Preview only show first 10 pages with watermark. For full document please download

Operation Manual [pdf:215.4kb]

   EMBED


Share

Transcript

OPERATION MANUAL VDA-106A Video Distribution Amplifier 1st Edition - Rev.1 Precautions Important Safety Warnings [Power] Operate unit only on the specified supply voltage. Caution Disconnect power cord by connector only. Do not pull on cable portion. Stop Do not place or drop heavy or sharp-edged objects on power cord. A damaged cord can cause fire or electrical shock hazards. Regularly check power cord for excessive wear or damage to avoid possible fire / electrical hazards. [Grounding] Ensure unit is properly grounded at all times to prevent electrical shock hazard. Caution Hazard Do not ground the unit to gas lines, units, or fixtures of an explosive or dangerous nature. Ensure power cord is firmly plugged into AC outlet. Caution [Operation] Hazard Hazard Do not operate unit in hazardous or potentially explosive atmospheres. Doing so could result in fire, explosion, or other dangerous results. Do not allow liquids, metal pieces, or other foreign materials to enter the unit. Doing so could result in fire, other hazards, or unit malfunction. If foreign material does enter the unit, turn power off and disconnect power cord immediately. Remove material and contact authorized service representative if damage has occurred. [Transportation] Caution Handle with care to avoid shocks in transit. Shocks may cause malfunction. When you need to transport the unit, use the original packing materials or alternate adequate packing. [Circuitry Access] Do not remove covers, panels, casing, or access circuitry with power applied to the unit! Turn power off and disconnect power cord prior to removal. Internal servicing / adjustment of unit should only be performed by qualified personnel. Stop Do not touch any parts / circuitry with a high heat factor. Capacitors can retain enough electric charge to cause mild to serious shock, even after power is disconnected. Capacitors associated with the power supply are especially hazardous. Avoid contact with any capacitors. Hazard Unit should not be operated or stored with cover, panels, and / or casing removed. Operating unit with circuitry exposed could result in electric shock / fire hazards or unit malfunction. [Potential Hazards] Caution If abnormal smells or noises are noticed coming from the unit, turn power off immediately and disconnect power cord to avoid potentially hazardous conditions. If problems similar to above occur, contact authorized service representative before attempting to again operate unit. [Rack Mount Brackets, Ground Terminal, and Rubber Feet] Caution To rack mount or ground the unit, or to install rubber feet, do not use screws or materials other than those supplied. Otherwise, it may cause damage to the internal circuits or components of the unit. If you remove the rubber feet attached on the unit, do not reinsert the screws securing the rubber feet. [Consumables] Caution The consumables used in unit must be replaced periodically. For further details on which parts are consumables and when they should be replaced, refer to the specifications at the end of the Operation Manual. Since the service life of the consumables varies greatly depending on the environment in which they are used, they should be replaced at an early date. For details on replacing the consumables, contact your dealer. Upon Receipt Unpacking VDA-106A units and their accessories are fully inspected and adjusted prior to shipment. Operation can be performed immediately upon completing all required connections and operational settings. Check your received items against the packing lists below. ITEM VDA-106A AC Cord Rubber Feet Operation Manual QTY 1 REMARKS Select the voltage range between 200 V or 100 V AC before purchasing 1 1 set 1 Option ITEM Rack mount bracket set (type 1) Rack mount bracket set (type 2) QTY 1 set 1 set REMARKS For mounting single unit to an EIA 1RU rack space. For mounting two units to an EIA 1RU rack space. Check Check to ensure no damage has occurred during shipment. If damage has occurred, or items are missing, inform your supplier immediately. Rack Mounting The VDA-106A can be either single or dual mounted in EIA standard rack units. The rack mounting requires a purchase of one of the two available rack mount kits. When mounting single unit the single mount kit with one extended rack ear must be used. When mounting two units the dual mount kit with standard size rack ears must be used. Consult your FOR-A supplier to order either of these options. IMPORTANT To change the voltage range from 200 V to 100 V, or vice versa, after purchasing products, consult your FOR-A reseller. Components need to be replaced in the FOR-A factory. Table of Contents 1. Prior to Starting ........................................................................................................................ 1 1-1. Welcome ........................................................................................................................... 1 1-2. Features ............................................................................................................................ 1 1-3. About This Manual ............................................................................................................ 1 2. Panel Descriptions ................................................................................................................... 2 2-1. Front Panel ........................................................................................................................ 2 2-2. Rear Panel ........................................................................................................................ 2 3. Internal Settings ....................................................................................................................... 3 4. Connections ............................................................................................................................. 4 4-1. 6-Way Distribution ............................................................................................................. 4 4-2. Dual 3-Way Distribution ..................................................................................................... 5 5. Attaching Rubber Feet ............................................................................................................. 5 6. Specifications and Dimensions ................................................................................................. 6 6-1. Specifications .................................................................................................................... 6 6-2. External Dimensions ......................................................................................................... 6 1. Prior to Starting 1-1. Welcome Congratulations! By purchasing VDA-106A Video Distribution Amplifier you have entered the world of FOR-A and its many innovative products. Thank you for your patronage and we hope you will turn to FOR-A products again and again to satisfy your video and audio needs. FOR-A provides a wide range of products, from basic support units to complex system controllers, which have been increasingly joined by products for computer video based systems. Whatever your needs, talk to your FOR-A representative. We will do our best to be of continuing service to you. 1-2. Features The VDA-106A is a Video Distribution Amplifier that can provide 6 professional quality video outputs from one input. It can also configured to provide three outputs for each of two inputs.  Compact and lightweight design allows it to be used in almost anywhere  Two units can be fit in a 19 inch rack (using an optional rack mount kit.) 1-3. About This Manual This manual is intended to help the user easily operate this product and make full use of its functions during operations. Before connecting or operating your unit, read this operation manual thoroughly to ensure you understand the product. After reading, it is important to keep this manual in a safe place and available for reference. 1 2. Panel Descriptions 2-1. Front Panel 1 POWER ON VDA-106 VIDEO DISTRIBUTION AMPLIFIER OFF No. Name 1 Power switch Power indicator Description Switch used to turn unit power ON / OFF. Power indication will be lit when power switch is set to ON and power applied to the unit. 2-2. Rear Panel 1 2 3 4 AC100-117V 50/60Hz IN 75  1 2 VIDEO OUT (75 ) 3 4 5 6 VIDEO IN HIGH No. Name 1 VIDEO IN 2 75Ω / HIGH 3 VIDEO OUT 4 AC100-117V 50/60Hz IN 0.5A Description For analog composite video input connection. Connect video source devices such as video cameras. The bottom connector can be used to either accept video input or loop through the input in the top connector. * For 6-way distribution, input video to either one connector. * In the dual 3-way distribution, input in the top connector will be distributed to VIDEO OUT 1, 2 and 3 connectors, and the input in the bottom connector will be distributed to VIDEO OUT 4, 5 and 6 connectors. Toggle switch for impedance selection. Set to HIGH to use loop through connection. Set to 75Ω to use dual 3-way distribution. For analog composite video output connection. Each connector distributes video input in VIDEO IN connector(s). AC power connector with fuse. There are two fuses behind the cover. one is a spare. (Fuse: 0.5A) 2 3. Internal Settings IMPORTANT Adjustments and maintenance should be performed by qualified technical personnel familiar with FOR-A equipments. CAUTION Do not access internal boards or make connections with unit power ON. Always power OFF all connected units / disconnect power cords prior to accessing interior. To access the interior, open the top cover of the VDA-106A. 321 JP1 VR5 VR4 No. 1 Name JP1 (Distribution mode setting) Description Jumper pins for distribution mode selection. Default is set to 6-way distribution. Short pins 1-2 of JP1. 6-way distribution 321 (default) JP1 Short pins 2-3 of JP1. Dual 3-way distribution 2 VR4、VR5 (GAIN) 321 JP1 Video output level adjusters. Allows you to adjust video gain within approx. ±3dB. Use VR4 to adjust the level for all 6-way distribution VIDEO OUT connectors. (default) (Turn clockwise to ascend the level.) To adjust the level; Use VR4 for VIDEO OUT 1, 2 and 3. Dual 3-way distribution Use VR5 for VIDEO OUT 4, 5 and 6. (Turn clockwise to ascend the level.) 3 4. Connections 4-1. 6-Way Distribution If you are going to use multiple VDA-106A units to add more distribution channels, use loop through connection. If you are not using the loop though, set the impedance toggle switch to 75Ω. Video source (Video camera, etc.) AC100-117V 50/60Hz IN 75  1 2 VIDEO OUT (75 ) 3 4 5 6 VIDEO IN HIGH 0.5A VTR, monitor, signal testing equipment, etc. To connect units using the loop through, set the impedance toggle switch to HIGH. Video source (Video camera, etc.) AC100-117V 50/60Hz IN 75  1 2 VIDEO OUT (75 ) 3 4 5 6 VIDEO IN HIGH 0.5A VTR, monitor, signal testing equipment, etc. VTR, monitor, signal testing equipment, etc. 4 4-2. Dual 3-Way Distribution To use the VDA-106A in dual 3-way distribution mode, set the impedance toggle switch to 75Ω. Video source 1 (Video camera, etc.) Distribution of video source 1 75Ω OUT AC100-117V 50/60Hz IN 75  1 2 VIDEO OUT (75 ) 3 4 5 6 VIDEO IN HIGH 0.5A 75Ω OUT Video source 2 (Video camera, etc.) Distribution of video source 2 3-way distribution 5. Attaching Rubber Feet Peel off the backing of the self adhesive rubber foot and stick on the bottom of the VDA-106A one by one as shown below, if necessary. Bottom side of VDA-106A 5 6. Specifications and Dimensions 6-1. Specifications Video Input Analog composite: 1.0 Vp-p 75Ω or loop-through, BNC x 1 Video Output Analog composite: 1.0 Vp-p 75Ω BNC x 6 Frequency Response 60 Hz to 10 MHz, ±0.5 dB, roll off above 12 MHz Overshoot 16 kHz, 250 kHz, Less than 1% DG/DP 0.3% / 0.3º (APL 10% - 90%) Temperature 0ºC to 40ºC Humidity 30% to 90% (no condensation) Power 100 VAC to 117 VAC or 220 VAC to 240 VAC ±10%, 50/60 Hz *1 Consumption 5 VA Dimensions 215 (W) x 44 (H) x 100 (D) mm Weight 0.9 kg *1: Please specify the power supply voltage when ordering. To change the voltage range from 200 V to 100 V, or vice versa, after purchasing products, consult your FOR-A reseller. Components need to be replaced in the FOR-A factory. 6-2. External Dimensions (All dimensions in mm.) HIGH 4 5 1 2 VIDEO OUT (75  ) VIDEO IN 6 0.5A 3 75  100 AC100-117V 50/60Hz IN t2 15 2x2-M4 215 12 20 12 OPTIONAL ACCESSORIES 6 2x2-6.4x12 POWER VIDEO DISTRIBUTION AMPLIFIER 32 44 ON VDA-106 6 OFF 462 ONE UNIT 480 POWER POWER ON VIDEO DISTRIBUTION AMPLIFIER OFF VDA-106 ON VIDEO DISTRIBUTION AMPLIFIER OFF TWO UNITS 6 VDA-106 Warning This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. 04/16/2012 Printed in Japan FOR-A COMPANY LIMITED Head Office Overseas Division Japan Branch Offices R&D/Production 3-8-1 Ebisu, Shibuya-ku, Tokyo 150-0013, Japan Phone: +81(0)3-3446-3936, Fax: +81(0)3-3446-1470 Osaka/Okinawa/Fukuoka/Hiroshima/Nagoya/Sendai/Sapporo Sakura Center/Sapporo Center FOR-A America Corporate Office 11155 Knott Ave., Suite G&H, Cypress, CA 90630, USA Phone: +1-714-894-3311 Fax: +1-714-894-5399 FOR-A America East Coast Office 2 Executive Drive, Suite 670, Fort Lee Executive Park, Fort Lee, NJ 07024, USA Phone: +1-201-944-1120 Fax : +1-201-944-1132 FOR-A America Distribution & Service Center 2400 N.E. Waldo Road, Gainesville, FL 32609, USA Phone: +1-352-371-1505 Fax: +1-352-378-5320 FOR-A Corporation of Canada 346A Queen Street West, Toronto, Ontario M5V 2A2, Canada Phone: +1-416-977-0343 Fax: +1-416-977-0657 FOR-A Latin America & the Caribbean 5200 Blue Lagoon Drive, Suite 760, Miami, FL 33126, USA Phone: +1-305-931-1700 Fax: +1-305-264-7890 FOR-A UK Limited UNIT C71, Barwell Business Park, Leatherhead Road, Chessington Surrey, KT9 2NY, UK Phone: +44(0)20-8391-7979 Fax: +44(0)20-8391-7978 FOR-A Italia S.r.l. Via Volturno 37, 20047 Brugherio MB, Italy Phone: +39-039-881-086/103 Fax: +39-039-878-140 FOR-A Corporation of Korea 1007, 57-5,Yangsan-ro,Yeongdeungpo-gu, Seoul 150-103, Korea Phone: +82(0)2-2637-0761 Fax: +82(0)2-2637-0760 FOR-A China Limited 708B Huateng Bldg., No. 302, 3 District, Jinsong, Chaoyang, Beijing 100021, China Phone: +86(0)10-8721-6023 Fax: +86(0)10-8721-6033 FOR-A Middle East-Africa Office Jebel Ali Free Zone, LOB-16, Office 619, P. O. Box: 261914 Dubai, UAE Phone: +971 4 887 6712 Fax: +971 4 887 6713 *The contents of this manual are subject to change without notice.