Preview only show first 10 pages with watermark. For full document please download

Opzs2 350

   EMBED


Share

Transcript

OPzS 2-350 2V350Ah OPzS Series Battery Range Summary The OPzS battery is a traditional tubular plate flooded battery which offers 20 years design life according to IEC60896-11.This range battery is most suited for use in all standby power applications that demand the highest levels of reliability and security. Application Control Equipment Medical Equipment Railroad Utility Photovoltaic System Alternative Energy System Telecommunications Cable Television Electric Utility Security System UPS General Features Maintenance convenient. DIN40736-1 complaint. Transparent containers, convenient to observe. Special filter installation for acid fog proof. High quality and high reliability. Super long service life. Special pole sealed technology. 7mm (0.28inch) 20mm (0.79inch) M8mm (0.31inch) Construction Terminal ...... Copper Separator ...... Rubber Electrolyte ...... Sulfuric acid Lead dioxide Lead SAN ABS Battery Model OPzS2-350 Designed Floating Life Capacity(20oC) Dimensions 206mm(8.11inch) 20 Years 24HR(16.8A,1.80V) 10HR(35A,1.80V) 408Ah 350Ah 5HR(60A,1.80V) 1HR(185A,1.80V) 185Ah 300Ah Length Width Height Total Height 124mm(4.88inch) 206mm(8.11inch) 470mm(18.5inch) 525mm(20.7inch) Approx. Weight without electrolyte:20.5Kg (45.2 lbs) with electrolyte:27Kg(59.5 lbs) o Internal Resistance Full charged at 20 C: 0.00075 Ohm Self Discharge 3% of capacity declined per month at (20oC) Capacity Affected by Temp.(10HR) Charge Voltage(20oC) 124mm(4.88 inch) Terminal Dimensions 409mm(16.1inch) ...... ...... ...... ...... 354mm(13.9inch) Positive Negative Container Cover 40oC 109% 20oC 0oC 100% 85% -15oC 65% Cycle use Float use 2.35V-2.40V(-5mV/ oC), max. Current: 70A 2.21V-2.25V(-3mV/ oC) Page 1 of 2 OPzS 2-350 2V350Ah Charge Voltage (CA) (V/Cell) (%) 120 2.35 100 80 0.20 Discharge Characteristic (20oC) Charge Characteristic o Constant Charge at 0.2CA-2.35V (20 C) Charge Capacity Charge Voltage 2.17 100%Discharge 60 0.15 40 0.10 20 0.05 2.00 50%Discharge 1.83 Charge Current 0 0 0 2 4 6 8 10 Discharge Voltage (V/Cell) Current Charge Charge Capacity OPzS Series Battery 2.17 2.00 1.83 0.05CA 0.25CA 0.1CA 1.67 1.60 1CA 0.6CA 30 60 1.33 0 12 2 6 12 3 10 Hour 5000 6000 Min Time(hour) 20 100 90 2.10 80 70 2.05 DOD(%) Battery Voltage (V/Cell) Relationship of OCV and state of charge 2.15 2.00 60 50 40 30 20 1.95 10 1.90 0 0 10 20 30 40 50 60 70 80 90 100 0 1000 Remained Capacity(%) 2000 3000 4000 7000 cycle life (cycles) Constant current discharge ratings-amperes at 20oC TIME 1h 3h 5h 10h 24h 48h 72h 100h 120h 240h CUT-OFF VOLTAGE 1.80 1.80 1.80 1.80 1.80 1.80 1.80 1.80 1.80 1.80 CAPACITY(Ah) 185 263 300 350 403 438 466 490 497 504 Constant power discharge ratings-watts at 20oC TIME 1h 3h 5h 10h 24h 48h 72h 100h 120h 240h CUT-OFF VOLTAGE 1.80 1.80 1.80 1.80 1.80 1.80 1.80 1.80 1.80 1.80 CAPACITY(Wh) 337 486 557 648 745 809 860 907 919 932 ISO9001 COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2 (Updated: 1-Nov-2010)