Transcript
16.1
Commercial Networking: Optical Fiber
Table of Contents
16
Commercial Networking — Optical Fiber Introduction Optical Fiber Connectivity Products FiberExpress Connectors Pre-Connectorized Assemblies FiberExpress Secure/Keyed LC System FiberExpress Manager FiberExpress Patch Panels FiberExpress Patch Panels Accessories FiberExpress Outlets Network Connectivity Products Optical Fiber Cables Fiber Cable Selection Guide Interconnect Cable — Simplex & Duplex Distribution Cable Breakout Style Cable Industrial Armored Cable Tactical Cable Ribbon Cable Single Jacket, All Dielectric Cable Double Jacket, Armored Cable Double Jacket, Heavy-Duty Cable Central Tube Cable Micro Loose Tube Breakout Style Cable TrayOptic® Heavy-Duty, All Dielectric Cable
Please refer to “Terms of Use of Master Catalog” on page 22.22
Page No.
16.2 16.4–16.17 16.4 16.6 16.9 16.11 16.12 16.14 16.15 16.17 16.18–16.34 16.18 16.19 16.20 16.22 16.24 16.25 16.26 16.27 16.29 16.30 16.31 16.33 16.34
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.2
Introduction
Belden IBDN FiberExpress Systems Optical fiber systems offer many benefits: high bandwidth and transmission speed, the potential for network growth, extended reach, fault tolerance, greater data security and support for Gigabit and multi-Gigabit protocols and networked applications. Beyond these traditional benefits, however, Belden offers the FiberExpress Solution, a complete end-to-end cabling system supporting both centralized and fiber-tothe-desk topologies, as well as backbone and campus cabling configurations. Our FiberExpress Solutions meet or exceed all applicable TIA/EIA, ISO/IEC and IEEE standards and offer: ■
Reduced design complexities
■
Greater deployment facility
■
Quick installation
■
Increased flexibility
■
Cost effective pricing
The FiberExpress Manager The FiberExpress Manager makes fiber management easier than ever before. Designed to streamline termination, connection and maintenance activities, the FiberExpress Manager uses a scalable, modular approach to adapt to a wide variety of situations. The total system provides extra high connection density while facilitating cable routing and patch cord management. The FiberExpress Manager is adaptable for almost all situations, traditional field termination or pre-terminated modules, which reduces design complexity and increases deployment efficiency. Extended Reach Optical Fiber Cables
Primary FiberExpress System Components Key components of the FiberExpress Systems are summarized below and are found on the catalog pages that follow. Optimax® Connectors Optimax Connectors are a revolutionary field-installable optical fiber connector. The unique design of the patented mechanical splice body of Optimax incorporates a factory mounted fiber stub and a pre-polished ceramic ferrule. This technology consistently provides a fast, secure and reliable LC, SC or ST Compatible optical fiber termination for multimode or single-mode cable. All critical steps are performed in the factory, ensuring a superior quality connection every time.
Extended Reach Optical Fiber Cables propel your network into the future of cable technology with our multimode FiberExpress FX300, FX600 or FX2000 series. These series were developed to meet the existing needs of networks at 1 Gb/s (Ethernet, 1000Base-SX and 1000Base-LX) and new networks at 10 Gb/s (Ethernet, 10GBase-S and 10GBase-LX4). These series offer better reach for laser-based systems. For 1 Gb/s Ethernet at 850 nm (VCSEL), the FX300 and FX600 series provide a range of 984 ft (300 m) and 1,968 ft (600 m), respectively. For 10 Gb/s Ethernet at 850 nm (VCSEL), the FX2000 series provide a range of 984 ft (300 m) for 10GBase-S where all of multimode series can offer a 984 ft (300 m) range at 1300 nm (laser) for 10GBase-LX4. All of this while assuring total compatibility with LED systems and FDDI fiber installation cables. Our single-mode cable offering enhances the options for longer distance support — up to 40 km — for any of the Gigabit Ethernet applications. The FiberExpress Bar The FiberExpress Bar is an extremely compact, modular and resilient linking panel. Resembling a power bar, it offers 6 or 12 fibers, pre-terminated with an SC, SC duplex, ST-compatible, LC, MT-RJ or FC connectors
and a cord terminated with a multi-fiber MPO connector — all of which are factory verified. The FiberExpress Bar can adapt to all kinds of properties or developments, and can serve as a consolidation or linking point. It’s available in both single-mode and multimode media. For the ultimate in quick, easy and reliable optical networking we also offer the FiberExpress Pre-connectorized System. Based on the concept of building blocks, the complete range of pre-terminated FiberExpress components bring flexibility to the design stage. The in-factory fabrication and verification of pre-terminated connections ensures the high-performance and highquality of the product. These products are “plug and go” and their deployment requires no specialized tools — you can deploy 12 fibers in the same amount of time it takes to connect a power cord to a standard electrical plug. This pre-terminated technology will help to preserve the initial investment by its ability to be re-deployed while always ensuring quality results.
Quality Installation and Service All Belden IBDN systems are designed, installed and field-tested by fully-trained and certified system contractors and integrators to further assure superior systems performance. They are also backed by a strict System Certification and Warranty Program.
System Certification and Warranty Program The Belden IBDN Certification Program is a rigorous process that ensures that your Belden IBDN ‘Certified’ System is composed of Belden IBDN components, designed and installed by a factory-trained Certified System Vendor. Belden IBDN ‘Certified’ Systems are supported by a series of warranties that surpass conventional product warranties. Certification adds important end-to-end system performance guarantees and ensures full compliance with cabling industry standard specifications — even after system installation (Installable Performance®). A 25-year Product Warranty and a Lifetime Application Assurance program accompany each Belden IBDN ‘Certified’ System installation. These warranty programs include coverage for both parts and labor.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.3
Fiber Channel Topology
FiberExpress Cables Distribution & Breakout Cable Series Multimode and Single-mode Interconnect Cable Series Multimode and Single-mode Loose Tube (Campus) Cable Series MM, SM, Composite MM/SM Ribbon Cable Series Multimode and Single-mode
Page No.
Fiber-to-the-Desk (FTTD) and Centralized Fiber
16.20– 16.23 16.19
●
16.27– 16.34 16.26
Fiber Backbone (In-Building)
Fiber Backbone (Campus)
FiberExpress Pre-Terminated Solutions*
●
● ●
●
●
●
●
●
Telecom Room 16.11 ●
●
●
●
●
●
●
●
●
●
●
●
●
Patch Cords in the Telecom Room and at the Work Area FiberExpress Patch Cords: 16.6 ● Multimode and Single-mode
●
●
●
Outlets at the Work Area MDVO® Multimedia Outlets 16.16 with MDVO Multimedia Modules MediaFlex® Outlets 16.15 with MediaFlex Multimedia Inserts FiberExpress Bar 16.8 Multimode and Single-mode (as MUTOA)
●
Cross-Connect Hardware in the FiberExpress Manager with FiberExpress Manager Connector Modules Multimode and Single-mode FiberExpress Rack Mount Patch Panel with Universal Adapter Strips Multimode and Single-mode FiberExpress Wall Mount Patch Panel with Universal Adapter Strips Multimode and Single-mode FiberExpress Bar: Multimode and Single-mode
Fiber Connectivity Optimax® Connectors Multimode and Single-mode Epoxy Field Mountable Connectors Multimode and Single-mode Fiber Pigtails Multimode and Single-mode
16.12
16.13
16.8
●
● ● ●
16.4
●
●
●
16.5
●
●
●
16.8
●
●
●
MM = Multimode • SM = Single-mode *FiberExpress Pre-terminated Solutions provide simple-to-install, high-performance fiber channels through custom length, high precision factory terminated cables and matching optical connectivity components.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
16 • Networking — Fiber
FiberExpress® System Matrix
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.4
FiberExpress Connectors Optimax® Field Installable Connectors and Installation Tool Kits
AX101982 Optimax LC Connector
Optimax Field Installable Connector The Optimax Connectors are reliable field installable optical fiber connectors that are easy to install. They do not require epoxy, curing or polishing. Their unique design incorporates a factory polished fiber stub in a splice mechanism which provides a fast, secure, and reliable termination on optical fiber cables. All critical steps are performed in the factory, ensuring a superior-quality connection every time. Only simple tools are required for installation, making Optimax a cost effective field termination. Optimax Connectors are high-quality LC, SC and ST Compatible connectors that use a ceramic ferrule with a physical contact (PC) polish for Multimode and super physical contact (SPC) polish for Single-mode that ensures the best possible mating of optical fibers. Connectors are available for 62.5 or 50/125 µm Multimode fiber and Single-mode fiber installations.
AX100029 with AX101794 Optimax SC Connector
Optimax Installation Tool Kit The Optimax Installation Tool Kit is packaged in a small convenient carrying case and includes an Optimax LC, SC and ST Compatible installation and training video, installation instructions and all the tools required to terminate 900 µm buffered optical fiber and jacketed optical fiber. The Optimax Installation Tool Kit has all the tools and supplies required to install both the Optimax LC, SC or ST Compatible Multimode and Single-mode connectors. Certain tool kit items can be purchased separately to accommodate installers already possessing basic optical fiber installation tools.
Description A0408835 with AX101793 Optimax ST Compatible Connector
AX100947 Optimax Tool Kit
Belden Part Number
FiberExpress Connectors Optimax Field Installable Connector LC 62.5 µm, Multimode* LC 50 µm, Multimode* LC Single-mode* SC 62.5 µm, Multimode* SC 50 µm, Multimode* SC Single-mode* ST Compatible 62.5 µm, Multimode* ST Compatible 50 µm, Multimode* ST Compatible Single-mode* LC Accessory Kit for jacketed fiber (2 mm boot and a crimp sleeve) SC Accessory Kit for jacketed fiber (3 mm boot, crimp sleeves, cord adapter) ST Accessory Kit for jacketed fiber (3 mm boot, crimp sleeves) Optimax Installation Tool Kit LC/SC/ST Compatible (includes installation tools, fiber cleaver, crimping tool, instruction manual, microscope, tweezers, alcohol wipes, marker, scissors, waste bottle, fiber stripper, cable stripper and Training Video) Basic (excludes fiber stripper & cleaver) Optimax LC Tool Kit Upgrade (includes LC installation tool, instructions manual, foam for the case) Optimax Individual Components Fiber Cleaver Installation Tool LC (does not include tool-clamp) Installation Tools ST Compatible and SC (includes tool-clamp) Microscope Refurbishing Materials (80 alcohol wipes and a black felt tip marker) Installation Instruction Manual, LC Installation Instruction Manual, SC Installation Instruction Manual, ST Compatible Installation & Training Video, CD (see literature ordering form on the web) Crimp Tool complete with die
AX101981 AX101982 AX101983 AX100029 AX101077 AX101792 A0408835 AX101075 AX101791 AX101984 AX101794 AX101793 AX100947
AX100949 AX102061
A0408829 AX102062 A0403634 AX100910 AX100951 AX102063 PX101318 PX101317 NOT0651 A0403641
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status. *For 900 µm buffered fiber only. For Optimax Single-mode termination on jacketed fiber, please use the appropriate Accessory Kit.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.5
FiberExpress Connectors Epoxy Field Installable Connectors
A0390851 Optical Fiber Field Installable Epoxy Connector, ST Compatible
Epoxy Field Installable Connector Epoxy Field Installable Connectors are available as Multimode and Single-mode ST Compatible and SC field installable connectors. They require heat-cured epoxy and polishing. Both types have a ceramic ferrule. Each connector comes complete with all the parts necessary for termination of tight buffered fibers as well as jacketed fibers. Parts include crimp sleeves, boots, cord adapter and dust cap.
Belden Part Number Description
Multimode
Single-mode
A0390851 AX100919 AX100929
AX101412 AX101411
FiberExpress Connectors Epoxy Field Installable Connector ST Compatible SC Simplex SC Duplex
16 • Networking — Fiber
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.6
Pre-Connectorized Assemblies FiberExpress Patch Cords
AX200057 Patch Cord Multimode SC Duplex (568SC)
FiberExpress Patch Cords FiberExpress Duplex Patch Cord Assemblies are of the highest quality available. They are assembled and 100% optically tested in our factory prior to shipment. All patch cords are built with high-quality connectors and cables which guarantees superior performance and excellent reliability.
Belden Part Number Description
Multimode, FX300, 62.5 µm
Multimode, FX600, 50 µm
Multimode, FX2000, 50 µm
Single-mode SPC
70102419 70102420 70102447 AX200056 AX200057 AX200058 AX200517 AX200518 AX200519 AX101122 AX101123 AX101125
AX200341 AX200459 AX200413 AX200084 AX200082 AX200280 AX200527 AX200528 AX200529 AX101139 AX101138 AX101137
AX200799 AX200795 AX200800 AX200603 AX200589 AX200624 AX200664 AX200665 AX200666 AX200801 AX200802 AX200803
AX200090 AX200091 AX200092 AX200094 AX200095 AX200096 AX200507 AX200508 AX200509 AX101157 AX101156 AX101155
AX200060 AX200699 AX200580 AX101133 AX101128
AX200196 AX200695 AX200581 AX101151 AX101143
AX200900 AX200809 AX200668 AX200810 AX200797
AX200421 AX200698 AX200667 AX101166 AX101161
70100390 70101714 AX200657 AX101366
AX200458 AX200192 AX200658 AX101367
AX200811 AX200653 AX200660 AX200812
AX200097 AX200098 AX200659 AX101368
FiberExpress Pre-Connectorized Assemblies Duplex Patch Cord ST-ST, 2 m (6 ft.) ST-ST, 3 m (10 ft.) ST-ST, 5 m (16 ft.) 568SC-568SC, 2 m (6 ft.) 568SC-568SC, 3 m (10 ft.) 568SC-568SC, 5 m (16 ft.) LC duplex-LC duplex, 2 m (6 ft.) LC duplex-LC duplex, 3 m (10 ft.) LC duplex-LC duplex, 5 m (16 ft.) MTRJ-MTRJ, 2 m (6 ft.) MTRJ-MTRJ, 3 m (10 ft.) MTRJ-MTRJ, 5 m (16 ft.) Hybrid Patch Cord 568SC-ST, 3 m (10 ft.) LC duplex-ST, 3 m (10 ft.) LC duplex-568SC, 3 m (10 ft.) MTRJ-ST, 3 m (10 ft.) MTRJ-568SC, 3 m (10 ft.) Single-ended (pigtails) ST-open, 2 m (6 ft.) SC-open, 2 m (6 ft.) LC-open, 2 m (6 ft.) MTRJ(m)-open, 3 m (10 ft.)
Also available as Simplex Patch Cords or custom assemblies, please contact Customer Service for more details. These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.7
FiberExpress Pre-Connectorized Assemblies Cable Assemblies
AX250105 MPO Cable Assembly
MPO Cable Assembly MPO Cable Assemblies are multi-fiber cables using single MPO connectors 6, 8 and 12-fiber that are used to interconnect pre-terminated devices such as FiberExpress Pre-terminated Modules and FiberExpress Bars. Depending on the application, MPO Cable Assemblies can use Ribbon Cables or Loose Tube cables. MPO cables are available in lengths of up to 500 meters with a pulling-eye for ease of deployment. Multi-fiber Cable Assembly
Multi-fiber Cable Assembly
Multi-fiber Cable Assemblies are factory-terminated fiber cables of various constructions (distribution, breakout or ribbon) using simplex, duplex or multi-fiber connectors. They are available in configurations from 2-fiber up to 144-fiber with various kinds of fan-out constructions, lengths and geometry to suit virtually any application. Belden Part Number Description
Multimode, FX300, 62.5 µm
Multimode, FX600, 50 µm
FiberExpress Pre-Connectorized Assemblies
900 µm Fan-out Assembly
1 pulling eye, OFNP, 12 fibers, 10 m (33 ft.) 1 pulling eye, OFNP, 12 fibers, 20 m (66 ft.) 1 pulling eye, OFNP, 12 fibers, 50 m (164 ft.) 1 pulling eye, OFNP, 12 fibers, 75 m (246 ft.) 1 pulling eye, OFNP, 12 fibers, 100 m (328 ft.)
AX250345 AX250376 AX250065 AX250066 AX250067
Multimode, FX2000, 50 µm
Single-mode
AX250457 AX250412 AX250387 AX250413 AX250458
AX250224 AX250106 AX250071 AX250072 AX250073
Also available in 6 or 8-fiber MPO Cable Assemblies, please contact Customer Service for more details.
Multi-fiber Cable Assembly, MPO(m)-ST Multimode FX300, 62.5 µm, 12 fibers NXC-RPML-PGPNNN-STPFBN-N-01.5 Multimode FX600, 50 µm, 12 fibers NXC-RPNL-PGPNNN-STPFBN-N-01.5 Multimode FX2000, 50 µm, 12 fibers NXC-RPFL-PGPNNN-STPFBN-N-01.5 Single-mode, 12 fibers NXC-RPSL-PGANNN-STSFBN-N-01.5 Multi-fiber Cable Assembly, MPO(m)-SC Multimode FX300, 62.5 µm, 12 fibers NXC-RPML-PGPNNN-SCPFBN-N-01.5 Multimode FX600, 50 µm, 12 fibers NXC-RPNL-PGPNNN-SCPFBN-N-01.5 Multimode FX2000, 50 µm, 12 fibers NXC-RPFL-PGPNNN-SCPFBN-N-01.5 Single-mode, 12 fibers NXC-RPSL-PGANNN-SCSFBN-N-01.5 Multi-fiber Cable Assembly, MPO(m)-LC Multimode, FX300, 62.5 µm, 12 fibers NXC-RPML-PGPNNN-LCPFBN-N-01.5 Multimode FX600, 50 µm, 12 fibers NXC-RPNL-PGPNNN-LCPFBN-N-01.5 Multimode FX2000, 50 µm, 12 fibers NXC-RPFL-PGPNNN-LCPFBN-N-01.5 Single-mode, 12 fibers NXC-RPSL-PGANNN-LCSFBN-N-01.5 Multi-fiber Cable Assembly, MPO(m)-MTRJ(m) Multimode FX300, 62.5 µm, 12 fibers NXC-RPML-PGPNNN-JBPFBN-N-01.5 Multimode FX600, 50 µm, 12 fibers NXC-RPNL-PGPNNN-JBPFBN-N-01.5 Multimode FX2000, 50 µm, 12 fibers NXC-RPFL-PGPNNN-JBPFBN-N-01.5 Single-mode, 12 fibers NXC-RPSL-PGANNN-JBSFBN-N-01.5 These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
16 • Networking — Fiber
MPO Cable Assembly, FOMC, MPO(f)-MPO(f) 1 pulling eye, OFNP, 12 fibers, 10 m (33 ft.) AX250021 1 pulling eye, OFNP, 12 fibers, 20 m (66 ft.) AX250105 1 pulling eye, OFNP, 12 fibers, 50 m (164 ft.) AX250349 1 pulling eye, OFNP, 12 fibers, 75 m (246 ft.) AX250060 1 pulling eye, OFNP, 12 fibers, 100 m (328 ft.) AX250061
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.8
FiberExpress Pre-Connectorized Assemblies FiberExpress Bar
AX250001 FiberExpress Bar 12ST
FiberExpress Bar The FiberExpress Bar consists of a custom length fiber cable with, at one end, a factory pre-terminated rugged mini patch panel and, at the other end, a factory installed multi-fiber MPO connector. The very compact fiber patch panel contains 6 or 12 factory-terminated and tested connectors in a variety of styles. The ruggedness of the FiberExpress Bar makes it an ideal candidate for disaster recovery, industrial applications and other fiber deployment in harsh environment. FiberExpress Bar Accessories The MPO Adapter is the sleeve that provides primary alignment and locking when connecting the two MPO connectors (male to female). It has a flange and a metal clip for panel mounting and it is included with each FiberExpress Bar (1m with male connector).
MX100154 FiberExpress MPO Adapter
The 19 in. Rack Mount Housing is a 1U metal panel that holds 1 FiberExpress Bar. It has a live hinge on the left-hand side and swings out giving access to the MPO connection and facilitate cable management and slack storage when used with the Slack Storage Tray. The Front Cover is a smoked Plexiglas cover that protects the fiber cords connected to the FiberExpress Bar. It has 2 push rivets for positive locking and easy handling. The Slack Storage Tray attaches to the back of the 19 in. Rack Mount Housing to facilitate cable management and slack storage. It has a storage capacity of 5 meters of 12-fiber ribbon cable. The Wall Mount Enclosure can contain one FiberExpress Bar. It is made of heavy gauge steel and has a locking cover. Belden Part Number Description
Multimode, FX300, 62.5 µm
Multimode, FX600, 50 µm
FiberExpress Pre-Connectorized Assemblies FiberExpress Bar 12 ST type, MPO (m), 1 m 6 SC duplex, MPO (m), 12 fibers, 1 m 6 MT-RJ, MPO (m), 12 fibers, 1 m 12 LC, MPO (m), 1 m 12 ST type, MPO (m), 1 m 6 SC duplex , MPO (m), 12 fibers, 1 m 6 MT-RJ, MPO (m), 12 fibers, 1 m 12 LC, MPO (m), 1 m
AX250001 AX250005 AX250178 AX250539
AX250052 AX250054 AX250179 AX250540
Multimode, FX2000, 50 µm
Single-mode
AX250459 AX250460 AX250461 AX250541
AX250009 AX250011 AX250180 AX250542
Also available for 6 fibers, please contact Customer Service for more details.
FiberExpress Bar Accessories MPO Adapter (6 or 12 fibers) included with each FiberExpress Bar (1 m - Male) 19 in. Rack Mount Housing for FiberExpress Bar, Gray 19 in. Rack Mount Housing for FiberExpress Bar, Black Front Cover for FiberExpress rack mount housing Slack Storage Tray for FiberExpress Bar, (capacity: 5 meters) including top cover, Gray Slack Storage Tray for FiberExpress Bar, (capacity: 5 meters) including top cover, Black Wall Mount Enclosure, can contain one bar, Black
MX100154 AX100331 AX100330 AX100332 AX100329 AX100328 AC200004
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.9
FiberExpress Secure/Keyed LC System Optimax Field Installable Connectors and Patch Cords & Pigtails
FiberExpress Secure/Keyed LC System
AX102197 Secure/Keyed LC Optimax
The FiberExpress Secure/Keyed LC System allows for physical segregation of networks segments in secure fiber cabling infrastructures. All Secure/Keyed LC products are available with 6 different keying options each carrying a different color to facilitate network administration. The keying detail inside the connector is totally tamper-resistant and cannot be re-produced inside a standard LC connector to violate the network security. All products comply with the FOCIS 10 standard and optical performance exceeds all industry standards for SFF connectors.
Secure/Keyed LC System
The Secure/Keyed LC Optimax field installable connectors are available in Multimode 50 µm laseroptimized and 62.5 µm fiber versions. They are high-quality connectors that use a ceramic ferrule with a physical contact (PC) polish for Multimode connectors. The Secure/Keyed LC Patch Cords and Pigtails are offered in Multimode 62.5 µm (FX300), 50/125 µm (FX600) and laser-optimized 50/125 µm (FX2000) for the most demanding network performance. Belden Part Number Description
K1, Red
K2, Green
K3, Yellow
K4, Black
K5, Orange
K6, Blue
AX102204 AX102198
AX102205 AX102199
AX102206 AX102200
AX102207 AX102201
AX102208 AX102202
FiberExpress Secure/Keyed LC System Secure/Keyed LC Optimax* Multimode 62.5 µm** Multimode 50 µm**
AX102203 AX102197
Secure/Keyed LC Duplex Patch Cord, KEYx-KEYx* 2 m (6 ft.), Multimode FX300, 62.5 µm AX201365 AX201366 2 m (6 ft.), Multimode FX600, 50 µm AX201383 AX201384 2 m (6 ft.), Multimode FX2000, 50 µm AX201401 AX201402 3 m (10 ft.), Multimode FX300, 62.5 µm AX201371 AX201372 3 m (10 ft.), Multimode FX600, 50 µm AX201389 AX201390 3 m (10 ft.), Multimode FX2000, 50 µm AX201407 AX201408 5 m (16 ft.), Multimode FX300, 62.5 µm AX201377 AX201378 5 m (16 ft.), Multimode FX600, 50 µm AX201395 AX201396 5 m (16 ft.), Multimode FX2000, 50 µm AX201413 AX201414 Secure/Keyed LC Duplex Hybrid Patch Cord, KEYx-LCD* 2 m (6 ft.), Multimode FX300, 62.5 µm AX201419 AX201420 2 m (6 ft.), Multimode FX600, 50 µm AX201437 AX201438 2 m (6 ft.), Multimode FX2000, 50 µm AX201455 AX201456 3 m (10 ft.), Multimode FX300, 62.5 µm AX201425 AX201426 3 m (10 ft.), Multimode FX600, 50 µm AX201443 AX201444 3 m (10 ft.), Multimode FX2000, 50 µm AX201461 AX201462 5 m (16 ft.), Multimode FX300, 62.5 µm AX201431 AX201432 5 m (16 ft.), Multimode FX600, 50 µm AX201449 AX201450 5 m (16 ft.), Multimode FX2000, 50 µm AX201467 AX201468 Secure/Keyed LC Duplex Hybrid Patch Cord, KEYx-SCD* 2 m (6 ft.), Multimode FX300, 62.5 µm AX201473 AX201474 2 m (6 ft.), Multimode FX600, 50 µm AX201491 AX201492 2 m (6 ft.), Multimode FX2000, 50 µm AX201509 AX201510 3 m (10 ft.), Multimode FX300, 62.5 µm AX201479 AX201480 3 m (10 ft.), Multimode FX600, 50 µm AX201497 AX201498 3 m (10 ft.), Multimode FX2000, 50 µm AX201515 AX201516 5 m (16 ft.), Multimode FX300, 62.5 µm AX201485 AX201486 5 m (16 ft.), Multimode FX600, 50 µm AX201503 AX201504 5 m (16 ft.), Multimode FX2000, 50 µm AX201521 AX201522 Secure/Keyed LC Pigtail, KEYx-open* 2 m (6 ft.), Multimode FX300, 62.5 µm AX201527 AX201528 2 m (6 ft.), Multimode FX600, 50 µm AX201533 AX201534 2 m (6 ft.), Multimode FX2000, 50 µm AX201539 AX201540
AX201367 AX201385 AX201403 AX201373 AX201391 AX201409 AX201379 AX201397 AX201415
AX201368 AX201386 AX201404 AX201374 AX201392 AX201410 AX201380 AX201398 AX201416
AX201369 AX201387 AX201405 AX201375 AX201393 AX201411 AX201381 AX201399 AX201417
AX201370 AX201388 AX201406 AX201376 AX201394 AX201412 AX201382 AX201400 AX201418
AX201421 AX201439 AX201457 AX201427 AX201445 AX201463 AX201433 AX201451 AX201469
AX201422 AX201440 AX201458 AX201428 AX201446 AX201464 AX201434 AX201452 AX201470
AX201423 AX201441 AX201459 AX201429 AX201447 AX201465 AX201435 AX201453 AX201471
AX201424 AX201442 AX201460 AX201430 AX201448 AX201466 AX201436 AX201454 AX201472
AX201475 AX201493 AX201511 AX201481 AX201499 AX201517 AX201487 AX201505 AX201523
AX201476 AX201494 AX201512 AX201482 AX201500 AX201518 AX201488 AX201506 AX201524
AX201477 AX201495 AX201513 AX201483 AX201501 AX201519 AX201489 AX201507 AX201525
AX201478 AX201496 AX201514 AX201484 AX201502 AX201520 AX201490 AX201508 AX201526
AX201529 AX201535 AX201541
AX201530 AX201536 AX201542
AX201531 AX201537 AX201543
AX201532 AX201538 AX201544
Other Patch Cord lengths and configurations may be available, please contact Customer Service for more details. These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.* Patent Pending.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
16 • Networking — Fiber
**For 900 µm buffered fiber only. The same accessory kit (AX101984) is used for 2 mm jacketed cable connector termination as for our regular Optimax LC offering.
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.10
FiberExpress Secure/Keyed LC System Adapter Modules, Adapter Strips and FiberExpress Manager Modules
FiberExpress Secure/Keyed LC System
AX102098 Secure/Keyed LC Adapter Module
The FiberExpress Secure/Keyed LC System allows for physical segregation of networks segments in secure fiber cabling infrastructures. All Secure/Keyed LC products are available with 6 different keying options each carrying a different color to facilitate network administration. The keying detail inside the connector is totally tamper-resistant and cannot be re-produced inside a standard LC connector to violate the network security. All products comply with the FOCIS 10 standard and optical performance exceeds all industry standards for SFF connectors. The Secure/Keyed LC Adapter Modules and Adapter Strips can be used in all mounting hardware for workstation area, Consolidation Point or Telecom Room applications.
AX102124 Secure/Keyed LC Adapter Strip
The Secure/Keyed LC FiberExpress Manager Modules can be used in 19 and 23 inch FiberExpress Manager Shelves to provide a high-density management system of up to 1920 terminated fibers per rack.
AX102114 Secure/Keyed LC FiberExpress Manager Module
Belden Part Number Description
K1, Red
K2, Green
K3, Yellow
K4, Black
K5, Orange
K6, Blue
AX102090 AX102096 AX102102 AX102108
AX102091 AX102097 AX102103 AX102109
AX102092 AX102098 AX102104 AX102110
AX102093 AX102099 AX102105 AX102111
AX102094 AX102100 AX102106 AX102112
AX102120 AX102126
AX102121 AX102127
AX102122 AX102128
AX102123 AX102129
AX102124 AX102130
AX102114 AX102311
AX102115 AX102312
AX102116 AX102313
AX102117 AX102314
AX102118 AX102315
FiberExpress Secure/Keyed LC System Secure/Keyed LC Adapter Module* Gray holder AX102089 Almond holder AX102095 White holder AX102101 Black holder AX102107 Secure/Keyed LC FiberExpress Adapter Strip* 12 fibers AX102119 24 fibers AX102125 Secure/Keyed LC FiberExpress Manager Module* 12 fibers AX102113 24 fibers AX102310 * Patent Pending. These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.11
FiberExpress Manager Rack Components and Modules
AX100934 FiberExpress Manager Shelf
FiberExpress Manager Shelf FiberExpress modules are rack-mounted using FiberExpress Manager Shelves. The shelves provide the total system with extra high connection density while facilitating cable routing and patch cord management. For 19- or 23-inch rack: 19 in. shelf holds up to 12 modules; 23 in. shelf holds up to 16 modules. FiberExpress Manager 1U
AX101943 FiberExpress Manager 1U Rack Mount Patch Panel
The FiberExpress Manager 1U Rack Mount Patch Panel is a low-cost, compact assembly designed for interconnection or splicing of optical fiber cables, using up to three FiberExpress Manager Modules. The low-profile design minimizes rack space to only 45 mm (1.75 in.). An optional FiberExpress Manager 1U Cable Management Accessory is also available. FiberExpress Manager Connector Module The Connector Module is the basic building block of the FiberExpress Manager. It is designed with a unique release mechanism that allows it to slide from the shelf like a PC card, easing management of patch cords.
AX102032 FiberExpress Manager 1U Cable Management Accessory
Belden Part Number Description
Gray
Black
AX100934 AX101084 AX101944 AX102033
AX100935 AX101085 AX101943 AX102032
AX101525 Connector Module Pre-terminated MPO-MT-RJ
FiberExpress Manager Shelf, 23 in., 10.9 kg (24 lb) Shelf, 19 in., 8.2 kg (18 lb) 1U, Rack Mount Patch Panel, 19 in., 5 kg (11 lb) 1U, Cable Management Accessory, 19 in., 1 kg (2 lb)
Belden Part Number Description
ST Type
SC Simplex
SC Duplex
SC Duplex (ST in)
LC
AX101120 AX101119
AX101528 AX101527
FC
FiberExpress Manager FiberExpress Manager Connector Module Metal Sleeve, Multimode, 6 fibers AX101089 Zirconia Ceramic, Single-mode, 6 fibers AX100936 Metal Sleeve, Multimode, 12 fibers AX101187 Zirconia Ceramic, Single-mode, 12 fibers AX101186 Zirconia Ceramic, Single-mode, 12 UPC pigtails Metal Sleeve, Multimode, 24 fibers Zirconia Ceramic, Single-mode, 24 fibers Zirconia Ceramic, Single-mode/Multimode, 6 fibers MPO(m)-ST type, 12 pre-terminated MPO(m)-SC Duplex, 12 pre-terminated MPO(m)-MT-RJ(m), 12 pre-terminated MPO(m)-LC, 12 pre-terminated MPO(m)-LC, 24 pre-terminated MT-RJ, Beige, Multimode, 12 fibers MT-RJ, Blue, Single-mode, 12 fibers
AX100943
AX101092 AX100944 AX101714 AX101713 AX101715
AX102306 AX102305 AX100937
Multimode 62.5 µm
Multimode 50 µm
Single-mode
AX101189 AX101091 AX101525 AX101530 AX102309
AX101190 AX101114 AX101526 AX101531 AX102308
AX101188 AX101090 AX101524 AX101529 AX102307
—
AX101096 AX101581
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
16 • Networking — Fiber
FiberExpress Manager
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.12
FiberExpress Patch Panels Rack Mount Patch Panels
AX100041 FiberExpress, 12/24 Port (1U) Rack Mount Patch Panel
FiberExpress Rack Mount Patch Panel 1U and 2U The FiberExpress 1U and 2U Rack Mount Patch Panels are equipped with a special hinge that allows easy access to the rear of the patch panel without disturbing the optical fiber cable. A specially designed front panel allows connector protection and easy routing of optical fiber patch cords. The FiberExpress Rack Mount Patch Panels are also compatible with our 203 mm (8 in.) Splice Organizer Trays. This allows the optical fiber cable to be either terminated with fiber single-ended patch cords or field-installable connectors. The patch panels can be used with ST Compatible, SC, 568SC, FC, LC or MT-RJ adapters strips (ordered separately).
AX100069 FiberExpress, 24/48 Port (2U) Rack Mount Patch Panel
The FiberExpress 1U Rack Mount Patch Panel is a low-cost, compact assembly designed for interconnection or splicing of optical fiber cables, from 12 up to 48 fibers if MT-RJ or LC double density adapter strips are used. The low-profile design minimizes rack space to only 45 mm (1.75 in.). An optional smoked Plexiglass front cover is also available. The FiberExpress 2U Rack Mount Patch Panel offers a high fiber capacity, 96 fibers if using double density MT-RJ or LC adapter strips. The FiberExpress 2U comes equipped with a smoked Plexiglass front cover that protects fiber connections while allowing for quick visual inspection. FiberExpress Rack Mount Patch Panel 3U
AX100078 FiberExpress (3U) Rack Mount Patch Panel
The FiberExpress 3U Rack Mount Patch Panel can accommodate up to 96 optical fiber connections using MT-RJ or LC connectors. The connector panel is mounted on a sliding drawer for easy access to the back side (cable side) of the panel. The FiberExpress 3U Rack Mount Patch Panel can be used with either optical fiber single-ended patch cords or field-installable connectors. If optical single-ended patch cords are to be used, organizer trays are easily accessible via the removable front access pull-out drawer. (Trays must be ordered separately.) The FiberExpress 3U Rack Mount Patch Panel is a compact cross-connect assembly for the termination of optical fiber cables. The low-profile design minimizes required rack space to 127 mm (5 in.). It is compatible with ST Compatible, SC, 568SC, MT-RJ, LC and FC adapters strips (ordered separately). FiberExpress Rack Mount Patch Panel 4U
AX100115 FiberExpress, 48/96 Port (4U) Rack Mount Patch Panel
The FiberExpress 4U Rack Mount Patch Panel is an economical solution for the protection of optical fiber terminations and splices, up to 192 optical fibers if using MT-RJ or LC connectors. The connector panel, accepting the Universal Adapter Strips, is located inside the enclosure and swings out (left or right) to give easy access to the cable and splices. The FiberExpress 4U Rack Mount Patch Panel is a compact Cross-Connect enclosure for the crossconnection, interconnection or splicing of optical fiber cables. The low-profile design minimizes required rack space to 178 mm (7 in.). It can be used with ST Compatible, SC, 568SC, MT-RJ, LC and FC adapters strips (ordered separately).
Description
Belden Part Number
FiberExpress Patch Panels FiberExpress Gray Black FiberExpress Gray Black FiberExpress Gray Black FiberExpress Gray Black
Rack Mount Patch Panel 1U* AX100042 AX100041 Rack Mount Patch Panel 2U* AX100069 AX100068 Rack Mount Patch Panel 3U AX100078 AX100077 Rack Mount Patch Panel 4U AX100115 AX100116
If Single-ended patch cords are to be spliced to the fiber cable, don’t forget to order Splice Organizer Trays or Kits. Both these, and the Universal Adapter Strips can be ordered in the FiberExpress Accessories section. *IMPORTANT: The FiberExpress 1U accepts two (2) 203 mm (8 in.) splice trays. The 2U accepts four (4) 203 mm (8 in.) splice trays. These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.13
FiberExpress Patch Panels Rack Mount Accessories and Wall Mount Patch Panels
AX101800 127 mm (5 in.) Universal Offset Bracket Kit, for 19 in. and 23 in. Racks 1U
FiberExpress Rack Mount Patch Panels 1U and 2U Accessories The accessories provide additional panel mounting flexibility for racks, cabinets and cable entry.
Description
Belden Part Number
FiberExpress Patch Panels
AX101802 23 in. Rack Universal Extension Bracket for 1U and 2U
AX100047 Right Side Cable Entry Bracket for 1U
Rack Mount Accessories (1U and 2U) 127 mm (5 in.) Universal Offset Bracket Kit: for 19 in. and 23 in. racks (1U), Black for 19 in. and 23 in. racks (1U), Gray for 19 in. and 23 in. racks (2U), Black for 19 in. and 23 in. racks (2U), Gray 23 in. Universal extension bracket, Black 23 in. Universal extension bracket, Gray Right side cable entry bracket (1U), Black Right side cable entry bracket (1U), Gray Right side cable entry bracket (2U), Black Right side cable entry bracket (2U), Gray Front Cover (1U), Smoked Plexiglass
AX101799 AX101800 AX101797 AX101798 AX101801 AX101802 AX100046 AX100047 AX100073 AX100074 AX100045
FiberExpress Wall Mount Patch Panel
AX100045 Front Cover for 1U
Using the FiberExpress Universal Adapter Strips (ordered separately), the Wall Mount Patch Panels allow for flexible and customized patch panel design. They are compatible with most industry standard connections: ST Compatible, SC, 568SC, MT-RJ, LC and FC. Available in gray and black, the FiberExpress Wall Mount Patch Panels have an ergonomic design, rugged construction and compact assemblies to effectively protect your optical fiber terminations and splices.
Description
Belden Part Number
FiberExpress Patch Panels
AX100543 Large Wall Mount
Wall Mount Small, Gray Small, Black Medium, Gray Medium, Black Large, Gray Large, Black
AX100496 AX100495 AX100541 AX100540 AX100543 AX100542
If optical Single-ended patch cords are to be spliced to the fiber cable, don’t forget to order Splice Organizer Trays or Kits in FiberExpress Accessories section. Universal Adapter Strips can be ordered in FiberExpress Patch Panels section. These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
AX100541 Medium Wall Mount
AX100495 Small Wall Mount
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
16 • Networking — Fiber
The FiberExpress Wall Mount Patch Panel Series is an economical solution for the protection of optical fiber terminations and splices in hostile environments.
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.14
FiberExpress Patch Panels Accessories Universal Optical Fiber Adapter Strips and Accessories
AX101729 Adapters loaded with 6 LC Duplex
Optical Fiber Adapter Strips Universal Optical Fiber Adapter Strips are pre-loaded with six (single density) or 12 (double density) adapter sleeves. Two types of adapter sleeves are available: Phosphor Bronze and Zirconia Ceramic. Adapter sleeves are used as the connecting interface between two optical fiber connectors. A Blank adapter strip is also available and can be used with any FiberExpress Patch Panel to fill in unused adapter strip openings.
AX100094 Adapters loaded with 3 SC Duplex
Optical Fiber Accessories The Field Breakout Kit is designed to attach to one tube of a loose-tube cable. Each kit has either six or twelve 900 µm tubes that hold each of the coated fibers. For each end of the cable, one kit is needed for every tube. For example, a 12-fiber 62.5 µm cable contains two 6-fiber tubes. This cable would require four kits, two for each end. Optical Fiber Splice Organizer Kits provide the accessories necessary for installing the FiberExpress Fiber Patch Panels, as well as other fiber terminals that accommodate the standard Belden organizer tray. The Flex Kit contains tubes and manifolds designed to split cables into individual fiber strands, and is suitable for 6 fibers up to 12 fibers. It is necessary for use with loose tube cables or when the fiber cable count does not match the number of connections in the FiberExpress Manager Connector Module. The Flex Kit tubes help to maintain proper fiber bend radius. One kit is required per 12 modules (one 19 in. shelf).
AX100066 Blank Strip
A Splice Holder Kit can be used to hold fusion or mechanical splices. Each splice holder can handle up to 6 splices. AX101100 Field Breakout Kit Belden Part Number Description
Phosphor Bronze, Multimode
Zirconia Ceramic, Single-mode
FiberExpress Optical Fiber Adapter Strips
A0649869 Optical Fiber Splice Organizer Kits and Trays
Single Density, Black Loaded with 6 ST Compatible Adapters AX100088 Loaded with 3 SC Duplex Adapters AX100094 Loaded with 6 SC Simplex Adapters AX100092 Loaded with 6 FC Adapters AX100090 Loaded with 6 LC Duplex Adapters AX101729 MT-RJ, loaded with 6 MT-RJ, Multimode/Single-mode Double Density, Black Loaded with 12 ST Compatible Adapters AX100080 Loaded with 6 SC Duplex Adapters AX100098 Loaded with 12 SC Simplex Adapters AX100084 Loaded with 12 FC Adapters AX100082 Loaded with 12 LC Duplex Adapters AX101741 MT-RJ, loaded with 12 MT-RJ, Multimode/Single-mode Blank Strip Black
AX100534 AX101407 AX100538 AX100536 AX101731 AX101115 AX100528 AX101409 AX100532 AX100530 AX101743 AX101117 AX100066
FiberExpress Accessories
AX100945 Flex Kit
AX101098 Splice Holder Kit
Optical Fiber Field Breakout Kit 6 fibers, 1/pack 12 fibers, 1/pack Optical Fiber Splice Organizer Kit Splice kit, tray, 203 mm (8 in.) Splice kit, tray, 305 mm (12 in.) Optical Fiber Splice Tray Fusion, 203 mm (8 in.) Fusion, 305 mm (12 in.) Universal (mechanical or fusion), 203 mm (8 in.) Universal (mechanical or fusion), 305 mm (12 in.) Tray cover, 203 mm (8 in.) Tray cover, 305 mm (12 in.) Flex Kit Splice Holder Kit
AX101100 AX101101 A0649869 A0318904 A0335015 A0316446 AX100079 A0394328 A0394331 A0394330 AX100945 AX101098
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.15
FiberExpress Outlets MediaFlex Plates and Inserts
AX101869 MediaFlex Plate, Double Gang
MediaFlex Plate MediaFlex Plates are one part of the comprehensive line of plates and inserts that snap together to create a full line of modular workstation outlets. MediaFlex Plates can be mounted over standard NEMA type outlet boxes and rings to provide support for a variety of MediaFlex Adapters and Inserts. The fully modular construction combined with the front access design provides extensive configuration flexibility for current and future network needs. MediaFlex Plates are available in Single Gang and Double Gang configurations.
AX101874 MediaFlex Adapter Box, Double Gang
The Double Gang faceplate comes with a stand-off ring included in the package. This ring allows for easy mounting with virtually any industry electrical box or mud/adapter rings, therefore providing added installation flexibility. Each plate has the capacity of up to 6 ports per Single Gang and 12 ports per Double Gang. MediaFlex Adapter Box MediaFlex Surface Adapter Boxes are one part of the comprehensive line of plates and inserts that snap together to create a full line of modular workstation outlets.
AX101756 MediaFlex MDVO (style) Insert, 2-port, Angled
MediaFlex Surface Adapter Boxes can be mounted over standard NEMA type outlet boxes and rings to provide support for the MediaFlex plates. The MediaFlex Surface Adapter Boxes are available as a Double Gang configuration. The Double Gang box allows more room for cable management and bend radius control. MediaFlex MDVO (style) Insert
MediaFlex Multimedia Insert AX101937 MediaFlex SC Duplex Insert, Angled
MediaFlex Multimedia Inserts provide optimum flexibility in configuring multimedia workstation outlets that respond to any present or future network needs. MediaFlex Multimedia Inserts along with other MediaFlex Inserts allow for easy configuration of outlets. All inserts are front loaded and easily snapped in and out of the MediaFlex Plates for easy installation and maintenance. MediaFlex Multimedia Inserts are available in Angled versions only in order to allow for proper management of cable bend radius. The inserts are three units high, therefore two inserts are required to fully populate a Single Gang faceplate and four inserts will fully populate a Double Gang faceplate.
Belden Part Number Description
Gray
Almond
Elec. White
Black
White
Ivory
AX101745 AX101869
AX101746 AX101870
AX101747 AX101871
AX101748 AX101872
AX102608 AX102609
AX102569 AX102570
AX102480 AX101873
AX102481 AX101874
AX102482 AX101875
AX102483 AX101876
AX102484 AX102610
AX102485 AX102571
AX101749 AX101753
AX101750 AX101754
AX101751 AX101755
AX101752 AX101756
AX102612 AX102613
AX102572 AX102573
AX101935 AX101939
AX101936 AX101940
AX101937 AX101941
AX101938 AX101942
AX102619 AX102620
AX102649 AX102650
FiberExpress Outlets MediaFlex Plate Single Gang Double Gang MediaFlex Adapter Box Single Gang Double Gang MediaFlex MDVO (style) Insert 2-port, Flush, bag of 10 units 2-port, Angled, bag of 10 units MediaFlex SC Duplex SC Duplex Single-mode SC Duplex Multimode
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
16 • Networking — Fiber
MediaFlex MDVO-style Inserts are available in a 2-port configuration in both Flush and Angled versions. They are compatible with all GigaFlex and MDVO Modules (EZ-MDVO and Multimedia). The inserts are two units high for the flush version and three units high for the angled version. Therefore three flush inserts or two angled inserts are required to fully populate a Single Gang MediaFlex Plate.
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.16
FiberExpress Outlets MDVO Multimedia Outlet Boxes & Modules and Multi-User Outlet Boxes
A0643205 MDVO Multimedia Outlet Box, shown here as terminated
MDVO Multimedia Outlet Box The MDVO Multimedia Outlet Box brings unique versatility for multimedia work area installations. The box design provides cable management and helps maintain cable bend radius. The outlet box’s low profile design and side-entry offers better protection for patch cords. The outlet box can accept up to six EZ-MDVO, GigaFlex or MDVO Multimedia Modules or three SC Duplex adapters. The MDVO Multimedia Outlet Box can be mounted directly on the wall or attached to standard electrical boxes. Included with the MDVO Multimedia box are three SC Duplex Mounting bezels and three MDVO Adapters. MDVO Multimedia Modules MDVO Multimedia Modules address audio/video and fiber applications. Fiber modules are available for LC Duplex, SC Simplex, ST Compatible multimode and MT-RJ multimode & single-mode connections. The SC Duplex Adapter is a fiber adapter sleeve with flanges that mounts into the SC Duplex mounting bezel (included in the MDVO Multimedia Outlet box). Audio/video modules are available for SVHS, RCA, BNC and Video F connections. Multi-User Outlet Box
A0407005 MDVO SC Fiber Module
The Multi-User Outlet Box is a versatile box that can be used in many different applications. The outlet box can accommodate up to 24 connections of any type, UTP, fiber or coax. The outlet box is ideal for use as a multi-user telecommunications assembly, or simply as a high-density multimedia telecommunications outlet. The Multi-User Outlet Box can also be used as a wall mounted patch panel in confined areas, such as shallow rooms and cabinets. Belden Part Number Description
A0649254 SC Duplex Adapter
Gray
Almond
White
Black
A0643206
A0643207
A0643208
AX102210 AX102211 AX102214 AX102215 A0407004 A0407005 A0649254 A0407008 A0407009 AX101467 AX101466
AX102212 AX102216 A0407006
FiberExpress Outlets MDVO Multimedia Outlet Box 6-port A0643205
Please note that SC Duplex adapters must be ordered separately (A0649254).
A0407010 MDVO ST Compatible Fiber Module
MDVO Multimedia Module LC Duplex Multimode LC Duplex Single-mode SC Simplex, Multimode, Blue insert SC Duplex Adapter, Multimode ST Compatible, Multimode MT-RJ, Multimode MT-RJ, Single-mode, Blue
AX102209 AX102213 A0407003 A0407007
A0407010
Custom multimedia connectors are also available, please contact Customer Service for more details.
AX101467 MDVO MT-RJ Fiber Module
Multi-User Outlet Box 24-port
AX100219
AX100220
AX100221
AX100222
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
AX100222 Multi-User Outlet Box, shown here with modules
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.17
Network Connectivity Products Media Converters, Transceivers & Hubs and Network Tester
Media Converters for Ethernet and Fast Ethernet
Media Converters
Media Converters enable the connection of dissimilar network cabling types, while maintaining the same network speed. A legacy Thinnet segment can be connected to a 10Base-T Hub or switch port with an AX-200 Converter or, link two different 10Base-T networks together over a multimode fiber optic link with a pair of AX-270s. Connect a legacy Thinnet segment over fiber with the AX-280 converter. The AX-5270 can be used for interbuilding links or attached to a fiber backbone. Transceivers and Ethernet Hubs The AX-50, 70 and 80 Transceivers enable the connection of a legacy AUI port to 10Base-T, Thinnet, or Fiber Optic media. The transceiver is powered from the host and requires no external power supply. The AX-509 Ethernet Hub has an AUI port which accepts UTP, Fiber Optic or BNC transceivers. Specified for use by many U.S. Government Agencies. Includes a 110v/12v power supply.
AX-1912 Media Converter Rack
Realtime 10/100 Base-TX Ethernet Network Test Unit The AX-110BT Realtime 10/100 Base-TX Ethernet Network Test Unit is a cost effective way to quickly determine a network's operating condition. Plug the unit's patch cord into the tester, then into any open RJ-45 jack in an office, cubicle or conference room. Immediately see if the jack is a live network node capable of either 100 Mb/s or 10 Mb/s. Next check patch cord continuity and polarity. Connect the downlink to a PC to check NIC card link, speed and full or half duplex capabilities. Connect the uplink to a hub or switch port to verify link and speed. AX050, 70 and 80 Transceivers and AX-509 Ethernet Hub Description
Belden Part Number
AX-110BT Realtime 10/100 Base-TX Ethernet Network Test Unit
Media Converter 10Base-T/10Base2, RJ-45 to BNC 10Base-T/10Base-FL, RJ-45 to ST-Compatible fiber connectors 10Base2/10Base-FL, BNC to ST-Compatible fiber connectors 100Base-TX/100Base-FX, SC-Compatible fiber connectors 100Base-TX/100Base-FX, ST-Compatible fiber connectors Media Converter Rack Holds up to 12 converters and multi lead power supplies, 19 in. rack-mount ready Power Supply, 4-lead 110v/12v, powers up to 4 converters Power Supply, 8-lead 110v/12v, powers up to 8 converters Transceivers and Ethernet Hubs UTP Transceiver, 10Base-T, AUI to RJ-45, side port UTP Transceiver, 10Base-T, AUI to RJ-45, rear port Fiber Transceiver, 10Base-FL, AUI to ST-Compatible Thinnet Transceiver, 10Base2, AUI to BNC Ethernet Hub with 8 RJ-45 10Base-T ports and 1 AUI port Network Tester Realtime 10/100 Base-TX Ethernet Network Test Unit
AX-200 AX-270 AX-280 AX-5270SC AX-5270ST AX-1912-MCR AX-270P4U AX-270P8U AX-50 AX-50R AX-70 AX-80 AX-509 AX-110BT
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
16 • Networking — Fiber
Network Connectivity Products
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.18
Cable Selection Guide Introduction
Customer Service
The Belden line of Optical Fiber Cables represents a new selection of the best optical fiber cable products offered by the consolidated resources of the Belden organization. The unmatched resources of Belden have now generated a complete line of indoor and outdoor cable products in tight buffered and loose tube constructions. This offering now expands the available applications for Belden optical fiber cable.
Most of our optical fiber cables are available from stock. Many of these are available off-the-shelf from distributors. If you have a new or unusual application, or you cannot find a optical fiber cable in this catalog section that meets your technical requirements, contact Technical Support at 1-800-BELDEN-1 for additional information.
Cable Selection Guide Color Code Charts Optical Fiber Selection Type
Multimode
Single-mode
Grade
6
Fiber Size (µ)
50/125
5
50/125
4 3 2 1▲ —
50/125 62.5/125 62.5/125 62.5/125 —
Jacket Color Chart Standards Compliance
exceeds TIA/EIA-568-B.3-1 ISO 11801 OM3 TIA/EIA-568-B.3-1 ISO 11801 OM3 TIA/EIA-568-B.3 TIA/EIA-568-B.3 TIA/EIA-568-B.3 FDDI grade† ITU G.652.c/d††
Link Length (m)
Data Rate (Gb)
500
10
300
10
600 1,000 550 — —
1 1 1 — —
Cable Type Loose Tube & Outside Plant Cables Industrial Tray Cables Tight Buffered Cables Grades 2,3,4 Grades 5,6 Single-mode
Jacket Color Black Orange Orange Aqua Yellow
Nonstandard jacket colors are available upon request.
Fiber Sub-unit Color Code Chart* Fiber/Tube No. 1 2 3 4 5 6
▲
Grade 1 fibers are available upon request. Used in most current cable plants, but not recommended for future installations, except as patch cordage †† Low water peak fiber with advantages for CWDM applications †
Color Blue Orange Green Brown Slate White
Fiber/Tube No. 7 8 9 10 11 12
Color Red Black Yellow Violet Rose Aqua
*Per EIA/TIA 598-A
Optical Specifications Grade: Glass Type:
Operating Wavelength (nm) Min. OFL1 Bandwidth (MHz-km) Min. Laser 2 Bandwidth (MHz-km) Max. Attenuation Loose Tube (dB/km) Max. Attenuation Tight Buffered 3 (dB/km) 100 Mb Fast Ethernet Min. Link Length (meters S/L4) 1 Gb Ethernet Min. Link Length (meters S/L4) 10 Gb Ethernet Min. Link Length (meters S/L4)
2
3
4
5
6
62.5/125µ
62.5/125µ
50/125µ
50/125µ
50/125µ
Single-mode Enhanced 6
850/1300 200/500 220/500 3.25/1.0 3.50/1.25 300/2000 300/550 35/300
850/1300 200/500 385/500 3.25/1.0 3.50/1.25 300/2000 500/1000 35/300
850/1300 500/500 510/500 3.0/1.0 3.50/1.25 300/2000 600/600 85/300
850/1300 1500/500 2000/500 3.0/1.0 3.50/1.25 300/2000 1000 5/600 300/300
850/1300 3000/500 4000/500 3.0/1.0 3.50/1.25 300/2000 1000 5/600 500/300
1310/1550 — — 0.40/0.30 0.80/0.50 —/5000 —/5000 —/10,000
1
4
2
OFL = Overfilled Launch Effective Modal Bandwidth, determined by RML or DMD performance specifications 3 Max. Attenuation for Tight Buffered, Ribbon, Micro-Loose Tube and Loose Tube Plenum Cables
5
S/L = Short wavelength (850 nm) / Long wavelength (1310 nm) >2000 meters for engineered links 6 Low water peak Single-Mode suitable for CWDM use complies with ITU G.652.c/d
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.19
Interconnect Cable — Simplex and Duplex Tight Buffer — Riser & Plenum Rated
Applications
Specifications
■ Patch panels
Temperature Range Storage Operating Crush Resistance (EIA-455-41) Impact Resistance (EIA-455-25) Cyclic Flexing (EIA-455-104) Min. Bend Radius Installation Long Term Optical Specifications
■ Workstation equipment connections ■ Horizontal distribution in open office environments Product Description Interconnect Cables are designed for low fiber-count premises environments. They are small and very flexible, making them ideal for confined spaces. Their aesthetic appearance makes these cables suitable for use in open office environments. Available in 1 or 2 fibers. One sub-unit is marked to permit easy identification of transmit and receive fibers. Length markings to facilitate installation. Jacket Material Tight Buffer Strength Member Color Code (Tight Buffer)
PVC PVC Aramid Yarn Per EIA/TIA 598-A, see page 10.2
Jacket Color Single-mode 62.5/125 µm 50/125 µm / 1 Gbe 50/125 µm / 10 Gbe
-40 to +70°C -20 to +70°C 200 N/cm 20 Impacts @ 1.0 N-m 2000 cycles, min. 15 x OD 10 x OD See page 10.2
Fiber Bundle Detail Jacket
2.9 mm (.114 in.)
Yellow Orange Orange Aqua
900 Micron Buffered Fiber
5.9 mm (.233 in.)
SIMPLEX
DUPLEX
Riser UL Type cUL Type Flame Resistance Plenum UL Type cUL Type Flame Resistance
No. of Fibers
OFNR OFN FT4 UL 1666 OFNP OFN FT6 NFPA 262
Belden Part Number 62.5 / 125µm Std. / 1 Gbe
16 • Networking — Fiber
Ratings
50 / 125µm Std. / 1 Gbe
50 / 125µm 10 Gbe – 300M
Outside Diameter Single-mode Enhanced
Weight
Max. Install Load
Inch
mm
Lbs./1000′′
kg/km
Lbs.
N
Interconnect Cable Series Riser (NEC/CEC OFNR/OFN FT4) 1 M97112 M9A001 2 M96915 M9A002 Plenum (NEC/CEC OFNP/OFN FT6) 1 M98086 M9A003 2 M96919 M9A004
M9C001 M9C002
M9W001 M9W002
0.114 0.11 x 0.23
2.9 2.9 x 5.9
6 12
9 18
90 180
400 801
M9C003 M9C004
M9W003 M9W004
0.114 0.11 x 0.23
2.9 2.9 x 5.9
6 13
9 19
90 180
400 801
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.20
Distribution Cable Tight Buffer — Indoor Riser, Plenum & LSZH Rated
Applications
Specifications
■ Low to high fiber count requirements
Temperature Range Storage Operating Crush Resistance (EIA-455-41) Impact Resistance (EIA-455-25) Cyclic Flexing (EIA-455-104) Min. Bend Radius Installation Long Term Optical Specifications
■ In-building backbone ■ Fiber-to-the-desk applications ■ Computer room Product Description Flexible thermoplastic jacket provides excellent handling characteristics. Fibers and cable sub-units are color coded for easy identification. Length markings in meters for easy determination of cable length. Full dielectric construction, no grounding required. For Riser offering, MSHA approved cables are available.
-40 to +80°C -20 to +70°C 2000 N/cm 2000 Impacts @ 1.6 N-m 2000 cycles, min. 15 x OD 10 x OD See page 10.2
Fiber Bundle Detail Outer Jacket
Jacket Material Riser & Non-unitized Plenum Unitized Plenum Low Smoke Zero Halogen Tight Buffer Riser & Plenum Low Smoke Zero Halogen Strength Member Color Code (Tight Buffer) Jacket Color Single-mode 62.5/125 µm 50/125 µm / 1 Gbe 50/125 µm / 10 Gbe
PVC PVDF LSZH PVC LSZH Aramid Yarn Per EIA/TIA 598-A, see page 10.2 Yellow Orange (Green for LSZH only) Orange Aqua
Overall Polyester Tape Barrier
Aramid Strength Member
Color Coded Jacket
Specified Fiber (Color Coded)
2 – 12 FIBERS
Upjacketed Central Strength Member
Bundles of up to 12 Fibers Each
>12 – 144 FIBERS
Ratings Riser UL Type cUL Type Flame Resistance Plenum UL Type cUL Type Flame Resistance Low Smoke Zero Halogen UL Type cUL Type Flame Resistance
OFNR OFN FT4 UL 1666 OFNP OFN FT6 NFPA 262 OFNR OFN FT4 UL 1666
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.21
Distribution Cable Tight Buffer — Indoor Riser, Plenum & LSZH Rated (continued)
No. of Fibers
Belden Part Number 62.5 / 125µm Std. / 1 Gbe
50 / 125µm Std. / 1 Gbe
50 / 125µm 10 Gbe – 300M
Outside Diameter Single-mode Enhanced
Weight
Max. Install Load
Inch
mm
Lbs./1000′′
kg/km
Lbs.
N
Riser (NEC/CEC OFNR/OFN FT4) 2 M9B037 M9A037 4 M9B038 M9A038 6 M9B039 M9A039 8 M9B040 M9A040 12 M9B042 M9A042 24 M9B601* M9A601* 24 M9B602 M9A602 36 M9B604 M9A604 48 M9B606 M9A606 72 M9B609 M9A609 96 M9B622 M9A622 144 M9B619 M9A619 Composite Riser Cables 6xSM/12x62.5 M96992 12xSM/12x62.5 M96963 6xSM/12x50 M96909 12xSM/12x50 M96908 Plenum (NEC/CEC OFNP/OFN FT6) 2 M9B043 M9A043 4 M9B044 M9A044 6 M9B045 M9A045 8 M9B046 M9A046 12 M9B048 M9A048 24 M9B611* M9A611* 24 M9B612 M9A612 36 M9B614 M9A614 48 M9B616 M9A616 72 M9B620 M9A620 96 M9B623 M9A623 144 M9B621 M9A621 Composite Plenum Cables 6xSM/6x62.5 M97174 6xSM/12x62.5 M97041 12xSM/12x62.5 M97219 6xSM/6x50 M97412 6xSM/12x50 M97411 12xSM/12x50 M96780 LSZH (NEC/CEC OFNR/OFN FT4) 2 M9B100 M9A100 4 M9B101 M9A101 6 M9B102 M9A102 8 M9B103 M9A103 12 M9B104 M9A104 16 M9B105 M9A105 24 M9B107 M9A107 36 M9B111 M9A111 48 M9B112 M9A112 72 M9B114 M9A114 96 M9B116 M9A116 144 M9B120 M9A120
M9C037 M9C038 M9C039 M9C040 M9C042 M9C601* M9C602 M9C604 M9C606 M9C609 M9C622 M9C619
M9W037 M9W038 M9W039 M9W040 M9W042 M9W601* M9W602 M9W604 M9W606 M9W609 M9W622 M9W619
0.184 0.200 0.220 0.235 0.255 0.325 0.496 0.644 0.627 0.750 0.895 0.964
4.67 5.08 5.59 5.97 6.48 8.26 12.60 16.36 15.93 19.10 22.70 24.49
13 16 19 22 27 42 83 137 131 195 290 314
19 24 28 33 40 63 124 204 195 290 432 467
180 195 270 270 300 390 960 1440 945 1350 1983 2745
801 867 1201 1201 1334 1735 4270 6405 4203 6005 8820 12210
M9C043 M9C044 M9C045 M9C046 M9C048 M9C611* M9C612 M9C614 M9C616 M9C620 M9C623 M9C621
M9W043 M9W044 M9W045 M9W046 M9W048 M9W611* M9W612 M9W614 M9W616 M9W620 M9W623 M9W621
0.184 0.174 0.190 0.222 0.225 0.330 0.493 0.594 0.599 0.754 0.904 1.047
4.67 4.42 4.83 5.64 5.72 8.38 12.52 15.09 15.21 19.15 22.96 26.59
14 13 16 19 22 40 89 134 131 197 268 365
21 19 24 28 33 60 132 199 195 293 399 543
180 195 270 270 300 390 1263 1913 1245 2093 2160 3645
801 867 1201 1201 1334 1735 5618 8509 5538 9310 9608 16213
M9C100 M9C101 M9C102 M9C103 M9C104 M9C105 M9C107 M9C111 M9C112 M9C114 M9C116 M9C120
M9W100 M9W101 M9W102 M9W103 M9W104 M9W105 M9W107 M9W111 M9W112 M9W114 M9W116 M9W120
0.184 0.200 0.220 0.235 0.255 0.347 0.386 0.798 0.835 0.883 0.973 1.087
4.67 5.08 5.59 5.97 6.48 8.80 9.80 20.00 21.20 22.40 24.70 27.60
15 17 21 24 29 43 54 214 237 270 364 384
22 25 31 36 43 63 79 313 347 395 532 561
180 195 270 270 300 315 450 1619 1619 1619 1619 1619
800 867 1201 1201 1334 1400 2000 7200 7200 7200 7200 7200
Construction for LSZH cables differs from the drawing. Alternative fiber counts are available. *Single jacket design.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
16 • Networking — Fiber
Distribution Cable Series
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.22
Breakout Style Cable Tight Buffer — Indoor Riser, Plenum & LSZH Rated
Applications
Specifications
■ Low to medium fiber count requirements
Temperature Range Storage Operating Crush Resistance (EIA-455-41) Impact Resistance (EIA-455-25) Cyclic Flexing (EIA-455-104) Min. Bend Radius Installation Long Term Optical Specifications
■ In-building backbone or horizontal deployment ■ Office wiring ■ Factory floor automation and harsh environment installations Product Description Full dielectric construction, no grounding required. Available with 2 to 36 fibers. Fiber subunits are color coded for easy identification. Length markings in meters for easy determination of cable length. For Riser offering, MSHA approved cables are available. Outer Jacket Material Riser & Plenum Plenum Low Smoke Zero Halogen Sub-unit Jacket Material Riser & Plenum Low Smoke Zero Halogen Tight Buffer Riser & Plenum Low Smoke Zero Halogen Strength Member Color Code (Tight Buffer) Jacket Color Single-mode 62.5/125 µm 50/125 µm / 1 Gbe 50/125 µm / 10 Gbe
PVC PVDF LSZH PVC LSZH PVC LSZH Aramid Yarn Per EIA/TIA 598-A, see page 10.2
-40 to +80°C -20 to +70°C 2000 N/cm 2000 Impacts @ 1.6 N-m 2000 cycles, min. 15 x OD 10 x OD See page 10.2
Fiber Bundle Detail Outer Jacket
Color Coded Thermoplastic Jacket
Aramid Strength Member 900 micron Tight Buffered Fiber
Central Strength Member
2.0 mm Sub-units
Yellow Orange (Green for LSZH only) Orange Aqua
Ratings Riser UL Type cUL Type Flame Resistance Plenum UL Type cUL Type Flame Resistance Low Smoke Zero Halogen UL Type cUL Type Flame Resistance
OFNR OFN FT4 UL 1666 OFNP OFN FT6 NFPA 262 OFNR OFN FT4 UL 1666
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.23
Breakout Style Cable Tight Buffer — Indoor Riser, Plenum & LSZH Rated (continued)
No. of Fibers
Belden Part Number 62.5 / 125µm Std. / 1 Gbe
50 / 125µm Std. / 1 Gbe
50 / 125µm 10 Gbe – 300M
Outside Diameter Single-mode Enhanced
Weight
Max. Install Load
Inch
mm
Lbs./1000′′
kg/km
Lbs.
N
Riser (NEC/CEC OFNR/OFN FT4) 2 M9B005 M9A005 4 M9B006 M9A006 6 M9B007 M9A007 8 M9B008 M9A008 10 M9B009 M9A009 12 M9B010 M9A010 18 M9B011 M9A011 24 M9B012 M9A012 36 M9B083 M9A083 Plenum (NEC/CEC OFNP/OFN FT6) 2 M9B013 M9A013 4 M9B014 M9A014 6 M9B015 M9A015 8 M9B016 M9A016 10 M9B017 M9A017 12 M9B018 M9A018 18 M9B019 M9A019 24 M9B020 M9A020 36 M9B082 M9A082 LSZH (NEC/CEC OFNR/OFN FT4) 2 M9B130 M9A130 4 M9B131 M9A131 6 M9B132 M9A132 8 M9B133 M9A133 10 M9B134 M9A134 12 M9B135 M9A135 18 M9B136 M9A136 24 M9B137 M9A137 36 M9B138 M9A138
M9C005 M9C006 M9C007 M9C008 M9C009 M9C010 M9C011 M9C012 M9C083
M9W005 M9W006 M9W007 M9W008 M9W009 M9W010 M9W011 M9W012 M9W083
0.260 0.321 0.358 0.405 0.455 0.514 0.520 0.590 0.680
6.60 8.15 9.09 10.29 11.56 13.06 13.21 14.99 17.27
24 35 54 69 86 110 104 135 168
36 52 80 103 128 164 155 201 250
180 345 543 600 600 600 600 600 600
801 1535 2415 2700 2700 2700 2700 2700 2700
M9C013 M9C014 M9C015 M9C016 M9C017 M9C018 M9C019 M9C020 M9C082
M9W013 M9W014 M9W015 M9W016 M9W017 M9W018 M9W019 M9W020 M9W082
0.230 0.263 0.309 0.336 0.385 0.391 0.456 0.544 0.612
5.84 6.68 7.85 8.53 9.78 9.93 11.58 13.82 15.54
20 30 41 55 73 65 89 117 154
30 45 61 82 109 97 132 174 229
180 345 465 600 600 600 600 600 600
801 1535 2068 2700 2700 2700 2700 2700 2700
M9C130 M9C131 M9C132 M9C133 M9C134 M9C135 M9C136 M9C137 M9C138
M9W130 M9W131 M9W132 M9W133 M9W134 M9W135 M9W136 M9W137 M9W138
0.290 0.351 0.358 0.405 0.455 0.514 0.520 0.590 0.680
7.37 8.92 9.09 10.29 11.56 13.06 13.21 14.99 17.27
39 38 52 67 110 110 103 138 171
57 55 76 98 162 161 151 202 250
270 285 543 600 600 600 600 600 600
1200 1268 2415 2700 2700 2700 2700 2700 2700
2.5 mm Breakout Cables are also available.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
16 • Networking — Fiber
Breakout Cable Series
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.24
Industrial Armored Cable Tight Buffer — Riser & Plenum Rated
Applications
Ratings
■ Industrial environments
Riser UL Type cUL Type Flame Resistance Plenum UL Type cUL Type Flame Resistance
■ Rugged installations ■ Manufacturing plants ■ Mining operations ■ Telecommunications and data trunk ■ Inter- and intra-building installations
Heavy duty construction with interlocking aluminum armor (steel available on request) provides excellent mechanical protection from cutting or crushing and eliminates need for innerduct. Rodent resistant. Also available for outside plant. Loose tube design available on request. Jacket Material Riser & Plenum Buffer Tube Strength Member Central Strength Member Armor Color Code (Buffer)
PVC PVC Aramid Yarn E-Glass Aluminum Per EIA/TIA 598-A, see page 10.2
Jacket Color Single-mode 62.5/125 µm 50/125 µm / 1 Gbe 50/125 µm / 10 Gbe
Yellow Orange Orange Aqua
Temperature Range Storage Operating Crush Resistance (EIA-455-41) Impact Resistance (EIA-455-25) Min. Bend Radius Installation Long Term Optical Specifications
50 / 125µm Std. / 1 Gbe
Industrial Armored Series Riser (NEC/CEC OFCR/OFC FT4) 6 M9B230 M9A230 12 M9B231 M9A231 24 M9B232* M9A232* 24 M9B233 M9A233 36 M9B234 M9A234 48 M9B235 M9A235 72 M9B236 M9A236 96 M9B237 M9A237 144 M9B238 M9A238 Plenum (NEC/CEC OFCP/OFC FT6) 6 M9B240 M9A240 12 M9B241 M9A241 24 M9B242* M9A242* 24 M9B243 M9A243 36 M9B244 M9A244 48 M9B245 M9A245 72 M9B246 M9A246 96 M9B247 M9A247 144 M9B248 M9A248
50 / 125µm 10 Gbe – 300M
-40 to +70°C -20 to +70°C 2000 N/cm 2000 Impacts @ 3.0 N-m 20 x OD 15 x OD See page 10.2
Fiber Bundle Detail Aramid Strength Member
Outer Jacket
Aluminum Armor
Inner Jacket
Color Coded Jacket Specified Fiber (Color Coded)
Belden Part Number 62.5 / 125µm Std. / 1 Gbe
OFCP OFC FT6 NFPA 262
Specifications
Product Description
No. of Fibers
OFCR OFC FT4 UL 1666
Outside Diameter Single-mode Enhanced
Bundles of up to 12 Fibers Each
Central E-Glass Strength Member
Inch
mm
Weight Lbs./1000′′
kg/km
Max. Install Load Lbs.
N
M9C230 M9C231 M9C232* M9C233 M9C234 M9C235 M9C236 M9C237 M9C238
M9W230 M9W231 M9W232* M9W233 M9W234 M9W235 M9W236 M9W237 M9W238
0.570 0.620 0.670 0.845 0.970 0.970 1.095 1.245 1.320
14.50 15.70 17.00 21.46 24.64 24.64 27.82 31.62 33.55
126 149 179 263 368 368 481 625 675
188 222 266 391 548 548 716 930 1005
270 300 390 600 600 600 600 600 600
1201 1334 1735 2700 2700 2700 2700 2700 2700
M9C240 M9C241 M9C242* M9C243 M9C244 M9C245 M9C246 M9C247 M9C248
M9W240 M9W241 M9W242* M9W243 M9W244 M9W245 M9W246 M9W247 M9W248
0.471 0.506 0.631 0.781 0.881 0.906 1.056 1.256 1.331
12.00 12.90 16.00 19.84 22.38 23.01 26.82 31.90 33.81
87 103 151 289 309 320 451 608 687
129 153 225 430 460 476 671 905 1022
270 300 390 600 600 600 600 600 600
1201 1334 1735 2700 2700 2700 2700 2700 2700
*Single jacket design. All optical fiber products can be supplied in compliance with RoHS regulations.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.25
Tactical Cable Tight Buffer — Outdoor
Applications
Specifications
■ ENG vehicles
Temperature Range Storage Operating Crush Resistance (EIA-455-41) Impact Resistance (EIA-455-25) Cyclic Flexing (EIA-455-104) Min. Bend Radius Installation Long Term Optical Specifications
■ Outdoor news, sporting or other events ■ Digital camera transmission ■ Military communications ■ Re-deployable communications Product Description Small and lightweight with a rugged jacket, Tactical Cable provides a durable design for repeated deployment and retrieval cycles and a superior level of crush resistance. Designed to military standards. 50/125 micron fiber available on request. Jacket Material Buffer Strength Member Color Code (Jacket & Fibers)
UV-resistant PU Polyester Aramid Yarn Per EIA/TIA 598-A, see page 10.2
-70 to +85°C -55 to +85°C 440 N/cm 200 Impacts @ 2.2 N-m 2000 cycles, min. 15 x OD 8 x OD See page 10.2
Fiber Bundle Detail Outer Jacket
Tight Buffered Fiber
No. of Fibers
Belden Part Number
Outside Diameter
Weight
Max. Install Load
62.5 / 125µm Std. / 1 Gbe
Single-mode Enhanced
Inch
mm
Lbs./1000′′
kg/km
Lbs.
N
M96571 M96551 M96572 M96573 M96574 M96575
M96566 M96639 M96567 M96568 M96569 M96570
0.217 0.225 0.236 0.250 0.265 0.280
5.5 5.7 6.0 6.3 6.7 7.1
19 21 23 26 28 31
28 31 34 39 42 46
330 330 330 330 330 330
1468 1468 1468 1468 1468 1468
Tactical Series Outdoor 2 4 6 8 10 12
Please contact the Technical Support Group for proper connectivity integration and installation guidance.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
16 • Networking — Fiber
Aramid Strength Member
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.26
Ribbon Cable Riser and Plenum Rated
Applications
Specifications
■ Inter-equipment connections
Temperature Range Storage Operating Crush Resistance (EIA-455-41) Impact Resistance (EIA-455-25) Cyclic Flexing (EIA-455-104) Min. Bend Radius Installation Long Term Optical Specifications
■ NEBS applications Product Description Small size is ideal for connections in tight spaces. Color coded fibers. Suitable for use with standard ribbon connectors. Flexible, with half-inch minimum bend radius. Tight center-to-center tolerances. Optional identification printing available. Jacket Material Strength Member Color Code (Jacket & Fibers)
PVC Aramid Yarn Per EIA/TIA 598-A, see page 10.2
Jacket Color Single-mode 62.5/125µm 50/125 µm / 1 Gbe 50/125 µm / 10 Gbe
15 x OD 10 x OD See page 10.2
Fiber Bundle Detail Outer Jacket
Yellow Orange Orange Aqua Ribbon Fiber
Ratings Riser UL Type cUL Type Flame Resistance Plenum UL Type cUL Type Flame Resistance
No. of Fibers
-40 to +80°C -20 to +70°C 2000 N/cm 2000 Impacts @ 1.6 N-m 2000 cycles, min.
OFNR OFN FT4 UL 1666 OFNP OFN FT6 NFPA 262
Belden Part Number 62.5 / 125µm Std. / 1 Gbe
50 / 125µm Std. / 1 Gbe
Outside Diameter
Weight
Max. Install Load
50 / 125µm 10 Gbe – 300M
Single-mode Enhanced
Inch
mm
Lbs./1000′′
kg/km
M9C630 M9C631 M9C632 M9C633 M9C634
M9W630 M9W631 M9W632 M9W633 M9W634
0.114 0.78 x 0.115 0.78 x 0.137 0.78 x 0.158 0.78 x 0.180
2.9 2.0 x 2.9 2.0 x 3.5 2.0 x 4.0 2.0 x 4.6
5 4 6 6 7
7 6 9 9 10
100 100 100 100 100
444 444 444 444 444
M9C640 M9C641 M9C642 M9C643 M9C644
M9W640 M9W641 M9W642 M9W643 M9W644
0.114 0.78 x 0.115 0.78 x 0.137 0.78 x 0.158 0.78 x 0.180
2.9 2.0 x 2.9 2.0 x 3.5 2.0 x 4.0 2.0 x 4.6
5 4 6 6 7
7 6 9 9 10
100 100 100 100 100
444 444 444 444 444
Lbs.
N
Ribbon Series Riser (NEC/CEC OFNR/OFN FT4) 2 M9B630 M9A630 4 M9B631 M9A631 6 M9B632 M9A632 8 M9B633 M9A633 12 M9B634 M9A634 Plenum (NEC/CEC OFNP/OFN FT6) 2 M9B640 M9A640 4 M9B641 M9A641 6 M9B642 M9A642 8 M9B643 M9A643 12 M9B644 M9A644
Fiber Ribbon Cable is to be sold as bulk cable and has not been qualified for field connectorization.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.27
Single Jacket, All Dielectric Cable Loose Tube — Outdoor, and Indoor/Outdoor Riser Rated
Applications
Specifications
■ Medium to high fiber count requirements
Temperature Range (Outdoor Series) Storage Operating Temperature Range (Riser Series) Storage Operating Crush Resistance (EIA-455-41) Impact Resistance (EIA-455-25) Min. Bend Radius Installation Long Term Optical Specifications
■ Inter-building duct installations ■ Lashed aerial ■ Indoor/outdoor ■ Industrial outside plant Product Description Gel-filled buffer tube prevents water migration. All-dielectric strength member. Available as Riser rated cable, thereby eliminating the need for service entrance splicing to in-building cable. Full dielectric construction, no grounding required. Available with up to 216 fibers. Length markings in meters for easy determination of cable length.
-50 to +80°C -40 to +70°C -40 to +80°C -40 to +70°C 2000 N/cm 2000 Impacts @ 1.6 N-m 20 x OD 15 x OD See page 10.2
Fiber Bundle Detail Jacket Material Outdoor Riser Buffer Tube Strength Member Central Strength Member Color Code (Buffer)
PE PVC PBT Aramid Yarn E-Glass Per EIA/TIA 598-A, see page 10.2 Black
Jacket Color
Outer Jacket
Waterblocking Tape
Thermoplastic Tube Moisture Blocking Gel Multiple 250 micron Fibers
Fiber Bundles
Central E-Glass Strength Member
Ratings Riser UL Type cUL Type Flame Resistance
No. of Fibers
Fibers Per Tube
OFNR OFN FT4 UL 1666
Belden Part Number 62.5 / 125µm Std. / 1 Gbe
50 / 125µm Std. / 1 Gbe
50 / 125µm 10 Gbe – 300M
Outside Diameter Single-mode Enhanced
Inch
Weight
Max. Install Load
mm
Lbs./1000′′
kg/km
Lbs.
N
Loose Tube Series Outdoor 6 6 M9B510T M9A510T 12 6 M9B511T M9A511T 24 6 M9B500T M9A500T 36 6 M9B502T M9A502T 48 12 M9B505T M9A505T 72 12 M9B507T M9A507T 96 12 M9B513T M9A513T 144 12 M9B509T M9A509T 216 12 M9B520T M9A520T Riser (NEC/CEC OFNR/OFN FT4) 6 6 M9B810 M9A810 12 6 M9B811 M9A811 24 6 M9B812 M9A812 36 6 M9B813 M9A813 48 12 M9B814 M9A814 72 12 M9B815 M9A815 96 12 M9B816 M9A816 144 12 M9B817 M9A817
M9C510T M9C511T M9C500T M9C502T M9C505T M9C507T M9C513T M9C509T M9C520T
M9W510T M9W511T M9W500T M9W502T M9W505T M9W507T M9W513T M9W509T M9W520T
0.38 0.38 0.38 0.38 0.48 0.48 0.55 0.70 0.72
9.65 9.65 9.65 9.65 12.19 12.19 13.89 17.78 18.16
44 44 45 47 70 70 93 149 148
65 65 67 70 104 104 138 222 220
600 600 600 600 600 600 600 600 600
2700 2700 2700 2700 2700 2700 2700 2700 2700
M9C810 M9C811 M9C812 M9C813 M9C814 M9C815 M9C816 M9C817
M9W810 M9W811 M9W812 M9W813 M9W814 M9W815 M9W816 M9W817
0.38 0.38 0.38 0.38 0.48 0.48 0.55 0.70
9.65 9.65 9.65 9.65 12.19 12.19 13.89 17.78
63 62 61 60 89 87 114 187
94 92 91 89 132 129 170 278
600 600 600 600 600 600 600 600
2700 2700 2700 2700 2700 2700 2700 2700
Alternative fiber counts are available.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
16 • Networking — Fiber
Aramid Strength Members
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.28
Single Jacket, All Dielectric Cable Loose Tube — Indoor/Outdoor Plenum Rated
Applications
Ratings
■ Medium to high fiber count requirements
Plenum UL Type cUL Type Flame Resistance
■ Inter-building duct installations ■ Lashed aerial ■ Indoor/outdoor
OFNP OFN FT6 NFPA 262
Specifications
■ Campus backbones ■ Data Centers ■ High Density Cable Trays Product Description Dry waterblocking technology used within tubes and under jacket. Available as Plenum rated cable, thereby eliminating the need for service entrance splicing to in-building cable. Small diameter and bend radius facilitate installation in tight spaces. Full dielectric construction, no grounding required. Available with up to 144 fibers. Fibers grouped into sets of 12 for maximum density. Length markings in meters for easy determination of cable length. Jacket Material Non-unitized Unitized Buffer Tube Strength Member Central Strength Member Color Code (Buffer)
PVC PVDF PVC E-Glass and Aramid Yarn Upjacketed Per EIA/TIA 598-A, see page 10.2 Black
Jacket Color
Temperature Range Storage Operating Installation Crush Resistance (EIA-455-41) Impact Resistance (EIA-455-25) Cyclic Flexing (EIA-455-104) Min. Bend Radius Installation Long Term Optical Specifications
-40 to +80°C -40 to +70°C 0 to +60°C 2000 N/cm 2000 Impacts @ 1.6 N-m 2000 cycles, min. 20 x OD 15 x OD See page 10.2
Fiber Bundle Detail Outer Jacket
Color Coded Jacket
Specified Fiber (Color Coded)
Upjacketed Central Strength Member
2 – 12 FIBERS
No. of Fibers
Fibers Per Tube
62.5 / 125µm Std. / 1 Gbe
Belden Part Number 50 / 125µm 50 / 125µm Std. / 1 Gbe 10 Gbe – 300M
Overall Tape Barrier
Aramid Strength Member
>12 – 144 FIBERS
Outside Diameter Single-mode Enhanced
Inch
Bundles of up to 12 Fibers Each
Weight
Max. Install Load
mm
Lbs./1000′′
kg/km
Lbs.
N
6.70 6.70 9.12 9.12 9.12 10.90 12.73 16.89
33 33 47 47 48 71 105 189
49 49 70 70 71 106 156 281
320 320 405 405 405 585 903 1263
1423 1423 1801 1801 1801 2602 4017 5618
Loose Tube Series Plenum 6 12 24 36 48 72 96 144
(NEC/CEC OFNP/OFN FT6) 6 M9B202 M9A202 12 M9B204 M9A204 12 M9B205 M9A205 12 M9B206 M9A206 12 M9B207 M9A207 12 M9B209 M9A209 12 M9B211 M9A211 12 M9B215 M9A215
M9C202 M9C204 M9C205 M9C206 M9C207 M9C209 M9C211 M9C215
M9W202 M9W204 M9W205 M9W206 M9W207 M9W209 M9W211 M9W215
0.265 0.265 0.359 0.359 0.359 0.429 0.501 0.665
Alternative fiber counts and hybrid constructions are available.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.29
Double Jacket, Armored Cable Loose Tube – Outdoor, and Indoor/Outdoor Riser Rated
Applications
Ratings
■ Direct burial
Riser UL Type cUL Type Flame Resistance
■ Low to high fiber count requirements ■ Inter-building duct installations ■ Indoor/outdoor
Specifications
Product Description Gel-filled buffer tube prevents water migration. Available as Riser rated cable, thereby eliminating the need for service entrance splicing to in-building cable. Rodent resistant. Available in sizes up to 216 fibers. Length markings in meters for easy determination of cable length. Jacket Material Outdoor Riser Buffer Tube Outdoor Riser Strength Member Central Strength Member Armor Color Code (Buffer) Jacket Color
PE PVC PBT PVC Aramid Yarn E-Glass Corrugated Steel Tape Per EIA/TIA 598-A, see page 10.2 Black
Temperature Range (Outdoor) Storage Operating Temperature Range (Riser) Storage Operating Crush Resistance (EIA-455-41) Impact Resistance (EIA-455-25) Min. Bend Radius Installation Long Term Optical Specifications
50 / 125µm Std. / 1 Gbe
50 / 125µm 10 Gbe – 300M
20 x OD 15 x OD See page 10.2
Outer Jacket
Fiber Bundles
Thermoplastic Tube
Corrugated Steel Armor Inner Jacket
Multiple 250µ Fibers
Belden Part Number 62.5 / 125µm Std. / 1 Gbe
-40 to +80°C -40 to +70°C 2000 N/cm 2000 Impacts @ 1.6 N-m
Fiber Bundle Detail
Moisture Blocking Gel
Fibers Per Tube
-50 to +80°C -40 to +70°C
Aramid Strength Members Waterblocking Tape
E-Glass Central Strength Member
Outside Diameter Single-mode Enhanced
Inch
Weight
Max. Install Load
mm
Lbs./1000′′
kg/km
Lbs.
N
Loose Tube Series — Armored Outdoor 6 6 M9B381T M9A381T 12 6 M9B382T M9A382T 24 6 M9B384T M9A384T 36 6 M9B386T M9A386T 48 12 M9B389T M9A389T 72 12 M9B391T M9A391T 96 12 M9B398T M9A398T 144 12 M9B393T M9A393T 216 12 M9B400T M9A400T Riser (NEC/CEC OFCR/OFC FT4) 6 6 M9B890 M9A890 12 6 M9B891 M9A891 24 6 M9B892 M9A892 36 6 M9B893 M9A893 48 12 M9B894 M9A894 72 12 M9B895 M9A895 96 12 M9B896 M9A896 144 12 M9B897 M9A897
M9C381T M9C382T M9C384T M9C386T M9C389T M9C391T M9C398T M9C393T M9C400T
M9W381T M9W382T M9W384T M9W386T M9W389T M9W391T M9W398T M9W393T M9W400T
0.53 0.53 0.53 0.53 0.65 0.65 0.69 0.87 0.87
13.46 13.46 13.46 13.46 16.51 16.51 17.53 22.10 22.10
101 102 103 103 144 142 168 241 241
150 152 153 153 214 211 250 359 359
600 600 600 600 600 600 600 600 600
2700 2700 2700 2700 2700 2700 2700 2700 2700
M9C890 M9C891 M9C892 M9C893 M9C894 M9C895 M9C896 M9C897
M9W890 M9W891 M9W892 M9W893 M9W894 M9W895 M9W896 M9W897
0.54 0.54 0.54 0.54 0.66 0.66 0.70 0.88
13.72 13.72 13.72 13.72 16.76 16.76 17.78 22.35
138 137 136 135 176 172 206 302
205 204 202 201 262 256 307 449
600 600 600 600 600 600 600 600
2700 2700 2700 2700 2700 2700 2700 2700
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
16 • Networking — Fiber
■ Industrial outside plant
No. of Fibers
OFCR OFC FT4 UL 1666
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.30
Double Jacket, Heavy-Duty Cable Loose Tube — Outdoor
Applications
Specifications
■ Direct burial
Temperature Range Storage Operating Crush Resistance (EIA-455-41) Impact Resistance (EIA-455-25) Min. Bend Radius Installation Long Term Optical Specifications
■ Harsh environments ■ Applications requiring good ozone-, moisture- and weather-resistance Product Description Gel-filled buffer tube prevents water migration. Available with up to 216 fibers.
-50 to +80°C -40 to +70°C 2000 N/cm 2000 Impacts @ 1.6 N-m 20 x OD 15 x OD See page 10.2
Fiber Bundle Detail
Jacket Material Outer Jacket: Inner Jacket: Buffer Tube Strength Member Central Strength Member Core Wrap Color Code (Buffer)
PE PE PBT Aramid Yarn E-Glass Water Swellable Tape Per EIA/TIA 598-A, see page 10.2 Black
Jacket Color
Dry Water-Blocking System
Polyethylene Outer Jacket Aramid Strength Member
Optical Fibers
Polyethylene Inner Jacket Gel-filled Buffer Tube
Fiber Bundles
Dielectric Central Strength Member
Binder Rip Cords
No. of Fibers
Fibers Per Tube
Belden Part Number 62.5 / 125µm Std. / 1 Gbe
50 / 125µm Std. / 1 Gbe
Outside Diameter
50 / 125µm 10 Gbe – 300M
Single-mode Enhanced
M9C840 M9C841 M9C842 M9C843 M9C844 M9C845 M9C846 M9C847 M9C848 M9C849 M9C820 M9C821 M9C822
M9W840 M9W841 M9W842 M9W843 M9W844 M9W845 M9W846 M9W847 M9W848 M9W849 M9W820 M9W821 M9W822
Inch
Weight
Max. Install Load
mm
Lbs./1000′′
kg/km
Lbs.
N
11.18 11.18 11.18 11.18 11.18 11.18 11.18 11.18 13.72 13.72 15.37 19.30 19.30
60 60 60 60 60 60 60 60 136 136 152 255 255
89 89 89 89 89 89 89 89 202 202 226 379 379
600 600 600 600 600 600 600 600 600 600 600 600 600
2700 2700 2700 2700 2700 2700 2700 2700 2700 2700 2700 2700 2700
Loose Tube Series — Heavy Duty Outdoor 2 4 6 8 12 18 24 36 48 72 96 144 216
2 4 6 4 6 6 6 6 12 12 12 12 12
M9B840 M9B841 M9B842 M9B843 M9B844 M9B845 M9B846 M9B847 M9B848 M9B849 M9B820 M9B821 M9B822
M9A840 M9A841 M9A842 M9A843 M9A844 M9A845 M9A846 M9A847 M9A848 M9A849 M9A820 M9A821 M9A822
0.44 0.44 0.44 0.44 0.44 0.44 0.44 0.44 0.54 0.54 0.61 0.76 0.76
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.31
Central Tube Cable Loose Tube—Outdoor, and Outdoor Armored
Applications
Specifications
■ Campus OSP backbones
Temperature Range Storage Operating Crush Resistance (EIA-455-41) Impact Resistance (EIA-455-25) Min. Bend Radius Installation Long Term Optical Specifications
■ Drop cable ■ Telecommunications and data trunk ■ Direct burial (armored only) ■ Lashed aerial Product Description Economical option for low fiber counts. Quick and easy end preparation. Fully waterblocked with gel-filled buffer tube. No rods – easy handling. Crush, impact and abrasion resistant. Jacket Material Buffer Tube Core Wrap Strength Member Armor Color Codes (Jacket & Fibers)
20 x OD 15 x OD See page 10.2
Fiber Bundle Detail MDPE Outer Jacket
PE PBT Water Swellable Tape Fiberglass Corrugated Steel Per EIA/TIA 598-A, see page 10.2 Black
Jacket Color
-40 to +70°C -40 to +70°C 2000 N/cm 2000 Impacts @ 1.6 N-m
Steel Armor Fiberglass Strength Member Gel-filled Buffer Tube Optical Fibers Rip Cord
SINGLE ARMOR
Belden Part Number 62.5 / 125µm Std. / 1 Gbe
50 / 125µm Std. / 1 Gbe
50 / 125µm 10 Gbe – 300M
M9A150 M9A151 M9A152 M9A153 M9A154 M9A155
M9C150 M9C151 M9C152 M9C153 M9C154 M9C155
M9A170 M9A171 M9A172 M9A173 M9A174 M9A175
M9C170 M9C171 M9C172 M9C173 M9C174 M9C175
Outside Diameter Single-mode Enhanced
Weight
Max. Install Load
Inch
mm
Lbs./1000′′
kg/km
Lbs.
N
M9W150 M9W151 M9W152 M9W153 M9W154 M9W155
0.325 0.325 0.325 0.325 0.325 0.325
8.26 8.26 8.26 8.26 8.26 8.26
36 36 36 36 36 36
54 54 54 54 54 54
600 600 600 600 600 600
2700 2700 2700 2700 2700 2700
M9W170 M9W171 M9W172 M9W173 M9W174 M9W175
0.410 0.410 0.410 0.410 0.410 0.410
10.41 10.41 10.41 10.41 10.41 10.41
72 72 72 72 72 72
108 108 108 108 108 108
600 600 600 600 600 600
2700 2700 2700 2700 2700 2700
Central Tube Series Outdoor 2 M9B150 4 M9B151 6 M9B152 8 M9B153 10 M9B154 12 M9B155 Outdoor Armored 2 M9B170 4 M9B171 6 M9B172 8 M9B173 10 M9B174 12 M9B175
All optical fiber products can be supplied in compliance with RoHS regulations. Please contact Customer Service for more details.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
16 • Networking — Fiber
No. of Fibers
ALL DIELECTRIC
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.32
Micro Loose Tube Breakout Style Cable Loose Tube – Outdoor, Indoor/Outdoor OFN & Indoor/Outdoor Riser Rated
Applications
Specifications
■ Ducts between buildings (above or below frost lines)
Temperature Range Storage Operating Crush Resistance (EIA-455-41) Impact Resistance (EIA-455-25) Min. Bend Radius Installation Long Term Optical Specifications
■ Lashed aerial ■ Telecommunications and data trunk Product Description Easy handling and termination of a breakout style cable. Loose buffer dimensions compatible with standard connectors (900 µm). Waterblocking gel for moisture protection. Breakout kits not required for connectorization. Jacket Material Outdoor Riser General Purpose Buffer tube Outdoor + Riser Strength Elements Strength Member(s) Color Codes (Jacket & Fibers) Jacket Color
PE PVC TPE PBT Aramid Yarn Upjacketed Aramid Per EIA/TIA 598-A, see page 10.2 Black
-40 to +70°C -20 to +70°C 600 N/cm 20 Impacts @ 1.0 N-m 20 x OD 15 x OD See page 10.2
Fiber Bundle Detail Polyethylene Outer Jacket
900 micron Mini Tube
Gel-filled Buffer
Sub-unit Jacket .098 inch (2.5mm)
Upjacketed Aramid Strength Members
Aramid Strength Members
Ratings Riser UL Type cUL Type Flame Resistance General Purpose UL/cUL Type Flame Resistance
OFNR OFN FT4 UL 1666 OFN UL 1581
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.33
Micro Loose Tube Breakout Style Cable Loose Tube – Outdoor, Indoor/Outdoor OFN & Indoor/Outdoor Riser Rated (continued)
No. of Fibers
Belden Part Number 62.5 / 125µm Std. / 1 Gbe
50 / 125µm Std. / 1 Gbe
50 / 125µm 10 Gbe – 300M
M9A700 M9A701 M9A702 M9A703 M9A704 M9A705
M9C700 M9C701 M9C702 M9C703 M9C704 M9C705
M9A720 M9A721 M9A722 M9A723 M9A724 M9A725 M9A740 M9A741 M9A742 M9A743 M9A744 M9A745
Outside Diameter Single-mode Enhanced
Weight
Max. Install Load
Inch
mm
Lbs./1000′′
kg/km
M9W700 M9W701 M9W702 M9W703 M9W704 M9W705
0.340 0.360 0.360 0.418 0.478 0.614
8.64 9.14 9.14 10.62 12.14 15.60
41 41 39 54 76 129
61 61 58 80 113 192
330 345 285 405 600 600
1468 1535 1267 1801 2700 2700
M9C720 M9C721 M9C722 M9C723 M9C724 M9C725
M9W720 M9W721 M9W722 M9W723 M9W724 M9W725
0.344 0.364 0.364 0.424 0.482 0.618
8.74 9.25 9.25 10.72 12.24 15.70
50 51 49 68 77 130
74 76 73 101 115 193
330 345 285 405 600 600
1468 1535 1267 1801 2700 2700
M9C740 M9C741 M9C742 M9C743 M9C744 M9C745
M9W740 M9W741 M9W742 M9W743 M9W744 M9W745
0.352 0.372 0.372 0.432 0.490 0.626
8.94 9.45 9.45 10.97 12.45 15.90
54 55 51 74 94 151
80 82 76 110 140 229
330 345 285 405 600 600
1468 1535 1267 1801 2700 2700
Lbs.
N
Micro Loose Tube Series Outdoor 1 M9B700 2 M9B701 4 M9B702 6 M9B703 8 M9B704 12 M9B705 Indoor/Outdoor OFN 1 M9B720 2 M9B721 4 M9B722 6 M9B723 8 M9B724 12 M9B725 Indoor/Outdoor Riser 1 M9B740 2 M9B741 4 M9B742 6 M9B743 8 M9B744 12 M9B745
16 • Networking — Fiber
Please contact the Technical Support Group for proper connectivity integration and installation guidance.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
O P T I C A L
F I B E R
16.34
TrayOptic Heavy-Duty, All Dielectric Cable ®
Loose Tube — Indoor/Outdoor Riser Rated
Applications
Specifications
■ Industrial and other harsh environment applications
Temperature Range Storage Operating Crush Resistance (EIA-455-41) Impact Resistance (EIA-455-25)
■ Factory automation ■ Direct burial Product Description
-40 to +70°C -40 to +70°C 2000 N/cm 2000 impacts @ 1.6N-m 25 cycles, 12 lbs., 20 x OD radius min.
Cyclic Flexing (EIA-455-104)
Laser Optimized Fiber to handle Gigabit Ethernet light sources and expanded bandwidth requirements. Passes IEEE 383-2003 flame test. Waterblocking agent for moisture protection. CPE outer jacket option provides extra chemical or abrasion resistance. Fiber Type Jacket Material Strength Member Jacket Color
62.5/125µ PVC or CPE Aramid Yarn Orange
Min. Bend Radius Installation Long Term Maximum Installation Load Optical Specifications
20 x OD 15 x OD 600 lbs. (2700 N) See page 10.2
Fiber Bundle Detail Outer Jacket
Aramid Strength Member
Inner Jacket
Ratings Riser UL Type cUL Type Flame Resistance
Waterblocking Agent
OFNR OFN FT4 IEEE 383-2003
Optical Fibers
Binder
Gel-filled Buffer Tube
Dielectric Central Strength Member
No. of Fibers
Fibers Per Tube
Outside Diameter Inches
PVC Jacket
mm
Belden Part No.
Weight Lbs./1000′′
FT4) 11.18 11.18 11.18 11.18 11.18 11.18 11.18 11.18 13.72 13.72 13.72
I100255 I100455 I100655 I400855 I601255 I601855 I602455 I603655 I604855 I606055 I607255
88 88 88 88 88 88 88 88 136 136 136
CPE Jacket Weight kg/km
Belden Part No.
Weight Lbs./1000′′
Weight kg/km
131 131 131 131 131 131 131 131 202 202 202
I100266 I100466 I100666 I400866 I601266 I601866 I602466 I603666 I604866 I606066 I607266
83 83 83 83 83 83 83 83 129 129 129
124 124 124 124 124 124 124 124 192 192 192
TrayOptic Series Riser (NEC/CEC OFNR/OFN 2 2 0.440 4 4 0.440 6 6 0.440 8 4 0.440 12 6 0.440 18 6 0.440 24 6 0.440 36 6 0.440 48 12 0.540 60 12 0.540 72 12 0.540
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
Mouser Electronics Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Belden Wire & Cable: AX102242 AX102738 AX101169 AX350600 AX102737 AX102907 AX101829 AX102008 AX102244 AX102243