REMKO RKL 290 / RKL 350 Portable Air Conditioner
Operation Technology Spare Parts
Edition GB – R04
REMKO – powerful like a bear.
Operating Instructions Read these instructions carefully before setting up/operating the unit!! Our guarantee becomes null and void if the unit is used, set up or maintained improperly, or if modifications are made to the supplied unit without our prior consent. Subject to alterations!
Portable Air Conditioner REMKO RKL 290 / REMKO RKL 350
Contents
Page
Contents
Page
Safety Instructions
4
Wiring Diagram
10
Transport and Packaging
4
Troubleshooting
11
Description of Device
5
Technical Data
12
Operation
5
Customer Service and Guarantee
12
Prior to Initial Operation
8
Environment and Recycling
14
Initial Operation
9
Exploded View
12
Shutting Down the Unit
9
Spare Part List
13
Installation of the Wall Lead-through
15
Maintenance and Service
10
Cleaning the Filter
10
*
Always keep these operating instructions near or on the unit.
*
Safety Instructions Extensive tests have been conducted on the material, functionality and quality of the REMKO portable air conditioner to ensure that it is a high-performance unit with a long service life. Hazards may nevertheless arise if the unit is used by persons not familiar with its operation or if the unit is not used for its intended purpose. Please make sure to follow these instructions:
Do not transport the unit during operation. Do not place the unit on its side. Protect all electrical cables from being damaged, for example, by animals. Make sure that all extension cables are suitable in terms of capacity, length and intended use. Do not lay any lines under carpets.
The unit is not suitable for outdoor operation.
Never operate the unit without the air filter!
Do not set up or operate the unit in rooms susceptible to explosions.
Never aim the air current directly at people!
Ensure that the unit is set up at a safe distance from flammable materials. Do not set up or operate the unit if the atmosphere is contaminated by oil, sulphur or salt.
Never open the unit housing! This may cause an electrical shock. Work on the cooling system and on the electrical equipment may only be performed by an authorised service centre.
Do not set the unit up near curtains or drapes. Minimum distance of 50 cm. Ensure that the air intake and outlet openings are always clear of foreign objects. Ensure that the air conditioner is securely placed on a level surface. The unit may only be operated in an upright position. Do not insert any foreign objects into the air intake or outlet openings. Do not place any heavy or warm objects on top of the unit. Do not expose the unit to direct streams of water. Operate the unit only within its permissible operating ranges. Pay attention to the surrounding temperatures. This unit may only be connected to a correctly installed, grounded and fused plug socket. 230V / 50Hz, fuse 10A. When unplugging the unit, do not pull the power cable too forcefully or bend it too much. This may result in damage to the cable! Do not move the unit while in operation. Wait at least 5 minutes before starting the unit after it has been moved. This protects the unit from damage. Switch the unit off by pressing the “Power” button. Do not switch the unit off by unplugging the power cord.
4
*
Operation/handling which does not comply with these instructions is prohibited! In cases of non-compliance, we assume no liability and the guarantee becomes null and void.
Transport and Packaging All units are subject to continuous quality control and are carefully packaged before being sent. The device is shipped in a stable transport box made of cardboard. Please examine the unit when it is delivered. Make note of any damage or missing parts on the shipping bill and inform the shipping company and your contract partner. No liability is assumed for subsequent claims. Please observe the following for transport: Before transporting the unit, switch it off on the control panel and unplug the power cable. The unit may only be transported in an upright position. The unit is equipped with wheels and two handles to makes transport easier. Excess condensation is collected in the internal tank of the unit. We recommend removing this water prior to transport via the drain at the back of the unit.
Description of Device The RKL 290-350 air conditioner comes with an infrared remote control and an air outlet hose with a flat nozzle. Air directing plate fins
The unit has been designed for automatic, universal, smooth air dehumidification. Its compact dimensions make it easy to transport and set up in all rooms.
Air outlet
The unit meets the basic safety and health requirements found in the relevant EU regulations. It is safe and easy to operate.
Control panel
Functional principle
IR receiver Recessed grip
The portable air conditioner cools the air in the room by extracting the heat from it. The heat absorbed is expelled to the outside via the exhaust hose and the cooled air is resupplied to the room where the unit is in operation via a fan. Condensation that accumulates drips from the evaporator onto the hot condenser where it condenses and is then transported via the air outlet hose to the outside. Excess condensation drips from the condenser into a collection tray and is resupplied to the condenser by means of a rotating wheel with blades, where it evaporates and is then expelled with the outgoing air current.
Transport wheels Air filter circulation
Cool circulating air in the room
Evaporator Circulation intake from the room
Air intake circulation Air filter exhaust
Fan for circulation
Air outlet hose
Fan for outgoing air
Air outlet exhaust
Compressor
Warm air expelled to the outside Condenser Expelled air intake from the room Refrigerant cycle
Condensation drain with plug
The environmentally-friendly refrigerant, R 407C, transports the absorbed heat within the closed-loop refrigerant cycle.
Cable holder Air intake exhaust
The unit’s primary function is to air-condition rooms. It also filters and dehumidifies the air, thus creating a comfortable climate in the room.
Operation Prior to putting the unit into operation, ensure that all safety instructions have been observed.
In “Fan” mode, the unit can also be used to circulate air with no cooling effect.
Please note that the unit operates most efficiently and most comfortably when put into operation before the hottest part of the day, e.g. the morning.
The units operates fully-automatically and offers a range of other options thanks to its microprocessor control. For example, it can be automatically switched off and on at a preset time via the timer function.
The selected target temperature should be 4 to 7°C below the outside temperature. It should never be lower because the room temperature would feel too cold when coming from a non-air-conditioned room and people may catch cold.
The unit is comfortably operated via the control panel on the indoor unit or via the infrared remote control that comes with it.
The selected target temperature does not affect the performance of the unit! This means that when temperatures in the room are high, it is not practical to adjust the unit to the lowest possible target temperature.
5
Control Panel 12
14
3
10
11
5
9
8
2
7
1
5 “TIMER” button
The unit is switched on or off with button 1. 2 “MODE” button Button 2 is used to switch between “Cooling” mode and “Ventilation” mode. Each time the button is pressed, the speed of the fan changes. The LEDs of display 8 indicate the selected speed. In “Cooling” mode, the unit cools the room to a set value as long as the LED 7 “COMP ON” is lit up. The temperature can be set in a range between 18 and 30°C. The fan speed can be freely selected as follows. Adjusted fan sped: LED “AUTO” Highest fan speed: LED “HI” Medium fan speed : LED “MED” Lowest fan speed: LED “LO” The “AUTO” setting is used to automatically adjust the fan speed to the desired cooling capacity. The greater the difference b e tween the set and current room temperature, the higher the fan speed. 3 “AUTO SWING” button This button is used to set how the air that is discharged from the unit is distributed. Press button once =continuous swing function Press button twice =locked swing function Press button third =continuous swing function 4 ▲ / ▼ “THERMO CONTROL” button This button is used to set the desired target temperature in “Cooling” mode. If the Up/Down button 4 is pressed, the adjusted target temperature is shown on the display. The target temperature can be set in 1°C increments between 18 and 30°C.
6
4
6
1 “I / 0” button
Upper button Lower button
13
= =
higher target temperature. lower target temperature.
This button is used to automatically activate the unit to switch on and off. When the unit is off, the Timer On function is programmed in one hour increments up to 24 hours via the “SET” button. The LED 10 displays that this function has been activated. When the unit is on, the Timer Off function is programmed in one hour increments up to 24 hours via the “SET” button. The LED 11 displays that this function has been activated. 6 “RESET” button The programmed timer can be deactivated by pressing the button 6 “RESET”. 7 “COMP. ON” button In cooling mode, the unit operates according to the programmed target temperature. If the target temperature has been reached, the compressor that creates the cooling capacity switches off. However, the circulation fan continues to operate. The LED 7 lights up while the compressor is in operation. 8 Cooling mode: “AUTO, HI, MED, LO” LED See also point 2. 9 Ventilation mode: “FAN” LED In ventilation mode, the air in the room is circulated. The unit does not cool. The fan speed cannot be selected and is automatically set to “MED”. The temperature can be changed, however, this does not change the operating mode. 10 “TIMING ON” LED This LED indicates whether the timer has been activated to switch the unit on. 11 “TIMING OFF” LED This LED indicates whether the timer has been activated to switch the unit off.
12 “DRAIN WATER” display This light indicates that the floating switch of the internal tank has switched off unit operation. The internal tank does not become full during normal operation because the exhaust fan transports the accumulated and evaporated condensation to the outside via the exhaust hose. In conditions with very highs levels of humidity, the moisture cannot be completely expelled and the unit switches off. To resume unit operation after it has automatically been switched off due to a malfunction, proceed as follows:
Infrared Remote Control Functions All settings can also be made using an infrared remote control. A description of the button functions can be found in the “Control Panel” section. The remote control’s range is approx. 5 meters. Two 1.5 V AAA batteries (included in the scope of the remote control delivery) power the remote control.
1. Switch the unit off by pressing the “On/Off” button and unplug it from the power supply.
2
2. Place a suitable container under the condensation drain of the internal tank. The condensation drain is located at the bottom middle at the back of the unit.
1
THERMO CONTROL
5
MODE
set
3
POWER on / off
TIMER reset
3. Pull the plug from the condensation drain and collect the water that drains out.
4
AUTO SWING
4. Then replace the plug.
*
Keep in mind that if there is no plug or it is inserted incorrectly, water may leak out after the unit has resumed operation.
13 Display The programmed room temperature is shown on the display.
1 2 3 4 5
“ON/OFF” button “MODE” button “TIMER” button “AUTO SWING” button ▲ / ▼ “THERMO CONTROL” buttons
The current temperature value is increased or decreased by pressing the Up/Down buttons 3 and 4. If the timer button 5 is pressed, the display switches to show the remaining hours until the unit is switched on or off.
General Information The infrared remote control must be protected from moisture. When the unit is switched on, each change in the settings is automatically transferred to the air conditioner. A beep indicates that the data has been properly received.
If after 5 seconds, no buttons are pushed, the target temperate appears on the display again. 14 Infrared remote control receiver
The transmitter of the infrared remote control must generally transfer changes to settings in the direction of the air conditioner.
If the unit is operated using the infrared remote control, the impulses are received via the receiver.
It is only possible for data to be properly transmitted if there are no objects located between the transmitter and the receiver unit such as doors, drapes, blinds, etc.
Infrared Remote Control Inserting the batteries into the remote control Prior to initial operation, the batteries supplied with the unit (2 type AAA batteries) must be inserted into the remote control. 1. Slide off the cover of the battery slot on the back of the remote control. 2. Place the batteries in the slot making sure that the polarity is correct. Use the labelling in the slot. 3. Close the cover.
Never use new and old batteries at the same time! We recommend removing the batteries from the remote control if the unit is taken out of operation for a longer period of time.
*
Remove dead batteries and immediately replace them with new batteries that meet quality standards because otherwise they may leak.
7
Prior to Initial Operation The unit is set up in the desired location with the air outlet side facing the room. Follow the safety instructions when setting up the unit.
*
There must be a minimum of 20 cm between the back of the unit and the wall.
5 MIN.
Expelling the warm air During cooling mode, the unit generates warm air. This air must be expelled from the room to retain the cooling effect. It is therefore necessary to insert the supplied exhaust hose into the air outlet opening at the back of the unit. Make sure that the deflector piece from the top slides down into the notches on the side until it clicks into place.
After unpacking the unit, place it on its transport wheels and let it stand for a minimum of 5 min. before switching it on. Place the unit securely on a level and firm surface. An uneven surface can cause vibrations and disruptive noises. Before plugging in the power cord, make sure that the required current is available! 230V / 1~, N, PE / 50 Hz. If extension cords are necessary, make absolutely sure that they are sufficiently thick.
To ensure that the unit operates effectively, do not place the flexible exhaust hose supplied at sharp angles and make sure there are no kinks. You may not extend the exhaust hose. The air expelled from the unit contains a certain amount of moisture. We therefore recommend expelling the air to the surroundings or the outside.
Different ways of expelling air You can expel air from the building as follows:
All extensions of the power cords must be sufficiently thick and may only be used if they are completely extended.
Condensation drain with plug Exhaust filter Circulation filter
1. With a flat nozzle. The flat nozzle supplied can be used in different ways. It is possible to guide the flat nozzle through the open window and secure it firmly using straps and suction devices.
Make sure that there is a plug for the condensation drain and that it has been securely placed. Water may leak out after the unit becomes operational. Never operate the unit without the intake filter. Without an air intake filter, the plate fins of the evaporators become dirty and the unit’s performance is adversely affected.
The flat nozzle can also be hung through the partially opened window.
2. With a fixed connection to the exhaust hose (wall lead-through).
Make sure that people and objects, such as plants in the room, are not directly in the path of the expelled air.
Recommendations for optimum unit operation. In case of direct sunlight, make sure to close all curtains and blinds.
Keep doors and windows closed during operation.
8
The hose supplied is firmly connected to a wall lead-through. Lead-through kits can be purchased as accessories.
*
The exhaust hose must always be placed at an incline in the direction the air is flowing!
In some circumstances, low pressure can occur in the setup room when air is being expelled via a permanently attached exhaust hose, e.g. as a result of closed windows or doors. If the performance of the unit is adversely affected as a result, make sure that the pressure is corrected.
Initial Operation Prior to initial operation, the air intake and outlet openings must be inspected for foreign bodies and the air intake filter for dirt. Blocked or dirty grilles and filters must be cleaned immediately. See the chapter “Maintenance and Service“. Cooling mode 1. Switch the unit on with the “I/O” button. 2. Select cooling mode with the “Mode” button. The “AUTO” LED must be lit up. 3. Set the target temperature you want with the “THERMO CONTROL” buttons. The selected target temperature appears on the display. 4. If the set fan speed is too high or too low, the desired fan speed can be set by pressing the “MODE” button. Fan mode (circulation) 1. Switch the unit on with the “I/O” button
Information about timer mode (timer clock) The timer function is reset by pressing the “I/O” button. If the “SET” button is pressed while the timer is activated, the remaining time is shown on the display and can be changed using the same “SET” button. If the timer is programmed, this setting may be lost if the unit is disconnected from the power supply.
Shutting Down the Unit To shut down the unit, always switch it off with the “Power” button on the control panel or via the remote control. Only now can you unplug it from the power supply. Never shut the running unit off by pulling the power plug.
2. Select fan mode with the “MODE” button. The “FAN” LED must be lit up.
Storage
Timer Operation
1. Let the device run for approximately 2 hours in circulation mode (FAN) to dry the surface of the evaporator plate fins. This removes the remaining moisture from the unit and prevents unpleasant odours when the device is put back into operation.
The timer can be preset to switch the unit on or off for a maximum of 12 hours. Pressing the “SET” button increases the time until the unit is switched on or off by one hour. The number of hours is shown on the display. Timer switches unit off automatically: 1. W h e n the unit is on, press the “SET” button; the “OFF” LED lights up. 2. Set the desired amount of time until the unit is switched off with “SET” button. Keep in mind that after the setting has been made, the display changes to show the target temperature. 3. After the set amount of time has elapsed, the unit switches off automatically. Timer switches unit on automatically: The unit switches on with the most recently made settings. If you want different settings, you must switch the unit on, make the changes and then switch the unit off again. 1. When the unit is switched off, press the “SET” button ; the “ON” LED lights up. 2. Set the desired amount of time until the unit is switched on with the “SET” button. Keep in mind that after the setting is made, the display changes to show the target temperature. 3. After the set amount of time has elapsed, the unit switches on automatically.
If the unit is to be taken out of operation for a longer period of time, for example, over the winter, proceed as follows:
2. Switch off the unit by pressing the “I/O” button, unplug the unit from the power supply and roll up the power cord. 3. Make sure that the cable is not bent and there are no kinks. The cable can be attached to the back of the unit. 4. Place a suitable container under the condensation drain of the internal tank. The condensation drain is located at the bottom at the back of the unit. 5. Pull the plug from the condensation drain and collect the water that drains out. 6. Then replace the plug. Keep in mind that if there is no plug or it is inserted incorrectly, water may leak out after the unit has resumed operation. 7. Store the unit in an upright position in a dry location that is protected from direct sunlight and dust. 8. To prevent dust from getting inside the unit, protect it with, for example, a plastic cover.
9
Maintenance and Service
Cleaning the Filter
Regular maintenance and observance of some basic principles are required to ensure a long service life and to keep the unit functioning properly. However, the unit should be inspected at least once a year and thoroughly cleaned after long periods of use. The entire cooling system is a low-maintenance, closedloop system and may only be serviced by authorised service centres.
The unit is equipped with two air intake filters. These can be removed from the back of the unit. The filters must be cleaned at regular intervals. Clean the air filters after no more than 100 hours of operation. If the air is heavily contaminated, reduce this time period accordingly.
*
Before performing any work on the unit, make sure to switch the unit off and unplug the power cord.
Cleaning the plastic housing: For cleaning, use only a clean, soft and slightly moist towel to carefully wipe the housing. Please observe the following: Never use chemical cleaners or polish to clean the unit. They can damage the surface. Only use lukewarm water. Maximum 40°C . Make sure that no moisture gets into the unit. This can damage the internal components. Never clean the unit under a stream of water. Thoroughly clean the air intake and outlet openings on a regular basis. This is where the most dirt accumulates in the shortest period of time.
Wiring Diagram Legend PCB1 = PCB2 = SM = M1 = M2 = KM = CM = OLP = CX1 = CX2 = CX3 = TH = MS1 =
Control panel Control board Swing motor Circulation fan motor Exhaust fan motor Water pump Compressor motor Overload protection Capacitor motor (M1) Capacitor motor (M2) Capacitor (compressor motor) Thermostat sensor Microswitch (water tank full)
Colour code Y = W = R = BU = BR = BK = GR =
Yellow White Red Blue Brown Black Grey
10
*
Never operate the unit without the air filter. The air filter prevents the condenser from becoming dirty and the performance of the unit from being adversely affected. Filter
1. Switch the unit off with the On/ Off button on the control panel or the infrared remote control. 2. Unplug the unit. 3. Remove the filter from the unit. 4. Clean the dust that has accumulated from the filter. You can use a vacuum cleaner. 5. If the dust filter is very dirty, wash it with a lukewarm soap solution. 6. Let the filter air dry. 7. Replace the filter in the unit. 8. Make sure that the filter is dry and undamaged.
Troubleshooting This unit has been designed using state-of-the-art manufacturing processes and it has been tested repeatedly to ensure that it is working properly. However, should problems occur, refer to the following list. Problem
Possible cause
The unit does not start or Power failure. switches itself off automatically. Defective power fuse / main switch is off.
Check
Remedy
Are all other electrical compo- Check current and wait for the nents working? device to start again. Are all currents for lighting functional?
Replace power fuse. Switch on main switch.
Power supply line damaged.
Are all other electrical compo- Maintenance by authorised nents working? personnel.
Temperature range is either too high or too low.
Is the fan still working?
Water tank is full.
Is the “Tank Full” signal light lit Empty tank. See page 7. up?
The surrounding temperature is Does “E1“ appear on the disoutside of the operating range play? (16 to 35 °C). The unit is either not cooling at all or only cooling a little The exhaust hose is bent, extended, facing downwards or bit. blocked.
Keep the unit within operating temperature range 20 to 35°C.
Do not operate the unit outside of the operating range.
Does the cooling performance Make sure that the exhaust improve when the device is channel is not blocked. operated without an exhaust hose and without a filter?
Dirty filter Input and/or output opening blocked by foreign matter.
Are the filters dirty? Does the cooling performance Clean filter and reinsert it into improve when the device is the unit. operated without a filter?
Minimum clearance is insufficient.
Has the minimum distance of 50 cm been maintained?
Windows and doors open / thermal load increased.
Has something been changed Close windows and doors / in the design or application? reduce thermal load.
Maintain minimum distance.
Does the cooling performance Low pressure in the setup Correct pressure in the setup improve when a door or winroom when operating the unit. room. dow is opened? “Cooling” operating mode not set.
Is the “AUTO, HI, MED or LO“ Set operation mode to “AUTO, LED lit up in the display? HI, MED or LO“.
Device is switched on with the Is the “AUTO, HI, MED, LO or Press the I / 0 button again. timer function. FAN“ LED lit up? Temperature setting too high.
Is the temperature setting higher than the temperature of Lower temperature. the room?
Excess voltage due to lightning.
Unplug the unit from power Was there lightning recently in supply with switch 5 and rethe region? start.
The unit does not to respond Remote-control batteries are to the infrared remote con- dead or the transmission distrol. tance is too far. Polarity of the batteries is incorrect after replacement. Condensation water leaks out of the device.
Replace batteries / Does the button function work reduce distance or change loat a distance of approx. 1 m? cation. Is the polarity correct?
Insert the batteries correctly. Pay attention to the labels.
The device is not standing upIs the device upright? right.
Place upright and make sure it is firmly in place.
The plug for the condensation Is water dripping out of the drain is not inserted correctly condensation drain? or is damaged.
Insert the plug correctly or replace if necessary.
Should the unit still not be working despite these checks, please contact an authorised service centre.
*
Unplug the unit from the power supply before performing any work on it!
* 11
Technical Data Type designation Nominal cooling capacity
1)
kW
Energy efficiency class cooling Energy efficiency ratio EER
RKL 290
RKL 350
2.93
3.45
B
B
2.44
2.57 2.0
Dehumidification capacity max.
l/h
1.9
Operational area (size of room), approx.
m³
80
Operating range indoor unit
100 18 to 35
°C
R 407 C
Refrigerant Operating pressure max., refrigeration cycle Refrigerant, basic quantity
1900 / 2800
kPa kg
0.3
0.75
Circulating air volume per speed
m³/h
370 / 410 / 430
380 / 430 / 450
Sound pressure level per speed)
dB(A)
49 / 51 / 52
49 / 51 / 52
Exhaust air volume max.
m³/h V/Ph/Hz
230 / 1~ / 50
Protection type
IP
IP 20
Nominal power consumption1)
kW
1.20
1.34
Nominal current consumption1)
A
5.39
5.98
Power supply
Fresh air, max. 80% relative humidity
Operating medium mm/mm
1250 / 125
height
mm
825
width
mm
450
depth
mm
380
kg
35.0
Exhaust air hose, length / diameter Dimensions
Weight Ref. No.
1615290
1615350
1) Room temperature WB 35°C/DB 24°C 2) Distance 1m
Customer Service and Guarantee For the guarantee to be valid, the purchaser or his customer must completely fill out the “guarantee certificate” enclosed with all units and send it back to REMKO GmbH & Co. KG.
The units are repeatedly tested at the production site to ensure that they are working properly. If a malfunction occurs that cannot be eliminated by the operating personnel, please contact your dealer or contact person.
Environment and Recycling Important information about recycling!
Only authorised personnel may come into contact with the cold cycle. This ensures that refrigerant does not escape into the environment when the unit is being repaired. Both the refrigerant and the system parts are subject to special requirements for disposal. The refrigerant in use is a safety refrigerant. This means that, should damage occur, the quantities released will not cause injury to the respiratory systems of people and animals.
*
Do not touch the liquid refrigerant as it can freeze the skin!
Proper use
* 12
Operation/handling which does not comply with these instructions is prohibited! In cases of non-compliance, we assume no liability and the guarantee becomes null and void.
The manufacturer assumes no liability for damage resulting from non-compliance with manufacturer specifications and legal requirements, or if modifications are made to the units.
Exploded View 24
27
8
5
26 6
4
28
29
25 33
11 14
34
12
13
16
19 18
30
15
17 7
20 31
3 2
10
9
23
1 22
21
Spare Part List No. Description
Ref. No. RKL 290
RKL 350
1
Cover, front
1107000
1107000
2
Recessed grip
1107001
1107001
3 4 5 6 7 8 9 10
Control panel cover Air outlet grille Plate fins Adjustable lever (plate fins) Cover, rear Air filter (circulation) Unit bottom Transport wheel
1107002 1107003 1107004 1107005 1107006 1107007 1107008 1107009
1107002 1107003 1107004 1107005 1107006 1107007 1107008 1107009
11
Fan housing (circulation)
1107010
1107010
12 13 14 15 16 17 18
Fan wheel (exhaust) Fan motor (exhaust) Collection tray Condenser Water pump cpl. Floater (reservoir) Microswitch 1 (tank)
1107011 1107012 1107014 1107015 1107016 1107017 1107018
1107011 1107013 1107014 1107015 1107016 1107017 1107018
No. Description 19 Microswitch 2 (tank) 20 Evaporator 21 Compressor cpl. 22 Control panel foil 23 Control panel circuit board 24 Control board 25 Fan motor (circulation) 26 Evaporator housing 27 Fan housing (circulation) 28 Fan wheel (circulation) 29 Fin motor 30 Filter (exhaust) 31 Power supply with plug 32 Capacitor compressor 33 Capacitor fan motor (circulation) 34 Capacitor fan motor (exhaust) not Infrared remote control shown not Exhaust air hose cpl. shown
Ref. No. RKL 290
RKL 350
1107019 1107020 1107021 1107023 1107024 1107025 1107026 1107028 1107029 1107030 1107031 1107032 1107033 1107034 1107037 1107039
1107019 1107020 1107022 1107023 1107024 1107025 1107027 1107028 1107029 1107030 1107031 1107032 1107033 1107036 1107038 1107040
1613135
1613135
1107042
1107042
When orderig parts please indicate ref. no and machine no. (see type plate). We reserve the right to make changes to dimensions and design in the interest of technical progress.
13
Installation Diagram of the Wall-Lead Through Back pressure flap Safety guard Sealing cap
Telescope pipe
min. 400 mm
Installation instructions 1. Create a core hole in the outer wall (maximum wall thickness 480 mm) with a diameter of at least 135 mm. Keep an eye out for possible supply lines in this area! 2. Insert the telescope pipe in the wall lead-through that you created so that the outer pipe (100 mm diameter) is on the inner side of the wall. To prevent cold bridges, insulate the telescope pipe with a suitable insulation material. 3. Place bricks around the telescope pipe in the core hole so that it is aligned with both sides of the wall.
14
4. Attach the safety guard to the outer side of the wall with 4 screws. Mount the safety guard paying attention to the position of the rain drainage. 5. Insert the back pressure flap inside and attach it with 4 screws as well. The “oben” label on the back pressure flap must be visible from inside! 6. Close the opening on the back pressure flap with the sealing cap when taking the device out of operation, e.g. before winter, to prevent air circulation.