Preview only show first 10 pages with watermark. For full document please download

Optosonic 3 Radio Net - Ista International Gmbh

   EMBED


Share

Transcript

Device Manual Chapter 4.1-W optosonic 3 radio net L.83.0050 - Release 8.0.0 CH 2014 ista International GmbH - Grugaplatz 2 - 45131 Essen http//www.ista.com Nur für den internen Gebrauch—For internal use only—Uniquement pour utilisation interne Table of contents 2/12 1 Device data 3 1.1 General information 3 1.2 Device display 3 1.3 Technical data 4 1.4 Main and connection dimensions 5 2 Item numbers 6 3 Installation 7 3.1 Screwed installation 7 3.2 Installation with cable ties 7 3.2.1 With mounting plate 7 3.2.2 Without mounting plate 7 3.3 Final steps 8 4 Commissioning 9 5 Exchange 10 5.1 Preparatory steps 10 5.2 For installation on mounting plate 10 5.3 If installing without mounting plate 10 6 Reading 11 6.1 Radio reading AMM 11 6.2 Radio reading Walk by 11 7 Disposal 12 Device Manual 4.1-W optosonic 3 radio net Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne L.83.0050 - Release 8.0.0 CH 2014 ista International GmbH - Grugaplatz 2 - 45131 Essen http://www.ista.com Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne L.83.0050 - Release 8.0.0 CH 2014 ista International GmbH - Grugaplatz 2 - 45131 Essen http//www.ista.com 1 Device data 1.1 General information Device group Systems Product name optosonic 3 radio net Pictogram Design/type Radio module for sensonic® II Functional description The optosonic 3 radio net radio module is used to integrate the sensonic® II heat meter into the ista symphonic sensor net radio system. To this end, the opto head of the optosonic 3 radio net is connected to the optical interface of the sensonic® II. The optosonic 3 radio net uses this interface to read out the measured values of the sensonic® II. The data is saved in the module. The optosonic 3 radio net is programmed via radio. If connected terminals have to be reprogrammed, the necessary data is transmitted to the module by radio. This then carries out the actual programming of the terminal. Packaging Single package (1 pc. per carton) Delivery scope ▪ optosonic 3 radio net ▪ 2 screws 1.2 Device display Type plate optosonic® 3 radio net S/N: XXX XXX XXX Art. N° 19450 Display Device Manual 4.1-W optosonic 3 radio net No display 3/12 L.83.0050 - Release 8.0.0 CH 2014 ista International GmbH - Grugaplatz 2 - 45131 Essen http://www.ista.com Technical data Functional principle Interfaces Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne 1.3 Optical read-out of connected counters ▪ Output: Radio interface for the ista radio system symphonic sensor net. ▪ Input: Opto head (protected against reversed polarity), cable length 0.5 m. Radio interface ▪ Compatible with symphonic sensor net ▪ Transmission power: < 10 mW ▪ Radio frequency: 868 MHz ▪ Duration of transmission telegram: < 10 msec/transmission ▪ Transmission rate: ~ 90 kbaud (bit/sec) ▪ Transmission method: bidirectional ▪ Data integrity: encrypted transfer Weight 0.110 kg Material ABS Casing colour RAL 9002 CE label 1999/5/EC Storage Temperature: ▪ 1st year: -25 °C to +70 °C ▪ then 0 °C to +70 °C To be stored in a dry place Ambient temperature 0 °C - 70 °C Relative humidity 5 % - 95 % Protection class IP54 acc. to EN 60529 i.e.: ▪ Protection against foreign objects: Protects against damaging amount of dust. ▪ Protects against contact: complete protection against contact. ▪ Protection against water: Protection against splash water on all sides. Power supply 3 V lithium battery Life cycle 10 years + 1 year reserve + 1 year storage Technology Integrated circuit (standard) Parameterisation data ▪ Radio network number ▪ Reference date 4/12 Device Manual 4.1-W optosonic 3 radio net Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne L.83.0050 - Release 8.0.0 CH 2014 ista International GmbH - Grugaplatz 2 - 45131 Essen http//www.ista.com Recorded data ▪ Serial number, device ID ▪ Current date and time ▪ Next due date ▪ Commissioning date ▪ Error status Saved consumption values Energy quantity (total volume) for ▪ 14 month-end values with date ▪ 2 reference date values with date Reading frequency 1.4 Generally 12 - 52 times per year Main and connection dimensions Main dimensions H = 28 mm W = 57 mm L = 100 mm Opto head dimensions H = 15 mm W = 64 mm L = 19 mm Cable length Device Manual 4.1-W optosonic 3 radio net 0.5 m 5/12 2 Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne L.83.0050 - Release 8.0.0 CH 2014 ista International GmbH - Grugaplatz 2 - 45131 Essen http://www.ista.com Item numbers Devices 19450 optosonic 3 radio net 19452 optosonic/pulsonic 3 radio mounting plate 81621 Adhesive seal sensonic, grey 81627 ista meter tamper proofing, grey 10 x 40 Accessories 6/12 Device Manual 4.1-W optosonic 3 radio net Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne L.83.0050 - Release 8.0.0 CH 2014 ista International GmbH - Grugaplatz 2 - 45131 Essen http//www.ista.com 3 Installation 3.1 Screwed installation 1 2 3 1. Prior to drilling, check that there are no electricity cables, gas or water pipes below the surface at the installation site. 2. Drill holes (6 mm) 5 6 4. Attach the mounting plate to the wall. 5. Align the mounting plate vertically using spirit level. with mounting plate to determine the hole spacing. 3. Insert dowels. 3.2 4 6. Tighten screws firmly. Continue with final steps. Installation with cable ties 3.2.1 With mounting plate 1 2 1. Connect cable ties to the mounting plate. Continue with final steps. 2. Fasten the mounting plate with cable ties (e.g. on a pipe). 3.2.2 Without mounting plate 1 2 1. Connect cable ties to optosonic 3 radio net . Continue with item 8. 2. Fasten the optosonic 3 radio net with cable ties (e.g. to a pipe). Device Manual 4.1-W optosonic 3 radio net 7/12 3.3 1 Final steps 2 3 4 5 6 1. Position module on mounting plate (if installing with mounting plate). 4. Glue the opto head onto the sensonic II. 2. Clean the contact surface on the sensonic II. 6. Use adhesive seals to seal the opto head above the screws. 5. Screw together the opto head and sensonic II. 3. Pull off the protective foil from the rear of the opto head. 8/12 Device Manual 4.1-W optosonic 3 radio net Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne L.83.0050 - Release 8.0.0 CH 2014 ista International GmbH - Grugaplatz 2 - 45131 Essen http://www.ista.com Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne L.83.0050 - Release 8.0.0 CH 2014 ista International GmbH - Grugaplatz 2 - 45131 Essen http//www.ista.com 4 Commissioning 1 2 3 4 5 7 8 9 10 11 1. Open clamping cover. 2. Jumper in as delivered condition. 3. Remove jumper. The optosonic attempts to set up communication with the heat meter via the optical interface. If this attempt is successful, the optosonic switches to installation mode for 4 minutes. 4. Parameterizing with PDA and MGW 5. Following parameterisation or 4 minutes the device switches to measuring mode. 6. Position jumper on the right-hand pins and pull off again after approx. 5 seconds. The device sends installation beacons for 4 minutes. 7. Parameterizing with PDA and MGW 8. Following parameterisation or 4 minutes the device switches to measuring mode. ▪ Following parameterisation, continue with step 9. ▪ After 4 minutes without parameterisation, continue with step 6 (10 attempts in total). 9. Close clamping cover ▪ Following parameterisation, continue with step 9. 10. Seal screw. ▪ After 4 minutes without parameterisation continue with 11. Clean the device. step 6. Device Manual 4.1-W optosonic 3 radio net 6 9/12 5 Exchange 5.1 Preparatory steps 1 2 1. Undo the screws in the opto head. 5.2 1 For installation on mounting plate 2 1. Remove old optosonic 3 radio net from the mounting plate. 5.3 1 2. Continue with installation from point 7. If installing without mounting plate 2 1. Cut cable ties (for installation without mounting plate). 10/12 2. Disconnect the opto head from the sensonic II. 2. Continue with installation from point 1b. Device Manual 4.1-W optosonic 3 radio net Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne L.83.0050 - Release 8.0.0 CH 2014 ista International GmbH - Grugaplatz 2 - 45131 Essen http://www.ista.com Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne L.83.0050 - Release 8.0.0 CH 2014 ista International GmbH - Grugaplatz 2 - 45131 Essen http//www.ista.com 6 Reading 6.1 Radio reading AMM 1 1. Readout via symphonic sensor net. 6.2 1 Radio reading Walk by 2 1. Read off appliances with PDA/MGW by Walk by Device Manual 4.1-W optosonic 3 radio net 2. Check data in the PDA Are all devices recorded? 11/12 7 1 Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne L.83.0050 - Release 8.0.0 CH 2014 ista International GmbH - Grugaplatz 2 - 45131 Essen http://www.ista.com Disposal 2 1. Do not dispose of the old device in the household waste. They will ensure proper disposal. 2. Send obsolete devices to the main warehouse via outlet. 12/12 Device Manual 4.1-W optosonic 3 radio net