a cracking noise may be heard. This noise is generated by the casing expanding or shrinking because of temperature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty. Multiple check Smells are generated. Does not work Inefficient at This is because the system circulates smells from the interior air such as the smell of furniture, cigarettes. all. Is power plug inserted? Is there a power failure? Is fuse blown out? Is the air filter dirty? Normally it should be cleaned every 15 days. Are there any obstacles before outlet? Is temperature set correctly? Are 22 there some doors or inlet and windows left open?