OPzV 2-800 2V800Ah OPzV Series SLA Battery Range Summary By combining the newly developed tubular positive plates with fumed gelled electrolyte, BSB created the innovative OPzV range of batteries. The range offers 20 years design life and very high deep cycling capabilities. This range is recommended for telecom outdoor applications, renewable energy systems and other harsh environment applications. Application · Medical Equipment · UPS · Railroad Utility · Photovoltaic System · Alternative Energy System · Telecommunications · Cable Television · Electric Utility · Control Equipment · Security System General Features · Sealed and maintenance free operation. · Non-Spillable construction design. · ABS containers and covers(UL94 V0, optional). · Safety valve installation for explosion proof. · High quality and high reliability. · Super long service life. · Lowest self discharge characteristic. · Super reliability. 7mm (0.28inch) 20mm (0.79inch) M8mm (0.31inch) Construction Safety valve Terminal Separator Electrolyte ...... ...... ...... ...... EPDR Copper Polymer Thixotropic Gel 191mm(7.52inch) Terminal Dimensions 681mm(26.8inch) Lead dioxide Lead ABS ABS Epoxy Resin 646mm(25.4inch) Positive ...... Negative ...... Container ...... ...... Cover Sealant ...... 210mm(8.27inch) Battery Model OPzV 2-800 Designed Floating Life Capacity(20oC) 20 Years 20HR(43.0A,1.80V) 10HR(80.0A,1.75V) 1HR(448A,1.75V) 705Ah 448Ah 800Ah 860Ah Dimensions 5HR(141A,1.75V) Length Width Height Total Height 191mm(7.52inch) 210mm(8.27inch) 646mm(25.4inch) 681mm(26.8inch) Approx. Weight 58.5Kg (129 lbs) Internal Resistance Full charged at 20oC: 0.0004 Ohm Self Discharge 2% of capacity declined per month at (20oC) Capacity Affected by Temp.(10HR) Charge Voltage(20oC) 40oC 109% 20oC 0oC 100% 85% Cycle use 2.35V-2.40V(-5mV/ oC), max. Current: 160A Page 1 of 2 -15oC 65% Float use 2.25-2.29V(-3mV/ oC) OPzV 2-800 2V800Ah Charge Voltage (CA) (V/Cell) (%) 120 2.35 100 80 0.20 Discharge Characteristic (20oC) Charge Characteristic o Constant Charge At 0.2CA-2.35V (20 C) Charge Capacity Charge Voltage 2.17 100%Discharge 60 0.15 40 0.10 20 0.05 2.00 50%Discharge 1.83 Charge Current 0 0 0 2 4 6 8 10 Discharge Voltage (V/Cell) Current Charge Charge Capacity OPzV Series SLA Battery 2.17 2.00 1.83 0.05CA 0.25CA 0.1CA 1.67 1.60 0 12 2 6 30 60 3 10 Hour 20 Self Discharge Characteristics 2.25 110 105 2.17 100 95 90 Capacity (%) Battery Voltage (V/Cell) 12 Min Relationship of OCV and state of charge 2.00 0.6CA 1.33 Time(hour) 2.08 1CA 85 80 75 70 65 60 55 50 1.92 45 1.83 0 10 20 30 40 50 60 70 80 90 100 40 0 o 3 20oC 30oC 40 C 6 9 12 15 18 21 24 27 30 Storage time:months Remained Capacity(%) Constant current discharge ratings-amperes at 20oC F.V/Time 1.70V 1.75V 1.80V 1.83V 1.87V 1.90V 15min 848 752 656 592 480 416 30min 688 624 560 504 440 392 1h 468 448 416 384 344 312 2h 286 278 266 256 236 220 3h 212 208 200 195 183 172 5h 142 141 139 136 130 124 8h 98.0 97.6 96.0 94.0 89.6 86.0 10h 82.0 81.0 80.0 78.0 74.5 71.5 20h 44.3 43.7 43.0 42.1 40.2 38.6 3h 427 417 402 396 389 353 5h 293 289 284 269 260 256 8h 195 191 189 179 174 167 10h 158 156 154 151 146 138 20h 86.5 86.0 85.0 84.0 81.0 78.5 Constant power discharge ratings-watts at 20oC F.V/Time 1.70V 1.75V 1.80V 1.83V 1.87V 1.90V 15min 1462 1346 1192 1096 1038 890 30min 1190 1142 1074 919 870 799 1h 849 810 779 718 699 635 2h 542 528 514 490 480 472 ISO9001 COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2 (Updated: 1-Nov-2010)