Preview only show first 10 pages with watermark. For full document please download

Os-5040c - Metravi

   EMBED


Share

Transcript

METRAVI 25MHZ/40MHZ FOUR TRACE OSCILLOSCOPE OS-5025C/ OS-5040C WITH COMPONENT TEST FACILITY GENERAL SPECIFICATIONS This compact, light weight model 25MHz/40MHz oscilloscope with component test facility has a frequency range of DC-25MHz, DC-40MHz separately and offers the following features: l Wide frequency range: DC-25MHz(25MHz) DC-40MHz(40MHz) . l High sensitivity: 1mV/div . l Large size CRT: Waveforms are easy to read, on the large 6-inch CRT with an internal graticule scale. l Scale: Waveforms are parallax-free with the CRT's internal graticule scale. l Alt Mag: The normal (×1) and the×5 magnified waveforms can be displayed simultaneously. l Alt Trig: Stabilized triggering is accomplished even with two unrelated signals. l TV synchronization: Stable TV signals are displayed using new circuitry. l Auto focus: Focus deviation is automatically corrected. l Trigger Lock: The trigger circuit is in automatically synchronic state. l Component test: Component tester is the special circuit with which a single component or components in or out of actual circuit board can be easily tested requiring no power to drive the circuit. l Digital code switch: the scale is more accuracy with good handle and high reliable.(only for 25MHz) The display shows FAULTS of components, size of a component value, and characteristics of components, and half-dead components under a dynamic test. ELECTRICAL SPECIFICATIONS Vertical Axis Item CH1 and CH2 sensitivity Accuracy Variable vertical sensitivity Frequencybandwidth×5MAG Rise time Input impedance Max input voltage Input coupling system Operating systems Invert Overshoot Specification 25MHz 5mV/div to 10V/div 1-2-5 step, 11 calibrated steps (1mV/div to 1V/div at×5 MAG) ×1:±3%, ×5 : ±5% 0ºC~40ºC (Vertical knob is set to CAL position) To less than 1/2.5 times indicated sensitivity value DC: DC to 25MHz AC:10Hz to 25MHz DC:DC to 7MHz AC:10Hz to 7MHz Approximately 14ns 1MW±2%, 25 pF±3pF 300V (DC+AC peak) AC-GND-DC CH1:Only Channel 1 operates CH2:Only Channel 2 operates ADD: Algebraic sum of 2 signals (CH1+CH2) Dual: Channels 1 and 2 simultaneously displayed Only CH2 signal is inverted Maximum 5% 40MHz DC: DC to 40MHz AC:10Hz to 40MHz Approximately 8.8ns CH1 Output Amplifier(only for 25MHz) Output voltage Output impedance Band width Minimum 20mV/div Approximately 50W 50Hz to 5MHz (-3dB) Time axis Sweep mode Sweep time Sweep expansion Alt. MAG TRACE Trace Sep. Var ×1, ×5 ; ×1, ×5ALT 0.1µs to 0.2s/div±5%, in 20calibrated steps(1-2-5 seq) 20ns/div to 40ms/div Maximum 4 traces Minimum1.5 div *Technical Specifications & Appearance are subject to change without prior notice THE QUALITY LEADER www.metravi.com METRAVI 25MHZ/40MHZ FOUR TRACE OSCILLOSCOPE WITH COMPONENT TEST FACILITY OS-5025C/ OS-5040C ELECTRICAL SPECIFICATIONS Triggering Trigger mode Trigger signal source Polarity Coupling system 25MHz AUTO, NORM, TV-V,TV-H INT, CH2, LINE, EXT +, AC coupling Frequency INT Sensit-ivity NORM 10Hz-25MHz 2div AUTO 20Hz-25MHz 2div LOCK 50Hz-15MHz 2div TVSync. INT Minimum 1 div EXT Minimum 1 Vp-p 25MHz has ALT triggering, Amplitude=3div, trigger frequency:50Hz-25MHz. 40MHz 25MHz EXT 300mV 300mV 300mV XY operation Operating mode Sensitivity Input impedance X-axis band width Phase difference CH1, X-axis and CH2, Y-axis; When in X-Y operation mode As vertical axis 1MW±2% , 25pF±3 pF DC-500kHz £ 3º (DC-50kHz) Z axis Input impedance Maximum input voltage Band width Input signal 33kW 30V (DC+AC peak), MAX AC 1KHz DC to 2MHz ±5V (NEGATIVE INCREASES INTENSITY) CAL Frequency Output level Duty 1kHz±2% 0.5V (±2%) =48: 52 Power supply Voltage Frequency Power consumption AC 200V~240V 50Hz/60Hz 35W CRT Type Acceleration voltage Effective screen 6inch square internal scale -1.9kV 8div (vertical direction)×10div (horizontal direction) Mechanical specifications Physical dimensions Weight Height Width 140 (H) 335 (W) Approximately 7.2kg Environmental conditions Operating temperature Operating humidity Guaranteed operating temperature Guaranteed operating humidity Guaranteed maintained temperature Guaranteed maintained humidity 0ºC to 40º0C 35% to 90% 10ºC to 35ºC 45% to 85% -20ºC to 70ºC 35% to 85% (Less than 70% at temperatures exceeding 500C) Frequency 10Hz-40MHz 20Hz-40MHz 50Hz-20MHz 40MHz INT 2div 2div 2div EXT 800mV 800mV 800mV 12kV Length 375 (D) *Technical Specifications & Appearance are subject to change without prior notice THE QUALITY LEADER www.metravi.com