Transcript
OPzS 2-350
2V350Ah
OPzS Series Battery Range Summary The OPzS battery is a traditional tubular plate flooded battery which offers 20 years design life according to IEC60896-11.This range battery is most suited for use in all standby power applications that demand the highest levels of reliability and security.
Application Control Equipment Medical Equipment Railroad Utility Photovoltaic System Alternative Energy System
Telecommunications Cable Television Electric Utility Security System UPS
General Features Maintenance convenient. DIN40736-1 complaint. Transparent containers, convenient to observe. Special filter installation for acid fog proof. High quality and high reliability. Super long service life. Special pole sealed technology.
7mm (0.28inch)
20mm (0.79inch)
M8mm (0.31inch)
Construction Terminal ...... Copper Separator ...... Rubber Electrolyte ...... Sulfuric acid
Lead dioxide Lead SAN ABS
Battery Model
OPzS2-350
Designed Floating Life Capacity(20oC)
Dimensions
206mm(8.11inch)
20 Years 24HR(16.8A,1.80V)
10HR(35A,1.80V)
408Ah
350Ah
5HR(60A,1.80V)
1HR(185A,1.80V) 185Ah
300Ah
Length
Width
Height
Total Height
124mm(4.88inch)
206mm(8.11inch)
470mm(18.5inch)
525mm(20.7inch)
Approx. Weight
without electrolyte:20.5Kg (45.2 lbs)
with electrolyte:27Kg(59.5 lbs) o
Internal Resistance
Full charged at 20 C: 0.00075 Ohm
Self Discharge
3% of capacity declined per month at (20oC)
Capacity Affected by Temp.(10HR) Charge Voltage(20oC)
124mm(4.88 inch)
Terminal Dimensions
409mm(16.1inch)
...... ...... ...... ......
354mm(13.9inch)
Positive Negative Container Cover
40oC 109%
20oC
0oC
100%
85%
-15oC 65%
Cycle use
Float use
2.35V-2.40V(-5mV/ oC), max. Current: 70A
2.21V-2.25V(-3mV/ oC)
Page 1 of 2
OPzS 2-350
2V350Ah
Charge Voltage
(CA) (V/Cell)
(%) 120
2.35 100 80
0.20
Discharge Characteristic (20oC)
Charge Characteristic o
Constant Charge at 0.2CA-2.35V (20 C) Charge Capacity
Charge Voltage
2.17 100%Discharge
60
0.15
40
0.10
20
0.05
2.00
50%Discharge
1.83 Charge Current
0
0
0
2
4
6
8
10
Discharge Voltage (V/Cell)
Current
Charge
Charge Capacity
OPzS Series Battery
2.17 2.00 1.83 0.05CA 0.25CA 0.1CA
1.67 1.60
1CA
0.6CA
30
60
1.33 0
12
2
6
12
3
10 Hour
5000
6000
Min
Time(hour)
20
100 90
2.10
80 70
2.05
DOD(%)
Battery Voltage (V/Cell)
Relationship of OCV and state of charge 2.15
2.00
60 50 40 30 20
1.95
10 1.90
0 0
10
20
30
40
50
60
70
80
90
100
0
1000
Remained Capacity(%)
2000
3000
4000
7000
cycle life (cycles)
Constant current discharge ratings-amperes at 20oC TIME
1h
3h
5h
10h
24h
48h
72h
100h
120h
240h
CUT-OFF VOLTAGE
1.80
1.80
1.80
1.80
1.80
1.80
1.80
1.80
1.80
1.80
CAPACITY(Ah)
185
263
300
350
403
438
466
490
497
504
Constant power discharge ratings-watts at 20oC TIME
1h
3h
5h
10h
24h
48h
72h
100h
120h
240h
CUT-OFF VOLTAGE
1.80
1.80
1.80
1.80
1.80
1.80
1.80
1.80
1.80
1.80
CAPACITY(Wh)
337
486
557
648
745
809
860
907
919
932
ISO9001
COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2