POST DATA - TJI PRO 360 LIVE LOAD: 20 LBS. LABEL LOCATION UNIT POST LOAD HEIGHT BEARING A A 817 96" 1.75 A B 817 96" 1.75 B 10'-7 1/4" A 3878 96" 1.75 B 10'-7 1/4" B 3878 96" 1.75 C 29'-1 1/4" A 2998 96" 1.75 C 29'-1 1/4" B 2998 96" 1.75 D 36'-8" A 2581 96" 1.75 D 36'-8" B 2581 96" 1.75 E 56'-0" A 5244 96" 1.75 E 56'-0" B 5244 96" 1.75 F 76'-0" A 1921 96" 1.75 F 76'-0" B 1921 96" 1.75 * EMPTY PIER LOAD IS COMBINED IN NUMBER ABOVE TJI PRO-360 SPLICE LOCATION DIMENSIONS ARE FROM HITCH END POST PIER LOAD* 32 1700 32 5 7800 5 4 6000 4 4 5200 4 7 10500 7 32 3900 32 BEAM TJI TJI TJI TJI TJI TJI TJI TJI TJI TJI TJI TJI LIVE LOAD: 20 LBS. FROM - TO UNIT 0" 7'-6" A 12'-11" - 15'-1" A 25'-4" - 27'-2" A 38'-3" - 40'-0" A 49'-7" - 51'-9" A 60'-2" - 61'-3" A 75'-3" - 76'-0" A 0" 7'-6" B 12'-11" - 15'-1" B 25'-4" - 27'-2" B 38'-3" - 40'-0" B 49'-7" - 51'-9" B 60'-2" - 61'-3" B 75'-3" - 76'-0" B MATE B B B B B B B A A A A A A A STRAP DATA OVERHANGS (F/R): WIND ZONE: 2 LOCATION UNIT A&B 10'-3" A&B 29'-4" A&B 36'-5" A&B 55'-6" A&B 65'-7 1/4" A&B 76'-0" A&B 9 / 9 STRAP 3 x 26 ga G-2 G-2 G-2 G-2 G-2 3 x 26 ga STRAP DATA OVERHANGS (F/R): WIND ZONE: 3 LOCATION UNIT A&B 5'-0" A&B 10'-3" A&B 29'-4" A&B 36'-5" A&B 55'-6" A&B 59'-4 3/8" A&B 65'-7 1/4" A&B 76'-0" A&B CHASSIS M.R. SPACING I-BEAM SIZE DRAWBAR LENGTH DRAWBAR ANGLE 9 / 9 STRAP 3 x 26 ga G-1 G-2 G-2 G-2 G-2 G-1 G-2 G-1 FLOOR JOIST SIZE JOIST MATERIAL JOIST SPACING WALL SIDEWALL HGT. EXT WALL SIZE EXT SIDING MATL TRIB ** JSTS NO STRAP 35'-10" 48'-5 7/8" 3 22'-9 3/8" TRIB ** JSTS NO STRAP 13'-9 3/8" 21'-1 7/8" 4 25'-6 1/8" 4 19'-0 1/2" 3 13'-0 3/8" SHEAR WALL DATA WIND ZONE: 1 512 LABEL UNIT WALL PANEL TYPE LENGTH NOTE A B 1 1SG E 14'-8 1/4" 3 x 26 ga STRAP B B 1 1LL S 11'-0 1/2" 2 JOISTS & 3 LAGS C B 1 2SG S 10'-9 1/4" 1 JOIST & 3 LAGS D A 1 2SG S 12'-0 3/4" 1 JOIST & 3 LAGS E A 1 1SG E 9'-4 3/4" 3 x 26 ga STRAP E B 1 1SG E 6'-9 1/2" 3 x 26 ga STRAP ** EMPTY TRIB FIELD IS COMBINED IN NUMBER ABOVE INFO 2x8 SYP 19.2 INFO 96" 2x4 VINYL LAP CEILING/ROOF INFO RAFTER CODE (CATH) RAFTER CODE (FLAT) FLM5-180-2.6A RAFTER SPACING 24" CEILING THICKNESS 5/16" CEILING MATERIAL GOLD BOND FRONT EAVE O'HANG 9" REAR EAVE O'HANG 9" FRONT GABLE O'HG 9" REAR GABLE O'HG 9" OPT. 5:12 ROOF SHEAR WALL DATA WIND ZONE: 1 LABEL UNIT WALL PANEL TYPE LENGTH NOTE A B 1 1SG E 14'-8 1/4" 3 x 26 ga STRAP B B 1 2SG S 10'-9 1/4" 1 JOIST & 3 LAGS C A 1 1SG E 9'-4 3/4" 3 x 26 ga STRAP WIND ZONE: 2 LABEL UNIT WALL PANEL TYPE LENGTH NOTE A B 1 1SG E 14'-8 1/4" 3 x 26 ga STRAP B B 1 1LL S 11'-6 5/8" 2 JOISTS & 3 LAGS C B 1 2LL S 10'-9 1/4" 2 JOISTS & 4 LAGS D A 1 2SG S 12'-0 3/4" 1 JOIST & 3 LAGS E A 1 1LL E 9'-4 3/4" 4.5 x 26 ga STRAP WIND ZONE: 3 LABEL UNIT WALL PANEL TYPE LENGTH NOTE A B 1 1SG E 14'-8 1/4" 3 x 26 ga STRAP B B 1 2SG S 11'-6 5/8" 1 JOIST & 3 LAGS C B 1 2SG S 11'-0 3/8" 1 JOIST & 3 LAGS D B 1 1LL S 10'-9 1/4" 1 JOIST & 3 LAGS E A 1 2LL S 12'-0 3/4" 2 JOISTS & 4 LAGS F A 1 1LL E 9'-4 3/4" 4.5 x 26 ga STRAP ** EMPTY TRIB FIELD IS COMBINED IN NUMBER ABOVE INFO 95 1/2" 12" 39" 60 TRIB ** JSTS NO STRAP 35'-10" 55'-0" 4 48'-5 7/8" 3 49'-6" 3 39'-1 5/8" TRIB ** JSTS NO STRAP 11'-5 1/4" 15'-9 5/8" 3 15'-9 5/8" 3 16'-3 1/8" 3 21'-7 3/4" 4 10'-9 3/4" WILLACOOCHEE 34 v.1.0 PRODUCT NAME SPRING HILL MODEL NO. DOOR SCHEDULE SYMBOL SIZE 3680 36 x 80 6/0x6/4 6/0 x 6/4 3680 36 x 80 WINDOW SCHEDULE SYMBOL SIZE A3053VS 30 x 53 A4053VS 40 x 53 V9553HD 95 x 53 A3027VS 30 x 27 V4053SH 40 x 53 V3027SH 30 x 27 V3053SH 30 x 53 DESCRIPTION BLANK SGD - SAFETY BLANK-INSWING DESCRIPTION V. SLIDER V. SLIDER H.DBL-END SLIDER V. SLIDER SGL HUNG WINDOW SGL HUNG WINDOW SGL HUNG WINDOW 0764L GLAZ VENT U VALUE 0.38 32.72 15.94 0.67 0.28 GLAZ VENT AREA 10.00 5.00 11.38 13.50 6.80 15.12 28.76 14.34 35.55 4.80 2.40 5.82 11.98 6.15 15.12 3.88 2.00 5.82 8.64 4.00 11.38 DRAWING TITLE APPROVED PFS Corporation Madison WI – 13 SPEC DRWG DRAWN BY: 3/2/06 HUD Manufactured Home Construction & Safety Standard SABRINA R. DATE: 03/02/06 SHT REV SPEC.1 341SH0764L T H E R M A L C TZ CEIL WALL FLOOR 1 14 11 11 1 14 11 11 1 14 11 11 1 14 11 11 1 14 11 11 1 14 11 11 1 21 11 11 1 21 11 11 1 21 11 11 1 21 11 11 1 21 11 11 1 21 11 11 1 28 11 22 1 28 11 22 1 28 11 22 1 28 11 22 1 28 11 22 1 28 11 22 2 14 11 11 2 14 11 11 2 14 11 11 2 14 11 11 2 14 11 11 2 14 11 11 2 21 11 11 2 21 11 11 2 21 11 11 2 21 11 11 2 21 11 11 2 21 11 11 2 28 11 22 2 28 11 22 2 28 11 22 2 28 11 22 2 28 11 22 2 28 11 22 SUBTRACT 2 S.F. OF A L C U L A T I O N R E S U L T S U DESCRIPTION 1.10 PHILIPS AL 1.10 PHILIPS AL 0.53 PHILIPS VINYL or PHILIPS AL w/STORM 0.53 PHILIPS VINYL or PHILIPS AL w/STORM 0.38 PHILIPS VINYL LOW-E 0.38 PHILIPS VINYL LOW-E 1.10 PHILIPS AL 1.10 PHILIPS AL 0.53 PHILIPS VINYL or PHILIPS AL w/STORM 0.53 PHILIPS VINYL or PHILIPS AL w/STORM 0.38 PHILIPS VINYL LOW-E 0.38 PHILIPS VINYL LOW-E 1.10 PHILIPS AL 1.10 PHILIPS AL 0.53 PHILIPS VINYL or PHILIPS AL w/STORM 0.53 PHILIPS VINYL or PHILIPS AL w/STORM 0.38 PHILIPS VINYL LOW-E 0.38 PHILIPS VINYL LOW-E 1.10 PHILIPS AL 1.10 PHILIPS AL 0.53 PHILIPS VINYL or PHILIPS AL w/STORM 0.53 PHILIPS VINYL or PHILIPS AL w/STORM 0.38 PHILIPS VINYL LOW-E 0.38 PHILIPS VINYL LOW-E 1.10 PHILIPS AL 1.10 PHILIPS AL 0.53 PHILIPS VINYL or PHILIPS AL w/STORM 0.53 PHILIPS VINYL or PHILIPS AL w/STORM 0.38 PHILIPS VINYL LOW-E 0.38 PHILIPS VINYL LOW-E 1.10 PHILIPS AL 1.10 PHILIPS AL 0.53 PHILIPS VINYL or PHILIPS AL w/STORM 0.53 PHILIPS VINYL or PHILIPS AL w/STORM 0.38 PHILIPS VINYL LOW-E 0.38 PHILIPS VINYL LOW-E GLAZING FOR EACH S.F. OF SKYLIGHT AREA DUCT TYPE RESULT MAX NOM AVAIL. OVERHEAD PASS 204.85 50.01 INSULATED PASS 216.76 61.92 OVERHEAD PASS 470.40 315.56 INSULATED PASS 497.75 342.91 OVERHEAD PASS 713.63 558.79 INSULATED PASS 755.12 600.28 OVERHEAD PASS 259.31 104.47 INSULATED PASS 275.67 120.83 OVERHEAD PASS 595.46 440.62 INSULATED PASS 633.02 478.18 OVERHEAD PASS 903.37 748.53 INSULATED PASS 960.35 805.51 OVERHEAD PASS 339.42 184.58 INSULATED PASS 359.46 204.62 OVERHEAD PASS 779.42 624.58 INSULATED PASS 825.42 670.58 OVERHEAD PASS 1182.4 1027.6 INSULATED PASS 1252.2 1097.4 OVERHEAD N/A 80.96 -73.88 INSULATED N/A 91.32 -63.52 OVERHEAD PASS 185.90 31.06 INSULATED PASS 209.68 54.84 OVERHEAD PASS 282.03 127.19 INSULATED PASS 318.11 163.27 OVERHEAD N/A 135.42 -19.42 INSULATED N/A 150.22 -4.62 OVERHEAD PASS 310.97 156.13 INSULATED PASS 344.96 190.12 OVERHEAD PASS 471.77 316.93 INSULATED PASS 523.33 368.49 OVERHEAD PASS 215.53 60.69 INSULATED PASS 234.01 79.17 OVERHEAD PASS 494.92 340.08 INSULATED PASS 537.36 382.52 OVERHEAD PASS 750.84 596.00 INSULATED PASS 815.21 660.37 RECOMMENDED A/C SIZES STATE DESIGN TEMP TONS AL ALL 5.0 FL ALL 5.0 GA ALL 5.0 LA ALL 5.0 MS ALL 5.0 NC ALL 4.0 SC ALL 5.0 OPTIONAL DOOR EQUIVALENT GLAZING WALL WINDOW 11 PHILIPS AL 11 PHILIPS AL 11 PHILIPS AL 11 PHILIPS AL 11 PHILIPS AL 11 PHILIPS AL 11 PHILIPS AL 11 PHILIPS AL 11 PHILIPS AL 11 PHILIPS AL 11 PHILIPS AL 11 PHILIPS AL 11 PHILIPS AL 11 PHILIPS AL 11 PHILIPS AL 11 PHILIPS AL 11 PHILIPS VINYL or PHILIPS AL 11 PHILIPS VINYL or PHILIPS AL 11 PHILIPS VINYL or PHILIPS AL 11 PHILIPS VINYL or PHILIPS AL 11 PHILIPS VINYL or PHILIPS AL 11 PHILIPS VINYL or PHILIPS AL 11 PHILIPS VINYL or PHILIPS AL 11 PHILIPS VINYL or PHILIPS AL 11 PHILIPS VINYL or PHILIPS AL 11 PHILIPS VINYL or PHILIPS AL 11 PHILIPS VINYL or PHILIPS AL 11 PHILIPS VINYL or PHILIPS AL 11 PHILIPS VINYL or PHILIPS AL 11 PHILIPS VINYL or PHILIPS AL 11 PHILIPS VINYL or PHILIPS AL 11 PHILIPS VINYL or PHILIPS AL 11 PHILIPS VINYL LOW-E 11 PHILIPS VINYL LOW-E 11 PHILIPS VINYL LOW-E 11 PHILIPS VINYL LOW-E 11 PHILIPS VINYL LOW-E 11 PHILIPS VINYL LOW-E 11 PHILIPS VINYL LOW-E 11 PHILIPS VINYL LOW-E 11 PHILIPS VINYL LOW-E 11 PHILIPS VINYL LOW-E 11 PHILIPS VINYL LOW-E 11 PHILIPS VINYL LOW-E 11 PHILIPS VINYL LOW-E 11 PHILIPS VINYL LOW-E 11 PHILIPS VINYL LOW-E 11 PHILIPS VINYL LOW-E AREA w/STORM w/STORM w/STORM w/STORM w/STORM w/STORM w/STORM w/STORM w/STORM w/STORM w/STORM w/STORM w/STORM w/STORM w/STORM w/STORM DOOR 34 x 76 1/2 JAL SLIDER 34 x 76 BLANK 34 x 76 BLANK-INSWING 34 x 76 BLANK-INSWING 34 x 76 COTTAGE 34 x 76 DIAMOND 36 x 75 DL GUNSLOT-INSWING 36 x 75 GUNSLOT-INSWING 36 x 76 BLANK 36 x 76 BLANK-INSWING 36 x 76 BLANK-INSWING 36 x 76 DIAMOND-INSWING 36 x 80 BLANK 36 x 80 BLANK-INSWING 5/6 x 6/4 ATRIUM - SAFETY 6/0 x 6/4 SGD - SAFETY 34 x 76 1/2 JAL SLIDER 34 x 76 BLANK 34 x 76 BLANK-INSWING 34 x 76 BLANK-INSWING 34 x 76 COTTAGE 34 x 76 DIAMOND 36 x 75 DL GUNSLOT-INSWING 36 x 75 GUNSLOT-INSWING 36 x 76 BLANK 36 x 76 BLANK-INSWING 36 x 76 BLANK-INSWING 36 x 76 DIAMOND-INSWING 36 x 80 BLANK 36 x 80 BLANK-INSWING 5/6 x 6/4 ATRIUM - SAFETY 6/0 x 6/4 SGD - SAFETY 34 x 76 1/2 JAL SLIDER 34 x 76 BLANK 34 x 76 BLANK-INSWING 34 x 76 BLANK-INSWING 34 x 76 COTTAGE 34 x 76 DIAMOND 36 x 75 DL GUNSLOT-INSWING 36 x 75 GUNSLOT-INSWING 36 x 76 BLANK 36 x 76 BLANK-INSWING 36 x 76 BLANK-INSWING 36 x 76 DIAMOND-INSWING 36 x 80 BLANK 36 x 80 BLANK-INSWING 5/6 x 6/4 ATRIUM - SAFETY 6/0 x 6/4 SGD - SAFETY AREA 6.22 4.44 1.42 3.37 5.51 6.57 7.81 3.02 4.70 1.50 3.57 4.14 5.74 3.76 10.42 21.80 14.28 10.20 3.26 7.75 12.64 15.09 17.93 6.95 10.80 3.45 8.20 9.50 13.18 8.64 23.93 50.07 21.66 15.47 4.95 11.75 19.18 22.90 27.21 10.54 16.38 5.24 12.45 14.41 20.00 13.10 36.31 75.96 DESIGN, CERTIFICATION & ECONOMY TEMPERATURES STATE TYPE FURNACE AL ELEC 20 KW ELECTRIC FURN-A/C READY UP AL GAS 77K BTUH 80% AFUE AUTO GAS FURN FL ELEC 15 KW ELECTRIC FURN-A/C READY UP FL ELEC 17 KW ELECTRIC FURN-A/C READY UP FL GAS 70K BTUH 80% AFUE AUTO GAS FURN FL GAS 77K BTUH 80% AFUE AUTO GAS FURN GA ELEC 17 KW ELECTRIC FURN-A/C READY UP GA ELEC 20 KW ELECTRIC FURN-A/C READY UP GA GAS 70K BTUH 80% AFUE AUTO GAS FURN GA GAS 77K BTUH 80% AFUE AUTO GAS FURN LA ELEC 17 KW ELECTRIC FURN-A/C READY UP LA ELEC 20 KW ELECTRIC FURN-A/C READY UP LA GAS 70K BTUH 80% AFUE AUTO GAS FURN LA GAS 77K BTUH 80% AFUE AUTO GAS FURN MS ELEC 20 KW ELECTRIC FURN-A/C READY UP MS GAS 77K BTUH 80% AFUE AUTO GAS FURN NC ELEC 17 KW ELECTRIC FURN-A/C READY UP NC ELEC 20 KW ELECTRIC FURN-A/C READY UP NC GAS 70K BTUH 80% AFUE AUTO GAS FURN NC GAS 77K BTUH 80% AFUE AUTO GAS FURN SC ELEC 17 KW ELECTRIC FURN-A/C READY UP SC ELEC 20 KW ELECTRIC FURN-A/C READY UP SC GAS 70K BTUH 80% AFUE AUTO GAS FURN SC GAS 77K BTUH 80% AFUE AUTO GAS FURN DT CT ET 16 -6 17 16 0 21 29 12 32 29 7 27 29 7 27 29 0 21 21 7 27 21 -6 17 21 7 27 21 0 21 25 7 27 25 -6 17 25 7 27 25 0 21 19 -6 17 19 0 21 14 -4 18 14 -18 8 14 -4 18 14 -12 13 22 7 27 22 -6 17 22 7 27 22 0 21 TO 4 TONS TO 4 TONS TO 4 TONS TO 4 TONS TO 4 TONS TO 4 TONS TO 4 TONS TO 4 TONS TO 4 TONS TO 4 TONS TO 4 TONS TO 4 TONS WILLACOOCHEE 34 v.1.0 PRODUCT NAME SPRING HILL MODEL NO. 0764L DRAWING TITLE STANDARD OPENINGS QTY SIZE 1 36 x 80 1 36 x 80 1 6/0 x 6/4 1 30 x 27 2 30 x 53 6 40 x 53 1 95 x 53 TOTAL WINDOW AREA SEE THERMAL CHART DESCRIPTION TYPE BLANK-INSWING DOOR BLANK DOOR SGD - SAFETY DOOR V. SLIDER WINDOW V. SLIDER WINDOW V. SLIDER WINDOW H.DBL-END SLIDER WINDOW : FOR WINDOW U VALUES AREA 20.00 20.00 37.98 5.82 11.38 15.12 35.55 TOTAL 20.00 20.00 37.98 5.82 22.77 90.70 35.55 154.85 U VALUE 0.280 0.380 0.670 APPROVED PFS Corporation Madison WI – 13 THERMAL SPECS DRAWN BY: 3/2/06 HUD Manufactured Home Construction & Safety Standard SABRINA R. DATE: 03/02/06 SHT REV TS.1 341SH0764L E N E R G Y S T A R T H E R M A L CR U0 WALL HEAT DUCT TYPE CEIL 2 0.092 2x4 GAS INSUL 14 2 0.092 2x4 GAS OVERHEAD 14 2 0.069 2x4 GAS INSUL 28 2 0.070 2x4 GAS OVERHEAD 28 2 0.082 2x4 GAS INSUL 21 2 0.083 2x4 GAS OVERHEAD 21 2 0.088 2x4 GAS INSUL 14 2 0.088 2x4 GAS OVERHEAD 14 2 0.065 2x4 GAS INSUL 28 2 0.066 2x4 GAS OVERHEAD 28 2 0.079 2x4 GAS INSUL 21 2 0.079 2x4 GAS OVERHEAD 21 2 0.092 2x4 ELECTRIC INSUL 14 2 0.092 2x4 ELECTRIC OVERHEAD 14 2 0.069 2x4 ELECTRIC INSUL 28 2 0.070 2x4 ELECTRIC OVERHEAD 28 2 0.082 2x4 ELECTRIC INSUL 21 2 0.083 2x4 ELECTRIC OVERHEAD 21 2 0.088 2x4 ELECTRIC INSUL 14 2 0.088 2x4 ELECTRIC OVERHEAD 14 2 0.065 2x4 ELECTRIC INSUL 28 2 0.066 2x4 ELECTRIC OVERHEAD 28 2 0.079 2x4 ELECTRIC INSUL 21 2 0.079 2x4 ELECTRIC OVERHEAD 21 3 0.088 2x4 GAS INSUL 14 3 0.089 2x4 GAS OVERHEAD 14 3 0.065 2x4 GAS INSUL 28 3 0.067 2x4 GAS OVERHEAD 28 3 0.079 2x4 GAS INSUL 21 3 0.080 2x4 GAS OVERHEAD 21 3 0.092 2x4 ELECTRIC INSUL 14 3 0.093 2x4 ELECTRIC OVERHEAD 14 3 0.069 2x4 ELECTRIC INSUL 28 3 0.071 2x4 ELECTRIC OVERHEAD 28 3 0.082 2x4 ELECTRIC INSUL 21 3 0.084 2x4 ELECTRIC OVERHEAD 21 3 0.088 2x4 ELECTRIC INSUL 14 3 0.089 2x4 ELECTRIC OVERHEAD 14 3 0.065 2x4 ELECTRIC INSUL 28 3 0.067 2x4 ELECTRIC OVERHEAD 28 3 0.079 2x4 ELECTRIC INSUL 21 3 0.080 2x4 ELECTRIC OVERHEAD 21 4 0.088 2x4 GAS INSUL 14 4 0.089 2x4 GAS OVERHEAD 14 4 0.065 2x4 GAS INSUL 28 4 0.067 2x4 GAS OVERHEAD 28 4 0.079 2x4 GAS INSUL 21 4 0.080 2x4 GAS OVERHEAD 21 4 0.088 2x4 ELECTRIC INSUL 14 4 0.089 2x4 ELECTRIC OVERHEAD 14 4 0.065 2x4 ELECTRIC INSUL 28 4 0.067 2x4 ELECTRIC OVERHEAD 28 4 0.079 2x4 ELECTRIC INSUL 21 4 0.080 2x4 ELECTRIC OVERHEAD 21 PROGRAMMABLE THERMOSTAT AND MAXIMUM 5% R E S U L T S WALL FLOOR WINDOW U SHGC WINDOW DESCRIPTION RESULT DUCT MIN 11 11 0.53 0.76 PHILIPS VINYL N/A 8 11 11 0.53 0.76 PHILIPS VINYL N/A 8 11 22 0.53 0.76 PHILIPS VINYL N/A 8 11 22 0.53 0.76 PHILIPS VINYL N/A 8 11 11 0.53 0.76 PHILIPS VINYL N/A 8 11 11 0.53 0.76 PHILIPS VINYL N/A 8 11 11 0.38 0.40 PHILIPS VINYL LOW-E N/A 8 11 11 0.38 0.40 PHILIPS VINYL LOW-E N/A 8 11 22 0.38 0.40 PHILIPS VINYL LOW-E N/A 8 11 22 0.38 0.40 PHILIPS VINYL LOW-E N/A 8 11 11 0.38 0.40 PHILIPS VINYL LOW-E N/A 8 11 11 0.38 0.40 PHILIPS VINYL LOW-E N/A 8 11 11 0.53 0.76 PHILIPS VINYL N/A 8 11 11 0.53 0.76 PHILIPS VINYL N/A 8 11 22 0.53 0.76 PHILIPS VINYL N/A 8 11 22 0.53 0.76 PHILIPS VINYL N/A 8 11 11 0.53 0.76 PHILIPS VINYL N/A 8 11 11 0.53 0.76 PHILIPS VINYL N/A 8 11 11 0.38 0.40 PHILIPS VINYL LOW-E N/A 8 11 11 0.38 0.40 PHILIPS VINYL LOW-E N/A 8 11 22 0.38 0.40 PHILIPS VINYL LOW-E N/A 8 11 22 0.38 0.40 PHILIPS VINYL LOW-E N/A 8 11 11 0.38 0.40 PHILIPS VINYL LOW-E N/A 8 11 11 0.38 0.40 PHILIPS VINYL LOW-E N/A 8 11 11 0.38 0.40 PHILIPS VINYL LOW-E N/A 6 11 11 0.38 0.40 PHILIPS VINYL LOW-E N/A 6 11 22 0.38 0.40 PHILIPS VINYL LOW-E PASS 6 11 22 0.38 0.40 PHILIPS VINYL LOW-E PASS 6 11 11 0.38 0.40 PHILIPS VINYL LOW-E PASS 6 11 11 0.38 0.40 PHILIPS VINYL LOW-E PASS 6 11 11 0.53 0.76 PHILIPS VINYL N/A 6 11 11 0.53 0.76 PHILIPS VINYL N/A 6 11 22 0.53 0.76 PHILIPS VINYL PASS 6 11 22 0.53 0.76 PHILIPS VINYL PASS 6 11 11 0.53 0.76 PHILIPS VINYL N/A 6 11 11 0.53 0.76 PHILIPS VINYL N/A 6 11 11 0.38 0.40 PHILIPS VINYL LOW-E N/A 6 11 11 0.38 0.40 PHILIPS VINYL LOW-E N/A 6 11 22 0.38 0.40 PHILIPS VINYL LOW-E PASS 6 11 22 0.38 0.40 PHILIPS VINYL LOW-E PASS 6 11 11 0.38 0.40 PHILIPS VINYL LOW-E N/A 6 11 11 0.38 0.40 PHILIPS VINYL LOW-E N/A 6 11 11 0.38 0.40 PHILIPS VINYL LOW-E PASS 6 11 11 0.38 0.40 PHILIPS VINYL LOW-E PASS 6 11 22 0.38 0.40 PHILIPS VINYL LOW-E PASS 6 11 22 0.38 0.40 PHILIPS VINYL LOW-E PASS 6 11 11 0.38 0.40 PHILIPS VINYL LOW-E PASS 6 11 11 0.38 0.40 PHILIPS VINYL LOW-E PASS 6 11 11 0.38 0.40 PHILIPS VINYL LOW-E PASS 6 11 11 0.38 0.40 PHILIPS VINYL LOW-E PASS 6 11 22 0.38 0.40 PHILIPS VINYL LOW-E PASS 6 11 22 0.38 0.40 PHILIPS VINYL LOW-E PASS 6 11 11 0.38 0.40 PHILIPS VINYL LOW-E PASS 6 11 11 0.38 0.40 PHILIPS VINYL LOW-E PASS 6 DUCT LEAKAGE MAX NOM -281 -275 46.9 34.1 -145 -150 -426 -417 71.2 51.8 -221 -227 -338 -332 -10.7 -22.8 -203 -207 -513 -503 -16.2 -34.5 -308 -314 -10.8 -26.8 486.3 442.0 194.5 162.9 -122 -131 205.4 177.5 13.0 -6.4 -186 -199 311.5 269.3 19.7 -9.7 775.9 750.0 1273 1219 981.1 939.8 426.3 404.8 923.3 873.6 631.5 594.5 ACTUAL 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 154.8 DIFF -436 -430 -108 -121 -300 -305 -581 -572 -83.7 -103 -376 -382 -493 -487 -166 -178 -358 -362 -668 -658 -171 -189 -463 -468 -166 -182 331.5 287.1 39.6 8.0 -277 -286 50.5 22.7 -142 -161 -340 -354 156.7 114.5 -135 -165 621.0 595.2 1118 1064 826.2 784.9 271.4 249.9 768.5 718.7 476.6 439.6 QTY SIZE DESCRIPTION 1 36 x 80 BLANK 1 36 x 80 BLANK-INSWING 1 6/0 x 6/4 SGD - SAFETY 1 30 x 27 SGL HUNG WINDOW 2 30 x 53 SGL HUNG WINDOW 6 40 x 53 SGL HUNG WINDOW 1 95 x 53 H.DBL-END SLIDER TOTAL WINDOW AREA : SEE ENERGY STAR CHART FOR WINDOW U TYPE DOOR DOOR DOOR WINDOW WINDOW WINDOW WINDOW AREA 20.0 20.0 38.0 5.8 11.4 15.1 35.6 TOTAL U VALUE 20.0 0.380 20.0 0.280 38.0 0.670 5.8 22.8 90.7 35.6 154.85 VALUES WILLACOOCHEE 34 v.1.0 PRODUCT NAME SPRING HILL MODEL NO. 0764L APPROVED PFS Corporation Madison WI – 13 DRAWING TITLE THERMAL SPECS 3/2/06 HUD Manufactured Home Construction & Safety Standard DRAWN BY: SABRINA R. DATE: 03/02/06 SHT OPT ENERGY STAR SEE TS.1 FOR OPT DOORS REV TS.2 341SH0764L v.1.0 L E G E N D 11'-2 1/2" 8'-9 1/2" 4'-8 1/2" 11'-2 1/2" 11'-0" 18'-1" 11'-0" RECEPTACLE SWITCH A3027VS ENTRY COFFEE LINEN 30 30 5 SHELF OR OPT.O'HD 4 4 180" OPT SHLVS AND SEAT SI NK 4 4 13 5 1 OPT 4 4 1 42 GFI 1 " HI GH BA R OPT 60" BUFFET LAV RAISE CAB 4" GFI 30 4 F E 30 A3053VS 15 SA OPT 30 6 5 5 5 5 30 A 7 7 19 AIR SUPPLY SA 14"RETURN AIR RA 5 OPT FIREPLACE SOLAR TUBE ST EGRESS W/ RAG 30 T 2 6 SA 6 PANEL BOX B OPT (2)10x4 RAG 5 OPT 30 REQUIRED FOR APPLICABLE WZ UPLIFT RECESSED LIGHT EXHAUST FAN OPT RA HALL 6X6 FLUTTED COLUMN 6 FLUORESCENT LIGHT 5 17 C OPT 2 30 6 LIGHT FIXTURE 30 5 HITCH END 19 5 RECEPT LOCATION @ 44" W/ OPT F/P REQ'D W/ OPT BUFFET 5 D 5 30 16 4 OPT UTILITY 8 F/S RANGE 48 VANITY 4 W/ HUSH BUTTON LINEN 5 GFI OPT SMOKE ALARM OPT SHELF OR OPT O'HD W/ SHLF OPT FIREPLACE DEN 326.8 sqf (1) SMOKE ALARM 14 30 30'-0" 4 SHIRT & SKIRT 4 9 0 4 RE-CENTER WNDWS W/ OPT F/P AND ETC 5 OPT ENTRTNMNT CENTER 46" H SHLVS 1 5 DINING RM 168.6 sqf (1) KITCHEN 4 19 2 DESK BATH 1 GFI 2 2 REFER PANTRY 4 2 368 A4053VS SAFETY GFI BAR 2 HEAT TAPE RECEPT ON UNDERSIDE OF FLOOR 5 ENTRY 19 2 A3053VS 6/0x6/4 FA 4 A3053VS 5 30 ALCOVE A3027VS GFI WH 5 42" ARCHED OPENING 36" FROM FLOOR OPT 5 T THERMOSTAT RAG RETURN AIR GRILLE OVERHEAD REGISTER FLOOR REGISTER WALL-MOUNTED REGISTER 30 7 FAN W/ LIGHT CROSS-OVER LOCATION GFI 7 7 X SUPPORT POST 180" 5 6 6 7 BATH 2 6 30 6 6 6 7 SHEARWALL 7 OPT 7 BEDROOM 1 235.7 sqf 6 BEDROOM 4 136.4 sqf 7 BEDROOM 2 139.6 sqf 180 x 76'-0" B 180 x 76'-0" x C BEDROOM 3 134.2 sqf 30 A3053VS 7 LIVING ROOM 277.4 sqf A 7 7 6 6 A4053VS 368 A4053VS OPT 0 ENTRY 6 6 6 V9553HD EGRESS 7 7 7 7 A4053VS A4053VS A4053VS EGRESS EGRESS EGRESS OPT 6 WILLACOOCHEE 34 PRODUCT NAME 16'-6" 18'-9 1/8" 11'-0" 5'-3 1/8" 11'-8 7/8" 2'-2 7/8" 10'-6" SPRING HILL 76'-0" C Z1 17'-7 5/8" E Z2 10'-0" F Z3 10'-0" D Z2 17'-7 5/8" E Z3 17'-7 5/8" THIS FLOOR PLAN AND ATTACHED OPTION DETAILS (IF APPLICABLE) IS DESIGNED TO MEET THE FOLLOWING STRUCTURAL REQUIREMENTS: 1, 2 & 3 ROOF LOAD(S)__________LBS. 20 WIND ZONE(S)__________ NOTES: B Z1 38'-0" C Z2 22'-9" D Z3 15'-9 1/8" 1. RECEPT SHALL NOT BE INSTALLED WITHIN 30" OF TUB/SHOWER SPACE. 2. ELECTRICAL WALL PLATES SHALL NOT BE INSTALLED WITHIN 6" OF A RANGE OR COOKTOP. 3. THE MAXIMUM TRAVEL DISTANCE FROM ANY BEDROOM DOORWAY TO AN 33.1 LF. ENTRY DOOR IS ______ 4. ROOM TITLES INCLUDING (#) INDICATES SQUARE FOOTAGE HAS BEEN COMBINED FOR GLAZING/VENTING REQUIREMENTS. 5. OPT REMOTE HEATING/COOLING APPLIANCE AND THERMOSTAT TO BE SUPPLIED AND INSTALLED BY OTHERS. OMIT FURNACE BRANCH CIRCUIT & RECEPTACLE OUTLETS. C Z3 15'-1 1/2" A Z1 20'-4 1/2" A Z2 5'-3" A Z3 5'-3" B Z2 20'-4 1/2" B Z3 12'-2 7/8" MODEL NO. 0764L DRAWING TITLE FLOOR PLAN DRAWN BY: Mary S. #13 DATE: Conforms to HUD MHCSS 8/15/06 08/14/06 SHT REV FP.1 341SH0764L B v.1.0 L E G E N D 11'-2 1/2" 8'-9 1/2" 4'-8 1/2" 11'-2 1/2" 11'-0" 18'-1" 11'-0" RECEPTACLE SWITCH V3027SH ENTRY COFFEE LINEN PANTRY LAV 4 5 SHELF OR OPT.O'HD 30 4 180" OPT SHLVS AND SEAT SI NK 4 4 13 5 1 OPT 4 4 1 42 GFI 1 " HI GH BA R OPT 60" BUFFET LAV RAISE CAB 4" OPT 2 30 30 4 6 30 V3053SH 15 OPT RA SA OPT 30 6 5 OPT FIREPLACE 5 5 SOLAR TUBE ST EGRESS W/ RAG 30 5 AIR SUPPLY SA 14"RETURN AIR RA T 2 6 SA 6 PANEL BOX 5 OPT (2)10x4 RAG 5 OPT 7 30 REQUIRED FOR APPLICABLE WZ UPLIFT RECESSED LIGHT EXHAUST FAN 17 HALL 6X6 FLUTTED COLUMN 6 FLUORESCENT LIGHT 5 RECEPT LOCATION @ 44" W/ OPT F/P REQ'D W/ OPT BUFFET 5 GFI LIGHT FIXTURE HITCH END 19 5 16 4 5 30 UTILITY 8 F/S RANGE 48 VANITY 4 W/ HUSH BUTTON OPT 5 GFI OPT SMOKE ALARM LINEN OPT SHELF OR OPT O'HD W/ SHLF OPT FIREPLACE DEN 326.8 sqf (1) SMOKE ALARM 14 30 30'-0" 4 SHIRT & SKIRT 4 9 0 4 RE-CENTER WNDWS W/ OPT F/P AND ETC 5 OPT ENTRTNMNT CENTER 46" H SHLVS 1 5 DINING RM 168.6 sqf (1) KITCHEN 4 19 2 DESK BATH 1 GFI 2 2 REFER 4 30 2 36 8 V4053SH SAFETY GFI BAR 2 HEAT TAPE RECEPT ON UNDERSIDE OF FLOOR 5 ENTRY 19 2 V3053SH 6/0x6/4 FA 4 V3053SH 5 30 ALCOVE V3027SH GFI WH 5 42" ARCHED OPENING 36" FROM FLOOR OPT 5 T THERMOSTAT 30 7 FLOOR REGISTER WALL-MOUNTED REGISTER 30 7 RETURN AIR GRILLE OVERHEAD REGISTER 5 30 19 RAG FAN W/ LIGHT CROSS-OVER LOCATION GFI 7 7 X SUPPORT POST 180" 5 BATH 2 6 6 7 SHEARWALL 6 30 6 6 6 7 7 OPT 7 BEDROOM 1 235.7 sqf BEDROOM 4 136.4 sqf 6 7 BEDROOM 2 139.6 sqf 180 x 76'-0" B 180 x 76'-0" x C BEDROOM 3 134.2 sqf 30 V3053SH 7 LIVING ROOM 277.4 sqf A 7 7 6 368 6 V4053SH V4053SH 0 ENTRY OPT 6 6 6 V9553HD EGRESS 7 7 7 7 V4053SH V4053SH V4053SH EGRESS EGRESS EGRESS OPT 6 WILLACOOCHEE 34 PRODUCT NAME 16'-6" 18'-9 1/8" 11'-0" 5'-3 1/8" 11'-8 7/8" 2'-2 7/8" 10'-6" SPRING HILL 76'-0" NOTES: THIS FLOOR PLAN AND ATTACHED OPTION DETAILS (IF APPLICABLE) IS DESIGNED TO MEET THE FOLLOWING STRUCTURAL REQUIREMENTS: 1, 2 & 3 ROOF LOAD(S)__________LBS. 20 WIND ZONE(S)__________ OPT. VINYL WINDOWS 1. RECEPT SHALL NOT BE INSTALLED WITHIN 30" OF TUB/SHOWER SPACE. 2. ELECTRICAL WALL PLATES SHALL NOT BE INSTALLED WITHIN 6" OF A RANGE OR COOKTOP. 3. THE MAXIMUM TRAVEL DISTANCE FROM ANY BEDROOM DOORWAY TO AN 33.1 LF. ENTRY DOOR IS ______ 4. ROOM TITLES INCLUDING (#) INDICATES SQUARE FOOTAGE HAS BEEN COMBINED FOR GLAZING/VENTING REQUIREMENTS. 5. EGRESS WINDOW(S) WITH LESS THAN 5.0 SQ.FT. VENT AREA MEET EGRESS REQM'T THROUGH SASH REMOVAL PER WINDOW MANUFACTURER'S INSTRUCTIONS LOCATED ON WINDOW. 6. FOR SUPPORT POST LOCATIONS, SIDEWALL TRIBUTARIES AND SHEARWALL CONFIGURATIONS REFER TO APPLICABLE FLOOR PLAN AND SPECIFICATIONS SHEET. 7. OPT REMOTE HEATING/COOLING APPLIANCE AND THERMOSTAT TO BE SUPPLIED AND INSTALLED BY OTHERS. OMIT FURNACE BRANCH CIRCUIT & RECEPTACLE OUTLETS. MODEL NO. 0764L DRAWING TITLE OPT FLOOR PLAN DRAWN BY: Mary S. #13 DATE: Conforms to HUD MHCSS 8/15/06 08/14/06 SHT REV FP.2 341SH0764L B v.1.0 L E G E N D 11'-2 1/2" 8'-9 1/2" 4'-8 1/2" 11'-2 1/2" 11'-0" 18'-1" 11'-0" RECEPTACLE SWITCH A3027VS ENTRY LINEN 5 SHELF OR OPT.O'HD 4 30 30 DESK 4 180" 48 4 OPT SHLVS AND SEAT 4 4 13 1 42 GFI GH 5 R OPT 60" BUFFET LAV RAISE CAB 4" GFI OPT 2 30 4 F E A3053VS 30 6 5 5 5 5 5 A 7 30 7 AIR SUPPLY SA 14"RETURN AIR RA B OPT FIREPLACE SOLAR TUBE ST EGRESS W/ RAG 30 T 2 6 SA 6 PANEL BOX SA OPT C OPT (2)10x4 RAG 5 OPT 30 REQUIRED FOR APPLICABLE WZ UPLIFT 15 OPT RA HALL 6X6 FLUTTED COLUMN 6 30 30 6 RECESSED LIGHT EXHAUST FAN 17 HITCH END 19 FLUORESCENT LIGHT 5 RECEPT LOCATION @ 44" W/ OPT F/P REQ'D W/ OPT BUFFET 5 D LIGHT FIXTURE 30 5 16 4 5 30 1 " HI OPT UTILITY 4 BA LINEN 5 8 4 SMOKE ALARM W/ HUSH BUTTON 1 OPT SI NK OPT F/S RANGE 4 VANITY 30'-0" 4 SHIRT & SKIRT 19 SMOKE ALARM 14 OPT SHELF OR OPT O'HD W/ SHLF OPT FIREPLACE DEN 326.8 sqf (1) GFI 4 9 OPT ENTRTNMNT CENTER 46" H SHLVS 4 RE-CENTER WNDWS W/ OPT F/P AND ETC 5 DINING RM 168.6 sqf (1) KITCHEN 1 5 0 BATH 1 GFI 2 3 68 A4053VS SAFETY 4 2 2 REFER PANTRY LAV 2 HEAT TAPE RECEPT ON UNDERSIDE OF FLOOR 5 ENTRY COFFEE GFI BAR 2 A3053VS 6/0x6/4 FA 19 2 A3053VS 5 30 4 A3027VS GFI WH 5 42" ARCHED OPENING 36" FROM FLOOR OPT 5 T THERMOSTAT RAG FLOOR REGISTER WALL-MOUNTED REGISTER 30 19 RETURN AIR GRILLE OVERHEAD REGISTER 5 30 FAN W/ LIGHT 7 CROSS-OVER LOCATION GFI 7 7 X SUPPORT POST 180" 5 6 6 7 6 SHEARWALL BATH 2 30 6 6 6 7 7 OPT 7 BEDROOM 1 235.7 sqf BEDROOM 4 136.4 sqf 6 7 BEDROOM 2 139.6 sqf 180 x 76'-0" B 180 x 76'-0" x C BEDROOM 3 134.2 sqf 30 A3053VS 7 LIVING ROOM 277.4 sqf A 7 7 6 6 A4053VS 368 A4053VS OPT 0 6 ENTRY 6 6 V9553HD EGRESS 7 7 7 7 A4053VS A4053VS A4053VS EGRESS EGRESS EGRESS OPT 6 WILLACOOCHEE 34 PRODUCT NAME 16'-6" 18'-9 1/8" 11'-0" 5'-3 1/8" 11'-8 7/8" 2'-2 7/8" 10'-6" SPRING HILL 76'-0" E Z1 26'-9 5/8" D Z1 47'-3" C Z1 42'-2 7/8" B Z1 54'-7 1/8" A Z1 32'-9 5/8" OPT. 5:12 ROOF THIS FLOOR PLAN AND ATTACHED OPTION DETAILS (IF APPLICABLE) IS DESIGNED TO MEET THE FOLLOWING STRUCTURAL REQUIREMENTS: 1 20 WIND ZONE(S)__________ ROOF LOAD(S)__________LBS. 0764L DRAWING TITLE NOTES: 1. RECEPT SHALL NOT BE INSTALLED WITHIN 30" OF TUB/SHOWER SPACE. 2. ELECTRICAL WALL PLATES SHALL NOT BE INSTALLED WITHIN 6" OF A RANGE OR COOKTOP. 3. THE MAXIMUM TRAVEL DISTANCE FROM ANY BEDROOM DOORWAY TO AN 33.1 LF. ENTRY DOOR IS ______ 4. ROOM TITLES INCLUDING (#) INDICATES SQUARE FOOTAGE HAS BEEN COMBINED FOR GLAZING/VENTING REQUIREMENTS. 5. OPT REMOTE HEATING/COOLING APPLIANCE AND THERMOSTAT TO BE SUPPLIED AND INSTALLED BY OTHERS. OMIT FURNACE BRANCH CIRCUIT & RECEPTACLE OUTLETS. MODEL NO. OPT FLOOR PLAN DRAWN BY: Mary S. #13 DATE: Conforms to HUD MHCSS 8/15/06 08/14/06 SHT REV FP.3 341SH0764L B v.1.0 L E G E N D REQ'D W/ OPT BUFFET RAISE CAB 4" D 2 11'-0" RECEPTACLE C OPT 48 6 T 2 OPT SA SWITCH 5 5 T THERMOSTAT HEAT TAPE RECEPT ON UNDERSIDE OF FLOOR 9 SMOKE ALARM 14 SMOKE ALARM 5 W/ HUSH BUTTON LINEN OPT SHELF OR OPT O'HD W/ SHLF OPT LIGHT FIXTURE 30 6 7 44 17 15 STUDY 148.2 sqf 7 RECESSED LIGHT 5 OPT OPT RA EXHAUST FAN FA 6 FLUORESCENT LIGHT 5 BATH 3 PANEL BOX OPT SA OPT 16 WH 6 0 UTILITY 5 30 368 5 BATH 2 5 ENTRY 30 6 44 30 LAV B 14"RETURN AIR RA HALL 5 A4053VS AIR SUPPLY SA 44 6 SOLAR TUBE ST EGRESS W/ RAG 30 GFI RAG 19 OPT. VINYL WINDOW SIZE: V4053SH OPT. STUDY FLOOR REGISTER #13 OPT. BATH #3 RETURN AIR GRILLE OVERHEAD REGISTER A 11'-0" FAN W/ LIGHT WALL-MOUNTED REGISTER Conforms to HUD MHCSS 8/15/06 CROSS-OVER LOCATION X SUPPORT POST SHEARWALL WILLACOOCHEE 34 PRODUCT NAME SPRING HILL MODEL NO. 0764L DRAWING TITLE FLOOR PLAN OPTIONS DRAWN BY: Mary S. DATE: 08/14/06 SHT REV FPO.1 341SH0764L B v.1.0 L E G E N D VTR 3 WAY ELL LTTY AUTO VENT ST 45 o TUB WSHR SAN TEE ST 45 ST o C/O LAV W.C. ST 90° ELL 45 o WSHR ST C/O 1 1/2" PIPING 45 OPT BATH #3 VTR o 2" PIPING 3" PIPING * * INDICATES OPTIONAL SHIP LOOSE PIPE AND ATTACHED FITTINGS. VTR ST SINK C/O ST LAV * TO EXISTING 45 OUTLET o W.C. TUB TO EXISTING SINK * SHWR W.C. ST 45 ST o 45 LAV ST 45 * OUTLET * VER O X o ST WILLACOOCHEE 34 * PRODUCT NAME SPRING HILL * MODEL NO. 0764L o DRAWING TITLE PLUMBING DRAIN ST 45 TUB 45 45 o o DRAWN BY: #03 o ST C/O LAV Conforms to HUD MHCSS 5/17/06 DAN N. DATE: 05/16/06 SHT REV PLD.1 341SH0764L A v.1.0 L E G E N D WSHR W/H TEE W.C. 90° ELL LAV TUB WSHR INLET 1/2" PIPING W/H 3/4" PIPING INLET WSHR TO EXISTING FOR PEX PIPING, SEE ENG. PG. 35-01-0003 W/H OPT BATH #3 LAV O X- V ER W.C. TUB SINK LAV SHWR X V -O ER W.C. OPT D/W TUB SINK LAV TUB WILLACOOCHEE 34 SHWR PRODUCT NAME LAV LAV SPRING HILL TUB WSHR MODEL NO. 0764L LAV COLD WATER PLUMBING W/H DRAWING TITLE TUB TO EXISTING LAV HOT WATER PLUMBING OPT BATH #3 APPROVED PFS Corporation Madison WI – 13 3/2/06 HUD Manufactured Home Construction & Safety Standard PLUMBING WATER DRAWN BY: SABRINA R. DATE: 03/02/06 SHT REV PLW.1 341SH0764L v.1.0 L E G E N D TEE 90° ELL FURN (70M BTUH) 1/2" PIPING W/H (30M BTUH) 3/4" PIPING 1" PIPING NOTES: SYSTEM COMPLIANCE WITH FEDERAL MOBILE HOME STANDARD IS PROVEN BY: 1. CERTIFIED TEST NO. N/A FOR N/A INLET 2. SECT.280.705(D) 40'COLUMN LENGTH FOR ENTIRE SYSTEM WILLACOOCHEE 34 PRODUCT NAME SPRING HILL MODEL NO. F/S RANGE (55M BTUH) 0764L DRAWING TITLE APPROVED PFS Corporation Madison WI – 13 3/2/06 HUD Manufactured Home Construction & Safety Standard PLUMBING GAS OPTIONS DRAWN BY: SABRINA R. DATE: 03/02/06 SHT REV PLGO.1 341SH0764L v.1.0 L E G E N D DIFFUSER RECTANGULAR MIXER APPROVED PFS Corporation Madison WI – 13 TRIANGULAR MIXER 3/2/06 RETURN AIR GRILLE HUD Manufactured Home Construction & Safety Standard SUPPLY COLLAR 5 FLEX DUCT/DIAM NOTE: DUCT SYSTEM TO BE INSTALLED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. SEE HVAC CALCS FOR MAX. A/C CAPACITY WILLACOOCHEE 34 PRODUCT NAME SPRING HILL MODEL NO. 0764L DRAWING TITLE HVAC OVERHEAD CALCS DRAWN BY: SABRINA R. DATE: 03/02/06 SHT REV DCO.1 341SH0764L v.1.0 L E G E N D DIFFUSER RECTANGULAR MIXER TRIANGULAR MIXER RETURN AIR GRILLE SUPPLY COLLAR 5 FLEX DUCT/DIAM NOTE: DUCT SYSTEM TO BE INSTALLED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. SEE HVAC CALCS FOR MAX. A/C CAPACITY WILLACOOCHEE 34 PRODUCT NAME SPRING HILL MODEL NO. 0764L DRAWING TITLE APPROVED PFS Corporation Madison WI – 13 NOTES: 1. THIS HVAC SYSTEM MAY BE USED IN LIEU OF STANDARD HVAC SYSTEM. 2. REMOTE HEATING/COOLING APPLIANCE AND THERMOSTAT TO BE SUPPLIED AND INSTALLED BY OTHERS. 3/2/06 HUD Manufactured Home Construction & Safety Standard HVAC OVERHEAD DRAWN BY: SABRINA R. DATE: 03/02/06 SHT REV LSO.1 341SH0764L v.1.0 L E G E N D DIFFUSER RECTANGULAR MIXER TRIANGULAR MIXER RETURN AIR GRILLE SUPPLY COLLAR 5 FLEX DUCT/DIAM NOTE: DUCT SYSTEM TO BE INSTALLED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. SEE HVAC CALCS FOR MAX. A/C CAPACITY APPROVED PFS Corporation Madison WI – 13 3/2/06 HUD Manufactured Home Construction & Safety Standard WILLACOOCHEE 34 PRODUCT NAME SPRING HILL MODEL NO. 0764L DRAWING TITLE HVAC OVERHEAD DRAWN BY: SABRINA R. NOTES: DATE: 03/02/06 1. THIS HVAC SYSTEM MAY BE USED IN LIEU OF STANDARD HVAC SYSTEM. SHT 2. REMOTE HEATING/COOLING APPLIANCE AND THERMOSTAT TO BE SUPPLIED AND INSTALLED BY OTHERS. REV LSO.2 341SH0764L