Preview only show first 10 pages with watermark. For full document please download

Opzv 2-2000 2v2000ah

   EMBED


Share

Transcript

OPzV 2-2000 2V2000AH OPzV Series SLA Battery Opzv Series BSB Opzv Series Valve Regulated Lead Acid batteries are designed with a proven combination of GEL and Tubular technologies to offer a very high lever of reliability. Opzv batteries benefit from an optimized plate design which gives capacities in excess of the DIN standard values. In addition, this series offers both a longest float life and a high cycle life in widely industrial field. Application · Telecommunications · Cable Television · Electric Utility · Control Equipment · Security System · Medical Equipment · UPS · Railroad Utility · Photovoltaic System · Alternative Energy System General Features 3mm [0.12inch] · Sealed and maintenance free operation. · Non-Spillable construction design. · ABS containers and covers(UL94HB, UL94V-0) optional. · Safety valve installation for explosion proof. · High quality and high reliability. · Super long service life. · Lowest self discharge characteristic. · Super reliability. 14mm [0.55inch] 8mm [0.31inch] Construction · Sealant ........Epoxy Resin · Safety valve .....EPDR ! Terminal ........ Copper ! Separator ...... PVC-SiO2 ! Electrolyte .....Sulfuric acid Thixotropic Gel Terminal Dimensions 399mm [15,71inch] 797mm [31,38inch] 772mm [30,39inch] · Component ......Raw material · Positive ........Lead dioxide · Negative ........Lead · Container ........ABS · Cover ........ABS 212mm[8,35inch] Battery Model OPzV 2-2000 Designed Floating Life Capacity(25oC) Dimensions 15 Years 20HR(102A,1.75V) 10HR(200A,1.75V) 5HR(347A,1.75V) 2040AH 2000AH 1735AH 1295AH Length Width Height Total Height 399mm(15.71inch) 212mm(8.35inch) 772mm(30.39inch) 797mm(31.38inch) 160Kg (352.80 lbs) Approx. Weight Full charged at 25oC: 0.0005 Ohm Internal Resistance 3% of capacity declined per month at (25oC) Self Discharge Capacity Affected by Temp.(20HR) Charge Voltage(25oC) 1HR(1295A,1.75V) o 40 C 25oC 0oC -15oC 102% 100% 85% 65% Cycle use Float use 2.3V-2.35V(-5mV/ oC), max. Current: 400A 2.25-2.27V(-3.3mV/ oC) Page 1 of 2 OPzV 2-2000 2V2000AH Charge Voltage Constant Charge At 0.25CA-2.30V (25 C) (CA) (V/Cell) 100 80 0.25 Charge Capacity Charge Voltage 2.17 100%Discharge 0.20 60 2.00 50%Discharge 0.15 40 0.10 20 1.83 0.05 0 0 Charge Current 0 2 4 6 8 10 2.17 2.00 1.83 0.25CA 0.1CA 1.67 1.60 1CA 0.6CA 30 60 0.05CA 1.33 0 12 2 6 12 3 Min Time(hour) 10 Hour 20 Self Discharge Characteristics Relationship of OCV and state of charge 110 105 2.25 2.17 Capacity (%) Battery Voltage (V/Cell) 25 C o 120 2.33 o Discharge Characteristic Charge Characteristic Discharge Voltage (V/Cell) Charge (%) Current Charge Capacity OPzV Series SLA Battery 2.08 2.00 100 95 90 85 80 75 70 65 60 55 50 1.92 o 1.83 0 10 20 30 40 50 60 70 80 90 100 40 0 1 2 20oC o 40 C 45 30 C 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Storage time:months Remained Capacity(%) Constant current discharge ratings-amperes at 25oC F.V/Time 1.70V 1.75V 1.80V 1.83V 1.87V 1.90V 15MIN 1824 1600 1344 1216 960 800 30MIN 1552 1408 1232 1120 960 800 1HR 1168 1100 984 904 792 696 2HR 756 720 676 640 576 520 3HR 560 544 520 496 453 410 5HR 372 363 351 338 311 282 8HR 248 246 239 229 218 205 10HR 205 204 200 192 181 170 20HR 125 124 120 116 105 99.9 3HR 1050 1044 1003 964 872 788 5HR 752 732 707 666 600 518 8HR 510 495 460 439 408 383 10HR 398 392 362 362 335 322 20HR 243 238 216 205 195 189 Constant power discharge ratings-watts at 25oC F.V/Time 1.70V 1.75V 1.80V 1.83V 1.87V 1.90V 15MIN 3057 2708 2201 2090 1669 1608 30MIN 2525 2212 2109 1801 1641 1610 1HR 1887 1815 1636 1603 1566 1378 2HR 1354 1396 1314 1248 1105 1005 ISO9001 Address:Meilong Road,LongHua Town,BaoAn District,Shenzhen,China. TEL.86-755-28094189 Fax:86-755-8372 2565 Email:[email protected] Page 2 of 2 Http:// www.wbrbattery.com