Preview only show first 10 pages with watermark. For full document please download

Opzv2 1200

   EMBED


Share

Transcript

OPzV 2-1200 2V1200Ah OPzV Series SLA Battery Range Summary By combining the newly developed tubular positive plates with fumed gelled electrolyte, BSB created the innovative OPzV range of batteries. The range offers 20 years design life and very high deep cycling capabilities. This range is recommended for telecom outdoor applications, renewable energy systems and other harsh environment applications. Application · Medical Equipment · UPS · Railroad Utility · Photovoltaic System · Alternative Energy System · Telecommunications · Cable Television · Electric Utility · Control Equipment · Security System General Features · Sealed and maintenance free operation. · Non-Spillable construction design. · ABS containers and covers(UL94 V0, optional). · Safety valve installation for explosion proof. · High quality and high reliability. · Super long service life. · Lowest self discharge characteristic. · Super reliability. 7mm (0.28inch) 20mm (0.79inch) M8mm (0.31inch) Construction Safety valve Terminal Separator Electrolyte ...... ...... ...... ...... EPDR Copper Polymer Thixotropic Gel 275mm(10.83inch) Terminal Dimensions 681mm(26.8inch) Lead dioxide Lead ABS ABS Epoxy Resin 646mm(25.4inch) Positive ...... Negative ...... Container ...... ...... Cover Sealant ...... 210mm(8.27inch) Battery Model OPzV 2-1200 Designed Floating Life Capacity(20oC) 20 Years 20HR(64.0A,1.80V) 10HR(120A,1.80V) 5HR(211A,1.75V) 1HR(706A,1.75V) 1200Ah 1055Ah 706Ah 1280Ah Dimensions Length Width Height Total Height 275mm(10.83inch) 210mm(8.27inch) 646mm(25.4inch) 681mm(26.8inch) Approx. Weight 84Kg (185 lbs) Internal Resistance Full charged at 20oC: 0.00027 Ohm Self Discharge 2% of capacity declined per month at (20oC) Capacity Affected by Temp.(10HR) Charge Voltage(20oC) 40oC 109% 20oC 0oC 100% 85% Cycle use 2.35V-2.40V(-5mV/ oC), max. Current: 240A Page 1 of 2 -15oC 65% Float use 2.25-2.29V(-3mV/ oC) OPzV 2-1200 2V1200Ah Charge Voltage (CA) (V/Cell) (%) 120 2.35 100 80 0.20 Discharge Characteristic (20oC) Charge Characteristic o Constant Charge at 0.2CA-2.35V (20 C) Charge Capacity Charge Voltage 2.17 100%Discharge 60 0.15 40 0.10 20 0.05 2.00 50%Discharge 1.83 Charge Current 0 0 0 2 4 6 8 10 Discharge Voltage (V/Cell) Current Charge Charge Capacity OPzV Series SLA Battery 2.17 2.00 1.83 0.05CA 0.25CA 0.1CA 1.67 1.60 0 12 2 6 30 60 3 10 Hour 20 Self Discharge Characteristics 2.25 110 105 2.17 100 95 90 Capacity (%) Battery Voltage (V/Cell) 12 Min Relationship of OCV and state of charge 2.00 0.6CA 1.33 Time(hour) 2.08 1CA 85 80 75 70 65 60 55 50 1.92 45 1.83 0 10 20 30 40 50 60 70 80 90 100 40 0 o 3 20oC 30oC 40 C 6 9 12 15 18 21 24 27 30 Storage time:months Remained Capacity(%) Constant current discharge ratings-amperes at 20oC F.V/Time 1.70V 1.75V 1.80V 1.83V 1.87V 1.90V 15min 1272 1128 984 888 720 624 30min 1032 936 840 756 660 588 1h 738 706 655 605 542 491 2h 429 417 399 384 354 330 3h 318 312 300 292 274 258 5h 213 211 208 203 195 185 8h 147 146 144 141 134 129 10h 122 121 120 117 112 107 20h 65.3 64.7 64.0 62.3 59.9 57.2 3h 640 623 603 596 583 540 5h 438 433 424 405 399 386 8h 290 284 280 268 262 251 10h 235 234 233 225 220 210 20h 125 124 122 120 118 115 Constant power discharge ratings-watts at 20oC F.V/Time 1.70V 1.75V 1.80V 1.83V 1.87V 1.90V 15min 2193 2018 1788 1645 1555 1294 30min 1787 1712 1607 1378 1304 1199 1h 1339 1300 1227 1130 1098 1000 2h 814 793 770 735 730 705 ISO9001 COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2 (Updated: 1-Nov-2010)