OR4160 -FA Application 4 Optical to electrical conversion of four return path signals in hybrid fiber coax (HFC) networks
Features 4 Four independent optical receivers 4 Bandwidth 5…160 MHz 4 Each of the 4 receivers can be switched to the -20dB test port on front 4 Pilot tone and optical input power controlled AGC to keep the RF level independent from the optical input power 4 Wide optical input power range 4 Each receiver section can be disabled separately 4 Optical power detection on all inputs 4 Sleep mode for the unused receiver 4 RS485 remote supervision and control interface 4 SC/APC or E2000 connector as standard 4 Requires 1 slot in 2G6 rack
2 G 6 – Series OR4160 FA
Block Diagram
BKtel communications GmbH ⋅ www.bktel.com ⋅ e-Mail:
[email protected]
1
2G6
Technical Data Electrical/Optical Characteristics Parameter
Symbol
Input Wavelength Range
Min
Typ
Max
Unit
1270
1610
dBm
+2
dBm
Optical Input Power
PIN
-16
Optical Return Loss
ORL
45
dB
η
0.8
A/W
Power Supply Voltage
Vcc
22.8
Power Consumption
P
Detector Responsitivity (1310nm)
Optical Connector
24
25.2
V
10
W
SC/APC
RF-Connectors
F
EMC
EN 50083-2
RF Characteristics Parameter
Min
Typ
Max
Unit
RF bandwidth
5
-
200
MHz
2.5
4
pA/√Hz
75
-
Ω
RF Impedance
-
RF Return Loss
16@ 47 MHz
Isolation between RF-Ports (OUT #1 / OUT #2 / OUT #3 / OUT #4) Flatness 5 … 160 MHz 5 … 200 MHz
50
Nominal RF output level (@ OMI=5%)
+0.75 +1.0 75*
(@ OMI=10%) IM2, IM3 (2 carriers, OMI=20% each, 0dBm, 85dBµV)
50
Frequency of ALC pilot tone
590
dB 640 5
36
Testpoint attenuation
20 dB ± 1.5
RF Output Level for AGC Control (OMI= 5%)
BKtel communications GmbH ⋅ www.bktel.com ⋅ e-Mail:
[email protected]
kHz % dB
*) higher RF output level are adjustable if opt. input power is higher -16dBm (RF +10dB for opt. min P=-11dBm)
2
dB dB dBµV
81*
OMI of pilot tone
2 G 6 – Series OR4160 FA
dB
-0.75 -1.0
ALC range
dB
dB
Specifications subject to change without notice - DBe_OR4160_130717.doc
Receiver noise current @ -16 dBm