Preview only show first 10 pages with watermark. For full document please download

Opzv2 500

   EMBED


Share

Transcript

OPzV 2-500 2V500Ah OPzV Series SLA Battery Range Summary By combining the newly developed tubular positive plates with fumed gelled electrolyte, BSB created the innovative OPzV range of batteries. The range offers 20 years design life and very high deep cycling capabilities. This range is recommended for telecom outdoor applications, renewable energy systems and other harsh environment applications. Application · Telecommunications · Cable Television · Electric Utility · Control Equipment · Security System · Medical Equipment · UPS · Railroad Utility · Photovoltaic System · Alternative Energy System General Features · Sealed and maintenance free operation. · Non-Spillable construction design. · ABS containers and covers(UL94 V0, optional). · Safety valve installation for explosion proof. · High quality and high reliability. · Super long service life. · Lowest self discharge characteristic. · Super reliability. 7mm (0.28inch) 20mm (0.79inch) M8mm (0.31inch) Construction Safety valve Terminal Separator Electrolyte Lead dioxide Lead ABS ABS Epoxy Resin ...... ...... ...... ...... EPDR Copper Polymer Thixotropic Gel 506mm(19.9inch) 166mm(6.54inch) Terminal Dimensions 471mm(18.5inch) Positive ...... Negative ...... Container ...... ...... Cover Sealant ...... 206mm(8.11inch) Battery Model OPzV 2-500 Designed Floating Life Capacity(20oC) 20 Years 20HR(27.0A,1.80V) 10HR(50.0A,1.80V) 500Ah 540Ah Dimensions 5HR(88.2A,1.75V) 441Ah 274Ah Length Width Height Total Height 166mm(6.54inch) 206mm(8.11inch) 471mm(18.5inch) 506mm(19.9inch) Approx. Weight 35.5Kg (78.3 lbs) Internal Resistance Full charged at 20oC: 0.00065 Ohm Self Discharge 2% of capacity declined per month at (20oC) Capacity Affected by Temp.(10HR) Charge Voltage(20oC) 1HR(274A,1.75V) 40oC 109% 20oC 0oC 100% 85% Cycle use 2.35V-2.40V(-5mV/ oC), max. Current: 100A Page 1 of 2 -15oC 65% Float use 2.25-2.29V(-3mV/ oC) Opzv 2-500 2V500Ah Charge Voltage (CA) (V/Cell) (%) 120 2.35 100 80 0.20 Discharge Characteristic (20oC) Charge Characteristic o Constant Charge At 0.2CA-2.35V (20 C) Charge Capacity Charge Voltage 2.17 100%Discharge 60 0.15 40 0.10 20 0.05 2.00 50%Discharge 1.83 Charge Current 0 0 0 2 4 6 8 10 Discharge Voltage (V/Cell) Current Charge Charge Capacity Opzv Series SLA Battery 2.17 2.00 1.83 0.05CA 0.25CA 0.1CA 1.67 1.60 0 2 6 Relationship of OCV and state of charge 30 60 3 10 Hour 20 Self Discharge Characteristics 2.25 110 105 2.17 100 95 90 Capacity (%) Battery Voltage (V/Cell) 12 Min Time(hour) 2.00 0.6CA 1.33 12 2.08 1CA 85 80 75 70 65 60 55 50 1.92 45 1.83 0 10 20 30 40 50 60 70 80 90 100 40 0 o 3 20oC 30oC 40 C 9 6 12 15 18 21 24 27 30 Storage time:months Remained Capacity(%) Constant current discharge ratings-amperes at 20oC F.V/Time 1.70V 1.75V 1.80V 1.83V 1.87V 1.90V 15min 572 515 448 406 350 292 30min 437 406 371 342 303 273 1h 283 274 259 245 237 203 2h 175 171 164 159 149 137 3h 129 127 123 119 114 106 5h 90.0 88.2 86.5 85.0 84.0 74.5 8h 62.0 61.6 60.0 59.5 58.0 55.0 10h 52.0 51.0 50.0 49.7 48.0 46.0 20h 28.0 27.5 27.0 26.8 25.9 24.8 3h 235 230 225 221 210 180 5h 158 156 153 149 145 127 8h 114 112 109 105 100 95.0 10h 95.3 95.0 94.0 93.5 88.8 85.8 20h 57.0 56.0 55.0 54.0 52.0 51.0 Constant power discharge ratings-watts at 20oC F.V/Time 1.70V 1.75V 1.80V 1.83V 1.87V 1.90V 15min 936 825 685 600 538 520 30min 762 711 634 555 468 500 1h 511 477 467 442 429 388 2h 343 333 301 290 275 247 ISO9001 COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2 (Updated: 1-Nov-2010)